General Information
This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts.
Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test. Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P, D and DIS) are specified using the maximum t...view more
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft28 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements for light fire storage units providing protection against fire.
The method of test is specified to determine the ability of light fire storage units to protect paper media from the effects of fire. Two levels of fire exposure periods (LFS 30 P and LFS 60 P) are specified using the maximum temperature increase permitted within the storage space of the light fire storage unit.
Requirements are also specified for the test specimen, the technical docu...view more
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft17 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of the European Standard EN 1047 specifies requirements for data rooms and data containers. It includes a method of test for the determination of the ability of data rooms and data containers to protect temperature and humidity sensitive data media (see 3.5) and hardware systems (see 3.6) from the effects of fire. A test method for measuring the resistance to mechanical stress (impact test) provided by data rooms type B and data containers is also specified.
Requirements are also spec...view more
- Standard35 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.
- Standard54 pagesEnglish language
sale 10% off- e-Library read for1 day
This document establishes the basis for testing and classifying secure safe cabinets.
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
EN 1143-2 specifies requirements and tests methods for deposit systems, and classifies the systems according to their burglary resistance and their resistance to the theft of deposits. This European Standard comprises two types of deposit system: - night safes which provide depositing services for the customers of financial institutions without giving access to the content of the night safe. - deposit safes which enable the personnel of a company to place money or valuables in safe custody witho...view more
- Standard50 pagesEnglish language
sale 10% off- e-Library read for1 day
This International Standard provides suggested guidelines for four temperature and humidity macro-environments for archives that contain a variety of recording media, based on the corresponding ISO storage standards for those media. Whenever possible, this International Standard recommends that users follow the storage environments in the ISO storage standards. This International Standard does not replace those ISO storage standards. In addition to environment recommendations, those standards al...view more
- Standard10 pagesEnglish language
sale 15% off- Standard15 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 60950 specifies requirements for information technology equipment (ITE) with self contained data storage systems that contain hazardous moving parts. These data storage systems are typically large enough to permit a person to enter completely, however, the systems also include similar large equipment permitting complete limb or head access to the area containing hazardous moving parts. These requirements are additional to the relevant requirements in IEC 60950-1. The maximum thr...view more
- Standard15 pagesEnglish language
sale 10% off- e-Library read for1 day
Data rooms and data containers are fire protection security products whose purpose is to protect temperature and humidity sensitive data media and hardware systems from the effects of fire. These fire resistance products do not provide any defined protection against burglary.
Based on these objectives, the CEN/TC 263 Working Group WG2 Fire Resistance unanimously noted at its meeting on 8 March 2012 that the requirement for a certified high security lock according to EN 1300 for data rooms and d...view more
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day