Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners

SCOPE
1.1 This specification covers the acceptable details and tolerances for the plenum chamber used in specified air performance measurement tests for vacuum cleaners.  
1.2 The plenum chamber is designed for vacuum measurements only.  
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

General Information

Status
Historical
Publication Date
09-Oct-1998
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F431-98 - Standard Specification for Air Performance Measurement Plenum Chamber for Vacuum Cleaners
English language
10 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
An American National Standard
Designation: F 431 – 98
Standard Specification for
Air Performance Measurement Plenum Chamber for Vacuum
1
Cleaners
This standard is issued under the fixed designation F 431; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
3
1. Scope Orifice Plate Holder Details (F 431)
1.1 This specification covers the acceptable details and
3. Details
tolerances for the plenum chamber used in specified air
3.1 Plenum chambers conforming to this specification shall
performance measurement tests for vacuum cleaners.
be fabricated in accordance with the dimensions, tolerances,
1.2 The plenum chamber is designed for vacuum measure-
and notes shown in the following figures:
ments only.
3.1.1 Plenum chamber assembly, see Fig. 1.
1.3 The foot-pound, inch system of units is used in this
3.1.2 Orifice plate detail, see Fig. 2.
standard. The values in parentheses are given for information
3.1.3 Orifice plate holder and assembly, see Fig. 3.
only.
3.2 Manometer connection detail, see Fig. 1(f), Note 17.
2. Referenced Documents
4. Orifice Plates
2.1 ASTM Standards:
4.1 Orifice plates conforming to this specification shall be
F 558 Test Method for Measuring Air Performance Charac-
2 fabricated in accordance to the dimensions, tolerances, and
teristics of Vacuum Cleaners
notes shown in the following figure:
F 820 Test Method for Measuring Air Performance Charac-
2 4.1.1 Orifice plate dimensional detail, see Fig. 2(a).
teristics of Central Vacuum Cleaning Systems
4.1.2 Acceptable machined edges for orifice plates, see Fig.
2.2 ASTM Adjunct:
2(b).
5. Keywords
1
5.1 air performance; orifice plate; plenum chamber; vacuum
This specification is under the jurisdiction of ASTM Committee F-11 on
Vacuum Cleaners and is the direct responsibility of Subcommittee F11.22 on Air
cleaner
Performance.
Current edition approved Oct. 10, 1998. Published February 1999. Originally
e1
published as F 431 – 75. Last previous edition F 431 – 87 (1992) .
2 3
Annual Book of ASTM Standards, Vol 15.07. Available from ASTM Headquarters. Order PCN 12-604310-47.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 431
FIG. 1 (a) Plenum Chamber (Material: see Note 8)
FIG. 1 (b) Hose Connector Plate (Material: 0.250-in. (6.35-mm) Steel) (continued)
2

---------------------- Page: 2 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 431
FIG. 1 (c) Hose Connector (Material: Aluminum or Steel—see Note 16) (continued)
FIG. 1 (d) Flange Plate (Material: 0.250-in. (6.35-mm) Steel) (continued)
3

---------------------- Page: 3 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 431
FIG. 1 (e) Cleaner Plate (Material: 0.250-in. (6.35-mm) Steel) (continued)
4

---------------------- Page: 4 ----------------------
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
F 431
NOTE 1—All dimensions are measured from inside surfaces.
NOTE 2—Interior must be clean, smooth, and free of projections or recesses on walls or attachment openings. Internal bracing should not be used to
support plenum chamber walls.
NOTE 3—Attachment port edge to be smooth and well rounded.
NOTE 4—Orifice box must withstand 180 in. of water (336 mm Hg) negative static pressure without significant distortion of walls or joints after
chamber is completely fabricated and attachment made.
NOTE 5—All joints and connections must be airtight.
NOTE 6—Tolerances (unless otherwise specified): one-place decimal 60.031 in. (0.080 mm); two-place decimal 60.01 in. (0.25 mm); three-place
decimal 60.005 in. (0.13 mm).
NOTE 7—Flange plate and manometer connection to be welded to chamber completely around the sides.
NOTE 8—Plenum chamber minimum material specification 0.187 in. (4.75 mm) thick low carbon steel.