ASTM C1021-08(2014)
(Practice)Standard Practice for Laboratories Engaged in Testing of Building Sealants
Standard Practice for Laboratories Engaged in Testing of Building Sealants
SIGNIFICANCE AND USE
4.1 Importance of Prequalification—For required accuracy of test results and reliability of certification, it is essential that testing laboratories be prequalified. This practice establishes those qualifications.
4.2 Contractual Relationships:
4.2.1 Although testing laboratories may be qualified in accordance with this practice, it is important for the contracting authority to consider the relationship of the testing laboratory with other interested parties before engaging the laboratory to perform the testing. The other interested parties in the project usually consist of the manufacturer of the material to be tested, the contractor (bidder), the owner of the project (user and contracting authority), and the architect who serves as the owner's agent in preparing the contract documents.
4.2.2 Many sealant manufacturers have their own qualified testing facilities that are used to conduct research and maintain quality control of their products. Generally, the companies that have such facilities are willing to certify as to the performance standards with which their products comply. The contracting authority should determine if there are conflicting interests in such a relationship. The contracting authority may prefer that the product testing to ascertain conformance with specific performance standards and the reporting of such testing be performed by a qualified but independent testing laboratory. The contract documents should make this requirement known so that bidders can bid accordingly.
4.2.3 The testing of each caulking and sealant for each and every project can be costly. On a small building project, the cost of testing, if required, may be more than the cost of the sealant materials. On a large project, on the other hand, the cost of testing a sealant with accompanying certification by a qualified independent testing laboratory may be small in comparison to the sealant materials and commensurate with the assurances desired by the contracting autho...
SCOPE
1.1 This practice describes the qualifications, including minimum requirements for personnel and equipment, duties, responsibilities, and services of independent commercial materials testing laboratories engaged in the testing of caulking and sealants used in building construction.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3 The subcommittee with jurisdiction of this standard is not aware of any similar or equivalent ISO standard.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1021 − 08 (Reapproved 2014)
Standard Practice for
Laboratories Engaged in Testing of Building Sealants
This standard is issued under the fixed designation C1021; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C719 Test Method for Adhesion and Cohesion of Elasto-
meric Joint Sealants Under Cyclic Movement (Hockman
1.1 This practice describes the qualifications, including
Cycle)
minimum requirements for personnel and equipment, duties,
C731 Test Method for Extrudability, After Package Aging,
responsibilities, and services of independent commercial ma-
of Latex Sealants
terials testing laboratories engaged in the testing of caulking
C732 Test Method forAging Effects ofArtificialWeathering
and sealants used in building construction.
on Latex Sealants
1.2 This standard does not purport to address all of the
C734 Test Method for Low-Temperature Flexibility of Latex
safety concerns, if any, associated with its use. It is the
Sealants After Artificial Weathering
responsibility of the user of this standard to establish appro-
C736 Test Method for Extension-Recovery andAdhesion of
priate safety and health practices and determine the applica-
Latex Sealants
bility of regulatory limitations prior to use.
C792 TestMethodforEffectsofHeatAgingonWeightLoss,
1.3 The subcommittee with jurisdiction of this standard is
Cracking, and Chalking of Elastomeric Sealants
not aware of any similar or equivalent ISO standard.
C793 Test Method for Effects of Laboratory Accelerated
2. Referenced Documents
Weathering on Elastomeric Joint Sealants
C794 TestMethodforAdhesion-in-PeelofElastomericJoint
2.1 ASTM Standards:
Sealants
C510 Test Method for Staining and Color Change of Single-
C834 Specification for Latex Sealants
or Multicomponent Joint Sealants
C910 Test Method for Bond and Cohesion of One-Part
C603 Test Method for Extrusion Rate and Application Life
of Elastomeric Sealants Elastomeric Solvent Release-Type Sealants
C920 Specification for Elastomeric Joint Sealants
C639 Test Method for Rheological (Flow) Properties of
Elastomeric Sealants C961 Test Method for Lap Shear Strength of Sealants
C661 Test Method for Indentation Hardness of Elastomeric- C1087 Test Method for Determining Compatibility of
Type Sealants by Means of a Durometer
Liquid-Applied Sealants with Accessories Used in Struc-
C679 Test Method for Tack-Free Time of Elastomeric Seal-
tural Glazing Systems
ants
C1135 Test Method for Determining TensileAdhesion Prop-
C681 Test Method for Volatility of Oil- and Resin-Based,
erties of Structural Sealants
Knife-Grade, Channel Glazing Compounds
C1183 Test Method for Extrusion Rate of Elastomeric Seal-
C711 Test Method for Low-Temperature Flexibility and
ants
Tenacity of One-Part, Elastomeric, Solvent-Release Type
C1184 Specification for Structural Silicone Sealants
Sealants
C1216 Test Method forAdhesion and Cohesion of One-Part
C712 Test Method for Bubbling of One-Part, Elastomeric,
Elastomeric Solvent Release Sealants
Solvent-Release Type Sealants
C1241 Test Method for Volume Shrinkage of Latex Sealants
C717 Terminology of Building Seals and Sealants
During Cure
C1246 Test Method for Effects of Heat Aging on Weight
Loss, Cracking, and Chalking of Elastomeric Sealants
This practice is under the jurisdiction of ASTM Committee C24 on Building
Seals and Sealants and is the direct responsibility of Subcommittee C24.10 on
After Cure
Specifications, Guides and Practices.
C1247 Test Method for Durability of Sealants Exposed to
Current edition approved Jan. 1, 2014. Published January 2014. Originally
Continuous Immersion in Liquids
approved in 1984. Last previous edition approved in 2008 as C1021 – 08. DOI:
10.1520/C1021-08R14.
C1248 TestMethodforStainingofPorousSubstratebyJoint
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Sealants
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
C1257 Test Method for Accelerated Weathering of Solvent-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. Release-Type Sealants
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
C1021 − 08 (2014)
C1265 Test Method for Determining the Tensile Properties 4.2 Contractual Relationships:
of an Insulating Glass Edge Seal for Structural Glazing
4.2.1 Although testing laboratories may be qualified in
Applications
accordancewiththispractice,itisimportantforthecontracting
C1294 Test Method for Compatibility of Insulating Glass
authority to consider the relationship of the testing laboratory
Edge Sealants with Liquid-Applied Glazing Materials
with other interested parties before engaging the laboratory to
C1311 Specification for Solvent Release Sealants
perform the testing. The other interested parties in the project
C1367 Test Method for Dead Load Resistance of a Sealant
usually consist of the manufacturer of the material to be tested,
in Elevated Temperatures
the contractor (bidder), the owner of the project (user and
C1382 Test Method for DeterminingTensileAdhesion Prop-
contracting authority), and the architect who serves as the
erties of Sealants When Used in Exterior Insulation and
owner’s agent in preparing the contract documents.
Finish Systems (EIFS) Joints
4.2.2 Many sealant manufacturers have their own qualified
C1442 Practice for Conducting Tests on Sealants Using
testing facilities that are used to conduct research and maintain
Artificial Weathering Apparatus
quality control of their products. Generally, the companies that
C1501 Test Method for Color Stability of Building Con-
have such facilities are willing to certify as to the performance
struction Sealants as Determined by Laboratory Acceler-
standards with which their products comply. The contracting
ated Weathering Procedures
authority should determine if there are conflicting interests in
C1519 Test Method for Evaluating Durability of Building
such a relationship. The contracting authority may prefer that
Construction Sealants by Laboratory Accelerated Weath-
the product testing to ascertain conformance with specific
ering Procedures
performance standards and the reporting of such testing be
C1589 Practice for Outdoor Weathering of Construction
performed by a qualified but independent testing laboratory.
Seals and Sealants
The contract documents should make this requirement known
C1635 Test Method to Evaluate Adhesion/Cohesion Proper-
so that bidders can bid accordingly.
ties of a Sealant at Fixed Extension
4.2.3 The testing of each caulking and sealant for each and
D2202 Test Method for Slump of Sealants
every project can be costly. On a small building project, the
D2203 Test Method for Staining from Sealants
cost of testing, if required, may be more than the cost of the
D2377 Test Method for Tack-
...







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.