oSIST prEN 1629:2019
(Main)Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
This document specifies a test method for the determination of resistance to dynamic loading in order to assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically) and rolling as well as fixed constructions.
It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer's installation instructions is given in Annex A of prEN 1627:2019.
This document does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241.
Türen, Fenster, Vorhangfassaden, Gitterelemente und Abschlüsse - Einbruchhemmung - Prüfverfahren für die Ermittlung der Widerstandsfähigkeit unter dynamischer Belastung
Dieses Dokument legt ein Prüfverfahren zur Ermittlung der Widerstandsfähigkeit unter dynamischer Belastung fest, um die einbruchhemmenden Eigenschaften von Türelementen, Fenstern, Vorhangfassaden, Gitterelementen und Abschlüssen zu bewerten. Sie gilt für die folgenden Öffnungsarten: Drehen, Kippen, Falten, Drehkippen, Hoch oder Herunterklappen, Schieben (horizontal und vertikal), Schwingen (horizontal und vertikal) und Rollen sowie für nicht öffenbare Konstruktionen.
Es werden zwei Aspekte der einbruchhemmenden Leistungsfähigkeit von Bauprodukten zugrundegelegt, ihr üblicher Widerstand gegen gewaltsamen Durchtritt und ihre Fähigkeit, im Gebäude fest verankert zu bleiben. Das vorliegende Prüfverfahren bewertet nicht die Ausführung der Befestigung am Gebäude.
Leitlinien zur Befestigung des Produkts sind der Einbauanweisung des Herstellers zu entnehmen.
prEN 1627:2019, Anhang A enthält ein Beispiel für den Inhalt der Einbauanweisung des Herstellers.
Dieses Dokument gilt nicht für Türen, Tore und Schranken, die für den Einbau in Zugangsbereichen von Personen vorgesehen sind und deren hauptsächlich vorgesehene Verwendung darin besteht, eine sichere Zufahrt für Waren und Fahrzeuge, begleitet oder geführt (gesteuert) von Personen, in industriellen, gewerblichen oder Wohnbereichen zu ermöglichen, was in EN 13241 behandelt wird.
Blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures - Résistance à l'effraction - Méthode d'essai pour la détermination de la résistance à la charge dynamique
Le présent document spécifie une méthode d’essai pour déterminer la résistance à la charge dynamique dans le but d’évaluer les caractéristiques de résistance à l’effraction des blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures. Il s’applique aux constructions fixes et aux systèmes ouvrants suivants : battant, oscillant, pliant, oscillo-battant, à gonds haut ou bas, coulissant (horizontalement et verticalement), pivotant (horizontalement et verticalement) et à enroulement.
Il est reconnu que les performances de résistance à l’effraction des produits de construction se caractérisent par deux aspects : la résistance normale à un forçage et la capacité à rester fixé au bâtiment. Cette méthode d’essai n’évalue pas les performances de la fixation au bâtiment.
Les instructions de pose du fabricant donneront des lignes directrices sur la fixation du produit.
Un exemple du contenu des instructions de pose du fabricant est donné dans l’Annexe A du prEN 1627:2019.
Le présent document ne s’applique pas aux portes, portails et barrières, destinés à être installés dans des zones accessibles aux personnes et dont l’utilisation principale prévue est de permettre l’accès sécurisé de marchandises et de véhicules accompagnés ou conduits par des personnes, dans des locaux industriels et commerciaux ou des garages dans les zones d’habitation, tel que traité par l’EN 13241.
Vrata, okna, obešene fasade, mreže in polkna - Protivlomna odpornost - Preskusna metoda za ugotavljanje odpornosti proti dinamičnim obremenitvam
General Information
RELATIONS
Standards Content (sample)
SLOVENSKI STANDARD
oSIST prEN 1629:2019
01-julij-2019
Vrata, okna, obešene fasade, mreže in polkna - Protivlomna odpornost -
Preskusna metoda za ugotavljanje odpornosti proti dinamičnim obremenitvam
Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance -
Test method for the determination of resistance under dynamic loadingTüren, Fenster, Vorhangfassaden, Gitterelemente und Abschlüsse - Einbruchhemmung -
Prüfverfahren für die Ermittlung der Widerstandsfähigkeit unter dynamischer Belastung
Blocs-portes pour piétons, fenêtres, façades rideaux, grilles et fermetures - Résistance à
l'effraction - Méthode d'essai pour la détermination de la résistance à la charge
dynamiqueTa slovenski standard je istoveten z: prEN 1629
ICS:
13.310 Varstvo pred kriminalom Protection against crime
91.060.50 Vrata in okna Doors and windows
oSIST prEN 1629:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------oSIST prEN 1629:2019
---------------------- Page: 2 ----------------------
oSIST prEN 1629:2019
DRAFT
EUROPEAN STANDARD
prEN 1629
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2019
ICS 13.310; 91.060.50 Will supersede EN 1629:2011+A1:2015
English Version
Pedestrian doorsets, windows, curtain walling, grilles and
shutters - Burglar resistance - Test method for the
determination of resistance under dynamic loading
Blocs-portes pour piétons, fenêtres, façades rideaux, Türen, Fenster, Vorhangfassaden, Gitterelemente und
grilles et fermetures - Résistance à l'effraction - Abschlüsse - Einbruchhemmung - Prüfverfahren für die
Méthode d'essai pour la détermination de la résistance Ermittlung der Widerstandsfähigkeit unter
à la charge dynamique dynamischer BelastungThis draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 33.If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 1629:2019 E
worldwide for CEN national Members.---------------------- Page: 3 ----------------------
oSIST prEN 1629:2019
prEN 1629:2019 (E)
Contents Page
European foreword ...................................................................................................................................................... 3
1 Scope .................................................................................................................................................................... 4
2 Normative references .................................................................................................................................... 4
3 Terms and definitions ................................................................................................................................... 4
4 Apparatus .......................................................................................................................................................... 5
5 Test specimen................................................................................................................................................... 6
6 Procedure .......................................................................................................................................................... 7
7 Expression of results ..................................................................................................................................... 9
8 Test report ....................................................................................................................................................... 10
Annex A (informative) Test equipment and impact points .......................................................................... 11
A.1 Example of a test rig ..................................................................................................................................... 11
A.2 Load impactor ................................................................................................................................................ 12
A.3 Examples of mounting arrangements for doorsets .......................................................................... 14
A.4 Examples of mounting arrangements for windows.......................................................................... 18
A.5 Examples of mounting arrangements for wing and folding shutters......................................... 20
A.6 Examples of mounting arrangements for guide rails and roller shutters into the test
rig ........................................................................................................................................................................ 23
A.7 Examples of mounting arrangements for grilles into the test rig ............................................... 28
A.8 Impact points for doors .............................................................................................................................. 31
A.9 Impact points for windows ........................................................................................................................ 33
A.10 Impact points for shutters ......................................................................................................................... 34
A.11 Impact points for grilles ............................................................................................................................. 37
Annex B (informative) Test sequence for dynamic loading test in resistance classes 1 to 3 ........... 39
Bibliography.................................................................................................................................................................. 40
---------------------- Page: 4 ----------------------oSIST prEN 1629:2019
prEN 1629:2019 (E)
European foreword
This document (prEN 1629:2019) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This document is currently submitted to the CEN Enquiry.This document will supersede EN 1629:2011+A1:2015.
Significant changes in this revision are:
a) updated editions of Normative references;
b) clarification of combined impact points in 6.2.1.
This document is one of a series of standards for burglar resistant pedestrian doorsets, windows, curtain
walling, grilles and shutters. The other standards in the series are:— prEN 1627:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Requirements and classification;— prEN 1628:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters – Burglar resistance
– Test method for the determination of resistance under static loading;— prEN 1630:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar
resistance — Test method for the determination of resistance to manual burglary attempts.
The test described in this standard is intended to simulate physical attacks, e.g. shoulder charge, kicking.
---------------------- Page: 5 ----------------------oSIST prEN 1629:2019
prEN 1629:2019 (E)
1 Scope
This document specifies a test method for the determination of resistance to dynamic loading in order to
assess the burglar resistant properties of pedestrian doorsets, windows, curtain walling, grilles and
shutters. It is applicable to the following means of opening: turning, tilting, folding, turn-tilting, top or
bottom hung, sliding (horizontally and vertically), pivoted (horizontally and vertically) and rolling as well
as fixed constructions.It is acknowledged that there are two aspects to the burglar resistance performance of construction
products, their normal resistance to forced operation and their ability to remain fixed to the building.
This test method does not evaluate the performance of the fixing to the building.
The manufacturer's installation instructions will give guidance on the fixing of the product.
An example for the contents of the manufacturer's installation instructions is given in Annex A of
prEN 1627:2019.This document does not apply to doors, gates and barriers, intended for installation in areas in the reach
of persons, and for which the main intended uses are giving safe access for goods and vehicles
accompanied or driven by persons in industrial, commercial or residential premises, as covered by
EN 13241.2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated
references, the latest edition of the referenced document (including any amendments) applies.
EN 356:1999, Glass in building - Security glazing - Testing and classification of resistance against manual
attackprEN 1627:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Requirements and classificationprEN 1628:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Test method for the determination of resistance under static loadingprEN 1630:2019, Pedestrian doorsets, windows, curtain walling, grilles and shutters — Burglar resistance
— Test method for the determination of resistance to manual burglary attemptsEN 12600:2002, Glass in building - Pendulum test - Impact test method and classification for flat glass
3 Terms and definitionsFor the purposes of this document, the terms and definitions given in prEN 1627:2019 and the following
apply.ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/• ISO Online browsing platform: available at http://www.iso.org/obp
Under preparation. Stage at the time of publication: prEN 1627:2019.
Under preparation. Stage at the time of publication: prEN 1628:2019.
Under preparation. Stage at the time of publication: prEN 1630:2019.
---------------------- Page: 6 ----------------------
oSIST prEN 1629:2019
prEN 1629:2019 (E)
3.1
test specimen
complete, fully functioning construction product as detailed in the scope of this standard
3.2sub-frame
surrounding frame into which the test specimen is mounted in accordance with the manufacturer’s
instructions3.3
test rig
surrounding substantial steel frame with movable steel supports into which the sub-frames containing
test specimens of various dimensions can be mounted3.4
impacting unit
impactor suspended by means of a suitable steel cable, as a pendulum of fixed length, with a release hook
and height regulating device3.5
impactor
body used to strike the test specimen
3.6
impact point
position on the surface of the test specimen where the dynamic load is applied
4 Apparatus
4.1 Test rig
The test rig consisting of a rigid steel frame with movable steel supports into which test specimens of
various dimensions can be mounted is shown in Annex A, Figure A.1. The stiffness of the rig shall be such
that a 15 kN force applied to any of the defined points and normal to the plane of the frame will not cause
a deflection of more than 5 mm and shall not affect the results of the test. The test rig shall not impede
the execution of the test.4.2 Pendulum impactor
The pendulum impactor, conforming to EN 12600:2002, is listed with individual components and
pictured in Annex A, Figure A.2 and Figure A.3. The impactor shall consist of two pneumatic tyres (type
) inflated to a pressure of 0,35 MPa ± 0,02 MPa with round section and flat longitudinal
3.50 R8 4PRtread and shall be suspended by means of a suitable steel cable giving a minimum pendulum length of
1 000 mm ± 10 mm, with a release hook and height regulating device. The tyres shall be fitted to the rims
(type 250-8) of wheels that carry two steel weights of equal mass. The weights shall be dimensioned so
that the total mass of the impactor is 50 kg ± 0,1 kg (excluding the steel cable and release hook) and the
weights do not have any contact with the test specimen during the impact.Tyre 3.50-R8 4PR can be used for the pendulum test. Tyre 3.50-R8 4PR is the trade name of a product supplied by
Vredestein BV. This information is given for the convenience of users of this European Standard and does not
constitute an endorsement by CEN of the product named. Equivalent products may be used if they can be shown to
lead to the same results.---------------------- Page: 7 ----------------------
oSIST prEN 1629:2019
prEN 1629:2019 (E)
The drop height shall be the vertical height through which the centre of gravity of the impactor falls, with
a tolerance of ± 10 mm. The impactor support point shall allow the impactor to strike the test specimen
at all relevant points. The complete pendulum impactor unit shall be adjustable and may be installed
either on the test rig, as shown in Annex A, Figure A.1, or as an independent unit.
4.3 Suspension systemThe suspension system shall conform to EN 12600:2002.
4.4 Sub-frame
The sub-frame shall simulate the support given to the product when installed into a building and shall be
taken into consideration in the manufacturer´s installation instructions. It shall typically consist of the
following:a) for group 1 to group 4 products a rectangular metal tube 120 mm × 120 mm × 5 mm or a rectangular
timber frame 100 mm × 50 mm;b) additionally, for group 3 products and group 4 products a steel tube 40 mm × 40 mm × 3 mm and a
base plate of 8 mm steel, consisting of several segments which shall be removable for the purposes
of loading, if necessary.4.5 Measuring equipment
The measuring equipment consists of the following:
a) suitable device for measuring the drop height;
b) equipment for determining temperature and relative humidity;
c) gap gauge C, as shown in Figure A.14 of prEN 1628:2019.
The dimensions of the gap gauge shall have a tolerance of ± 1 mm.
5 Test specimen
5.1 General
The test specimen shall be a functioning product complete with its frames, hardware, guide rails, curtain,
tube, roller box and accessories, as appropriate.The test specimen shall be fixed square and plumb and without twist or bend into a sub-frame. The
installation shall be in accordance with the manufacturer's instructions as detailed in Clause 10 of
prEN 1627:2019, including the method of fixing, packing supports, sealing requirements, etc. (see
Annex A, Figures A.4 to A.20 b).NOTE The test can be carried out with the sample mounted in a real wall or building.
For the purposes of this European Standard, the test specimen shall be glazed according to the relevant
glazing resistance class of EN 356:1999, corresponding to the resistance class of the construction product
according to prEN 1627:2019, as shown in Table 1 of this European Standard.For the purpose of this test, the laminated glass shall be placed on the impact side of the product.
---------------------- Page: 8 ----------------------oSIST prEN 1629:2019
prEN 1629:2019 (E)
Table 1 — Test sample glazing requirements
Resistance class Resistance class of glazing according to EN 356:1999
RC 1 N P4 A
RC 2 N P4 A
RC 2 P4 A
RC 3 P5 A
Products that use infilling other than glass shall be tested with the intended infill material. The test
specimen used in the static test in accordance with prEN 1628:2019 may also be used for this test.
Products that are intended to be installed in orientations other than vertical (e.g. roof lights) shall be
installed in the vertical orientation for the purpose of this test.Should the glass break during any tests, the test programme shall proceed with the broken glass in situ.
Adhesive film may be applied to the glass to protect the tester.5.2 Preparation and examination of the test specimen
The temperature of the test specimen shall be maintained between 15 °C and 30 °C for a period of not
less than 8 h prior to test.The test specimen and sub-frame mounted in the test rig shall be visually examined for damage, defects
or other particular conditions of finish, etc. These shall be recorded.During testing, the test s
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.