This European Standard specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 μg/m3. This concentration range represents the certification range for SO2 for the type approval test. The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources. The results are expressed in μg/m3 (at 20 °C and 101,3 kPa). This standard contains information for different groups of users. Clauses 5 to 7 and Annexes C and D contain general information about the principles of sulphur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of sulphur dioxide analysers. These sections contain information about: - Type-approval test conditions, test procedures and test requirements; - Analyser performance requirements; - Evaluation of the type-approval test results; - Evaluation of the uncertainty of the measurement results of the sulphur dioxide analyser based on the typeapproval test results. Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical measurements of sulphur dioxide in ambient air. These sections contain information about: - Initial installation of the analyser in the monitoring network and acceptance testing; - Ongoing quality assurance/quality control; - Calculation and reporting of measurement results; - Evaluation of the uncertainty of measurement results under practical monitoring conditions.

  • Standard
    104 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    56 pages
    English language
    sale 15% off
  • Standard
    56 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    57 pages
    French language
    sale 15% off