This document specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system. The components comply either with the requirements of EN 54 or with a manufacturer’s specification where there is no EN 54 standard. This document only includes system requirements when these are necessary for compatibility assessment.
This document covers transmission path onl...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard includes requirements for warning devices used for notification in intrusion and hold up alarm systems installed in buildings. Four grades of warning device are described corresponding to each of the four security grades given in EN 50131-1. Requirements are also given for four environmental classes covering applications in indoor and outdoor locations as specified in EN 50130-5.
This European Standard does not deal with requirements for compliance with EC regulatory Dire...
view more

    • sale 10% off
    • Standard
      36 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements for Security Fog Devices connected to an I&HAS. It covers application and performance and also gives the necessary tests and trials to ensure efficiency and reliability of such obscuration devices.
This European Standard also gives guidance on the criteria for design, installation, operation and maintenance of Security Fog Devices.
A Security Fog Device is not considered to be a component of an I&HAS and no requirements are given relating to th...
view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This European Standard establishes the basis for testing and classifying free-standing safes, built-in safes (floor and wall), ATM safes and ATM bases, strongroom doors and strongrooms (with or without a door) according to their burglary resistance. This European Standard does not cover testing and classifying Deposit Systems and ATM systems.

    • sale 10% off
    • Standard
      54 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, test methods and performance criteria for fire alarm sounders, including voice sounders, in a fixed installation intended to signal an audible warning between the fire detection and fire alarm systems and the occupants of a building (see EN 54-1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of fire alarm sounders to this EN.
This European Standard is not intended to cover:
a)   lou...
view more

    • sale 10% off
    • Standard
      67 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements for high security locks (HSL) for reliability, resistance to burglary and unauthorized opening with methods of testing. It also provides a scheme for classifying HSL in accordance with their assessed resistance to burglary and unauthorized opening.
It applies to mechanical and electronic HSL. The following features may be included as optional subjects but they are not mandatory:
a)   recognized code for preventing code altering and/or enabling/disabl...
view more

    • sale 10% off
    • Standard
      55 pages
      English language
    • e-Library read for
      1 day

This standard specifies the requirements for the performance, reliability and security characteristics of alarm transmission systems.
It covers the general requirements for connections providing signalling between an alarm system at a supervised premises and annunciation equipment at an alarm receiving centre.
EN 50136-1 Applies to transmission systems for all types of alarm messages such as fire, intrusion, access control, social alarm, etc. Different types of alarm system may in addition to ...
view more

    • sale 10% off
    • Amendment
      9 pages
      English language
    • e-Library read for
      1 day

This draft European Standard specifies requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011).
This European standard provides for the assessment of verification of consistency of performance (AVCP) of point smoke detectors to this EN.
For other types of smoke detector, or smoke detectors worki...
view more

    • sale 10% off
    • Standard
      79 pages
      English language
    • e-Library read for
      1 day

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.
Lock state contacts are installed in windows or doors and windows or doorframes to allow to monitor the lock/unlock status only or the lock/unlock status combined with the open/close status of a window/door simul...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, test methods and performance criteria for point heat detectors intended for use in fire detection and fire alarm systems installed in and around buildings (see EN 54-1:2011).
This European Standard provides for the assessment of verification of constancy of performance (AVCP) of point heat detectors to this EN.
For other types of heat detector, or for detectors intended for use in other environments, this standard should only be used for guida...
view more

    • sale 10% off
    • Standard
      62 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive infrared detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive infrared detectors intended for use outdoors.
A detector shall fulfil all the requirements of the specified grade.
Functions additional to the mandatory functions specified in this st...
view more

    • sale 10% off
    • Standard
      45 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the requirements, performance criteria and testing procedures for PS to be used as part of Intrusion and Hold up Alarm Systems. The PS will either be an integral part of an I&HAS component or stand-alone. The control functions of the PS may be incorporated as part of the PS device, or may be provided by another I&HAS component, e.g. a CIE.
This European Standard is not applicable when the PS requirements for I&HAS components are included within the relevant prod...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day

Harmonise system requirements with requirements for system components specified in standard published since EN 50131-1:2006 was published.

    • sale 10% off
    • Amendment
      14 pages
      English language
    • e-Library read for
      1 day

This International Standard specifies the requirements for establishing, implementing, maintaining
and continually improving an information security management system within the context of the
organization. This International Standard also includes requirements for the assessment and treatment
of information security risks tailored to the needs of the organization. The requirements set out in this
International Standard are generic and are intended to be applicable to all organizations, rega...
view more

    • sale 10% off
    • Standard
      35 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      31 pages
      Slovenian language
    • e-Library read for
      1 day

This European Standard applies to intrusion alarm equipment using radio frequency (RF) links and located on protected premises. It does not cover long-range radio transmissions.
This European Standard defines the terms used in the field of intrusion alarm equipment using radio frequency links as well as the requirements relevant to the equipment.

    • sale 10% off
    • Standard
      20 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for ALDDR inside buildings and provides four security grades 1 to 4 (see EN 50131-1), specific or non-specific wire or wire-free ALDDR, and uses environmental classes I to IV (see EN 50130-5).
An ALDDR fulfils all the requirements of the specified grade.
The ALDDR detects an intruder inside a predefined area.
This standard covers ALDDR using both pulsed and continuous wave laser operation technologies according to LIDAR principle (Light Detection And Ranging). ...
view more

    • sale 10% off
    • Technical specification
      41 pages
      English language
    • e-Library read for
      1 day

This European Standard is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This European Standard does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks fr...
view more

    • sale 10% off
    • Standard
      41 pages
      English language
    • e-Library read for
      1 day

This Technical Specification provides recommendations for those methods of setting and unsetting an Intrusion Alarm System (IAS) complying with EN 50131-1 that will reduce unwanted alarms arising from “operator error” in setting and unsetting the IAS and provide confidence that the conditions in which the system is installed are conducive to system reliability during the “set” period.
This document details optional methods by which these goals may be achieved, either in isolation, or in conjunc...
view more

    • sale 10% off
    • Technical specification
      17 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is applicable to Active Infrared Beam Detectors (AIBDs) installed inside buildings and used as part of intrusion alarm systems.
It specifies four security Grades 1 to 4 (in accordance with EN 50131 1) and uses environmental Classes I to IV (in accordance with EN 50130 5).
This standard covers only AIBDs using interruption based technology. Other technologies i.e. Doppler based technology are not covered by this document.
Functions additional to the mandatory funct...
view more

    • sale 10% off
    • Technical specification
      36 pages
      English language
    • e-Library read for
      1 day

Change of the following chapters, to allow products to pass the relevant test section based on the relevant Annex : 6.6.3 Immunity to Hard objects hitting the glass & Annex A

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this ...view more

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Amendment
      4 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection and fire alarm systems installed in and around buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one carbon monoxide (CO) sensor and optionally one or more heat sensors, utilizing the combination of the detected phenomena. This European Standard covers only modes...view more

    • sale 10% off
    • Standard
      107 pages
      English language
    • e-Library read for
      1 day

This European Standard applies to non-resettable line-type heat detectors consisting of a sensing element using an electrical sensor cable which can be connected to a sensor control unit or either directly or through an interface module to a control and indicating equipment intended for use in fire detection and fire alarm systems installed in and around buildings and civil engineering works (see EN 54 1:2011).
The non-resettable sensing element has a fixed temperature alarm threshold and does ...
view more

    • sale 10% off
    • Standard
      66 pages
      English language
    • e-Library read for
      1 day

Corrigendum to add: EN 60839-11-2 supersedes EN 50133-7:1999

    • sale 10% off
    • Corrigendum
      1 page
      English language
    • e-Library read for
      1 day

This International Standard specifies the requirements for an environmental management system
that an organization can use to enhance its environmental performance. This International Standard
is intended for use by an organization seeking to manage its environmental responsibilities in a
systematic manner that contributes to the environmental pillar of sustainability.
This International Standard helps an organization achieve the intended outcomes of its environmental
management system, whi...
view more

    • sale 10% off
    • Standard
      46 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      49 pages
      German language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      66 pages
      Slovenian and English language
    • e-Library read for
      1 day

ISO 9001:2015 specifies requirements for a quality management system when an organization:
a) needs to demonstrate its ability to consistently provide products and services that meet customer and applicable statutory and regulatory requirements, and
b) aims to enhance customer satisfaction through the effective application of the system, including processes for improvement of the system and the assurance of conformity to customer and applicable statutory and regulatory requirements.
All the r...
view more

    • sale 10% off
    • Standard
      42 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard – translation
      55 pages
      Slovenian and English language
    • e-Library read for
      1 day

This part of IEC 60839 defines the minimum requirements and guidance for the installation
and operation of electronic access control systems (EACS) and/or accessory equipment to
meet different levels of protection.
This standard includes requirements for planning, installation, commissioning, maintenance
and documentation for the application of EACS installed in and around buildings and areas.
The equipment functions are defined in the IEC 60839-11-1.
When the EACS includes functions relat...
view more

    • sale 10% off
    • Standard
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in buildings (see EN 54 1:2011), incorporating in one mechanical enclosure at least one optical or ionization smoke sensor and at least one heat sensor. The overall fire detection performance is determined utilizing the combination of the detected phenomena.
This European Standard provides for the assessment and verification ...
view more

    • sale 10% off
    • Standard
      96 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies requirements, test methods and performance criteria for line detectors using an optical beam that detect smoke by utilizing the attenuation and/or changes in attenuation of an optical beam, for use in fire detection and fire alarm systems installed in buildings (see EN 54 1:2011).
This European Standard provides for the assessment and verification of constancy of performance (AVCP) of line detectors using an optical beam to this EN.
This European Standard does ...
view more

    • sale 10% off
    • Standard
      71 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).
It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5).
This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetrat...
view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

CLC/TS 50131-9 is available for use where alarm verification methods are considered necessary. It provides recommendations for the addition and use of alarm verification technology in Intrusion and Hold-up Alarm Systems (I&HAS) installed to comply with EN 50131-1. These recommendations should be incorporated into the respective standards in the EN 5013x series. This Technical Specification does not detail methods of alarm verification relying solely on Alarm Receiving Centre (ARC) procedures, bu...view more

    • sale 10% off
    • Technical specification
      28 pages
      English language
    • e-Library read for
      1 day

EN 50131-10 specifies requirements for SPT used in I&HAS to transmit alarm and other messages to a location remote from the supervised premises. This European Standard gives specific requirements for SPT used in Intrusion and Hold-up Alarm Systems (I&HAS) and should be used in combination with EN 50136-2. The requirements of this European Standard apply to different types of SPT including separate SPT, SPT located within the housings of other I&HAS components and also when the SPT functionality ...view more

    • sale 10% off
    • Standard
      19 pages
      English language
    • e-Library read for
      1 day

EN 1143-2 specifies requirements and tests methods for deposit systems, and classifies the systems according to their burglary resistance and their resistance to the theft of deposits. This European Standard comprises two types of deposit system: - night safes which provide depositing services for the customers of financial institutions without giving access to the content of the night safe. - deposit safes which enable the personnel of a company to place money or valuables in safe custody witho...view more

    • sale 10% off
    • Standard
      50 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the minimum equipment requirements for the performance, reliability, resilience, security and safety characteristics of the receiving centre transceiver (RCT) installed in ARC and used in alarm transmission systems.

    • sale 10% off
    • Standard
      25 pages
      English language
    • e-Library read for
      1 day

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do n...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This Technical Specification is for dedicated hold-up devices in buildings, e.g. deliberately operated hold-up devices which can be triggered to create a hold-up alarm signal or message. It provides four security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free hold-up devices and uses Environmental Classes I-IV (see EN 50130-5). This Technical Specification does not include requirements for hold-up devices intended for use outdoors, or for mobile hold-up devices or for d...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for passive surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this ...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this st...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for microwave detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for combined passive infrared and ultrasonic detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for combined passive infra red and ultrasonic detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the ma...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

This standard is for combined passive infrared and microwave detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be ...view more

    • sale 10% off
    • Addendum
      6 pages
      English language
    • e-Library read for
      1 day

CLC/TS 50131-2-10 provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free lock state contacts, and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5. The purpose of a lock state contact (magnetic) is to detect the lock/unlock state only or the lock/unlock state combined with the opening status/displacement from the defined closed position of a window or door simulta...view more

    • sale 10% off
    • Technical specification
      32 pages
      English language
    • e-Library read for
      1 day

This European Standard is for active surface mounted glass break detectors installed in buildings and provides for security Grades 1 to 4, specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV. This European Standard does not include requirements for active surface mounted glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory functions specified in this st...view more

    • sale 10% off
    • Amendment
      6 pages
      English language
    • e-Library read for
      1 day

This European Standard is for passive acoustic glass break detectors installed in buildings and provides for security Grades 1 to 4 (see EN 50131-1), specific or non-specific wired or wire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This European Standard does not include requirements for passive acoustic glass break detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified Grade. Functions additional to the mandatory function...view more

    • sale 10% off
    • Amendment
      5 pages
      English language
    • e-Library read for
      1 day

This European Standard specifies the general equipment requirements for the performance, reliability, resilience, security and safety characteristics of supervised premises transceiver (SPT) installed in supervised premises and used in alarm transmission systems (ATS). A supervised premises transceiver can be a stand-alone device or an integrated part of an alarm system. These requirements also apply to SPT’s sharing means of interconnection, control, communication and power supplies with other ...view more

    • sale 10% off
    • Standard
      30 pages
      English language
    • e-Library read for
      1 day

This part of IEC 60839 specifies the minimum functionality, performance requirements and test methods for electronic access control systems and components used for physical access (entry and exit) in and around buildings and protected areas. It does not include requirements for access point actuators and sensors. This standard is not intended to cover requirements for off premise transmission associated with intrusion or hold up alarm signals. This standard applies to electronic access control s...view more

    • sale 10% off
    • Standard
      61 pages
      English language
    • e-Library read for
      1 day

This Technical Specification details methods and tests for compatibility assessment of system components, including a CIE, intended to be used in intruder and hold up alarm systems complying with EN 50131-1. This includes: - I&HAS components for which EN 50131 series product standards exist; - I&HAS components for which no EN 50131 series product standards currently exist; - I&HAS components that include additional functionality outside the scope of EN 50131-1 or shared with another system; - no...view more

    • sale 10% off
    • Technical specification
      14 pages
      English language
    • e-Library read for
      1 day