SCOPE
1.1 This guide covers the minimum installation recommendations for fully adhered, hot-applied reinforced waterproofing systems on vertical and low-slope (plaza deck) surfaces.
1.2 For the purpose of this guide, the substrate is assumed to be concrete or masonry, structurally sound, able to accept the weight of anticipated loads, and meets the local building code requirements. Similarly, all components of the waterproofing system are assumed to comply with any federal, state, and local environmental regulations that may be in effect at the time of installation. Expansion joints, insulation, drainage layers, and overburden are beyond the scope of this guide.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6622 – 01
Standard Guide for
Application of Fully Adhered Hot-Applied Reinforced
Waterproofing Systems
This standard is issued under the fixed designation D 6622; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D 450 Specification for Coal-Tar Pitch Used in Roofing,
Dampproofing, and Waterproofing
1.1 This guide covers the minimum installation recommen-
D 1079 Terminology Relating to Roofing, Waterproofing,
dations for fully adhered, hot-applied reinforced waterproofing
and Bituminous Materials
systems on vertical and low-slope (plaza deck) surfaces.
D 1327 Specification for Bitumen-Saturated Woven Burlap
1.2 Forthepurposeofthisguide,thesubstrateisassumedto
Fabrics Used in Roofing and Waterproofing
be concrete or masonry, structurally sound, able to accept the
D 1668 Specification for Glass Fabrics (Woven and
weight of anticipated loads, and meets the local building code
Treated) for Roofing and Waterproofing
requirements. Similarly, all components of the waterproofing
D 2178 Specification for Asphalt Glass Felt Used in Roof-
systemareassumedtocomplywithanyfederal,state,andlocal
ing and Waterproofing
environmental regulations that may be in effect at the time of
D 2822 Specification for Asphalt Roof Cement
installation. Expansion joints, insulation, drainage layers, and
D 4022 Specification for Coal Tar Roof Cement, Asbestos
overburden are beyond the scope of this guide.
Containing
1.3 The values stated in SI units are to be regarded as the
D 4586 Specification for Asphalt Roof Cement, Asbestos-
standard. The values given in parentheses are for information
Free
only.
D 4990 Specification for Coal Tar Glass Felt Used in
1.4 This standard does not purport to address all of the
Roofing and Waterproofing
safety concerns, if any, associated with its use. It is the
D 5295 Guide for Preparation of Concrete Surfaces for
responsibility of the user of this standard to establish appro-
Adhered (Bonded) Membrane Waterproofing Systems
priate safety and health practices and determine the applica-
D 5643 Specification for Coal Tar Roof Cement, Asbestos
bility of regulatory requirements prior to use.
Free
2. Referenced Documents D 5726 Specification for Thermoplastic Fabrics Used in
Hot-Applied Roofing and Waterproofing
2.1 ASTM Standards:
D 5898 Guide for Standard Details for Adhered Sheet
C 981 Guide for Design of Built-Up Bituminous Membrane
Waterproofing
Waterproofing Systems for Building Decks
D 5957 Guide for Flood Testing Horizontal Waterproofing
D 41 Specification for Asphalt Primer Used in Roofing,
Installations
Dampproofing, and Waterproofing
D 6152 Specification for SEBS-Modiifed Mopping Asphalt
D 43 Specification for Coal Tar Primer Used in Roofing,
Used in Roofing
Dampproofing, and Waterproofing
D 6162 Specification for Styrene Butadiene Styrene (SBS)
D 173 Specification for Bitumen-Saturated Cotton Fabrics
Modified Bituminous Sheet Materials Using a Combina-
Used in Roofing and Waterproofing
tion of Polyester and Glass Fiber Reinforcement
D 226 Specification for Asphalt-Saturated Organic Felt
D 6163 Specification for Styrene Butadiene Styrene (SBS)
Used in Roofing and Waterproofing
Modified Bituminous Sheet Materials Using Glass Fiber
D 227 Specification for Coal-Tar-Saturated Organic Felt
Reinforcements
Used in Roofing and Waterproofing
D 6164 Specification for Styrene Butadiene Styrene (SBS)
D 449 Specification forAsphalt Used in Dampproofing and
Modified Bituminous Sheet Materials Using Polyester
Waterproofing
Reinforcements
D 6451 Guide for Application of Asphalt-Based Protection
This guide is under the jurisdiction of ASTM Committee D08 on Roofing, 3
Board
Waterproofing, and Bituminous Materials and is the direct responsibility of
Subcommittee D08.22 on Waterproofing and Dampproofing Systems.
Current edition approved Jan. 10, 2001. Published March 2001.
Annual Book of ASTM Standards, Vol 04.07.
Annual Book of ASTM Standards, Vol 04.04.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
D 6622
D 6506 Specification for Asphalt-Based Protection Board 7.2 Store materials to prevent system supplier’s markings
for Below-Grade Waterproofing from being destroyed.
2.2 Other Documents: 7.3 When used as part of the system, store primer and
CAN/CGSB-37.50 Hot-Applied, Rubberized Asphalt for mastic in tightly closed original containers at temperatures
Roofing and Waterproofing recommended by the system supplier.
CAN/CGSB-37.51 Application for Hot-Applied Rubber-
ized Asphalt for Roofing and Waterproofing 8. Safety Precautions
8.1 Safety precautions include, but are not limited to: wear
3. Terminology
protective clothing, vent fumes especially in confined spaces,
3.1 Definitions—For definitions of terms used in this guide,
avoidcontactwithhotbitumen,donotuseflammablematerials
refer to Terminology D 1079.
near an open flame or near equipment that may produce sparks
or open flames. Obtain and refer to MSDSs for further safety
4. Classification
precautions.
4.1 The following types are used to identify the waterproof-
ing systems included in this guide.
9. Environmental Conditions
4.1.1 Type I—Membranes consisting of hot-applied coal tar
9.1 Installation can proceed when conditions agreed upon
pitch, and two or more layers of organic or inorganic felts or
by the owner, producer or system supplier, installer, and
fabrics.
specifier are met.
4.1.2 Type II—Membranes consisting of hot-applied as-
9.2 Conditions that may interfere with the installation and
phalt, and two or more layers of organic or inorganic felts or
performance of the waterproofing include: inclement weather,
fabrics.
wet or frost-covered surfaces, dirty or dusty surfaces, high
4.1.3 Type III—Membranes consisting of hot-applied as-
winds, and temperatures above or below a workable range for
phalt or polymer-modified asphalt, and one or more polymer-
the products to be installed.
modified bitumen sheets. The sheets are typically SBS-
modified bitumen and may be reinforced with fiberglass, or
10. Materials
polyester, or both.
10.1 Type I:
4.1.4 Type IV—Membranes consisting of hot-applied
10.1.1 Coal-tar primer: Specification D 43.
polymer-modified asphalt, and fabric reinforcement.
10.1.2 Coal-tar pitch: Specification D 450.
5. Significance and Use
10.1.3 Felts: Specification D 227 or D 4990.
10.1.4 Coal-tar-treated glass fabric: Specification D 1668,
5.1 This guide outlines general procedures and precautions
Type II.
for the application of fully adhered hot-applied built-up rein-
10.1.5 Coal-tar-saturated cotton fabric: Specification D 173.
forced waterproofing systems.
10.1.6 Coal-tar-saturated burlap fabric: Specification
5.2 This guide is not all inclusive and is intended only to
D 1327.
supplement detailed instructions from designers, and the rec-
10.1.7 Coal-tar flashing cement: Specification D 4022 or
ommendations of manufacturers. Manufacturers of some of the
D 5643.
systems addressed by this guide require proprietary products
10.1.8 Protection board: Specification D 6506.
and special procedures not described in this guide. Manufac-
10.2 Type II:
turers’ recommendations should therefore be considered in the
10.2.1 Asphalt primer: Specification D 41.
application of this guide.
10.2.2 Asphalt: Specification D 449.
5.3 For design guidelines, consult Guide C 981.
10.2.3 Felts: Specification D 226 or D 2178.
6. Delivery of Materials
10.2.4 Bitumen-saturated cotton fabric: Specifi
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.