This document specifies the requirements for solid-wall styrene copolymer blend (SAN + PVC) pipes and fittings for soil and waste discharge (low and high temperature) above ground inside buildings, and for the system itself. It does not include buried pipework. It also specifies the test parameters for the test methods referred to within this document. This document is applicable to SAN + PVC pipes and fittings, as well as assemblies of such pipes and fittings, intended to be used for the following purposes: a) soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature); b) ventilation pipework associated with a); c) rainwater pipework inside the building. This document is applicable to pipes and fittings designed for jointing by means of elastomeric sealing rings, solvent cementing or integral dual-purpose sockets, i.e. for elastomeric ring seal joints and/or for solvent cement joints.

  • Standard
    30 pages
    English language
    sale 15% off
  • Draft
    30 pages
    English language
    sale 15% off

ISO/TS 7024:2005 gives the recommended practice for installation of thermoplastic piping systems in the field of soil and waste discharge (low and high temperature) inside buildings (marked with "B"). ISO/TS 7024:2005 is applicable to thermoplastic pipes and fittings as specified in the associated standards ISO 3633 (PVC-U), ISO 7671 (PP), ISO 7682 (ABS), ISO 8770 (PE-HD), ISO 19220 (SAN+PVC) and ISO 7675 (PVC-C), their joints and to joints with components of other plastic and non-plastic materials intended to be used for the following purposes: soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature); ventilating pipework associated with 1); rainwater pipework within the building structure. If specified in the relevant associated standard, ISO/TS 7024:2004 also covers soil and waste discharge pipework fixed externally on to the building. It is not applicable to pipework that passes under the building without any connection from the discharge system.

  • Technical specification
    42 pages
    English language
    sale 15% off
  • Technical specification
    43 pages
    French language
    sale 15% off

This International Standard specifies the requirements for unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings for soil and waste discharge (low and high temperature) inside buildings, as well as the system itself. It does not include buried pipework. It also specifies the test parameters for the test methods referred to in this International Standard. This International Standard is applicable to PVC-U pipes and fittings, as well as assemblies of such pipes and fittings, intended to be used for the following purposes: soil and waste discharge pipework for the conveyance of domestic waste waters (low and high temperature); ventilation pipework associated with 1; rainwater pipework inside the building.

  • Standard
    29 pages
    English language
    sale 15% off
  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    29 pages
    French language
    sale 15% off