Single-capped fluorescent lamps - Performance specifications (IEC 60901:1996/A6:2014)

CMs required - WI=58957
Work started in CLC/SR 34A then transferred in the newly created CLC/TC 34A (D145/097)

Einseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise (IEC 60901:1996/A6:2014)

Lampes à fluorescence à culot unique - Prescriptions de performances (IEC 60901:1996/A6:2014)

Fluorescenčne sijalke z enim vznožkom - Specifikacije lastnosti - Dopolnilo A6 (IEC 60901:1996/A6:2014)

General Information

Status
Published
Publication Date
01-Jul-2019
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
17-Jun-2019
Due Date
22-Aug-2019
Completion Date
02-Jul-2019

Relations

Buy Standard

Amendment
EN 60901:2001/A6:2019
English language
107 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 60901:2001/A6:2019
01-september-2019
Fluorescenčne sijalke z enim vznožkom - Specifikacije lastnosti - Dopolnilo A6
(IEC 60901:1996/A6:2014)
Single-capped fluorescent lamps - Performance specifications (IEC
60901:1996/A6:2014)
Einseitig gesockelte Leuchtstofflampen - Anforderungen an die Arbeitsweise (IEC
60901:1996/A6:2014)
Lampes à fluorescence à culot unique - Prescriptions de performances (IEC
60901:1996/A6:2014)
Ta slovenski standard je istoveten z: EN 60901:1996/A6:2017
ICS:
29.140.30 Fluorescenčne sijalke. Sijalke Fluorescent lamps.
Discharge lamps
SIST EN 60901:2001/A6:2019 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 60901:2001/A6:2019

---------------------- Page: 2 ----------------------

SIST EN 60901:2001/A6:2019

EUROPEAN STANDARD EN 60901:1996/A6

NORME EUROPÉENNE

EUROPÄISCHE NORM
September 2017
ICS 29.140.30
English Version
Single-capped fluorescent lamps - Performance specifications
(IEC 60901:1996/A6:2014 , modified)
Lampes à fluorescence à culot unique - Prescriptions de Einseitig gesockelte Leuchtstofflampen - Anforderungen an
performances die Arbeitsweise
(IEC 60901:1996/A6:2014 , modifiée) (IEC 60901:1996/A6:2014 , modifiziert)
This amendment A6 modifies the European Standard EN 60901:1996; it was approved by CENELEC on 2017-08-16. CENELEC members
are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this amendment the status of a
national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language made by translation under the
responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as
the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2017 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
 Ref. No. EN 60901:1996/A6:2017 E

---------------------- Page: 3 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017 (E)

European foreword
The text of document 34A/1801/FDIS, future edition 1 of IEC 60901:1996/A6:2014, prepared by
IEC/SC 34A "Lamps" of IEC/TC 34 "Lamps and related equipment" was submitted to the IEC-
CENELEC parallel vote and approved by CENELEC as EN 60901:1996/A6:2017.
A draft amendment, which covers common modifications to IEC 60901:1996/A6:2014, was prepared
by CLC/TC 34A, "Lamps" and approved by CENELEC.
The following dates are fixed:
– latest date by which this document has to be implemented at (dop) 2018-08-16
national level by publication of an identical
national standard or by endorsement
– latest date by which the national standards conflicting with this (dow) 2020-08-16
document have to be withdrawn
Clauses, subclauses, notes, tables, figures and annexes which are additional to those in
IEC 60901:1996/A6:2014 are prefixed “Z”.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.
This document has been prepared under a mandate given to CENELEC by the European Commission
and the European Free Trade Association, and supports essential requirements of EU Directive(s).
For the relationship with EU Directive(s) see informative Annexes ZZ, which are an integral part of this
document.
This standard provides test methods related to parameters as prescribed by EC Regulation 245/2009,
and EU Regulation 874/2012 while conformity assessment (sampling, conformity procedures as well
as limits) for market surveillance are specified in the text of the above Regulations.
2

---------------------- Page: 4 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017

Endorsement notice
The text of the International Standard IEC 60901:1996/A6:2014 was approved by CENELEC as a
European Standard with agreed common modifications.
CONTENTS Add the following annexes:
Annex ZA (normative) Normative references to international publications with
their corresponding European publications
Annex ZZA (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EC) No 245/2009
Annex ZZB (informative) Relationship between this European Standard and the
requirements of Commission Regulation (EU) No 874/2012

1.2.Z1 Add the following subclause before 1.3
1.2.Z1 Overall statement
Where a Commission Regulation specifies limits for parameters these limits shall be
used instead of the limits specified in this standard.
3.Z1 After 1.4.12 add new definitions 1.4.Z1 up to 1.4.Z3:
1.4.Z1
efficacy
‘luminous efficacy of a source’, ‘light source efficacy’ or ‘lamp efficacy’ (η )
source
quotient of the luminous flux emitted (Ф) by the power consumed by the source
(Psource). ηsource = Ф / Psource. Unit: lm/W
Note 1 to entry: The power dissipated by auxiliary equipment such as ballasts is not included in the
power consumed by the source.
[SOURCE: Regulation 245/2009 Annex II, 1.a)]
1.4.Z2
lamp lumen maintenance factor (LLMF)
ratio of the luminous flux emitted by the lamp at a given time in its life to the initial
luminous flux
[SOURCE: Regulation 245/2009 Annex II, 1.b)]
1.4.Z3
lamp survival factor (LSF)
fraction of the total number of lamps which continue to operate at a given time under
defined conditions and switching frequency
[SOURCE: Regulation 245/2009 Annex II, 1.c)]
1.5.7 Before the text in 1.5.7, add a new header 1.5.7.Z1
1.5.7.Z1 General
After 1.5.7.Z1 add new subclauses 1.5.7.Z2 and 1.5.7.Z3
1.5.7.Z2 Chromaticity, correlated colour temperature and colour rendering index
The chromaticity coordinates and correlated colour temperature of an individual lamp
shall be calculated according to CIE 15 from a measurement made under the
conditions of Annex B.
The colour rendering index of an individual lamp shall be calculated according to
CIE 13.3 from a measurement made under the conditions of Annex B.
3

---------------------- Page: 5 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017 (E)

1.5.7.Z3 Efficacy
The efficacy of an individual lamp shall be calculated from a measurement of luminous
flux and power according to the conditions of Annex B.
1.5.8 Replace 1.5.8 with new subclauses 1.5.8.Z1 and 1.5.8. Z2
1.5.8.Z1 Lamp lumen maintenance factor
The lamp lumen maintenance factor of an individual lamp shall be calculated from
measurements of its luminous flux made at appropriate times according to the
conditions of Annex B. Lamp operation between these measurements shall be as
prescribed in Annex C.
1.5.8.Z2 Lamp survival
The survival of an individual lamp shall be determined by operating lamps under the
conditions prescribed in Annex C until the lamp fails to remain alight or delivers low
light output (in case of doubt, low light output refers to noticeably less than 50 % of
rated light output).
1.5.Z1 After 1.5.10 add a new subclause 1.5.Z1
1.5.Z1 Mercury content
The average mercury content shall be measured in accordance with the CV AAS
method as described in EN 62321-4. Lamp sample preparation shall be in accordance
with EN 62554.
Photometric characteristics shall be measured in accordance with EN 13032-1. For
determination of the centre beam intensity of reflector lamps, EN 61341 shall be used.
Bibliography After 1.7 Add
Biblography
COMMISSION REGULATION (EC) No 245/2009 of 18 March 2009 implementing
Directive 2005/32/EC of the European Parliament and of the Council with regard to
ecodesign requirements for fluorescent lamps without integrated ballast, for high
intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,
and repealing Directive 2000/55/EC of the European Parliament and of the Council
COMMISSION REGULATION (EU) No 874/2012 of 12 July 2012 supplementing
Directive 2010/30/EU of the European Parliament and of the Council with regard to
energy labelling of electrical lamps and luminaires

- - - - -
4

---------------------- Page: 6 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017

Annex ZA
(normative)

Normative references to international publications
with their corresponding European publications

The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.

NOTE 1 When an International Publication has been modified by common modifications, indicated by (mod), the relevant
EN/HD applies.

NOTE 2 Up-to-date information on the latest versions of the European Standards listed in this annex is available here:
www.cenelec.eu
Publication Year Title EN/HD Year
 Light and lighting – Measurement and EN 13032-1 2004
presentation of photometric data of lamps and
A1 2012
luminaires – Part 1: Measurement and file
format
IEC 60050-845 1987 International Electrotechnical Vocabulary – - -
Chapter 845: Lighting
IEC 60061-1 1969 Lamp caps and holders together with gauges EN 60061-1 1993
for the control of interchangeability and safety
– Part 1: Lamp caps
IEC 60081 1997 Double-capped fluorescent lamps – EN 60081 1998
Performance specifications
IEC 60155 1993 Luminaires – Part 1: General requirements EN 60155 1995
and tests
IEC 60598-1 1996 Luminaires – General requirements and tests EN 60598-1 1997
IEC 60921 1988 Ballasts for tubular fluorescent lamps – EN 60921 1991
Performance requirements
IEC 60927 1996 Auxiliaries for lamps – Starting devices (other EN 60927 1996
than glow starters) – Performance
requirements
IEC 60929 1990 AC supplied electronic ballasts for tubular EN 60929 1992
fluorescent lamps – Performance
requirements
IEC 61199 1993 Single-capped fluorescent lamps – Safety EN 61199 1994
specifications
IEC/TS 61231 1999 International lamp coding system (ILCOS) -
IEC 62321-4 - Determination of certain substances in EN 62321-4 -
electrotechnical products -
Part 4: Mercury in polymers, metals and
electronics by CV-AAS, CV-AFS, ICP-OES
and ICP-MS
IEC 62554 - Sample preparation for measurement of EN 62554 -
mercury level in fluorescent lamps

5

---------------------- Page: 7 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017 (E)

Annex ZZA
(informative)

Relationship between this European Standard and the eco-design
requirements of Commission Regulation (EC) No 245/2009 aimed to be covered

This European Standard has been prepared under a Commission’s standardization request M/495 to
provide one voluntary means of conforming to the ecodesign requirements of Commission Regulation
(EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament
and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated
ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps,
and repealing Directive 2000/55/EC of the European Parliament and of the Council [2009 OJ L76].
Once this standard is cited in the Official Journal of the European Union under that Commission
Regulation, compliance with the clauses of this standard given in Table ZZA.1 confers, within the limits
of the scope of this standard, a presumption of conformity with the corresponding ecodesign
requirements of that Regulation and associated EFTA regulations.
Table ZZA.1 – Correspondence between this European Standard and Commission
Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the
European Parliament and of the Council with regard to ecodesign requirements for
fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for
ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of
the European Parliament and of the Council [2009 OJ L76] and Commission’s
standardization request M/495
Ecodesign requirement of Clause(s) / subclause(s) Remarks / Notes
Regulation (EC) No 245/2009
of this EN
[2009 OJ L76]

Annex III, article 1.1 and article Annex B  Lamp power
1.3(a)
Annex III, article 1.1 and article Annex B Luminous flux
1.3(b)
Annex III, Table 12 and article Clause 1.5.8.Z2 Lamp survival factor (LSF)
1.3(e)
Annex III, Table 11 and article Clause 1.5.8.Z1 Lamp lumen maintenance
1.3(d) factor (LLMF)
Annex I, articles 1(a) and 1(f) Clause 1.5.7.Z2 Chromaticity coordinates (x,
y)
Annex III, Table 6, article 1.2 Clause 1.5.7.Z2 Colour rendering index (CRI)
and article 1.3(g)
Annex III, Table 6 and article Clause 1.5.7.Z2 Correlated colour temperature
1.3(h) (CCT)
Annex I, articles 1(f) Clause 1.5.2 Caps
Annex III article 1.3(f) Clause 1.5.Z1 Mercury content

WARNING 1 — Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2 — Other Union legislation may be applicable to the products falling within the scope of
this standard.
6

---------------------- Page: 8 ----------------------

SIST EN 60901:2001/A6:2019
EN 60901:1996/A6:2017

Annex ZZB
(informative)

Relationship between this European Standard and the energy labelling
requirements of Commission Delegated Regulation (EU) No 874/2012 aimed to
be covered

This European Standard has been prepared under a Commission’s standardisation request M/495 to
provide one voluntary means of conforming to the energy labelling requirements of Commission
Delegated Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the
European Parliament and of the Council with regard to energy labelling of electrical lamps and
luminaires [2012 OJ L258].
Once this standard is cited in the Official Journal of the European Union under that Commission
Regulation, compliance with the clauses of this standard given in Table ZZC.1 confers, within the limits
of the scope of this standard, a presumption of conformity with the corresponding energy labelling
requirements of that Regulation and associated EFTA regulations.
Table ZZB.1 – Correspondence between this European Standard and Commission
Regulation (EU) No 874/2012 of 12 July 2012 supplementing Directive 2010/30/EU of the
European Parliament and of the Council with regard to energy labelling of electrical lamps
and luminaires [2012 OJ L258] and Commission’s standardisation request M/495
Energy labelling requirement Clause(s) / subclause(s) Remarks / Notes
of Regulation (EU) No
of this EN
874/2012

[2012 OJ L258]
Article 1
Applicable parameter
Annex B
according to Article 1
luminous flux
Annex VII Annex B Lamp power
Annex VII Annex B Luminous flux

WARNING 1: Presumption of conformity stays valid only as long as a reference to this European
Standard is maintained in the list published in the Official Journal of the European Union. Users of this
standard should consult frequently the latest list published in the Official Journal of the European
Union.
WARNING 2: Other Union legislation may be applicable to the products falling within the scope of this
standard.

7

---------------------- Page: 9 ----------------------

SIST EN 60901:2001/A6:2019

---------------------- Page: 10 ----------------------

SIST EN 60901:2001/A6:2019



IEC 60901

®


Edition 2.0 2014-12




INTERNATIONAL



STANDARD




NORME



INTERNATIONALE




A MENDMENT 6

AM ENDEMENT 6





Single-capped fluorescent lamps – Performance specifications



Lampes à fluorescence à culot unique – Prescriptions de performances



















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX XD


ICS 29.140.30 ISBN 978-2-8322-1992-8



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 11 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014
FOREWORD
This amendment has been prepared by subcommittee 34A: Lamps, of IEC technical
committee 34: Lamps and related equipment.
The text of this amendment is based on the following documents:
FDIS Report on voting
34A/1801/FDIS 34A/1825/RVD

Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC website under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.


_____________

---------------------- Page: 12 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014
INSTRUCTIONS POUR L’INSERTION DES INSTRUCTIONS FOR THE

NOUVELLES PAGES ET FEUILLES INSERTION OF NEW PAGES
DE CARACTÉRISTIQUES DANS LA AND DATA SHEETS
PUBLICATION 60901 IN PUBLICATION 60901
----------------------- -----------------------
1. Retirer la page B-5 et insérer la nouvelle 1. Remove page B-6 and insert new page

page B-5. B-6.
2. Insérer les nouvelles pages D-3 et D-5. 2. Insert new pages D-4 and D-6.
3. Remplacer les feuilles de caractéristiques : 3. Replace the lamp data sheets :

2005-3 (page 3) par 2005-4 (page 3)
2005-3 (page 3) with 2005-4 (page 3)
 2005-1 (page 4)
 2005-1 (page 4)
2007-3 (page 3) par 2007-4 (page 3)
2007-3 (page 3) with 2007-4 (page 3)
 2007-1 (page 4)
 2007-1 (page 4)
2009-3 (page 3) par 2009-4 (page 3)
2009-3 (page 3) with 2009-4 (page 3)
 2009-1 (page 4)
 2009-1 (page 4)
2011-3 (page 3) par 2011-4 (page 3)
2011-3 (page 3) with 2011-4 (page 3)
 2011-1 (page 4)
 2011-1 (page 4)
2218-3 (page 3) par 2218-4 (page 3)
2218-3 (page 3) with 2218-4 (page 3)
 2218-1 (page 4)
 2218-1 (page 4)
2224-3 (page 3) par 2224-4 (page 3)
2224-3 (page 3) with 2224-4 (page 3)
 2224-1 (page 4)
 2224-1 (page 4)
2236-3 (page 3) par 2236-4 (page 3)
2236-3 (page 3) with 2236-4 (page 3)
 2236-1 (page 4)
 2236-1 (page 4)
2510-3 (page 3) par 2510-4 (page 3)
2510-3 (page 3) with 2510-4 (page 3)
 2510-1 (page 4)
 2510-1 (page 4)
2513-3 (page 3) par 2513-4 (page 3)
2513-3 (page 3) with 2513-4 (page 3)
 2513-1 (page 4)
 2513-1 (page 4)
2518-3 (page 3) par 2518-4 (page 3)
2518-3 (page 3) with 2518-4 (page 3)
 2518-1 (page 4)
 2518-1 (page 4)
2526-3 (page 3) par 2526-4 (page 3)
2526-3 (page 3) with 2526-4 (page 3)
 2526-1 (page 4)
 2526-1 (page 4)
3016-1 (page 3) par 3016-2 (page 3)
3016-1 (page 3) with 3016-2 (page 3)
 3016-1 (page 4)
 3016-1 (page 4)
3021-1 (page 3) par 3021-2 (page 3)
3021-1 (page 3) with 3021-2 (page 3)
 3021-1 (page 4)
 3021-1 (page 4)
3028-1 (page 3) par 3028-2 (page 3)
3028-1 (page 3) with 3028-2 (page 3)
 3028-1 (page 4)
 3028-1 (page 4)
3038-1 (page 3) par 3038-2 (page 3)
3038-1 (page 3) with 3038-2 (page 3)
 3038-1 (page 4)
 3038-1 (page 4)
3118-3 (page 3) par 3118-4 (page 3)
3118-3 (page 3) with 3118-4 (page 3)
 3118-1 (page 4)
 3118-1 (page 4)
3124-3 (page 3) par 3124-4 (page 3)
3124-3 (page 3) with 3124-4 (page 3)
 3124-1 (page 4)
 3124-1 (page 4)
3136-3 (page 3) par 3136-4 (page 3)
3136-3 (page 3) with 3136-4 (page 3)
 3136-1 (page 4)
 3136-1 (page 4)
3413-3 (page 3) par 3413-4 (page 3)
3413-3 (page 3) with 3413-4 (page 3)
 3413-1 (page 4)
 3413-1 (page 4)
3418-3 (page 3) par 3418-4 (page 3)
3418-3 (page 3) with 3418-4 (page 3)
 3418-1 (page 4)
 3418-1 (page 4)
3426-3 (page 3) par 3426-4 (page 3)
3426-3 (page 3) with 3426-4 (page 3)
 3426-1 (page 4)
 3426-1 (page 4)
6014-1 (page 2) par 6014-2 (page 2)
6014-1 (page 2) with 6014-2 (page 2)
6014-1 (page 3)
6014-1 (page 3)
6017-1 (page 2) par 6017-2 (page 2)
6017-1 (page 2) with 6017-2 (page 2)
6017-1 (page 3)
6017-1 (page 3)
6240-2 (page 1) par 6240-3 (page 1)
6240-2 (page 1) with 6240-3 (page 1)
6240-3 (page 2) par 6240-4 (page 2)
6240-3 (page 2) with 6240-4 (page 2)
 6240-1 (page 3)
 6240-1 (page 3)

---------------------- Page: 13 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014
6255-2 (page 1) par 6255-3 (page 1)
6255-3 (page 2) par 6255-4 (page 2) 6255-2 (page 1) with 6255-3 (page 1)
 6255-1 (page 3) 6255-3 (page 2) with 6255-4 (page 2)
6280-1 (page 1/2) par 6280-2 (page 1/2)  6255-1 (page 3)
 6280-1 (page 3) 6280-1 (page 1/2) with 6280-2 (page 1/2)
6722-1 (page 1) par 6722-2 (page 1)  6280-1 (page 3)
6722-2 (page 2) par 6722-3 (page 2) 6722-1 (page 1) with 6722-2 (page 1)
 6722-1 (page 3) 6722-2 (page 2) with 6722-3 (page 2)
6740-1 (page 1) par 6740-2 (page 1)  6722-1 (page 3)
6740-2 (page 2) par 6740-3 (page 2) 6740-1 (page 1) with 6740-2 (page 1)
 6740-1 (page 3) 6740-2 (page 2) with 6740-3 (page 2)
6755-1 (page 1) par 6755-2 (page 1)  6740-1 (page 3)
6755-2 (page 2) par 6755-3 (page 2) 6755-1 (page 1) with 6755-2 (page 1)
 6755-1 (page 3) 6755-2 (page 2) with 6755-3 (page 2)
6760-1 (page 1) par 6760-2 (page 1)  6755-1 (page 3)
6760-2 (page 2) par 6760-3 (page 2) 6760-1 (page 1) with 6760-2 (page 1)
 6760-1 (page 3) 6760-2 (page 2) with 6760-3 (page 2)
7432-2 (page 1) par 7432-3 (page 1)  6760-1 (page 3)
7432-4 (page 2) par 7432-5 (page 2) 7432-2 (page 1) with 7432-3 (page 1)
 7432-1 (page 3) 7432-4 (page 2) with 7432-5 (page 2)
7442-2 (page 1) par 7442-3 (page 1)  7432-1 (page 3)
7442-4 (page 2) par 7442-5 (page 2) 7442-2 (page 1) with 7442-3 (page 1)
 7442-1 (page 3) 7442-4 (page 2) with 7442-5 (page 2)
7456-1 (page 1) par 7456-2 (page 1)  7442-1 (page 3)
7456-2 (page 2) par 7456-3 (page 2) 7456-1 (page 1) with 7456-2 (page 1)
 7456-1 (page 3) 7456-2 (page 2) with 7456-3 (page 2)
7457-1 (page 1) par 7457-2 (page 1)  7456-1 (page 3)
7457-2 (page 2) par 7457-3 (page 2) 7457-1 (page 1) with 7457-2 (page 1)
 7457-1 (page 3) 7457-2 (page 2) with 7457-3 (page 2)
7469-1 (page 1/2) par 7469-2 (page 1/2)  7457-1 (page 3)
 7469-1 (page 3) 7469-1 (page 1/2) with 7469-2 (page 1/2)
7470-1 (page 1/2) par 7470-2 (page 1/2)  7469-1 (page 3)
 7470-1 (page 3) 7470-1 (page 1/2) with 7470-2 (page 1/2)
7660-1 (page 1/2) par 7660-2 (page 1/2)  7470-1 (page 3)
7685-1 (page 1/2) par 7685-2 (page 1/2) 7660-1 (page 1/2) with 7660-2 (page 1/2)
7719-1 (page 1/2) par 7719-2 (page 1/2) 7685-1 (page 1/2) with 7685-2 (page 1/2)
 7720-1 (page 1/2) par 7720-2 (page 1/2 7719-1 (page 1/2) with 7719-2 (page 1/2)
7720-1 (page 1/2) with 7720-2 (page 1/2)

----------------------- -----------------------

---------------------- Page: 14 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014 – B-6 –


B.2.2 Lamps for operation on a.c. mains frequencies
The voltage at the cathode terminals shall be adjusted to the value of the test voltage given
on the relevant lamp data sheet, and the current shall be measured. From these, after
deduction of the consumption of the voltmeter, the cathode resistance shall be determined.
B.2.3 Lamps for operation on high frequencies
The current flowing through the cathode shall be adjusted to the value of the test current
given on the relevant lamp data sheet, and the voltage drop over the cathode shall be
measured. From these the cathode resistance shall be calculated.
To determine the resistance of the lead wires, take 5 lamps of the type to be measured. Crack
off the end of the tubes carefully. Using a shorting link, short out the coil by clipping to the coil
clamps. Drive a current of 100 mA through the leads. Measure the voltage at the normally
used measurement point and calculate the lead resistance. The resulting value of the mean
lead resistance may be used for any further measurements with lamps of the same mount
construction.

---------------------- Page: 15 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014 – D-4 –


D.6 Maximum asymmetric power
The control gear shall have adequate protection to prevent lamp cap overheating at the end of
the lamp life cycle.
Values of maximum electrode power according to Table D.1 apply.
Table D.1 – Maximum asymmetric power
Maximum
Nominal
Sheet number asymmetric
power Shape Cap
60901-IEC- power
W
W
0005 5 Dual G23 5
0007 7 Dual G23 5
0009 9 Dual G23 5
0011 11 Dual G23 5
0013 13 Dual GX23 5
0510 10 Quad G24d-1 5
0513 13 Quad G24d-1 5
0518 18 Quad G24d-2 5
0526 26 Quad G24d-3 5
0715 15 Quad GX32d-1 5
0720 20 Quad GX32d-2 5
0727 27 Quad GX32d-3 5
1413 13 Multilimbed GX24d-1 5
1418 18 Multilimbed GX24d-2 5
1426 26 Multilimbed GX24d-3 5
2005 5 Dual 2G7 5
2007 7 Dual 2G7 5
2009 9 Dual 2G7 5
2011 11 Dual 2G7 5
2127 27 Dual GY10q-4 10
2128 28 Dual GY10q-5 10
2130 30 Dual GY10q-4 10
2136 36 Dual GY10q-6 10
2218 18 Dual 2G11 7,5
2224 24 Dual 2G11 7,5
2236 36 Dual 2G11 7,5
2510 10 Quad G24q-1 5
2513 13 Quad G24q-1 5
2518 18 Quad G24q-2 5
2526 26 Quad G24q-3 5
2613 13 Quad GX10q-2 7,5
2618 18 Quad GX10q-3 7,5
2627 27 Quad GX10q-4 7,5
3010 10 Square GR10q 5
3016 16 Square GR10q 5
3021 21 Square GR10q 5
3028 28 Square GR10q 7,5
3038 38 Square GR10q 7,5
3118 18 Square 2G10 7,5
3124 24 Square 2G10 7,5
3136 36 Square 2G10 7,5
3222 22 Circular G10q 10
3232 32 Circular G10q 10
3240 40 Circular G10q 10

---------------------- Page: 16 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014 – D-6 –


Maximum
Nominal
Sheet number asymmetric
power Shape Cap
60901-IEC- power
W
W
3413 13 Multilimbed GX24q-1 5
3418 18 Multilimbed GX24q-2 5
3426 26 Multilimbed GX24q-3 5
4224 24/27 Dual 2G11 7,5
4236 36/39 Dual 2G11 7,5
5010 10 Square GR10q 5
5016 16 Square GR10q 5
5021 21 Square GR10q 5
5028 28 Square GR10q 7,5
5038 38 Square GR10q 7,5
5222 22 Circular G10q 10
5232 32 Circular G10q 10
5240 40 Circular G10q 10
6014 14 Multilimbed GR14q-1 5
6017 17 Multilimbed GR14q-1 5
6240 40 Dual 2G11 7,5
6255 55 Dual 2G11 7,5
6280 80 Dual 2G11 7,5
6722 42 Circular 2GX13 7,5
6740 40 Circular 2GX13 7,5
6755 55 Circular 2GX13 7,5
6760 60 Circular 2GX13 7,5
6820 20 Circular GZ10q 7,5
6827 27 Circular GZ10q 7,5
6834 34 Circular GZ10q 7,5
6841 41 Circular GZ10q 7,5
6941 41 Circular GU10q 10
6968 68 Circular GU10q 10
6997 97 Circular GU10q 10
7432 32 Multilimbed GX24q-3 5
7442 42 Multilimbed GX24q-4 5
7456 57 Multilimbed-6 GX24q-5 5
7457 57 Multilimbed-8 GX24q-5 5
7469 70 Multilimbed-6 GX24q-6 5
7470 70 Multilimbed-8 GX24q-6 5
7660 60 Multilimbed-6 2G8-1 7,5
7685 85 Multilimbed-6 2G8-1 7,5
7719 120 Multilimbed-6 2G8-1 7,5
7720 120 Multilimbed-8 2G8-1 7,5
7862 62 Multilimbed-8 2G8-2 7,5
7882 82 Multilimbed-8 2G8-2 7,5

---------------------- Page: 17 ----------------------

SIST EN 60901:2001/A6:2019
IEC 60901:1996/AMD6:2014 © IEC 2014

SINGLE-CAPPED FL UORESCENT LAMP

Page 3

DATA SH EET


Dual-shaped

ILCOS: FSD-5-E-2G7

Information for high frequency ballast design

HF measurement ballast characteristics
Frequency Nominal power Rated voltage Calibration current Resistance
kHz W V A

20 - 26 5 54 0,190 140
Typical lamp characteristics
Frequency Lamp wattage Lamp voltage Lamp current
kHz W V A
5 27 0,190
≥ 20
Normal and dimming operation
Frequency kHz
≥ 20
Transition current from normal to dimming operation A I 0,100
Dtrans
Maximum lamp operating current A I 0,190
Dmax
Maximum current in any lead to cathodes A I 0,210
LHmax
Dimming ballast qualification with substitution resistors (Note 1)
Electrode heating with arbitrary lamp operating current, measured on substitution resistors
2
Parameters for minimum sum of squares lead currents to substitution resistor A X 0,030
1
2 2
(SoS ): I + I = X – Y I for I < I ≤ I (Note 2) A Y 0,240
min LH LL 1 1 D D30 D trans 1
Electrode heating at the specified operating currents, measured on substitution resistors
Operating current Heating parameters
Minimum cathode voltage V CV 6
...

Questions, Comments and Discussion