23.060.20 - Ball and plug valves
ICS 23.060.20 Details
Ball and plug valves
Ventile
Robinets a tournant (sphérique, cylindrique ou conique)
Zapirni ventili (kroglasti in pipe)
General Information
e-Library Subscription
Create subscription and get permanent access to documents within 23.060.20 - Ball and plug valves
Currently subscription includes documents marked with .We are working on making all documents available within the subscription.
This document provides basic requirements for piston type pneumatic linear actuators for industrial valve, both double acting and single acting, used for on-off and modulating control duties.
It includes criteria, method and guidelines for design, qualification, corrosion protection, control and testing.
It does not apply to diaphragm actuators and to pneumatic actuators which are integral parts of control valves.
Other requirements, or conditions of use, different from those indicated in this document, are subject to agreement, between the purchaser and the manufacturer/supplier, prior to order.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides basic requirements for pneumatic part-turn valve actuators, both double acting and
single acting, used for on-off and modulating control duties. It includes guidelines, recommendations and
methods for enclosure and corrosion protection, control and testing.
It does not apply to pneumatic actuators which are integral parts of control valves.
Other requirements, or conditions of use, different from those indicated in this document, shall be subject to
negotiations, between the purchaser and the manufacturer/supplier, prior to order.
The terms and definitions applicable to this European Standard are given in FprEN 15714-1.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides basic requirements for piston type hydraulic linear actuators for industrial valve, both double acting and single acting, used for on-off and modulating control duties.
It includes criteria, method and guidelines for design, qualification, corrosion protection, control and testing.
It does not apply to hydraulic actuators which are integral parts of control valves.
Other requirements, or conditions of use, different from those indicated in this document, should be subject to negotiations, between the purchaser and the Manufacturer/supplier, prior to order.
The terms and definitions given in EN 15714-1 are used in this European Standard as applicable.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies basic requirements for pneumatic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties.
It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing.
It does not apply to pneumatic actuators which are integral parts of control valves and to pneumatic actuators designed for permanent immersion in fresh or sea water.
Other requirements, or conditions of use, different from those indicated in this document, are expected to be subject to negotiations, between the purchaser and the manufacturer/supplier, prior to order.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies basic requirements for piston type hydraulic linear actuators for industrial valve, both double acting and single acting, used for on-off and modulating control duties. It includes criteria, method and guidelines for design, qualification, corrosion protection, control and testing.
It does not apply to hydraulic actuators which are integral parts of control valves. Other requirements, or conditions of use, different from those indicated in this document, are expected to be subject to negotiations, between the purchaser and the manufacturer/supplier, prior to order.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides basic requirements for piston type pneumatic linear actuators for industrial valve, both double acting and single acting, used for on-off and modulating control duties.
It includes criteria, method and guidelines for design, qualification, corrosion protection, control and testing.
It does not apply to diaphragm actuators and to pneumatic actuators which are integral parts of control valves.
Other requirements, or conditions of use, different from those indicated in this document, are subject to negotiations, between the purchaser and the manufacturer/supplier, prior to order.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies design, type testing, marking and manufacturing test and examination
requirements for ball valves used as:
a) closures of refillable transportable gas cylinders, pressure drums and tubes;
b) main valves for cylinder bundles;
c) valves for cargo transport units (e.g. trailers, battery vehicles and MEGCs);
which convey compressed gases, liquefied gases and dissolved gases.
NOTE 1 In the course of the document, the term "valve" is used with the meaning of "ball valve".
This document does not apply to:
• oxidizing gases as defined in ISO 10156,
• toxic gases (i.e. gases listed in ISO 10298 having an LC50 value ≤ 5 000 ppm) and
• acetylene for single gas cylinders, pressure drums and tubes.
NOTE 2 The reason for the exclusion of oxidizing gases is that the use of ball valves as closures of high
pressure cylinders for oxidizing gases is known to lead to specific ignition hazards that cannot reasonably be mitigated through the ball valve design or type testing. Safety hazards concern both the ball valve itself and any downstream equipment.
This International document does not apply to ball valves for liquefied petroleum gas (LPG),
cryogenic equipment, portable fire extinguishers and cylinders for breathing apparatus.
NOTE 3 Requirements for valves for cryogenic vessels are specified in ISO 21011 and at a regional level, e.g. in EN 1626. Requirements for valves for portable fire extinguishers at a regional level are specified e.g. in EN 3 series.
NOTE 4 Certain specific requirements for valves for breathing apparatus in addition to those that are
given in this document are specified at a regional level, e.g. in EN 144 series. Certain specific requirements for quick-release valves for fixed fire-fighting systems in addition to those that are given in this document are specified in ISO 16003 and at a regional level e.g. in EN 12094–4.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies safety requirements, safety factors, test methods, test pressures used and marking of refrigerating valves and other components with similar bodies, hereinafter called valves, for use in refrigerating systems.
It describes the procedure to be followed when designing (by calculation or by an experimental design method) valve parts subjected to pressure as well as the criteria to be used in the selection of materials.
The standard describes methods by which reduced impact values at low temperatures may be taken into account in a safe manner.
This standard applies to the design of bodies and bonnets for pressure relief devices, including bursting disc devices, with respect to pressure containment but it does not apply to any other aspects of the design or application of pressure relief devices.
- Standard100 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
- Amendment13 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesEnglish languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
- Standard6 pagesFrench languagesale 15% off
1.1 This European Standard specifies the characteristics for the construction, performance and safety of ball valves and closed bottom taper plug valves. It also details the test methods and marking provisions.
It applies to metallic valves not directly buried for domestic and commercial installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437) and working up to 0,2 × 105 Pa, 0,5 × 105 Pa, 1 × 105Pa, 5 × 105 Pa and 20 × 105Pa and with temperature limits from -5 °C or −20 °C to + 60 °C.
NOTE "Not directly buried" within the context of this standard means that valves below ground are not in direct contact with earth or other materials e.g. that they are in a protected encasement.
1.2 Valve nominal sizes (DN) covered by this European Standard are as follows: 6, 8, 10, 12, 15, 20, 25, 32, 40, 50, 65, 80, 100.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 17292:2015 specifies the requirements for a series of metal ball valves suitable for petroleum, petrochemical, natural gas plants, and related industrial applications.
It covers valves of the nominal sizes DN:
- 8, 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600;
corresponding to nominal pipe sizes NPS:
- ¼, ⅜, ½, , 1, 1 ¼, 1 ½, 2, 2 ½, 3, 4, 6, 8, 10, 12, 14, 16, 18, 20, 24;
and applies for pressure designations:
- Class 150; 300; 600; 800 (Class 800 applies only for valves with threaded and socket welding end);
- PN 16, 25, 40, 63, 100.
It includes provisions for testing and inspection and for valve characteristics as follows:
- flanged and butt-welded ends, in sizes 15 ≤ DN ≤ 600 (½ ≤ NPS ≤ 24);
- socket welding and threaded ends, in sizes 8 ≤ DN ≤ 50 (¼ ≤ NPS ≤ 2);
- body seat openings designated as full bore, reduced bore, and double reduced bore;
- materials.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 7121:2016 specifies the requirements for a series of steel ball valves suitable for general-purpose industrial applications. It covers valves of the nominal sizes - DN 8, 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, and 600 (NPS 1/4, 3/8, 1/2, 3/4, 1, 11/4, 11/2, 2, 21/2, 3, 4, 6, 8, 10, 12, 14, 16, 18, 20 and 24), and is applicable to the following pressure designations: - PN 10; 16; 25; 40; 63; 100; - Class 150; 300; 600; 800; 900. NOTE Valve characteristics are not necessarily available in all nominal sizes for all pressure designations. For example, Class 800 applies only for valves with threaded end and socket weld ends up to DN 65 (NPS 21/2) and Class 900 applies only for reduced bore body seat openings. It includes provisions for valve characteristics as follows: - flanged and butt-welded ends in sizes 15 ≤ DN ≤ 600 (1/2 ≤ NPS ≤ 24); - socket welding ends in sizes 8 ≤ DN ≤ 100 (1/4 ≤ NPS ≤ 4); - threaded ends in sizes 8 ≤ DN ≤ 50 (1/4 ≤ NPS ≤ 2); - body seat openings designated as full bore, reduced bore and double reduced bore; - materials; - testing and inspection.
- Standard22 pagesEnglish languagesale 15% off
1.1 This European standard specifies the general requirements for the construction, performance and safety of ball valves and closed bottom taper plug valves. It also details the test methods and marking requirements.
It applies to metallic valves for domestic and commercial not directly buried installations inside or outside of buildings, using gases of the first, second and third family (specified in EN 437) and working up to
0,2 105 Pa, 0,5 105 Pa, 1 x 105Pa. 5 105 Pa and 20 x 105Pa.
NOTE "Not directly buried" within the context of this standard means that valves below ground are not in direct contact with earth or other materials e.g. that they are in a protected encasement.
1.2 Valve nominal sizes (DN) covered by this European standard are as follows: 6, 8, 10, 12, 15, 20, 25, 32, 40, 50.
- Standard45 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 17292:2004 specifies the requirements for a series of metal ball valves suitable for petroleum, petrochemical, natural gas plants, and related industrial applications. It covers valves of the nominal sizes DN 8, 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450 and 500, corresponding to nominal pipe sizes NPS 1/4, 3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 4, 6, 8, 10, 12, 14, 16, 18 and 20, and is applicable for pressure designations of Class 150, 300, 600 and 800 (the last applicable only for valves with reduced bore and with threaded and socket welding end), and PN 16, 25 and 40.
- Standard35 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 17292:2015 specifies the requirements for a series of metal ball valves suitable for petroleum, petrochemical, natural gas plants, and related industrial applications. It covers valves of the nominal sizes DN: - 8, 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600; corresponding to nominal pipe sizes NPS: - ¼, ⅜, ½, , 1, 1 ¼, 1 ½, 2, 2 ½, 3, 4, 6, 8, 10, 12, 14, 16, 18, 20, 24; and applies for pressure designations: - Class 150; 300; 600; 800 (Class 800 applies only for valves with threaded and socket welding end); - PN 16, 25, 40, 63, 100. It includes provisions for testing and inspection and for valve characteristics as follows: - flanged and butt-welded ends, in sizes 15 ≤ DN ≤ 600 (½ ≤ NPS ≤ 24); - socket welding and threaded ends, in sizes 8 ≤ DN ≤ 50 (¼ ≤ NPS ≤ 2); - body seat openings designated as full bore, reduced bore, and double reduced bore; - materials.
- Standard25 pagesEnglish languagesale 15% off
- Standard25 pagesEnglish languagesale 15% off
- Standard27 pagesFrench languagesale 15% off
- Standard27 pagesFrench languagesale 15% off
This European Standard applies to copper alloy ball valves for general use having, flanged, threaded, capillary or compression or loose nut/union body ends.
This European Standard does not apply to copper alloy ball valves for drinking water applications.
This European Standard specifies the design and performance requirements including materials, pressure/temperature ratings for the shell and body seats, dimensions, test procedures and marking.
For some specific fields of application, for example gas, valves to this European Standard can be used provided the requirements of the relevant performance standards are met. Approval by the relevant regulatory body may be required.
The range of nominal sizes is DN 6 to DN 300 and of nominal diameters 6 mm to 110 mm.
The range of pressure designations covered is PN 6 ; PN 10 ; PN 16 ; PN 20 ; PN 25 ; PN 32 ; PN 40 ; PN 63 ; Class 150 and Class 300.
For the applicability of each nominal size/diameter and each pressure designation to the different types of valve end, see 4.1.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for industrial steel ball valves having flanged, threaded, socket welding or butt welding ends.
The DN range is:
- DN 4 ; DN 6 ; DN 8 ; DN 10 ; DN 15 ; DN 20 ; DN 25 ; DN 32 ; DN 40 ; DN 50 ; DN 65 ; DN 80 ; DN 100 ; DN 125 ; DN 150 ; DN 200 ; DN 250 ; DN 300 ; DN 350 ; DN 400 ; DN 450 ; DN 500 ; DN 550 ; DN 600 ; DN 650 ; DN 700 ; DN 750 ; DN 800 ; DN 850 ; DN 900.
The PN and Class ranges are:
- PN 6 ; PN 10 ; PN 16 ; PN 25 ; PN 40 ; PN 63 ; PN 100 ;
- Class 150 ; Class 300 ; Class 600 ; Class 900 ; Class 1 500 ; Class 2 500 ; Class 4 500.
This European Standard applies to steel ball valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standard are met.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements for industrial steel ball valves having flanged, threaded, socket welding or butt welding ends. The DN range is:
- DN 4 ; DN 6 ; DN 8 ; DN 10 ; DN 15 ; DN 20 ; DN 25 ; DN 32 ; DN 40 ; DN 50 ; DN 65 ; DN 80 ; DN 100 ; DN 125 ; DN 150 ; DN 200 ; DN 250 ; DN 300 ; DN 350 ; DN 400 ; DN 450 ; DN 500 ; DN 550 ; DN 600 ; DN 650 ; DN 700 ; DN 750 ; DN 800 ; DN 850 ; DN 900.
The PN and Class ranges are:
- PN 6 ; PN 10 ; PN 16 ; PN 25 ; PN 40 ; PN 63 ; PN 100 ;
- Class 150 ; Class 300 ; Class 600 ; Class 900 ; Class 1 500 ; Class 2 500 ; Class 4 500.
This European Standard applies to steel ball valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standard are met.
- Standard17 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to copper alloy ball valves for general use having, flanged, threaded, capillary or compression or loose nut/union body ends. This European Standard does not apply to copper alloy ball valves for drinking water applications. This European Standard specifies the design and performance requirements including materials, pressure/temperature ratings for the shell and body seats, dimensions, test procedures and marking. For some specific fields of application, for example gas, valves to this European Standard can be used provided the requirements of the relevant performance standards are met. Approval by the relevant regulatory body may be required. The range of nominal sizes is DN 6 to DN 300 and of nominal diameters 6 mm to 110 mm The range of pressure designations covered is PN 6 ; PN 10 ; PN 16 ; PN 20 ; PN 25 ; PN 32 ; PN 40 ; PN 63 ; Class 150 and Class 300. For the applicability of each nominal size/diameter and each pressure designation to the different types of valve end.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the vapour transfer valve, used for the transfer of vapour between the tank compartment and the pipework connecting to the vapour collection adaptor.
This European Standard specifies the performance requirements and the critical dimensions of the vapour transfer valve. It also specifies the tests necessary to verify the compliance of the equipment with this European Standard. The equipment specified by this standard is suitable for use with liquid petroleum products and other dangerous substances of Class 3 of ADR [2] which have a vapour pressure not exceeding 110 kPa at 50 °C and petrol, and which have no sub-classification as toxic or corrosive.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the vapour transfer valve, used for the transfer of vapour between the tank compartment and the pipework connecting to the vapour collection adaptor.
This European Standard specifies the performance requirements and the critical dimensions of the vapour transfer valve. It also specifies the tests necessary to verify the compliance of the equipment with this European Standard. The equipment specified by this standard is suitable for use with liquid petroleum products and other dangerous substances of Class 3 of ADR [2] which have a vapour pressure not exceeding 110 kPa at 50 °C and petrol, and which have no sub-classification as toxic or corrosive.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides basic requirements for hydraulic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties. It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing. It does not apply, to hydraulic actuators that are integral parts of control valves or to electro-hydraulic actuators. Other requirements or conditions of use different from those indicated in this document should be subject to negotiations between the purchaser and the manufacturer/supplier prior to order. The terms and definitions applicable to this European Standard are given in EN 15714-1.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines specific terms and definitions used for industrial valve actuators not included in EN 736-2 and EN 736-3.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for steel globe and globe stop and check valves which are wrought, cast or fabricated in straight, angle or oblique pattern with end connections flanged, butt welding, socket welding or threaded.
This standard is applicable to steel globe and globe stop and check valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standards are met.
The range of nominal sizes covered is:
DN 8; DN 10; DN 12; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400.
DN 8 and DN 12 are not used for PN designated flanged end connections.
DN 8, DN 10 and DN 12 are not used for Class designated flanged end connections.
Socket welding end valves and threaded end valves are limited to the range DN 8 to DN 65.
The range of pressure designations covered is:
a) for flanged and butt welding end valves:
- PN 10; PN 16; PN 25; PN 40; PN 63; PN 100;
- Class 150; Class 300; Class 600.
b) for socket welding end valves and threaded end valves:
- PN 40; PN 63; PN 100;
- Class 600; Class 800.
NOTE Class 800 is a Class designation widely used for socket welding and threaded end valves.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies the requirements for cast iron globe valves in straight, angle or oblique pattern (see EN 736 2) with flanged or threaded end connections.
This European Standard is applicable to cast iron globe valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standards are met.
The range of nominal sizes covered is:
a) flanged:
DN 10; DN 15; DN 20; DN 25; DN 32; DN 40; DN 50; DN 65; DN 80; DN 100; DN 125; DN 150; DN 200; DN 250; DN 300; DN 350; DN 400.
b) threaded:
½, ¾, 1, 1¼, 1½, 2.
The range of pressure designations covered is:
a) for flanged end valves:
PN 6; PN 10; PN 16; PN 25; PN 40;
b) for threaded end valves:
PN 6; PN 10; PN 16.
- Standard14 pagesEnglish languagesale 10% offe-Library read for1 day
This document defines specific terms and definitions used for industrial valve actuators not included in EN 736-2 and EN 736-3.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This document provides basic requirements for hydraulic part-turn valve actuators, both double acting and
single acting, used for on-off and modulating control duties. It includes guidelines, recommendations and
methods for enclosure and corrosion protection, control and testing.
It does not apply, to hydraulic actuators that are integral parts of control valves or to electro-hydraulic
actuators.
Other requirements or conditions of use different from those indicated in this document shall be subject to
negotiations between the purchaser and the manufacturer/supplier prior to order.
The terms and definitions applicable to this European Standard are given in FprEN 15714-1.
- Standard25 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies requirements and tests for ball valves of thermoplastics materials for isolating service, for control service, and to divert/mix fluids.
This standard is applicable to hand or power operated valves to be installed in industrial pipe systems, irrespective of the field of application and the fluids to be conveyed. For other and/or special applications special requirements may apply.
The range of DN is :
- DN 8, DN 10, DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125 und DN 150.
The range of PN and Class is :
- PN 6, PN 10, PN 16, PN 25, Class 150 und Class 300.
The requirements specified by this standard concern the design, functional characteristics and manufacture of ball valves, their connection to the pipe system, the body materials and their pressure/temperature rating between - 40 °C up to + 120 °C, for a lifetime of 25 years.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16135:2006 specifies requirements for the design, functional characteristics and manufacture of ball valves made of thermoplastics materials intended for isolating service, for control service, and to divert/mix fluids, their connection to the pipe system, the body materials and their pressure/temperature rating between -40 degrees Celsius and + 120 degrees Celsius, for a lifetime of 25 years, and also specifies their tests.
ISO 16135:2006 is applicable to hand- or power-operated valves to be installed in industrial pipe systems, irrespective of the field of application and the fluids to be conveyed.
It is concerned with the ranges DN 8, DN 10, DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125 and DN 150, and the ranges PN 6, PN 10, PN 16 and PN 25, and Class 150 and Class 300.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 16135:2006 specifies requirements for the design, functional characteristics and manufacture of ball valves made of thermoplastics materials intended for isolating service, for control service, and to divert/mix fluids, their connection to the pipe system, the body materials and their pressure/temperature rating between -40 degrees Celsius and + 120 degrees Celsius, for a lifetime of 25 years, and also specifies their tests. ISO 16135:2006 is applicable to hand- or power-operated valves to be installed in industrial pipe systems, irrespective of the field of application and the fluids to be conveyed. It is concerned with the ranges DN 8, DN 10, DN 15, DN 20, DN 25, DN 32, DN 40, DN 50, DN 65, DN 80, DN 100, DN 125 and DN 150, and the ranges PN 6, PN 10, PN 16 and PN 25, and Class 150 and Class 300.
- Standard20 pagesEnglish languagesale 15% off
- Standard20 pagesFrench languagesale 15% off
This European standard applies primarily to copper alloy ball valves, dimensions DN 8 to DN 100, for potable water supply in buildings up to PN 10 and a distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum.
This standard applies also to ball valves in combination with other components in the same body.
This standard specifies:
- the requirements of the materials and the design of ball valves;
- the mechanical, hydraulic and acoustic requirements of ball valves;
- the test methods to verify the requirements of ball valves;
- the marking requirements of ball valves.
Ball valves in combination with other valves should fulfil the same requirements.
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the non pressure balanced footvalve for bottom loading and unloading and specifies the performance requirements, dimensions and tests necessary to verify the compliance of the equipment to this standard.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the pressure balanced footvalve for bottom loading and unloading and specifies the performance requirements, dimensions and tests necessary to verify the compliance of the equipment to this standard.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the non pressure balanced footvalve for bottom loading and unloading and specifies the performance requirements, dimensions and tests necessary to verify the compliance of the equipment to this standard.
- Standard15 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the pressure balanced footvalve for bottom loading and unloading and specifies the performance requirements, dimensions and tests necessary to verify the compliance of the equipment to this standard.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
The purpose of this Standard EN 1213 is to specify: - the requirements for the materials and the design of stopvalves; - the mechanical, hydraulic and acousticrequirements ; - the test methods; - the marking requirements; for copper alloy stopvalves for use with drinking water supply in buildings. This standard applies primarily to copper alloy stopvalves, dimensions DN 10 to DN 100, for potable water supply in buildings up to PN 10 and a distribution temperature of 65°C. Occasional excursions up to 95°C are permitted for a period of 1 hr. maximum.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
The purpose of this Standard EN 1213 is to specify: - the requirements for the materials and the design of stopvalves; - the mechanical, hydraulic and acousticrequirements ; - the test methods; - the marking requirements; for copper alloy stopvalves for use with drinking water supply in buildings. This standard applies primarily to copper alloy stopvalves, dimensions DN 10 to DN 100, for potable water supply in buildings up to PN 10 and a distribution temperature of 65°C. Occasional excursions up to 95°C are permitted for a period of 1 hr. maximum.
- Standard18 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies basic requirements for hydraulic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties.
It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing.
It does not apply to hydraulic actuators which are integral parts of control valves and to hydraulic actuators designed for permanent immersion in fresh or sea water as well as electro-hydraulic actuators.
Other requirements, or conditions of use, different from those indicated in this document can vary upon request.
- Draft31 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to 2-way or multi-way ball valve manufactured with thermoplastic materials to be used for the transport of pressurized water whether or not intended for human consumption (domestic systems) for applications in buildings and utility branches.
NOTE The two-way valve is generally used for sectioning and control, the multi-way one to divert or mix the flows; information on their functionality can be
found in Appendix B information of ISO 16135.
The application classes are indicated in the relevant hot and cold water system standards.
This document defines the dimensions necessary for the assembly of the valves, ensuring its
interchangeability and defines its physical and mechanical requirements.
- Draft23 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies primarily to copper alloy and stainless steel ball valves with dimensions DN 6 to DN 100, for installations in buildings for potable water supply up to PN16 and a maximum distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum.
The ball valves are classified by their nominal pressure being either PN10 or PN16.
This document specifies:
- the requirements of the materials and the design of ball valves;
- the mechanical, hydraulic and acoustic requirements of ball valves;
- the test methods to verify the requirements of ball valves;
- the marking requirements of ball valves.
- Draft28 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies basic requirements for hydraulic part-turn valve actuators, both double acting and single acting, used for on-off and modulating control duties.
It includes guidelines, recommendations and methods for enclosure and corrosion protection, control and testing.
It does not apply to hydraulic actuators which are integral parts of control valves and to hydraulic actuators designed for permanent immersion in fresh or sea water as well as electro-hydraulic actuators.
Other requirements, or conditions of use, different from those indicated in this document can vary upon request.
- Draft31 pagesEnglish languagesale 10% offe-Library read for1 day
This document is applicable to 2-way or multi-way ball valve manufactured with thermoplastic materials to be used for the transport of pressurized water whether or not intended for human consumption (domestic systems) for applications in buildings and utility branches.
NOTE The two-way valve is generally used for sectioning and control, the multi-way one to divert or mix the flows; information on their functionality can be
found in Appendix B information of ISO 16135.
The application classes are indicated in the relevant hot and cold water system standards.
This document defines the dimensions necessary for the assembly of the valves, ensuring its
interchangeability and defines its physical and mechanical requirements.
- Draft23 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies safety requirements, certain functional requirements, and marking of valves and other components with similar bodies, hereinafter called valves, for use in refrigerating systems including heat pumps.
This document includes requirements for valves with extension pipes.
This document describes the procedure to be followed when designing valve parts subjected to pressure as well as the criteria to be used in the selection of materials.
This document describes methods by which reduced impact values at low temperatures may be taken into account in a safe manner.
This document applies to the design of bodies and bonnets for pressure relief devices, including bursting disc devices, with respect to pressure containment but it does not apply to any other aspects of the design or application of pressure relief devices.
In addition, this document is applicable to valves with a maximum operating temperature not exceeding 200 °C and a maximum allowable pressure not exceeding 160 bar[1].
[1] 1 bar = 0,1 MPa.
- Draft9 pagesEnglish languagesale 10% offe-Library read for1 day
This document applies primarily to copper alloy and stainless steel ball valves with dimensions DN 6 to DN 100, for installations in buildings for potable water supply up to PN16 and a maximum distribution temperature of 65 °C. Occasional excursions up to 90 °C are permitted for a period of 1 h maximum.
The ball valves are classified by their nominal pressure being either PN10 or PN16.
This document specifies:
- the requirements of the materials and the design of ball valves;
- the mechanical, hydraulic and acoustic requirements of ball valves;
- the test methods to verify the requirements of ball valves;
- the marking requirements of ball valves.
- Draft28 pagesEnglish languagesale 10% offe-Library read for1 day
Amendment to update valve requirements as presented in N1352
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard covers the vapour transfer valve, used for the transfer of vapour between the tank
compartment and the pipework connecting to the vapour collection adaptor.
This European Standard specifies the performance requirements and the critical dimensions of the vapour
transfer valve. It also specifies the tests necessary to verify the compliance of the equipment with this
European Standard. The equipment specified by this standard is suitable for use with liquid petroleum
products and other dangerous substances of Class 3 of ADR [2] which have a vapour pressure not exceeding
110 kPa at 50 °C and petrol, and which have no sub-classification as toxic or corrosive.
- Draft4 pagesEnglish languagesale 10% offe-Library read for1 day
The intention is to add a further Annex to EN 161 regarding a method for the determination of Performance Level (PL): This Annex is only applicable to valves or valve functions which are declared to comply with performance level requirements (PL) according to EN ISO 13849-1:2008, clauses 1, 2, 3, 4.1, 4.2, 4.5, 7, 8, 9, 10, 11, and annexes C.4, E, and F. This Annex specifies a set of additional requirements to EN 161 to determine the probability of dangerous failures per hour for continuous or high demand mode (PFHD) and the performance level (PL) for electromechanical valves or valve functions used in industrial and thermoprocessing applications (e. g. EN 746-2).
- Draft25 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies requirements for the valve seat and body pressure/ temperature ratings and the design, including materials, dimensions, operation, performance, testing and marking of lubricated, soft seated and lined plug valves having a steel shell. It also specifies anti-static requirements, an optional fire tested design and the option of a steel or cast iron plug.
- Draft27 pagesEnglish languagesale 10% offe-Library read for1 day