ASTM D2467-05
(Specification)Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80
SCOPE
1.1 This specification covers poly(vinyl chloride) (PVC) Schedule 80 pipe fittings. Included are requirements for materials, workmanship, dimensions, and burst pressure.
Note 1—CPVC plastic pipe fittings, which were formerly included in this standard, are now covered in Specification F 439.
1.2 The products covered by this specification are intended for use with the distribution of pressurized liquids only, which are chemically compatible with the piping materials. Due to inherent hazards associated with testing components and systems with compressed air or other compressed gases, some manufacturers do not allow pneumatic testing of their products. Consult with specific product/component manufacturers for their specific testing procedures prior to pneumatic testing.
Note 2—Pressurized (compressed) air or other compressed gases contain large amounts of stored energy, which present serious safety hazards should a system fail for any reason.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this specification.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
The following safety hazards caveat pertains only to the test method portion, Section , of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: D 2467 – 05
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule
1
80
This standard is issued under the fixed designation D 2467; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope of this standard to establish appropriate safety and health
practices and determine the applicability of regulatory limita-
1.1 This specification covers poly(vinyl chloride) (PVC)
tions prior to use.
Schedule 80 pipe fittings. Included are requirements for mate-
rials, workmanship, dimensions, and burst pressure.
2. Referenced Documents
2
NOTE 1—CPVC plastic pipe fittings, which were formerly included in
2.1 ASTM Standards:
this standard, are now covered in Specification F 439.
D 618 Practice for Conditioning Plastics for Testing
1.2 The products covered by this specification are intended
D 1599 Test Method for Resistance to Short-Time Hydrau-
for use with the distribution of pressurized liquids only, which
lic Pressure of Plastic Pipe, Tubing, and Fittings
are chemically compatible with the piping materials. Due to
D 1600 Terminology for Abbreviated Terms Relating to
inherent hazards associated with testing components and sys-
Plastics
tems with compressed air or other compressed gases, some
D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
manufacturersdonotallowpneumatictestingoftheirproducts.
Compounds and Chlorinated Poly(Vinyl Chloride)
Consult with specific product/component manufacturers for
(CPVC) Compounds
their specific testing procedures prior to pneumatic testing.
D 1785 Specification for Poly(Vinyl Chloride) (PVC) Plas-
tic Pipe, Schedules 40, 80, and 120
NOTE 2—Pressurized (compressed) air or other compressed gases
D 2122 Test Method for Determining Dimensions of Ther-
contain large amounts of stored energy, which present serious safety
moplastic Pipe and Fittings
hazards should a system fail for any reason.
D 2749 Symbols for Dimensions of Plastic Pipe Fittings
1.3 The text of this specification references notes, footnotes,
F 412 Terminology Relating to Plastic Piping Systems
and appendixes which provide explanatory material. These
F 439 Specification for Chlorinated Poly (Vinyl Chloride)
notesandfootnotes(excludingthoseintablesandfigures)shall
(CPVC) Plastic Pipe Fittings, Schedule 80
not be considered as requirements of this specification.
F 1498 Specification for Taper Pipe Threads 60° for Ther-
1.4 The values stated in inch-pound units are to be regarded
moplastic Pipe and Fittings
as the standard. The values given in parentheses are provided
3
2.2 Federal Standard:
for information only.
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
1.5 The following safety hazards caveat pertains only to the
4
2.3 National Sanitation Foundation Standards:
test method portion, Section 8, of this specification. This
standarddoesnotpurporttoaddressallofthesafetyconcerns,
ifany,associatedwithitsuse.Itistheresponsibilityoftheuser
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
1 3
This specification is under the jurisdiction ofASTM Committee F17 on Plastic AvailablefromStandardizationDocumentsOrderDesk,Bldg.4SectionD,700
Piping Systems and is the direct responsibility of Subcommittee F17.10 on Fittings. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
4
Current edition approved August 1, 2005. Published August 2005. Originally Available from the National Sanitation Foundation, P.O. Box 1468,AnnArbor,
e1
approved in 1965. Last previous edition approved in 2002 as D 2467 – 04 . MI 48106.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D 2467 – 05
Standard No. 14 for Plastic Piping Components and Related 6.1.5 The minimum inside diameter of the fittings shall
Materials be not less than the minimum specified inside diameter of the
Standard No. 61 for Drinking Water Systems corresponding size of Schedule 80 pipe. This is calculated as
Components—Health Effects follows:
~minimumOD!223 ~maximumwall! 5minimumID! (1)
3. Terminology
6.1.6 Minimum dimensions have zero negative tolerance.
3.1 General—Definitions are in accordance with Terminol-
TolerancesonotherdimensionsareshowninTable1andTable
ogy F 412 and abbreviations are in accordance with
...
Questions, Comments and Discussion