This document gives a brief overview of each of the dynamic techniques which are described in detail in the subsequent parts of ISO 6145. This document provides basic information to support an informed choice for one or another method for the preparation of calibration gas mixtures. It also describes how these methods can be linked to national measurement standards to establish metrological traceability for the composition of the prepared gas mixtures. Since all techniques are dynamic and rely on flow rates, this document describes the calibration process by measurement of each individual flow rate generated by the device. Methods are also provided for assessing the composition of the generated gas mixtures by comparison with an already validated calibration gas mixture. This document provides general requirements for the use and operation of dynamic methods for gas mixture preparation. It also includes the necessary expressions for calculating the calibration gas composition and its associated uncertainty. Gas mixtures obtained by these dynamic methods can be used to calibrate or control gas analysers. The storage of dynamically prepared gas mixtures into bags or cylinders is beyond the scope of this document.

  • Standard
    23 pages
    English language
    sale 15% off
  • Standard
    24 pages
    French language
    sale 15% off

ISO 6145 is a series of documents dealing with various dynamic methods used for the preparation of calibration gas mixtures. This document specifies a method for continuous preparation of calibration gas mixtures, from nominally pure gases or gas mixtures by use of thermal mass-flow controllers. The method is applicable to preparation of mixtures of non-reacting species, i.e. those which do not react with any material of construction of the flow path in the thermal mass-flow controller or the ancillary equipment. If this method is employed for preparation of calibration gas mixtures the optimum performance is as follows: the relative expanded measurement uncertainty U, obtained by multiplying the standard uncertainty by a coverage factor k = 2, is not greater than 2 %. If pre-mixed gases are used instead of pure gases, mole fractions below 10−6 can be obtained. The measurement of mass flow is not absolute and the flow controller requires independent calibration. The merits of the method are that a large quantity of the calibration gas mixture can be prepared on a continuous basis and that multi-component mixtures can be prepared as readily as binary mixtures if the appropriate number of thermal mass-flow controllers is utilized. NOTE Gas blending systems, based upon thermal mass-flow controllers, and some including the facility of computerization and automatic control, are commercially available.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

ISO 6145-6:2017 specifies a method for the dynamic preparation of calibration gas mixtures containing at least two gases (usually one of them is a complementary gas) from pure gases or gas pre-mixtures using critical flow orifices systems. The method applies principally to the preparation of mixtures of non-reactive gases that do not react with any of the materials forming the gas circuit inside the critical flow orifices system or auxiliary equipment. It has the merit of allowing multi-component mixtures to be prepared as readily as binary mixtures if an appropriate number of critical flow orifices are used. By selecting appropriate combinations of critical flow orifices, a dilution ratio of 1 × 104 is achievable. Although it is more particularly applicable to the preparation of gas mixtures at atmospheric pressure, the method also offers the possibility of preparing calibration gas mixtures at pressures greater than atmospheric. The upstream pressure will need to be at least two times higher than downstream pressure. The range of flow rates covered by this document extends from 1 ml/min to 10 l/min.

  • Standard
    27 pages
    English language
    sale 15% off
  • Standard
    27 pages
    French language
    sale 15% off

ISO 6145 comprises a series of International Standards dealing with various dynamic methods used for the preparation of calibration gas mixtures. ISO 6145-2:2014 describes a method and preparation system using piston pumps. The mixture composition and its associated uncertainty are based on calibration of the piston pumps by dimensional measurements. The calibration gas mixtures prepared using this method consist of two or more components, prepared from pure gases or other gas mixtures using gas-mixing pumps. Such gas-mixing pumps contain at least two piston pumps, each driven with a defined ratio of strokes, and appropriate accessories for gas feeding and mixture homogenization. ISO 6145-2:2014 is applicable only to mixtures of gaseous or totally vaporized components including corrosive gases, as long as these components neither react with each other nor with the wetted surfaces of the mixing pump. The use of gas mixtures as parent gases is covered as well. Multi-component gas mixtures and multi-step dilution procedures are included in this International Standard as they are considered to be special cases of the preparation of two-component mixtures. ISO 6145-2:2014 describes a method of preparing calibration gas mixtures whose composition is expressed in volume fractions. The necessary equations and associated uncertainty evaluation to express the gas composition in amount?of?substance fractions are given in Annex A. With this method, provided that sufficient quality assurance and control measures are taken, calibration gas mixtures can be prepared with a relative expanded uncertainty of 0,5 % (coverage factor k = 2) in the volume fraction. Numerical examples showing that under specified conditions smaller uncertainties are attainable are given in Annexes B through D. Using this method, dilution ratios of 1:10 000 can be achieved in discrete increments. Lower fractions (down to 1 × 10−8) can be achieved by multi-stage dilution or by the use of gas mixtures as input gases. Final mixture flow rates of 5 l/h to 500 l/h can be realized depending on the equipment used.

  • Standard
    30 pages
    English language
    sale 15% off

ISO 6145-5:2009 is one of a series of International Standards dealing with the various dynamic volumetric techniques used for the preparation of calibration gas mixtures. This part specifies a method for the continuous production of calibration gas mixtures from pure gases or gas mixtures using capillary calibration devices in single or multiple combinations (gas dividers). Single capillary systems can be used to provide gas mixtures where the minor component is in the range of volume fractions from 10-8 to 0,5. The relative expanded uncertainty of this technique is less than ±2 % (k = 2) relative. This application is used in industrial gas mixing panels for the production of specific gas atmospheres. Gas dividers can be used to divide gas mixtures prepared from gases or gas mixtures into controlled proportions by volume. These devices are capable of dilutions in the range of volume fractions from 0,000 5 to 0,9 of the primary gas concentration with a relative repeatability of better than 0,5 %. Traceability of the gas mixtures produced by a gas divider is achieved by comparison of a mixture with gas mixtures related to national or international gas standards. An example is given in Annex A.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 6145-9:2009 is one of a series of International Standards dealing with various dynamic volumetric methods used for the preparation of calibration gas mixtures. This part specifies a method for continuous production of calibration gas mixtures containing one or more readily condensable components. A relative expanded uncertainty of measurement, U, obtained by multiplying the relative combined standard uncertainty by a coverage factor k = 2, of not greater than ±1 %, can be obtained using this method. Unlike the methods presented in the other parts of ISO 6145, the method described in this part does not require accurate measurement of flow rates since flow rates do not appear in the equations for calculation of the volume fraction. Readily condensable gases and vapours commonly become adsorbed on surfaces, and it is therefore difficult to prepare stable calibration gas mixtures of accurately known composition, containing such components, by means of static methods. In addition, these calibration gas mixtures cannot be maintained under a pressure near the saturation limit without the occurrence of condensation. The saturation method can be employed to prepare mixtures of this type.

  • Standard
    14 pages
    English language
    sale 15% off
  • Standard
    14 pages
    French language
    sale 15% off

ISO 6145-8:2005 specifies a dynamic method using diffusion for the preparation of calibration gas mixtures containing component mole fractions ranging from 10-9 to 10-3. A relative expanded uncertainty of measurement, U, obtained by multiplying the relative combined standard uncertainty by a coverage factor k = 2, of not greater than ± 2 % can be achieved by using this method. By keeping the path between the diffusion source and place of use as short as possible, the method can be applied for the generation of low-concentration calibration gases of organic components that are liquid at room temperature, with boiling points ranging from about 40 °C to 160 °C. ISO 6145-8:2005 is applicable not only for the generation of calibration gas mixtures of a wide range of hydrocarbons at ambient and indoor air concentration levels, but also for the generation of low-concentration gas mixtures of water.

  • Standard
    19 pages
    English language
    sale 15% off
  • Standard
    20 pages
    French language
    sale 15% off

ISO 6144:2003 specifies a method for the preparation of calibration gas mixtures by a static volumetric method and provides a procedure for calculating the volumetric composition of the mixture. It can be used either with binary gas mixtures (containing one calibration component in a complementary gas, which is usually nitrogen or air) or with mixtures containing more than one component in the complementary gas. This International Standard also specifies how the expanded uncertainty in the volume fraction of each calibration component in the mixture is determined by a rigorous evaluation of all the measurement uncertainties involved, including those associated with the apparatus used for the preparation of the gas mixture and those associated with the experimental procedure itself.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    29 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 6145 specifies a dynamic method using permeation membranes for the preparation of calibration gas mixtures containing component mole fractions ranging from 10−9 and 10−6. A relative expanded uncertainty of 2,5 % of the component mole fraction can be achieved using this method. In the mole fraction range considered, it is difficult to maintain some gas mixtures, for example in cylinders, in a stable state. It is therefore desirable to prepare the calibration gas immediately before use, and to transfer it by the shortest possible path to the place where it is to be used. This technique has been successfully applied in generating low content calibration gas mixtures of, for example, sulfur dioxide (SO2), nitrogen dioxide (NO2) and benzene (C6H6) in air. If the carrier gas flow is measured as a gas mass-flow, the preparation of calibration gas mixtures using permeation tubes is a dynamic-gravimetric method which gives contents in mole fractions.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off

ISO 6145-7:2009 specifies a method for continuous production of calibration gas mixtures, containing two or more components, from pure gases or other gas mixtures by use of commercially available thermal mass-flow controllers. If this method is employed for the preparation of calibration gas mixtures, the optimum performance is as follows: the relative expanded uncertainty of measurement, U, obtained by multiplying the combined standard uncertainty by a coverage factor k = 2, is not greater than 2 %. If pre-mixed gases are used instead of pure gases, mole fractions below 10-6 can be obtained. The measurement of mass flow is not absolute and the flow controller requires independent calibration. The merits of the method are that a large quantity of the gas mixture can be prepared on a continuous basis and that multicomponent mixtures can be prepared as readily as binary mixtures if the appropriate number of thermal mass-flow controllers is utilized.

  • Standard
    15 pages
    English language
    sale 15% off
  • Standard
    15 pages
    French language
    sale 15% off

ISO 6145-1:2003 specifies the calibration methods involved in the preparation of gas mixtures by dynamic volumetric techniques. It also gives a brief presentation of a non-exhaustive list of examples of dynamic volumetric techniques which are described in more detail in other parts of ISO 6145.

  • Standard
    32 pages
    English language
    sale 15% off
  • Standard
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    32 pages
    French language
    sale 15% off
  • Standard
    13 pages
    English language
    sale 15% off
  • Standard
    13 pages
    French language
    sale 15% off
  • Standard
    12 pages
    English language
    sale 15% off
  • Standard
    12 pages
    French language
    sale 15% off
  • Standard
    10 pages
    English language
    sale 15% off
  • Standard
    10 pages
    French language
    sale 15% off