TP042 - Rules on conditions and restrictions regarding the construction and use of installations and the performance of activities in the electricity network safety zone
Rules on conditions and restrictions regarding the construction and use of installations and the performance of activities in the electricity network safety zone
Pravilnik o pogojih in omejitvah gradenj, uporabe objektov ter opravljanja dejavnosti v območju varovalnega pasu elektroenergetskih omrežij
Datum prenehanja veljavnosti 22.03.2014 Se še uporablja!!
General Information
Specifies the general requirements that shall be met for the design and construction of new overhead lines to ensure that the line is suitable for its purpose with regard to safety of persons, maintenance, operation and environmental considerations.
- Standard253 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard269 pagesGerman languagesale 10% offe-Library read for1 day
- Standard – translation257 pagesSlovenian languagesale 10% offe-Library read for1 day
This European Standard contains the requirements for the design and erection of earthing 111 systems of electrical installations, in systems with nominal voltage above 1 kV a.c., so as to 112 provide safety and proper functioning for the use intended.
- Standard66 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation66 pagesSlovenian languagesale 10% offe-Library read for1 day
This part of IEC 61936 provides common rules for the design and the erection of electrical power installations in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this standard, an electrical power installation is considered to be one of the following:
a) Substation, including substation for railway power supply
b) Electrical installations on mast, pole and tower
Switchgear and/or transformers located outside a closed electrical operating area
c) One (or more) power station(s) located on a single site
The installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded.
d) The electrical system of a factory, industrial plant or other industrial, agricultural,
commercial or public premises
The electrical power installation includes, among others, the following equipment:
– rotating electrical machines;
– switchgear;
– transformers and reactors;
– converters;
– cables;
– wiring systems;
– batteries;
– capacitors;
– earthing systems;
– buildings and fences which are part of a closed electrical operating area;
– associated protection, control and auxiliary systems;
– large air core reactor.
NOTE In general, a standard for an item of equipment takes precedence over this standard. This standard does not apply to the design and erection of any of the following:
– overhead and underground lines between separate installations;
– electric railways;
– mining equipment and installations;
– fluorescent lamp installations;
– installations on ships and off-shore installations;
– electrostatic equipment (e.g. electrostatic precipitators, spray-painting units);
– test sites;
– medical equipment, e.g. medical X-ray equipment.
This standard does not apply to the design of factory-built, type-tested switchgear for which separate IEC standards exist. This standard does not apply to the requirements for carrying out live working on electrical installations. If not otherwise required in this standard, for low-voltage electrical installations the standard series IEC 60364 applies.
- Standard119 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard – translation116 pagesSlovenian languagesale 10% offe-Library read for1 day
- National annex47 pagesSlovenian languagesale 10% offe-Library read for1 day
- National annex43 pagesSlovenian languagesale 10% offe-Library read for1 day