ASTM F1692-01(2023)
(Test Method)Standard Test Method for Life Evaluation of a Turbine-Powered Nozzle for Household Central Vacuum Cleaning Systems
Standard Test Method for Life Evaluation of a Turbine-Powered Nozzle for Household Central Vacuum Cleaning Systems
SIGNIFICANCE AND USE
4.1 The test results provide an indication of the turbine-powered nozzle life. The end of turbine life will be judged in accordance with 3.1.1.
SCOPE
1.1 This test method covers the turbine-powered nozzle used in household central vacuum cleaning systems.
1.2 This test method provides a test for determining the operating turbine life in hours by an accelerated laboratory procedure. The turbine is tested while mounted and operated in the power nozzle.
1.3 This test method covers only the turbine-powered nozzle. The system used to provide the airflow source is not under consideration.
1.4 This test method is limited to the determination of turbine life for a household turbine-powered nozzle.
1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F1692 − 01 (Reapproved 2023)
Standard Test Method for
Life Evaluation of a Turbine-Powered Nozzle for Household
1
Central Vacuum Cleaning Systems
This standard is issued under the fixed designation F1692; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope chrometer (the Measurement of Wet- and Dry-Bulb Tem-
peratures)
1.1 This test method covers the turbine-powered nozzle
F431 Specification for Air Performance Measurement Ple-
used in household central vacuum cleaning systems.
num Chamber for Vacuum Cleaners
1.2 This test method provides a test for determining the
F608 Test Method for Evaluation of Carpet Embedded Dirt
operating turbine life in hours by an accelerated laboratory
Removal Effectiveness of Household/Commercial
procedure. The turbine is tested while mounted and operated in
Vacuum Cleaners
the power nozzle.
F655 Specification for Test Carpets and Pads for Vacuum
3
1.3 This test method covers only the turbine-powered Cleaner Testing (Withdrawn 2022)
nozzle. The system used to provide the airflow source is not
3. Terminology
under consideration.
3.1 Definitions of Terms Specific to This Standard:
1.4 This test method is limited to the determination of
3.1.1 turbine stoppage—for turbine-powered nozzles, any
turbine life for a household turbine-powered nozzle.
failure integral with the turbine assembly such as housing(s),
1.5 The values stated in inch-pound units are to be regarded
bearings, or any other component judged to be integral with the
as the standard. The values given in parentheses are for
turbine.
information only.
4. Significance and Use
1.6 This standard does not purport to address all of the
4.1 The test results provide an indication of the turbine-
safety concerns, if any, associated with its use. It is the
powered nozzle life. The end of turbine life will be judged in
responsibility of the user of this standard to establish appro-
accordance with 3.1.1.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
5. Apparatus and Materials
1.7 This international standard was developed in accor-
5.1 Voltage Regulator System—to control the input voltage
dance with internationally recognized principles on standard-
to the vacuum cleaner or airflow source. The regulator must be
ization established in the Decision on Principles for the
capable of maintaining the vacuum cleaner or the airflow
Development of International Standards, Guides and Recom-
source’s rated voltage 61 % and rated frequency 61 Hz with
mendations issued by the World Trade Organization Technical
a waveform that is essentially sinusoidal with 3 % maximum
Barriers to Trade (TBT) Committee.
harmonic distortion for the duration of the test.
2. Referenced Documents
5.2 Voltmeter, to provide measurements accurate to within
2
61 %.
2.1 ASTM Standards:
D75 Practice for Sampling Aggregates
5.3 Timer and Switch, having the capacity to control the
E337 Test Method for Measuring Humidity with a Psy-
off/on duty cycle of the nozzle and airflow source during the
life test.
1
5.4 Wattmeter, to provide measurements accurate to within
This test method is under the jurisdiction of ASTM Committee F11 on Vacuum
Cleaners and is the direct responsibility of Subcommittee F11.30 on Durability-
61 %.
Reliability.
1
5.5 Sharp-Edge Orifice Plate—The orifice, 1 ⁄4-in. (32-mm)
Current edition approved Sept. 1, 2023. Published September 2023. Originally
approved in 1996. Last previous edition approved in 2016 as F1692 – 01 (2016).
diameter, shall be in accordance with the orifice plate illus-
DOI: 10.1520/F1692-01R23.
trated in Specification F431.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F1692 − 01 (2023)
5.6 Plenum Chamber, conforming to the plenum chamber shall be restrained suitably in the horizontal operating plane yet
specifications stated in Specification F431. allowed freedom of movement in the vertical plane for
operation.
5.7 Water Manometer, or equi
...