Standard Test Method for Efficacy of Sanitizers Recommended for Inanimate, Hard, Nonporous Non-Food Contact Surfaces

SIGNIFICANCE AND USE
4.1 This test method shall be used to determine if a chemical intended for use as a non-food contact sanitizer or as a one-step cleaner-sanitizer provides percent reductions of the selected test organisms on treated carriers as compared to control.
SCOPE
1.1 This test method is used to evaluate the antimicrobial efficacy of sanitizers on precleaned, inanimate, hard, nonporous, non-food contact surfaces against Staphylococcus aureus, or Klebsiella pneumoniae or Enterobacter aerogenes, or a combination thereof. Appropriate modifications to the method may be required when testing organisms not specified herein. When utilizing test surfaces not described herein (see Test Method E2274) or when evaluating spray-based or towelette-based antimicrobial products, modifications may also be required.  
1.2 This test method may also be used to evaluate the antimicrobial efficacy of one-step cleaner-sanitizer formulations recommended for use on lightly soiled, inanimate, nonporous, non-food contact surfaces.  
1.3 It is the responsibility of the investigator to determine whether Good Laboratory Practices (GLP) are required and to follow them where appropriate (see section 40 CFR, 160 or as revised.)  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard may involve hazardous materials, chemicals and microorganisms and should be performed only by persons who have had formal microbiological training. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Mar-2014
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM E1153-14 - Standard Test Method for Efficacy of Sanitizers Recommended for Inanimate, Hard, Nonporous Non-Food Contact Surfaces
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM E1153-14 - Standard Test Method for Efficacy of Sanitizers Recommended for Inanimate, Hard, Nonporous Non-Food Contact Surfaces
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E1153 − 14
Standard Test Method for
Efficacy of Sanitizers Recommended for Inanimate, Hard,
1
Nonporous Non-Food Contact Surfaces
This standard is issued under the fixed designation E1153; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
1.1 This test method is used to evaluate the antimicrobial 2.1 ASTM Standards:
efficacy of sanitizers on precleaned, inanimate, hard, D1193Specification for Reagent Water
nonporous, non-food contact surfaces against Staphylococcus E1054Test Methods for Evaluation of Inactivators of Anti-
aureus,or Klebsiella pneumoniae or Enterobacter aerogenes, microbial Agents
or a combination thereof. Appropriate modifications to the E2274Test Method for Evaluation of Laundry Sanitizers
method may be required when testing organisms not specified and Disinfectants
herein. When utilizing test surfaces not described herein (see E2756Terminology Relating toAntimicrobial andAntiviral
Test Method E2274) or when evaluating spray-based or Agents
towelette-basedantimicrobialproducts,modificationsmayalso 2.2 Federal Standard:
3
be required. 40CFR, Part 160, Good Laboratory Practice Standards
1.2 This test method may also be used to evaluate the
3. Terminology
antimicrobial efficacy of one-step cleaner-sanitizer formula-
3.1 Terms used in this test method are defined in Terminol-
tions recommended for use on lightly soiled, inanimate,
ogy E2756.
nonporous, non-food contact surfaces.
3.2 Definitions of Terms Specific to This Standard:
1.3 It is the responsibility of the investigator to determine
3.2.1 accuracy, n—ameasureofthedegreeofconformityof
whether Good Laboratory Practices (GLP) are required and to
a value generated by a specific procedure to the assumed or
follow them where appropriate (see section 40 CFR, 160 or as
accepted true value, and includes both precision and bias.
revised.)
3.2.2 ambient temperature, n—temperature of the environ-
1.4 The values stated in SI units are to be regarded as
ment in which a test method is performed.
standard. No other units of measurement are included in this
3.2.3 antimicrobial, adj—describes an agent that kills or
standard.
inactivates microorganisms or suppresses their growth or
1.5 This standard may involve hazardous materials, chemi-
reproduction.
cals and microorganisms and should be performed only by
3.2.4 bias, n—a systematic error that contributes to the
persons who have had formal microbiological training.This
difference between the mean of a large number of test results
standard does not purport to address all of the safety concerns,
and an accepted reference value.
if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health
3.2.5 cleaner-sanitizer, n—a physical or chemical agent that
practices and determine the applicability of regulatory limita-
removes soil from an object and reduces numbers of microor-
tions prior to use.
ganisms on non-food contact surfaces.
1 2
This test method is under the jurisdiction of ASTM Committee E35 on For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Pesticides, Antimicrobials, and Alternative Control Agents and is the direct contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
responsibility of Subcommittee E35.15 on Antimicrobial Agents. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved April 1, 2014. Published May 2014. Originally the ASTM website.
ε1
3
approved 1987. Last previous edition approved in 2010 as E1153–03(2010) . Available from the Superintendent of Documents, U.S. Government Printing
DOI: 10.1520/E1153-14. Office, Washington, DC 20402.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1153 − 14
3.2.6 carrier, n—a surrogate surface or matrix that facili- 5.10 Graduated Cylinders, recommended sizes; 100 and
tates the interaction of test microorganisms and treatment(s). 500 mL.
3.2.7 effıcacy, n—the proven performance of a product
5.11 Flaming Apparatus—A bunsen burner or other appro-
established under defined conditions of testing.
priate heat sterilizer.
3.2.8 inoculum, n—the viable microorganisms used to con-
5.12 Mixer—A “vortex” mixer is recommended.
taminate a sample, device or surface, often expressed as to
5.13 Timer—A reliable stopwatch or laboratory timer ca-
number and type.
pable of measuring elapsed time in seconds and minutes.
3.2.9 neutralization, n—t
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: E1153 − 03 (Reapproved 2010) E1153 − 14
Standard Test Method for
Efficacy of Sanitizers Recommended for Inanimate
1
Inanimate, Hard, Nonporous Non-Food Contact Surfaces
This standard is issued under the fixed designation E1153; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—A warning note was moved into the text editorially in May 2010.
1. Scope
1.1 This test method is used to evaluate the antimicrobial efficacy of sanitizers on precleaned, inanimate, hard, nonporous,
non-food contact surfaces.surfaces against Staphylococcus aureus, or Klebsiella pneumoniae or Enterobacter aerogenes, or a
combination thereof. Appropriate modifications to the method may be required when testing organisms not specified herein. When
utilizing test surfaces not described herein (see Test Method E2274) or when evaluating spray-based or towelette-based
antimicrobial products, modifications may also be required.
1.2 This test method may also be used to evaluate the antimicrobial efficacy of one-step cleaner/sanitizercleaner-sanitizer
formulations recommended for use on lightly soiled, inanimate, nonporous, non-food contact surfaces.
1.3 It is the responsibility of the investigator to determine whether Good Laboratory Practices (GLP) isare required and to
follow them where appropriate (see section 40 CFR, 160)160 or as revised.revised.)
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard may involve hazardous materials, chemicals and microorganisms and should be performed only by persons
who have had formal microbiological training.This standard does not purport to address all of the safety concerns, if any,
associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and
determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D1193 Specification for Reagent Water
E1054 Test Methods for Evaluation of Inactivators of Antimicrobial Agents
E2274 Test Method for Evaluation of Laundry Sanitizers and Disinfectants
E2756 Terminology Relating to Antimicrobial and Antiviral Agents
2.2 Federal Standard:
3
40 CFR, Part 160, Good Laboratory Practice Standards
3. Terminology
3.1 Terms used in this test method are defined in Terminology E2756.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 accuracy, n—a measure of the degree of conformity of a value generated by a specific procedure to the assumed or
accepted true value, and includes both precision and bias.
3.2.2 ambient temperature, n—temperature of the environment in which a test method is performed.
3.2.3 antimicrobial, adj—describes an agent that kills or inactivates microorganisms or suppresses their growth or reproduction.
1
This test method is under the jurisdiction of ASTM Committee E35 on Pesticides, Antimicrobials, and Alternative Control Agents and is the direct responsibility of
Subcommittee E35.15 on Antimicrobial Agents.
Current edition approved April 1, 2010April 1, 2014. Published May 2010May 2014. Originally approved 1987. Last previous edition approved in 20032010 as
ε1
E1153 – 03.E1153 – 03(2010) . DOI: 10.1520/E1153-03R10.10.1520/E1153-14.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E1153 − 14
3.2.4 bias, n—a systematic error that contributes to the difference between the mean of a large number of test results and an
accepted reference value.
3.2.5 cleaner-sanitizer, n—a physical or chemical agent that removes soil from an object and reduces numbers of
microorganisms on non-food contact surfaces.
3.2.6 carrier, n—a surrogate surface or matrix that facilitates the interaction of test microorganisms and treatment(s).
3.2.7 effıcacy, n—the proven performance of a product esta
...