ASTM D6162-00a
(Specification)Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber Reinforcements
SCOPE
1.1 This specification covers prefabricated modified bituminous sheet materials reinforced with a combination of polyester fabric and glass fiber, with or without granules, which use styrene butadiene styrene (SBS) thermoplastic elastomer as the primary modifier and are intended for use in the fabrication of multiple ply roofing and waterproofing membranes.
1.2 This specification is intended as a material specification only. Issues regarding the suitability of the specific roof constructions or application techniques are beyond this scope.
1.3 The specified tests and property limits used to characterize the sheet materials are intended to establish minimum properties. In-place roof system design criteria such as fire resistance, field strength, impact/puncture resistance, material compatibility, uplift resistance, and others, are factors beyond the scope of this material specification.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6162 – 00a
Standard Specification for
Styrene Butadiene Styrene (SBS) Modified Bituminous
Sheet Materials Using a Combination of Polyester and Glass
Fiber Reinforcements
This standard is issued under the fixed designation D6162; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Classifications
1.1 This specification covers prefabricated modified bitumi- 4.1 Modified bituminous sheet materials reinforced with a
noussheetmaterialsreinforcedwithacombinationofpolyester combination of polyester fabric and glass fiber reinforcement,
fabric and glass fiber, with or without granules, which use Type I, Type II and Type III are covered by this specification.
styrenebutadienestyrene(SBS)thermoplasticelastomerasthe 4.2 The following grades are used to describe the material
primary modifier and are intended for use in the fabrication of surfacing:
multiple ply roofing and waterproofing membranes. 4.2.1 Grade G—Granule surfaced.
1.2 This specification is intended as a material specification 4.2.2 Grade S—Smooth surfaced.
only. Issues regarding the suitability of the specific roof
5. Material and Manufacture
constructions or application techniques are beyond this scope.
5.1 In the process of manufacture, the reinforcement is
1.3 The specified tests and property limits used to charac-
terize the sheet materials are intended to establish minimum saturated with asphalt or modified asphalt and is impregnated
and coated on both sides with an SBS modified bituminous
properties. In-place roof system design criteria such as fire
resistance, field strength, impact/puncture resistance, material coating. The SBS modified bituminous coating shall be per-
mitted to be compounded with a mineral stabilizer.
compatibility, uplift resistance, and others, are factors beyond
the scope of this material specification. 5.2 The Grade G sheet is surfaced on the weather side with
mineralgranules,exceptforanyselvage.Topreventstickingin
1.4 The values stated in SI units are to be regarded as the
standard. The values given in parentheses are for information the roll, the reverse side and any selvage shall be permitted to
only. be covered with a mineral or any other surfacing that will not
interfere with adhesion or bonding of the lap during applica-
2. Referenced Documents
tion.
2.1 ASTM Standards: 5.3 Sheet material intended for application by heat welding
D1079 Terminology Relating to Roofing, Waterproofing, (torching)shallmeettheminimumbottomcoatingrequirement
and Bituminous Materials found in Table 1.
D5147 Test Methods for Sampling and Testing Modified
6. Physical Properties
Bituminous Sheet Materials Used in Roofing and Water-
6.1 The sheet shall conform to the minimum physical
proofing
properties prescribed in Table 2.
3. Terminology
6.2 The finished product shall not crack nor be so sticky as
3.1 Definitions— For definitions of terms used in this to cause tearing or other material damage upon being unrolled
specification, refer to Terminology D1079: at any product temperature between 4 and 60°C (40 and
3.1.1 elongation at 5 % of maximum load, n—the elonga- 140°F).
tion measured on the load-elongation curve at which point the
7. Dimensions, Mass, and Permissible Variations
load has dropped to 5% of its maximum value.
7.1 The finished product shall conform to the following
dimensions and variations:
This specification is under the jurisdiction of ASTM Committee D08 on
7.1.1 The width of the roll shall be as agreed between the
Roofing,Waterproofing,andBituminousMaterialsandisthedirectresponsibilityof
Subcommittee D08.04 on Felts and Fabrics. purchaser and the seller and shall not vary more than 1%.
Current edition approved June 10, 2000. Published August 2000. Originally
7.1.2 The area of the roll shall be no less than as agreed
published as D 6162–97. Last previous edition D 6162–00.
between the purchaser and the seller.
Annual Book of ASTM Standards, Vol 04.04.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
D 6162
TABLE 1 Dimensions and Masses of SBS Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber
Reinforcements
Description Type I Type II Type III
Thickness, min, mm (mils),
Grade S 1.8 (70) 2.0 (80) 2.0 (80)
Grade G 2.8 (110) 3.3 (130) 3.5 (135)
Net mass per unit area, min.,
2 2
g/m , (lbs/100 ft )
Grade S 2197 (45) 2441 (50) 2685 (55)
Grade G 2929 (60) 3661 (75) 4150 (85)
Bottom coating thickness, heat welding
application products, min, mm (mils)
Grade S 1.0 (40) 1.0 (40) 1.0 (40)
Grade G 1.0 (40) 1.0 (40) 1.0 (40)
TABLE 2 Physical Properties of SBS Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fiber
A
Reinforcements
Type I Type II Type III
Property
Grade: G and S Grade: G and S Grade: G and S
Maximum load at –18 6 2°C
(0 6 3.6°F), MD and XMD, min,
before and after heat conditioning,
kN/m (lbf/in.) 13.1 (75) 21.9 (125) 44 (250)
Elongation at −18 6 2°C
(0 6 3.6°F), MD and XMD, min,
at maximum load
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.