13.300 - Protection against dangerous goods
Protection against dangerous goods
Schutz vor gefahrlichen Gutern
Protection contre les matieres dangereuses
Varstvo pred nevarnimi izdelki
General Information
This European Standard contains terms and definitions applications to CBRNE.
Common understanding and communication is important in the implementation of an effective CBRNE response and this communication will be most effective if there is common understanding of the terms used. Many of the terms and definitions listed here have been widely used for many years, while others are the result of cross-cutting experience of areas of CBRNE. The gradual evolution of our understanding of CBRNE and resp...view more
- Standard101 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft103 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements for the design and construction of metallic gravity-discharge tanks intended for the carriage of substances having a vapour pressure not exceeding 110 kPa (1,1 bar) (absolute pressure) at 50 °C.
NOTE 1 Gravity discharge tanks have no maximum working pressure. However, during operation, pressure in the shell may occur, for example due to flow restrictions in vapour recovery systems or opening pressures of breather devices. It is important that these operating...view more
- Standard95 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft101 pagesEnglish language
sale 10% off- e-Library read for1 day
EN-ISO 16106 gives guidance on the application of a quality management system in the manufacture, measuring and monitoring of design type approved dangerous goods packaging, intermediate bulk containers (IBCs) and large packaging.This document does not include guidance specific to other management systems, such as those for environmental management, occupational health and safety management, or financial management.$0$0It is applicable to an organization that) needs to demonstrate its ability to...view more
- Standard67 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft62 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530 1 and EN 13530 2 apply.
Design and construction of pressure tanks acc...view more
- Corrigendum2 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This document includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530 1 and EN 13530 2 apply.
Design and construction of pressure tanks acc...view more
- Corrigendum2 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the following points regarding the minimum requirements for an overfill prevention system:
- functions;
- major components;
- characteristics;
- test methods.
This document is applicable to overfill prevention systems for liquid fuels having a flash point up to but not exceeding 100 °C, excluding liquefied petroleum gas (LPG).
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft35 pagesEnglish language
sale 10% off- e-Library read for1 day
This document gives guidance on the application of a quality management system in the manufacture, measuring and monitoring of design type approved dangerous goods packaging, intermediate bulk containers (IBCs) and large packaging.
This document does not include guidance specific to other management systems, such as those for environmental management, occupational health and safety management, or financial management.
It is applicable to an organization that:
a) needs to demonstrate its abili...view more
- Standard67 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft62 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the following points regarding the minimum requirements for an overfill prevention system:
- functions;
- major components;
- characteristics;
- test methods.
This document is applicable to overfill prevention systems for liquid fuels having a flash point up to but not exceeding 100 °C, excluding liquefied petroleum gas (LPG).
NOTE Vapour path detection is not part of this standard but can be provided as an option.
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft35 pagesEnglish language
sale 10% off- e-Library read for1 day
This document gives guidance on the application of a quality management system in the manufacture, measuring and monitoring of design type approved dangerous goods packaging, intermediate bulk containers (IBCs) and large packaging. This document does not include guidance specific to other management systems, such as those for environmental management, occupational health and safety management, or financial management. It is applicable to an organization that: a) needs to demonstrate its ability ...view more
- Standard55 pagesFrench language
sale 15% off- Standard55 pagesEnglish language
sale 15% off
This Standard provides additional terms and definitions to those written in the European Agreement Concerning the International Carriage of Dangerous Goods by Road (ADR) or the Regulations concerning the International Carriage of Dangerous Goods by Rail (RID), appearing as Appendix C to the Convention concerning International Carriage by Rail (COTIF). This document forms part of series of documents prepared by CEN/TC 296 regarding the transport of dangerous goods. The series supports the proper ...view more
- Standard39 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft43 pagesEnglish language
sale 10% off- e-Library read for1 day
This document provides additional terms and definitions to those written in the European Agreement Concerning the International Carriage of Dangerous Goods by Road (ADR) or the Regulations concerning the International Carriage of Dangerous Goods by Rail (RID), appearing as Appendix C to the Convention concerning International Carriage by Rail (COTIF).
This document forms part of series of documents prepared by CEN/TC 296 regarding the transport of dangerous goods. The series supports the proper...view more
- Standard39 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft43 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the product characteristics and test/assessment methods for workshop
fabricated cylindrical, horizontal steel tanks, single (type S) and double skin (type D) intended to be
used for the underground storage of water polluting liquids (both flammable and non-flammable),
specifically used for storage and/or supply of fuel for building heating/cooling systems, and of hot or
cold water not intended for human consumption at normal ambient temperature conditions (−20 °C to
...view more
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the product characteristics and test/assessment methods for workshop fabricated cylindrical, horizontal steel tanks, single (type S) and double skin (type D) intended to be used for the underground storage of water polluting liquids (both flammable and non-flammable), specifically used for storage and/or supply of fuel for building heating/cooling systems, and of hot or cold water not intended for human consumption at normal ambient temperature conditions (−20 °C to +50 °...view more
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies material parameters, test requirements and procedures for the comparative testing of grades of high molecular weight high density polyethylene (PE-HD-HMW) and medium molecular weight high density polyethylene (PE-HD-MMW), used for the manufacture of packagings and IBCs for the transport of dangerous goods. It is intended to be used in conjunction with selective testing for packagings for liquids. The standard is not intended to be used for comparative testing of ...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the minimum performance and construction requirements for overfill prevention controllers located on the tank vehicle.
This European Standard applies to overfill prevention controllers for liquid fuels, having a flash point up to but not exceeding 100 °C.
The requirements apply to overfill prevention controllers suitable for use at ambient temperatures in the range from 25 °C to +60 °C, and subject to normal operational pressure variations.
- Standard15 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies testing, inspection and marking for the type approval, initial inspection, periodic inspection, intermediate inspection and exceptional check of metallic tanks (shell and equipment) of fixed tanks (tank vehicles), demountable tanks, rail tank wagons, portable tanks and tank containers for the transport of dangerous goods.
This European Standard is not applicable to battery-vehicles and battery-wagons comprising cylinders, tubes, pressure drums, bundles of cylind...view more
- Standard65 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard covers the manhole cover assembly and specifies the performance requirements, dimensions and tests necessary to verify the compliance of the equipment to this standard.
The equipment specified by this standard is suitable for use with liquid petroleum products and other dangerous substances of Class 3 of ADR - European Agreement concerning the International Carriage of Dangerous Goods by Road - (flammable liquids) which have a vapour pressure not exceeding 110 kPa at 50 °...view more
- Standard14 pagesEnglish language
sale 10% off- e-Library read for1 day
This document covers the emergency pressure relief valve.
It specifies the performance requirements and the critical dimensions of the emergency pressure relief valve. It also specifies the tests necessary to verify the compliance of the equipment with this document.
The service equipment specified by this document is suitable for use with liquid petroleum products and other dangerous substances of Class 3 of ADR [2] which have a vapour pressure not exceeding 110 kPa at 50 oC and petrol, and w...view more
- Standard14 pagesEnglish language
sale 10% off- e-Library read for1 day
This document covers the vapour manifold vent valve used to provide controlled venting of the vapour manifold to atmosphere.
It specifies the performance requirements and the critical dimensions of the vapour manifold vent valve. It also specifies the tests necessary to verify compliance of the equipment with this document.
The service equipment specified by this document is suitable for use with liquid petroleum products and other dangerous substances of Class 3 of ADR [1] which have a vapour...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the minimum requirements for the design and construction of metallic pressure tanks having a maximum working or test pressure exceeding 50 kPa (0,5 bar), for the transport of dangerous goods by road and rail and sea. This European Standard includes requirements for openings, closures and structural equipment; it does not cover requirements of service equipment. For tanks for the transport of cryogenic liquids, EN 13530-1 and EN 13530-2 apply.
NOTE 1 Design and c...view more
- Standard61 pagesEnglish language
sale 10% off- e-Library read for1 day