Standard Test Method for Measuring Maximum Function Volume of the Primary Dirt<brk/> Receptacle in a Vacuum Cleaner

SIGNIFICANCE AND USE
3.1 This test method covers a procedure to determine the maximum functional volume of the primary dirt receptacle when installed in the vacuum cleaner.  
3.2 This test method provides the maximum amount of test media that the primary dirt receptacle will hold and may be more than the volume obtained when filled to the manufacturer's recommended fill line.
SCOPE
1.1 This test method covers household types of upright, canister, and combination vacuum cleaners.  
1.2 This test method provides a measurement in dry quarts or litres of the maximum functional volume of the primary dirt receptacle when installed in the vacuum cleaner.  
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazards statements see 7.2 and 8.5.    
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
30-Sep-2018
Technical Committee
Drafting Committee
Current Stage
Ref Project

Buy Standard

Standard
ASTM F888-06(2018) - Standard Test Method for Measuring Maximum Function Volume of the Primary Dirt<brk/> Receptacle in a Vacuum Cleaner
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F888 − 06 (Reapproved 2018)
Standard Test Method for
Measuring Maximum Function Volume of the Primary Dirt
1
Receptacle in a Vacuum Cleaner
ThisstandardisissuedunderthefixeddesignationF888;thenumberimmediatelyfollowingthedesignationindicatestheyearoforiginal
adoptionor,inthecaseofrevision,theyearoflastrevision.Anumberinparenthesesindicatestheyearoflastreapproval.Asuperscript
epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4.2 VoltageRegulatorSystem,tocontroltheinputvoltageto
the vacuum cleaner. The regulator system shall be capable of
1.1 This test method covers household types of upright,
maintaining the vacuum cleaners rated voltage of 61% and
canister, and combination vacuum cleaners.
rated frequency 61 Hz having a wave form that is essentially
1.2 This test method provides a measurement in dry quarts
sinusoidal with 3% maximum harmonic distortion for the
or litres of the maximum functional volume of the primary dirt
duration of the test.
receptacle when installed in the vacuum cleaner.
4.3 Temperature Measuring Equipment, to provide mea-
1.3 This standard does not purport to address all of the
surements accurate to within 61°F (0.5°C).
safety concerns, if any, associated with its use. It is the
4.4 Humidity Measuring Equipment, to provide measure-
responsibility of the user of this standard to establish appro-
ments accurate to within 62% relative humidity.
priate safety, health, and environmental practices and deter-
mine the applicability of regulatory limitations prior to use.
4.5 Adapter, to be attached to the cleaning nozzle of upright
For specific hazards statements see 7.2 and 8.5.
cleaners for use in directing granulated cork into the nozzle.
1.4 This international standard was developed in accor-
See Fig. 1.
dance with internationally recognized principles on standard-
4.6 Volume Measuring Container, to measure volume of
ization established in the Decision on Principles for the
granulated cork. This shall have a capacity of one dry quart.
Development of International Standards, Guides and Recom-
See Fig. 2.The container shall be made of transparent material
mendations issued by the World Trade Organization Technical
to ensure no voids when filled with granulated cork. As an
Barriers to Trade (TBT) Committee.
option, a 1-L container can be used.
2. Referenced Documents
4.7 WeighingScale—Thescaleshallbeaccurateto0.035oz
2
(1 g) and have a weighing capacity of at least 15 lb (6.82 kg).
2.1 SAE Standard:
SAE J726bAir Cleaner Test Code
5. Materials
3. Significance and Use
5.1 New Granulated Cork—Premium Grade 2 mm to 4 mm
3
3.1 This test method covers a procedure to determine the
size.
maximum functional volume of the primary dirt receptacle
5.2 Coarse-GradeAir Cleaner Test Dust,seeTable1.Asan
when installed in the vacuum cleaner.
option, talc may be used. See Table 2.
3.2 This test method provides the maximum amount of test
media that the primary dirt receptacle will hold and may be
6. Sampling
more than the volume obtained when filled to the manufactur-
6.1 Determination of Sample Size—A sample of sufficient
er’s recommended fill line.
sizeofeachmodelshallbetesteduntila90%confidencelevel
4. Apparatus is established within 65% of the mean value. A minimum of
three samples shall be tested. All samples shall be selected at
4.1 Voltmeter, to measure input voltage to the cleaner, to
random in accordance with good statistical practices.
provide measurements accurate to within 61%.
1
ThistestmethodisunderthejurisdictionofASTMCommitteeF11onVacuum
3
Cleaners and is the direct responsibility of Subcommittee F11.23 on Filtration. The sole source of supply of the test material known to the committee at this
Current edition approved Oct. 1, 2018. Published November 2018. Originally timeisJelinekCorkCorp.,4500WitmerIndustrialEstates,PMB167,NiagaraFalls,
approved in 2004. Last previous edition approved in 2011 as F888–06 (2011). NY 14305–1386. If you are aware of alternative suppliers, please provide this
DOI: 10.1520/F0888-06R18. information to ASTM International Headquarters. Your comments will receive
1
2
Available from Society of Automotive Engineers (SAE), 400 Commonwealth careful consideration at a meeting of the responsible technical committee, which
Dr., Warrendale, PA 15096-0001. you may attend.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F888 − 06 (2018)
FIG. 1 Adapter Plate for Uprights
FIG. 2 Volume Measuring Container
A
TABLE 1 Analysis of Coarse Grade Air Cleaner F11 Test Dust TABLE 2 Analysis of Unscented C
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.