ASTM D6221-00(2006)
(Specification)Standard Specification for Reinforced Bituminous Flashing Sheets for Roofing and Waterproofing
Standard Specification for Reinforced Bituminous Flashing Sheets for Roofing and Waterproofing
ABSTRACT
This specification covers two types of factory prepared reinforced bituminous flashing sheets used for roofing and waterproofing systems. The bitumen used may be asphalt, coal-tar pitch, or polymer modified bitumen. The reinforcement may include any one or a combination of organic (wood fiber), polyester, or glass fiber felts, woven fabrics, or thermoplastic films. Fine mineral powders, granules, or metal foils may be used as surfacing. Specimens shall be sampled, be tested for, and consequently conform to dimensional and physical properties, as follows: mass; thickness; load-strain properties; impact resistance; tear strength and resistance; flexibility; breaking load; and elongation at break. Calculation procedures for the mean, estimated standard deviation, and mean variance of test values from specimens tested before and after heat conditioning are also detailed.
SCOPE
1.1 This specification covers factory prepared reinforced bituminous sheet used in flashing. The bitumen used may be asphalt, coal-tar pitch, or polymer modified bitumen. The reinforcement may include any one or a combination of organic (wood fiber), polyester, or glass fiber felts, woven fabrics, or thermoplastic films. Fine mineral powders, granules, or metal foils may be used as surfacing.
1.2 The values stated in SI units are to be regarded as standard. The inch-pound units shown in parentheses are for information only.
The following precautionary statement pertains only to the test method portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D6221 −00(Reapproved 2006)
Standard Specification for
Reinforced Bituminous Flashing Sheets for Roofing and
Waterproofing
This standard is issued under the fixed designation D6221; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Waterproofing Materials and Membranes (Withdrawn
2002)
1.1 This specification covers factory prepared reinforced
D5683Test Method for Flexibility of Roofing and Water-
bituminous sheet used in flashing. The bitumen used may be
proofing Materials and Membranes
asphalt, coal-tar pitch, or polymer modified bitumen. The
D5869Practice for Dark Oven Heat Exposure of Roofing
reinforcement may include any one or a combination of
and Waterproofing Materials
organic (wood fiber), polyester, or glass fiber felts, woven
fabrics,orthermoplasticfilms.Finemineralpowders,granules,
3. Terminology
or metal foils may be used as surfacing.
3.1 Definitions:
1.2 The values stated in SI units are to be regarded as
3.1.1 See Terminology D1079 for terms relating to roofing
standard. The inch-pound units shown in parentheses are for
or waterproofing.
information only.
4. Classification
1.3 The following precautionary statement pertains only to
the test method portion, Section 7, of this specification:This
4.1 Type 1—Heavy, thick flashing sheets.
standard does not purport to address all of the safety concerns,
4.2 Type 2—Light weight, thin flashing sheets
if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health
5. Significance and Use
practices and determine the applicability of regulatory limita-
5.1 The criteria listed in this specification are based on
tions prior to use.
round robin testing of materials that, if correctly installed, can
be used as the primary material for flashing membranes. The
2. Referenced Documents
manufacturer’sinstallationrecommendationsmustbefollowed
2.1 ASTM Standards: in every case.
D228Test Methods for Sampling, Testing, and Analysis of
5.2 Compliance with the criteria in this specification is
Asphalt Roll Roofing, Cap Sheets, and Shingles Used in
believed to be necessary for satisfactory performance, but the
Roofing and Waterproofing
linkage has not been established between performance and
D751Test Methods for Coated Fabrics
these criteria.
D1079Terminology Relating to Roofing and Waterproofing
D2523Practice for Testing Load-Strain Properties of Roof-
6. Physical Properties
ing Membranes
6.1 Conform to criteria in Table 1.
D3746Test Method for Impact Resistance of Bituminous
6.2 Themeanmass,thickness,loadatbreak,andelongation
Roofing Systems
at break shall not change more than 10% from the expected
D5601Test Method for Tearing Resistance of Roofing and
variance after heat conditioning.
7. Sampling and Test Methods
This specification is under the jurisdiction of ASTM Committee D08 on
7.1 Comply with Test Methods D228 for sampling.
Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.04
on Felts, Fabrics and Bituminous Sheet Materials.
7.2 Use the following test methods to test the samples:
Current edition approved Dec. 1, 2006. Published December 2006. Originally
7.2.1 Mass—See Test Methods D228.
approved in 1998. Last previous edition approved in 2000 as D6221–00. DOI:
7.2.2 Thickness—See Test Methods D751.
10.1520/D6221-00R06.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on The last approved version of this historical standard is referenced on
the ASTM website. www.astm.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
D6221−00 (2006)
TABLE 1 Physical Properties
n and n = the number of specimens tested.
b a
Property Type 1 Type 2
8.1.5 Look up the percentile of the t distribution for the
2 2
Mass, kg/m (lb/100 ft ), min 3.4 (70) 1.7 (35)
degrees of freedom calculated in Table 2.
Thickness, mm (in.), min 3.3 (0.130) 0.6 (0.025)
Breaking load, k N/m (lbf/in.), minimum at 73.4°F 9.6 (55) 9.6 (55)
8.1.6 Calculate the expected variance “ u” between the
Elongation at break, min
...
Questions, Comments and Discussion