Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material

SCOPE
1.1 These test methods cover procedures for sampling and testing prefabricated, reinforced, polymer-modified bituminous sheet materials designed for single- or multiple-ply application in roofing and waterproofing membranes. These products may use various surfacing materials on one side.
1.2 These test methods appear in the following order:
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
14-Jan-2007
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D5147-07 - Standard Test Methods for Sampling and Testing Modified Bituminous Sheet Material
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 5147 – 07
Standard Test Methods for
1
Sampling and Testing Modified Bituminous Sheet Material
This standard is issued under the fixed designation D5147; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope D95 Test Method for Water in Petroleum Products and
Bituminous Materials by Distillation
1.1 These test methods cover procedures for sampling and
D146 Test Methods for Sampling and Testing Bitumen-
testingprefabricated,reinforced,polymer-modifiedbituminous
Saturated Felts and Woven Fabrics for Roofing and Wa-
sheet materials designed for single- or multiple-ply application
terproofing
in roofing and waterproofing membranes. These products may
D1204 Test Method for Linear Dimensional Changes of
use various surfacing materials on one side.
Nonrigid Thermoplastic Sheeting or Film at Elevated
1.2 These test methods appear in the following order:
Temperature
Section
D4073 Test Method for Tensile-Tear Strength of Bitumi-
Sampling 3
nous Roofing Membranes
Conditioning 4
D4798 Practice for Accelerated Weathering Test Condi-
Thickness 5
tions and Procedures for Bituminous Materials (Xenon-
Load Strain Properties 6
Tear Strength 7
Arc Method)
Moisture Content 8
D4977 Test Method for Granule Adhesion to Mineral
Water Absorption 9
Dimensional Stability 10 Surfaced Roofing by Abrasion
Low-Temperature Flexibility 11
D5636 TestMethodforLowTemperatureUnrollingofFelt
Heat Conditioning 12
or Sheet Roofing and Waterproofing Materials
Accelerated Weathering 13
D5869 Practice for Dark Oven Heat Exposure of Bitumi-
Granule Embedment 14
Compound Stability 15
nous Materials
Coating Thickness 16
E177 Practice for Use of the Terms Precision and Bias in
Low Temperature Unrolling 17
Precision and Bias 18 ASTM Test Methods
E691 Practice for Conducting an Interlaboratory Study to
1.3 The values stated in SI units are to be regarded as the
Determine the Precision of a Test Method
standard. The values given in parentheses are for information
only.
3. Sampling
1.4 This standard does not purport to address all of the
3.1 Fromeachshipmentorfractionthereof,selectatrandom
safety concerns, if any, associated with its use. It is the
a number of rolls equal to one half the cube root of the total
responsibility of the user of this standard to establish appro-
numberofrollsinthelot.Ifthecalculatednumberisfractional,
priate safety and health practices and determine the applica-
express it as the next highest whole number. For convenience,
bility of regulatory limitations prior to use.
atableshowingthenumberofrollstobeselectedfromthelots
ofvarioussizesisgiveninTestMethodD146.Whenmutually
2. Referenced Documents
agreed upon by the concerned parties, other sampling frequen-
2
2.1 ASTM Standards:
cies may be used and reported within the framework of these
procedures. The minimum sample shall consist of five rolls.
The rolls so selected constitute the representative sample used
1
These test methods are under the jurisdiction of ASTM Committee D08 on
forallsubsequentobservationsandtestspertainingtothelotof
Roofing and Waterproofing and are the direct responsibility of Subcommittee
material being examined.
D08.04 on Felts and Fabrics.
Current edition approved Jan. 15, 2007. Published February 2007. Originally
4. Conditioning
approved in 1991. Last previous edition approved in 2006 as D5147–06.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
4.1 Unless otherwise specified, condition test specimens for
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
a minimum of4hat23 6 2°C (73.4 6 3.6°F) and 50 65%
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. relative humidity before testing.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D5147–07
5. Thickness 5.2.2 Takefivemeasurementsoftheselvagethicknessalong
a line parallel to machine direction. The measurements are to
5.1 The thickness measuring device shall be a micrometer
be taken midway between the surfacing edge and the sheet
of the dial or digital-electronic type capable of measuring
edge or, in the case of smooth products, midway between the
dimensions to an accuracy of 0.1 mm (0.004 in.). The mi-
laying line and the sheet edge, and spaced 150 6 15 mm (6 6
crometer shall be equipped with a flat, circular presser foot
0.5 in.) apart. Refer to Fig. 1 for an illustration of the selvage
with a diameter greater or equal to 9.5 mm (0.375 in.) and less
thickness measurement loca
...