ISO/TC 146/SC 6/WG 17 - Sensory testing of indoor air
Essai sensoriel de l'air intérieur
General Information
This document specifies a laboratory test method using test chambers defined in ISO 16000-9 and further specified in EN 16516 and evaluation procedures for the determination of odours emitted from building products and materials. Sampling, transport and storage of materials under test, as well as preparation of test specimens are described in ISO 16000-11 and further specified in EN 16516.
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard42 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard35 pagesEnglish languagesale 15% off
- Standard37 pagesFrench languagesale 15% off
- Draft35 pagesEnglish languagesale 15% off
- Draft37 pagesFrench languagesale 15% off
ISO 16000-30:2014 specifies sensory testing and the evaluation of indoor odours using human panels. Sensory testing can be performed on site or in laboratories; in the latter case, by means of air in sampling containers which were collected from the site. The olfactory testing is appropriate for office and administration buildings, assembly halls, residential buildings, and other habitable rooms in which the comfort and health of the occupants is of interest. The test criteria in ISO 16000-30:2014 specifies are not applicable to factory buildings and workshops or other rooms in which odours unavoidably stem from the production processes (kitchens, bakeries etc.). If an odour evaluation of such rooms is undertaken without the odour-producing processes, it is necessary to take into account that there is a possibility that the processes have influenced and changed the odour of the room through the adsorption of odorous compounds. Sensory odour tests of indoor air can meet a variety of objectives. These include finding the cause(s) of unpleasant or objectionable odours, determining the reasonability of odours and the usability of affected rooms, and inspecting the results of renovation work. When seeking the cause of odours, it is wise to conduct additional laboratory tests on samples of the component materials according to ISO 16000‑28. In the process of locating odour sources by means of olfactory tests, it is necessary to take into account the fact that the odour compounds can accumulate on other surfaces, which exacerbates the problem.
- Standard31 pagesEnglish languagesale 15% off
- Standard37 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard34 pagesFrench languagesale 15% off