Gas meters - Thermal-mass flow-meter based gas meter

This European Standard specifies requirements and tests for the construction, performance and safety of class 1,5 Capillary Thermal-Mass Flow sensor gas meters (hereinafter referred to as meter(s)). This applies to meters having co-axial single pipe, or two pipe connections, that are used to measure volumes of fuel gases, which are within the limits of the test gases of the 2nd and/or 3rd family according to EN 437.  
These meters have a maximum working pressures not exceeding 0,5 bar and a maximum flowrate not exceeding 160 m3.h−1 over a minimum ambient temperature range of −10 °C to +40 °C and a gas temperature range as specified by the manufacturer with a minimum range of 40 K.

Gaszähler - Thermische Massendurchflussgaszähler

Dieses Dokument legt Anforderungen und Prüfungen für die Konstruktion, Leistung Sicherheit und Herstellung von batteriebetriebenen thermischen Kapillar-Massendurchflusssensor-Gaszählern der Klasse 1,5 (im Nachfolgenden als Zähler bezeichnet) fest. Es gilt für Zähler mit koaxialen Einstutzen- oder Zweistutzenanschlüssen zur Volumenmessung von Brenngasen aus der Gruppe der Prüfgase der 2. und/oder 3. Familie nach EN 437:2018.
Im Allgemeinen gilt der Begriff "thermische Massendurchflusszähler" für durchflussmessende Geräte, die zur Erfassung und Anzeige des Gasdurchflusses, wie in ISO 14511 festgelegt, Wärmeübertragung nutzen.
ANMERKUNG 1   Obwohl der Begriff "Masse" in der Definition des Messprinzips enthalten ist, messen durch dieses Dokument abgedeckte Gaszähler Gas anhand der Basisbedingungen Temperatur und Druck.
Diese Zähler weisen einen maximalen Betriebsdruck bis 0,5 bar und einen maximalen Durchfluss bis 160 m3 ∙ h−1 über einen Umgebungstemperaturbereich von mindestens −10 °C bis +40 °C auf, sowie einen Gastemperaturbereich, der den Spezifikationen des Herstellers entspricht, jedoch mindestens 40 °C umfasst.
Dieses Dokument gilt für Zähler, die das Volumen bei Basisbedingungen anzeigen und an Standorten mit nicht signifikanten Schwingungs- und Stoßbelastungen installiert sind. Es gilt für Zähler an:
-   geschlossenen Standorten (innen oder außen mit dem vom Hersteller vorgeschriebenen Schutz) mit kondensierender Feuchtigkeit oder nicht kondensierender Feuchtigkeit;
oder, bei entsprechender Angabe durch den Hersteller an:
-   offenen Standorten (außen ohne Abdeckung) mit kondensierender Feuchtigkeit oder nicht kondensierender Feuchtigkeit;
und an Standorten mit elektromagnetischen Störungen, wie sie beim Gebrauch in Wohn- und Gewerbegebäuden sowie Gebäuden der Leichtindustrie auftreten können.
Für Zähler, die nicht umgewertete Volumina anzeigen, kann auf Anhang C verwiesen werden.
Soweit in dieser Norm nicht anders angegeben, sind alle dargestellten Drücke als Überdrücke zu verstehen.
Anforderungen an elektronische Zählwerke, Ventile und zusätzliche Anforderungen für in den Zähler integrierte Batterien und andere Zusatzfunktionen sind in EN 16314:2013 angegeben.
Sofern für einen bestimmten Test nicht anderweitig angegeben, werden die Tests mit Zählern durchgeführt, die vom Hersteller vorgesehene Zusatzfunktionsgeräte besitzen.
Abschnitt 1 bis Abschnitt 13 gelten nur für Bauart und Typprüfung.

Compteurs de gaz - Compteur de gaz thermique de débit massique

Le présent document spécifie les exigences et les essais pour la construction, le fonctionnement et la sécurité des compteurs de gaz à capteur massique thermique capillaire de classe 1.5 (ci-après désigné(s) compteur(s)). Il s'applique aux débitmètres à raccordement monotube coaxial ou bitube, utilisés pour mesurer les volumes de gaz combustibles de la 2e et/ou 3e famille, tels que définis dans l'EN 437:2018.
En général, le terme « débitmètre massique thermique » s'applique aux appareils de mesurage de débit qui mesurent et indiquent le débit de gaz à l'aide du transfert thermique, tels que définis dans l'ISO 14511.
NOTE 1   Bien que le mot « masse » soit présent dans la définition du principe de mesure, les compteurs de gaz couverts par le présent document fournissent un mesurage du gaz dans les conditions de base de température et de pression.
Ces débitmètres ont une pression de service maximale ne dépassant pas 0,5 bar et un débit maximal ne dépassant pas 160 m3⋅h−1 dans une plage de température ambiante minimale comprise entre −10 °C et +40 °C et une plage de température du gaz telle que spécifiée par le fabricant avec une plage minimale de 40°C.
Le présent document s'applique aux débitmètres indiquant le volume dans les conditions de base, installés dans des lieux exposés à des vibrations et des chocs peu importants. Il s'applique aux débitmètres dans :
-   les lieux fermés (intérieurs ou extérieurs avec protection, tel que spécifié par le fabricant) avec humidité de condensation ou une humidité sans condensation ;
ou, si spécifié par le fabricant :
-   les lieux ouverts (extérieurs sans couvercle) avec humidité de condensation ou avec humidité sans condensation ;
et dans les lieux avec des perturbations électromagnétiques susceptibles d'être présentes dans les utilisations résidentielles, commerciales et celle de l'industrie légère.
Pour les débitmètres qui indiquent un volume non converti, on peut se référer à l'Annexe C.
Sauf spécification contraire, toutes les pressions données par le présent document sont des pressions effectives.
Les exigences pour les index électroniques, les vannes et les exigences supplémentaires pour les batteries incorporées dans le débitmètre et toute autre fonctionnalité supplémentaire sont données dans l'EN 16314:2013.
Sauf spécification contraire dans un essai particulier, les essais sont réalisés sur des débitmètres comprenant des appareils à fonctionnalités supplémentaires prévues par le fabricant.
Les Articles 1 à 13 concernent uniquement les essais de conception et de type.

Plinomeri - Plinomer na osnovi termičnega merjenja masnega toka

General Information

Status
Not Published
Public Enquiry End Date
02-Jun-2020
Technical Committee
Current Stage
5020 - Formal vote (FV) (Adopted Project)
Start Date
22-Apr-2021
Due Date
10-Jun-2021
Completion Date
07-May-2021

Buy Standard

Draft
oSIST prEN 17526:2020
English language
88 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
oSIST prEN 17526:2020
01-maj-2020
Plinomeri - Plinomer na osnovi termičnega merjenja masnega toka
Gas meters - Thermal-mass flow-meter based gas meter
Gaszähler - Thermische Massendurchflussgaszähler
Ta slovenski standard je istoveten z: prEN 17526
ICS:
91.140.40 Sistemi za oskrbo s plinom Gas supply systems
oSIST prEN 17526:2020 en,fr,de

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 17526:2020
---------------------- Page: 2 ----------------------
oSIST prEN 17526:2020
DRAFT
EUROPEAN STANDARD
prEN 17526
NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2020
ICS 91.140.40
English Version
Gas meters - Thermal-mass flow-meter based gas meter
Gaszähler - Thermische Massendurchflussgaszähler

This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee

CEN/TC 237.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations

which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC

Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,

Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,

Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and

United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are

aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without

notice and shall not be referred to as a European Standard.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels

© 2020 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 17526:2020 E

worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
oSIST prEN 17526:2020
prEN 17526:2020 (E)
Contents Page

European foreword ....................................................................................................................................................... 7

1 Scope .................................................................................................................................................................... 8

2 Normative references .................................................................................................................................... 8

3 Terms, definitions and symbols .............................................................................................................. 10

3.1 Terms and definitions ................................................................................................................................ 11

3.2 Symbols ............................................................................................................................................................ 15

4 Working conditions ..................................................................................................................................... 17

4.1 General ............................................................................................................................................................. 17

4.2 Base conditions ............................................................................................................................................. 17

4.3 Flow range ...................................................................................................................................................... 17

4.4 Maximum working pressure .................................................................................................................... 18

4.5 Temperature range ..................................................................................................................................... 18

4.5.1 General ............................................................................................................................................................. 18

4.5.2 Ambient temperature range .................................................................................................................... 18

4.5.3 Gas temperature range .............................................................................................................................. 18

4.5.4 Storage temperature range ...................................................................................................................... 19

4.6 Range of gases ............................................................................................................................................... 19

4.7 Installation orientation .............................................................................................................................. 19

5 Metrological performance ........................................................................................................................ 19

5.1 General ............................................................................................................................................................. 19

5.2 Test mode comparison ............................................................................................................................... 20

5.2.1 General ............................................................................................................................................................. 20

5.2.2 Requirements ................................................................................................................................................ 20

5.2.3 Test .................................................................................................................................................................... 20

5.2.4 Test mode in flow (optional) .................................................................................................................... 20

5.3 Permissible errors ....................................................................................................................................... 21

5.3.1 Requirements ................................................................................................................................................ 21

5.3.2 Test .................................................................................................................................................................... 22

5.4 Gas-air relationship ..................................................................................................................................... 23

5.4.1 General ............................................................................................................................................................. 23

5.4.2 Requirements ................................................................................................................................................ 23

5.4.3 Test .................................................................................................................................................................... 23

5.5 Pressure absorption .................................................................................................................................... 24

5.5.1 Requirements ................................................................................................................................................ 24

5.5.2 Test .................................................................................................................................................................... 24

5.6 Metrological stability .................................................................................................................................. 25

5.7 Immunity to contaminants in gas stream (dust test) ...................................................................... 25

5.7.1 Requirements ................................................................................................................................................ 25

5.7.2 Specification of contamination dust to be used in test 5.7.3 ........................................................ 27

5.7.3 Test .................................................................................................................................................................... 27

5.8 Flow disturbances ........................................................................................................................................ 29

5.8.1 Requirements ................................................................................................................................................ 29

5.8.2 Test .................................................................................................................................................................... 29

5.9 Zero flow .......................................................................................................................................................... 33

5.9.1 Requirements ................................................................................................................................................ 33

5.9.2 Test .................................................................................................................................................................... 33

---------------------- Page: 4 ----------------------
oSIST prEN 17526:2020
prEN 17526:2020 (E)

5.10 Reverse flow ................................................................................................................................................... 34

5.10.1 Requirements ................................................................................................................................................. 34

5.10.2 Test .................................................................................................................................................................... 34

5.11 Low flow registration (starting flow rate) ........................................................................................... 34

5.11.1 Requirements ................................................................................................................................................. 34

5.11.2 Test .................................................................................................................................................................... 34

5.12 Overload flow rate ........................................................................................................................................ 34

5.12.1 Requirements ................................................................................................................................................. 34

5.12.2 Test .................................................................................................................................................................... 34

5.13 Pulsed (unsteady) flow ............................................................................................................................... 35

5.13.1 General ............................................................................................................................................................. 35

5.13.2 Requirements ................................................................................................................................................. 35

5.13.3 Test .................................................................................................................................................................... 35

6 Construction and materials ...................................................................................................................... 35

6.1 Mechanical interference ............................................................................................................................ 35

6.1.1 Requirements ................................................................................................................................................. 35

6.1.2 Test .................................................................................................................................................................... 36

6.2 Unauthorized interference ........................................................................................................................ 36

6.2.1 Requirements ................................................................................................................................................. 36

6.2.2 Test .................................................................................................................................................................... 36

6.3 Robustness of meter case .......................................................................................................................... 36

6.3.1 Meter case........................................................................................................................................................ 36

6.3.2 Protection against penetration of dust and water ............................................................................ 36

6.3.3 External leak tightness ............................................................................................................................... 37

6.3.4 Resistance to internal pressure............................................................................................................... 37

6.3.5 Heat resistance .............................................................................................................................................. 38

6.3.6 Resistance to impact .................................................................................................................................... 38

6.3.7 Resistance to mishandling ......................................................................................................................... 41

6.4 Connections .................................................................................................................................................... 41

6.4.1 Orientation ...................................................................................................................................................... 41

6.4.2 Threads and flanges for single and two pipe meters ....................................................................... 42

6.4.3 Strength ............................................................................................................................................................ 45

6.5 Resistance to vibration ............................................................................................................................... 46

6.5.1 Requirements ................................................................................................................................................. 46

6.5.2 Apparatus ........................................................................................................................................................ 46

6.5.3 Test .................................................................................................................................................................... 47

6.6 Corrosion protection ................................................................................................................................... 48

6.6.1 General ............................................................................................................................................................. 48

6.6.2 External corrosion ........................................................................................................................................ 48

6.7 Flame retardance of external surfaces ................................................................................................. 49

6.7.1 Requirements ................................................................................................................................................. 49

6.7.2 Test .................................................................................................................................................................... 49

6.8 Requirements for rubber components in the gas path ................................................................... 50

6.8.1 Requirements ................................................................................................................................................. 50

6.8.2 Test .................................................................................................................................................................... 50

6.9 Resistance to storage temperature range ........................................................................................... 50

6.9.1 Requirements ................................................................................................................................................. 50

6.9.2 Test .................................................................................................................................................................... 50

6.10 Resistance to toluene/iso-octane vapour ............................................................................................ 50

6.10.1 Requirements ................................................................................................................................................. 50

6.10.2 Test .................................................................................................................................................................... 50

6.11 Resistance to water vapour ....................................................................................................................... 52

---------------------- Page: 5 ----------------------
oSIST prEN 17526:2020
prEN 17526:2020 (E)

6.11.1 Requirements ................................................................................................................................................ 52

6.11.2 Test .................................................................................................................................................................... 52

6.11.3 Example of a typical apparatus ............................................................................................................... 52

6.12 Ageing ............................................................................................................................................................... 53

6.12.1 Requirements ................................................................................................................................................ 53

6.12.2 Test .................................................................................................................................................................... 53

7 Optional features .......................................................................................................................................... 54

7.1 Pressure measuring point ......................................................................................................................... 54

7.1.1 Requirements ................................................................................................................................................ 54

7.1.2 Test .................................................................................................................................................................... 54

7.2 Electrical insulating feet (optional) ....................................................................................................... 55

7.2.1 Requirements ................................................................................................................................................ 55

7.2.2 Test .................................................................................................................................................................... 55

7.3 Resistance to high ambient temperatures .......................................................................................... 55

7.3.1 Requirements ................................................................................................................................................ 55

7.3.2 Test .................................................................................................................................................................... 56

7.3.3 Example of a typical resistance to high ambient temperature test apparatus ...................... 56

7.4 Additional functionalities (if fitted) ...................................................................................................... 57

7.4.1 Requirements ................................................................................................................................................ 57

7.4.2 Test .................................................................................................................................................................... 57

7.5 Use in hazardous zones .............................................................................................................................. 58

7.5.1 Requirement .................................................................................................................................................. 58

7.5.2 Test .................................................................................................................................................................... 58

8 Index ................................................................................................................................................................. 58

8.1 Recording and storage ............................................................................................................................... 58

8.1.1 Requirement .................................................................................................................................................. 58

8.1.2 Test .................................................................................................................................................................... 58

8.2 Display .............................................................................................................................................................. 58

8.2.1 Requirements ................................................................................................................................................ 58

8.2.2 Test .................................................................................................................................................................... 59

8.3 Display functionality ................................................................................................................................... 59

8.3.1 Requirements ................................................................................................................................................ 59

8.3.2 Test .................................................................................................................................................................... 59

8.4 Non-volatile memory .................................................................................................................................. 60

8.4.1 Requirements ................................................................................................................................................ 60

8.4.2 Test .................................................................................................................................................................... 60

9 Marking ............................................................................................................................................................ 61

9.1 All meters ........................................................................................................................................................ 61

9.2 Two-pipe meters .......................................................................................................................................... 61

9.2.1 Requirements ................................................................................................................................................ 61

9.2.2 Test .................................................................................................................................................................... 61

9.3 Durability and legibility of marking and labels ................................................................................ 62

9.3.1 Requirements ................................................................................................................................................ 62

9.3.2 Tests .................................................................................................................................................................. 62

9.4 Indelibility of marking ............................................................................................................................... 63

9.4.1 Requirement .................................................................................................................................................. 63

9.4.2 Tests .................................................................................................................................................................. 63

10 Software ........................................................................................................................................................... 63

10.1 Requirements ................................................................................................................................................ 63

10.2 Test .................................................................................................................................................................... 63

11 Communications ........................................................................................................................................... 64

---------------------- Page: 6 ----------------------
oSIST prEN 17526:2020
prEN 17526:2020 (E)

11.1 General ............................................................................................................................................................. 64

11.1.1 Requirements ................................................................................................................................................. 64

11.1.2 Test .................................................................................................................................................................... 64

11.2 Metrological influence of radio communication function ............................................................. 64

11.2.1 Requirements ................................................................................................................................................. 64

11.2.2 Test .................................................................................................................................................................... 64

11.3 Test mode ........................................................................................................................................................ 65

11.3.1 Requirements ................................................................................................................................................. 65

11.3.2 Test .................................................................................................................................................................... 65

11.4 Data optical port (optional) ...................................................................................................................... 65

11.5 Galvanic port (optional) ............................................................................................................................. 65

11.6 Diagnostics ...................................................................................................................................................... 65

11.6.1 Requirements ....................................................................................................................................

...

Questions, Comments and Discussion