The present document specifies test severities and methods for the verification of the required resistibility of equipment according to the relevant environmental class. The tests in Part 2-3 of this multi-part EN apply to stationary use of equipment at weatherprotected locations covering the environmental conditions stated in EN 300 019-1-3 [1].

Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 2-3. del: Specifikacija preskusov vplivov okolja – Fiksna uporaba na lokacijah, zaščitenih pred vremenskimi vplivi

General Information

Status
Published
Publication Date
31-Jan-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Standard

Standard
SIST EN 300 019-2-3 V2.2.1:2006
English language
31 pages
sale - 10%
Preview
sale - 10%
Preview

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 300 019-2-3 V2.2.1:2006
01-februar-2006
2NROMVNLLQåHQLULQJ (( ±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO6SHFLILNDFLMDSUHVNXVRYYSOLYRYRNROMD±
)LNVQDXSRUDEDQDORNDFLMDK]DãþLWHQLKSUHGYUHPHQVNLPLYSOLYL

Environmental Engineering (EE); Environmental conditions and environmental tests for

telecommunications equipment; Part 2-3: Specification of environmental tests; Stationary

use at weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-2-3 Version 2.2.1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-2-3 V2.2.1:2006 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
---------------------- Page: 2 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
ETSI EN 300 019-2-3 V2.2.1 (2003-03)
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-3: Specification of environmental tests;
Stationary use at weatherprotected locations
---------------------- Page: 3 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
2 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
Reference
REN/EE-01032-2-3
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org

The present document may be made available in more than one electronic version or in print. In any case of existing or

perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).

In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive

within ETSI Secretariat.

Users of the present document should be aware that the document may be subject to revision or change of status.

Information on the current status of this and other ETSI documents is available at

http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM

DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.

TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.

3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.

ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
3 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
Contents

Intellectual Property Rights................................................................................................................................4

Foreword.............................................................................................................................................................4

1 Scope........................................................................................................................................................5

2 References................................................................................................................................................5

3 Environmental test specifications.............................................................................................................5

3.1 Specifications T 3.1 and T 3.1 E: Temperature-controlled locations .................................................................6

3.2 Specification T 3.2: Partly temperature-controlled locations ...........................................................................10

3.3 Specification T 3.3: Not temperature-controlled locations...............................................................................13

3.4 Specification T 3.4: Sites with heat-trap ..........................................................................................................16

3.5 Specification T 3.5: Sheltered locations ...........................................................................................................19

3.6 Specifications T 3.6: Control room locations...................................................................................................22

4 Earthquake test specification..................................................................................................................25

4.1 Vibration response investigation ......................................................................................................................25

4.2 Test conditioning..............................................................................................................................................26

5 Notes to tables ........................................................................................................................................27

5.1 General note.....................................................................................................................................................27

5.2 Notes to tables 1 to 12 ......................................................................................................................................28

Annex A (informative): Bibliography...................................................................................................30

History ..............................................................................................................................................................31

ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
4 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
Intellectual Property Rights

IPRs essential or potentially essential to the present document may have been declared to ETSI. The information

pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found

in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in

respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web

server (http://webapp.etsi.org/IPR/home.asp).

All published ETSI deliverables shall include information which directs the reader to the above source of information.

Foreword

This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental

Engineering (EE).

The present document is part 2, sub-part 3 of a multi-part deliverable covering the classification of environmental

conditions and environmental tests for telecommunications equipment, as identified below:

Part 1: "Classification of environmental conditions"; (see note 1)
Part 2: "Specification of environmental tests"; (see note 2)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".

NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,

chemically and mechanically active substances and mechanical conditions during storage, transportation

and in use.

NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.

National transposition dates
Date of adoption of this EN: 21 March 2003
Date of latest announcement of this EN (doa): 30 June 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 December 2003
Date of withdrawal of any conflicting National Standard (dow): 31 December 2003
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
5 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
1 Scope

The present document specifies test severities and methods for the verification of the required resistibility of equipment

according to the relevant environmental class.

The tests in Part 2-3 of this multi-part EN apply to stationary use of equipment at weatherprotected locations covering

the environmental conditions stated in EN 300 019-1-3 [1].
2 References

The following documents contain provisions which, through reference in this text, constitute provisions of the present

document.

• References are either specific (identified by date of publication and/or edition number or version number) or

non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.

Referenced documents which are not found to be publicly available in the expected location might be found at

http://docbox.etsi.org/Reference.

[1] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and

environmental tests for telecommunications equipment; Part 1-3: Classification of environmental

conditions; Stationary use at weatherprotected locations".
[2] IEC 60068-2: "Environmental testing - Part 2: Tests".

[3] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and

environmental tests for telecommunications equipment; Part 2-0: Specification of environmental

tests; Introduction".

[4] IEC 60721-3-3: "Classification of environmental conditions - Part 3-3: Classification of groups of

environmental parameters and their severities - Stationary use at weatherprotected locations ".

3 Environmental test specifications

The detailed descriptions of the environmental conditions are in clauses 4 and 5 of EN 300 019-1-3 [1].

EN 300 019-2-0 [3] forms a general overview of part 2 of the present document.

The equipment under test is assumed to be in its operational state throughout the test conditions described in this part

unless otherwise stated. The required performance before, during and after the test needs to be specified in the product

specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment

under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be

minimized.
ETSI
---------------------- Page: 7 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
6 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
3.1 Specifications T 3.1 and T 3.1 E: Temperature-controlled locations

Specification T 3.1: Temperature-controlled locations - normal operating conditions.

This specification applies to permanently temperature-controlled enclosed locations where humidity is usually not controlled. See tables 1 and 2.

Table 1: Test specification T 3.1: Temperature-controlled locations - climatic tests

Environmental parameter Environmental Environmental test specification T3.1: In-use,

Class 3.1 Temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
High (°C) +40 +40 or +50 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
Air temperature
Change (°C) +25/+40 half cycle IEC 60068-2-14 [2] Nb: Change of 3
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 none 4
high (%) (°C) 85 85 4 d IEC 60068-2-56 [2] Cb: Damp heat 5
Relative
+30 steady state
Humidity
condensation no
1 none 4
low (g/m )
Absolute
25 7
high (g/m )
low (kPa) 70 none 8
Pressure
Air
high (kPa) 106 none 8
Speed (m/s) 5,0 none 4
intensity no
Rain
low temperature no
Water
Other sources no
Icing & frosting no
Solar 700 10
(W/m )
Radiation
Heat 600 11
(W/m )
ETSI
---------------------- Page: 8 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
7 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Environmental parameter Environmental Environmental test specification T3.1: In-use,

Class 3.1 Temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
0,3/1,0 none 12
SO (mg/m )
Sulphur
0,1/0,5 none 12
HS (mg/m )
salt mist sea and road salt none 12
0,1/0,3 none 12
Cl (mg/m )
Chlorine
0,1/0,5 none 12
Chemically active substances
HCI (mg/m )
0,5/1,0 none 12
NO (mg/m )
Nitrogen
1,0/3,0 none 12
NH (mg/m )
0,01/0,03 none 12
Hydrogen fluoride HF
(mg/m )
Ozone O 0,05/0,1 none 12
(mg/m )
sedimentation 1,5 none 12
Dust (mg/(m h))
Mechanically active substances
0,2 none 13
suspension (mg/m )
Sand 30 none 13
(mg/m )
Micro organisms negligible
Flora and fauna
Rodents, insects negligible
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
---------------------- Page: 9 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
8 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Table 2: Test specification T 3.1: Temperature-controlled locations - mechanical tests

Environmental parameter Environmental Environmental test specification T 3.1: In-use,

Class 3.1 Temperature-controlled locations

Type Parameter Detail Characteristic Test severity Duration Reference Method Notes

parameter severity (see clause 5)
Vibration Sinusoidal displacement (mm) 0,3 15
1,0 none
acceleration (m/s )
2-9 9-200
frequency range (Hz)
axes of vibration
Shocks Shocks shock spectrum Type L half sine IEC 60068-2-27 [2] Ea: Shock 18
duration (ms) 22 11
40 30
acceleration (m/s )
3 in each
number of shocks
6 direction
direction of shocks
NOTE 1: none = verification is required only in special cases
NOTE 2: n = number of note, see clause 5.

Specification T 3.1 E: Temperature-controlled locations - exceptional operating conditions.

This specification applies to permanently temperature-controlled locations where humidity is usually not controlled. The reference class is the same as for T 3.1, but the test

specification relates to reduced performance requirements. See table 3.
ETSI
---------------------- Page: 10 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
9 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Table 3: Test specification T 3.1 E: Temperature-controlled locations, exceptional operating conditions - climatic tests

Environmental parameter Environmental Environmental test specification T3.1E: In-use,

Class 3.1E Temperature-controlled locations - Exceptional.

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) -5 -5 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
High (°C) +45 +45 or +55 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
Air
temperature Change (°C) +25/+45 half cycle IEC 60068-2-14 [2] Nb: Change of 3
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 5 none 4
High (%) 90 93 4 d IEC 60068-2-56 [2] Cb: Damp heat 5
Relative
(°C) +30 steady state
Humidity
condensation no
1 none 4
low (g/m )
Absolute
25 7
high (g/m )
Solar 700 10
(W/m )
Radiation
Heat 600 11
(W/m )
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
---------------------- Page: 11 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
10 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
3.2 Specification T 3.2: Partly temperature-controlled locations

This specification applies to enclosed locations having neither temperature nor humidity control, but where heating may be used to avoid low temperatures. The building

construction avoids extremely high temperatures. See tables 4 and 5.

Table 4: Test specification T 3.2: Partly temperature-controlled locations - climatic tests

Environmental parameter Environmental Environmental test specification T3.2: In-use,

Class 3.2 Partly temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) -5 -5 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
High (°C) +45 +45 or +55 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
Air
temp range (°C) +25/+55 or half cycle IEC 60068-2-14 [2] Nb: Change of 3
temperature
Change +25/+45 t = 3 h temperature
rate (°C/min) 0,5 0,5
low (%) 5 none 4
high (%) 95 93 4 d IEC 60068-2-56 [2] Cb: Damp heat 5
(°C) +30 steady state
Relative
condensation yes IEC 60068-2-30 [2] Db: Damp heat 6
Humidity
(°C) +30° 1 cycle cyclic
(%) 90-100 Variant 1
1 none 4
Low (g/m )
Absolute
29 7
high (g/m )
low (kPa) 70 none 8
Pressure
Air
high (kPa) 106 none 8
Speed (m/s) 5,0 none 4
intensity no
Rain
low temperature no
Water
Other sources no
Icing & frosting yes 4
2 700 10
Solar
(W/m )
Radiation
600 11
Heat
(W/m )
ETSI
---------------------- Page: 12 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
11 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Environmental parameter Environmental Environmental test specification T3.2: In-use,

Class 3.2 Partly temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
0,3/1,0 none 12
SO (mg/m )
Sulphur
0,1/0,5 none 12
HS (mg/m )
salt mist sea and road salt none 12
0,1/0,3 none 12
Cl (mg/m )
Chlorine
Chemically
0,1/0,5 none 12
HCl (mg/m )
active
0,5/5,0 none 12
substances NO (mg/m )
Nitrogen
1,0/3,0 none 12
NH (mg/m )
Hydrogen fluoride 0,01/0,03 none 12
(mg/m )
Ozone O 3
0,05/0,1 none 12
3 (mg/m )
Sedimentation 15 13
Mechanically
Dust (mg/(m h))
active
0,4 13
suspension (mg/m )
substances
300 13
Sand
(mg/m )
Flora and Micro organisms mould, fungus, etc. none 14
fauna Rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
---------------------- Page: 13 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
12 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Table 5: Test specification T 3.2: Partly temperature-controlled locations - mechanical tests

Environmental parameter Environmental Environmental test specification T 3.2: In-use,

Class 3.2 Partly temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
velocity (mm/s) 5 IEC 60068-2-6 [2] Fc: Vibration 16
displacement (mm) 1,5 (sinusoidal)
5 2
Sinusoidal
acceleration (m/s )
2-9 9-200 5-62 62-200 3 x 5 sweep cycles
frequency range (Hz)
Vibration axes of vibration
2 3
0,02 IEC 60068-2-64 [2] Fh: Vibration, 17
ASD (m /s )
+12 -12 3 x 30 minutes broad-band
(dB/oct)
5-10 10-50 50-100 random
Random
frequency range (Hz)
3 (digital control)
axes of vibration
shock spectrum Type L half sine IEC 60068-2-27 [2] Ea: Shock 18
duration (ms) 22 11
40 30
Shocks Shocks
acceleration (m/s )
3 in each direction
number of shocks
directions of shocks
NOTE: n = number of note, see clause 5.
ETSI
---------------------- Page: 14 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
13 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
3.3 Specification T 3.3: Not temperature-controlled locations

This specification applies to weatherprotected or partially weatherprotected locations having neither temperature nor humidity control. See tables 6 and 7.

Table 6: Test specification T 3.3: Not temperature-controlled locations - climatic tests

Environmental parameter Environmental Environmental test specification T3.3: In-use,

Class 3.3 Not temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) -25 -25 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
High (°C) +55 +55 or +70 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
Air
temperature (°C) -5/+45 1 cycle IEC 60068-2-14 [2] Nb: Change of 3
Change
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 10 none 4
High (%) 100 93 4 d IEC 60068-2-56 [2] Cb: Damp heat 5
(°C) +30 steady state
Relative
condensation yes IEC 60068-2-30 [2] Db: Damp heat 6
(%) 90-100 2 cycles cyclic Variant 1
Humidity
(°C) +30
0,5 none 4
low (g/m )
Absolute
29 7
high (g/m )
low (kPa) 70 none 8
Pressure
Air
high (kPa) 106 none 8
Speed (m/s) 5,0 none 4
intensity wind driven 9
Rain
low temperature no
Water
Other sources dripping water 4
Icing & frosting yes 4
1 200 10
Solar
(W/m )
Radiation
600 11
Heat
(W/m )
ETSI
---------------------- Page: 15 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
14 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Environmental parameter Environmental Environmental test specification T3.3: In-use,

Class 3.3 Not temperature-controlled locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
0,3/1,0 none 12
SO (mg/m )
Sulphur
0,1/0,5 none 12
HS (mg/m )
salt mist sea and road salt none 12
0,1/0,3 none 12
Cl (mg/m )
Chlorine
Chemically
0,1/0,5 none 12
HCl (mg/m )
active
0,5/1,0 none 12
substances NO (mg/m )
Nitrogen
1,0/3,0 none 12
NH (mg/m )
Hydrogen fluoride 0,01/0,03 none 12
(mg/m )
Ozone O 3
0,05/0,1 none 12
3 (mg/m )
sedimentation 15 13
Mechanically
Dust (mg/(m h))
active
0,4 13
suspension (mg/m )
substances
300 13
Sand
(mg/m )
Flora and Micro organisms mould, fungus, etc. none 14
fauna Rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
---------------------- Page: 16 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
15 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Table 7: Test specification T 3.3: Not temperature-controlled locations - mechanical tests

Environmental parameter Environmental Environmental test specification T 3.3: In-use,

Class 3.3 Not temperature-controlled locations

Type Parameter Detail Characteristic Test severity Duration Reference Method Notes

parameter severity (see clause 5)
velocity (mm/s) 5 IEC 60068-2-6 [2] Fc: Vibration 16
displacement (mm) 1,5 (sinusoidal)
5 2
Vibration Sinusoidal
acceleration (m/s )
2-9 9-200 5-62 62-200 3 x 5 sweep
frequency range (Hz)
3 cycles
axes of vibration
2 3
0,02 IEC 60068-2-64 [2] Fh: Vibration, 17
ASD (m /s )
+12 -12 3 x 30 minutes broad-band
(dB/oct)
Random 5-10 10-50 50-100 random
frequency range (Hz)
3 (digital
axes of vibration
control)
shock spectrum Type L half sine IEC 60068-2-27 [2] Ea: Shock 18
duration (ms) 22 11
40 30
Shocks Shocks
acceleration (m/s )
3 in each direction
number of shocks
directions of shocks
NOTE: n = number of note, see clause 5.
ETSI
---------------------- Page: 17 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
16 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
3.4 Specification T 3.4: Sites with heat-trap

This specification applies to weatherprotected or partially weatherprotected locations having neither temperature nor humidity control. Solar radiation and heat-trap conditions

may cause high temperatures. See tables 8 and 9.
Table 8: Test specification T 3.4: Sites with heat-trap - climatic tests

Environmental parameter Environmental Environmental test specification T3.4: In-use,

Class 3.4 Sites with heat trap

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) -40 -40 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
High (°C) +70 +70 or +85 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
Air
(°C) -5/+45 2 cycles IEC 60068-2-14 [2] Nb: Change of 3
temperature
Change
(°C/min) 0,5 0,5 t = 3 h temperature
low (%) 10 none 4
high (%) 100 93 4 d IEC 60068-2-56 [2] Cb: Damp heat steady 5
(°C) +35 state
Relative
condensation yes 6
Humidity
(%) 90-100 2 cycles IEC 60068-2-30 [2] Db: Damp heat cyclic
(°C) +30 Variant 1
0,1 none 4
low (g/m )
Absolute
35 7
high (g/m )
low (kPa) 70 none 8
Pressure
Air high (kPa) 106 none 8
Speed (m/s) 5,0 none 4
intensity wind driven 9
Rain
low temperature no
Water
dripping and 4
Other sources
spraying water
Icing & frosting yes 4
1 200 10
solar
(W/m )
Radiation
600 11
heat (W/m )
ETSI
---------------------- Page: 18 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
17 ETSI EN 300 019-2-3 V2.2.1 (2003-03)

Environmental parameter Environmental Environmental test specification T3.4: In-use,

Class 3.4 Sites with heat trap

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
0,3/1,0 none 12
SO (mg/m )
Sulphur
0,1/0,5 none 12
HS (mg/m )
salt mist sea and road salt none 12
0,1/0,3 none 12
Cl (mg/m )
Chlorine
Chemically
0,1/0,5 none 12
HCl (mg/m )
Active
0,5/1,0 none 12
substances NO (mg/m )
Nitrogen
1,0/3,0 none 12
NH (mg/m )
Hydrogen fluoride 0,01/0,03 none 12
(mg/m )
Ozone O 3
0,05/0,1 none 12
3 (mg/m )
sedimentation 15 13
Chemically
Dust (mg/(m h))
active
0,4 13
suspension (mg/m )
substances
300 13
Sand
(mg/m )
Flora and Micro organisms mould, fungus, etc. none 14
fauna Rodents, insects rodents, etc. none 14
NOTE 1: no = this condition does not occur in this class.
NOTE 2: none = verification is required only in special cases.
NOTE 3: n = number of note, see clause 5.
ETSI
---------------------- Page: 19 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
18 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
Table 9: Test specification T 3.4: Sites with heat-trap - mechanical tests

Environmental parameter Environmental Environmental test specification T 3.4: Stationary use,

Class 3.4 Sites with heat-trap

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
displacement (mm) 3,0 1,2 IEC 60068-2-6 [2] Fc: Vibration 16, 19
Vibration
10 4 (sinusoidal)
acceleration (m/s )
IEC 60721-3-3 [4] Sinusoidal
2-9 9-200 5-9 9-200 3 x 5 sweep cycles
frequency range (Hz)
Class 3M5
axes of vibration
2 3
0,04 IEC 60068-2-64 [2] Fh: Vibration, 17, 19
ASD (m /s )
+12 -12 3 x 30 minutes broad-band
(dB/oct)
Random
5-10 10-50 50-100 random
frequency range (Hz)
3 (digital control)
axes of vibration
shock spectrum Type II half sine IEC 60068-2-29 [2] Eb: Bump 18, 19
duration (ms) 6 11
Shocks
250 50
IEC 60721-3-3 [4] Shocks
acceleration (m/s )
100 in each
Class 3M5
number of bumps
6 direction
directions of bumps
velocity (mm/s) 5 IEC 60068-2-6 [2] Fc: Vibration 16, 19
displacement (mm) 1,5 (sinusoidal)
Vibration
5 2 3 x 5 sweep cycles
IEC 60721-3-3 [4] Sinusoidal
acceleration (m/s )
2-9 9-200 5-62 62-200
Class 3M3
frequency range (Hz)
axes of vibration
2 3
0,02 IEC 60068-2-64 [2] Fh: Vibration, 17, 19
ASD (m /s )
+12 -12 3 x 30 minutes broad-band
(dB/oct)
Random
5-10 10-50 50-100 random
frequency range (Hz)
3 (digital control)
axes of vibration
shock spectrum Type L half sine IEC 60068-2-27 [2] Ea: Shock 18, 19
duration (ms) 22 11
Shocks
70 30
IEC 60721-3-3 [4] Shocks
acceleration (m/s )
3 in each direction
Class 3M3
number of shocks
directions of shocks
NOTE: n = number of note, see clause 5.
ETSI
---------------------- Page: 20 ----------------------
SIST EN 300 019-2-3 V2.2.1:2006
19 ETSI EN 300 019-2-3 V2.2.1 (2003-03)
3.5 Specification T 3.5: Sheltered locations

This specification applies to sheltered locations where direct solar radiation and heat-trap conditions do not exist. See tables 10 and 11.

Table 10: Test specification T 3.5: Sheltered locations - climatic tests

Environmental parameter Environmental Environmental test specification T3.5: In-use,

Class 3.5 Sheltered locations

Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes

severity (see clause 5)
Low (°C) -40 -40 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Air High (°C) +40 +40 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
temperature Change (°C) -40/+40 2 cycles IEC 60068-2-14 [2] Nb: Change of 3
(°C/min) 1,0 1,0 t = 3 h temperature
low (%) 10 none 4
high (%) 100 93 4 d IEC 60068-2-56 [2] C
...

Questions, Comments and Discussion