Standard Guide for the Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane on Vertical Surfaces

ABSTRACT
This guide describes the use of a high solids content, cold liquid-applied elastomeric waterproofing membrane subject to intermittent hydrostatic pressure in a waterproofing system intended for installation on cast-in-place concrete vertical surfaces. Typical uses for these systems include planters and foundation walls with drainage system and others. The major components to be considered for a below grade building wall waterproofing system are the structural wall or substrate to be waterproofed, waterproofing membrane, membrane protection, and drainage system. The following considerations are detailed: (1) compatibility; (2) continuity; (3) substrate: strength, density and moisture content, admixtures, release and curing agents, finish, dryness, and joints; (4) waterproofing membrane: adhesion to substrate, terminations, and penetrations; (5) treatment and design of reinforced, unreinforced, and expansion joints; (6) protection course: impact resistance, compatibility, ancillary provisions, thermal insulation, and drainage composites; and (7) drainage system: drainage course, backfill, and drainage pipes. Illustrations of footing, treatment of vertical corners, and pipe penetration for the waterproofing system and treatment of reinforced and unreinforced joints are given.
SCOPE
1.1 This guide describes the use of a high solids content, cold liquid-applied elastomeric waterproofing membrane that meets the performance criteria specified in Specification C836/C836M, subject to intermittent hydrostatic pressure in a waterproofing system intended for installation on vertical cast-in-place concrete surfaces.  
1.2 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.  
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Historical
Publication Date
30-Nov-2021
Current Stage
Ref Project

Buy Standard

Guide
ASTM C1471/C1471M-05(2021) - Standard Guide for the Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane on Vertical Surfaces
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview
Guide
REDLINE ASTM C1471/C1471M-05(2021) - Standard Guide for the Use of High Solids Content Cold Liquid-Applied Elastomeric Waterproofing Membrane on Vertical Surfaces
English language
6 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1471/C1471M −05 (Reapproved 2021)
Standard Guide for the
Use of High Solids Content Cold Liquid-Applied Elastomeric
1
Waterproofing Membrane on Vertical Surfaces
This standard is issued under the fixed designation C1471/C1471M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope C717 Terminology of Building Seals and Sealants
C836/C836M Specification for High Solids Content, Cold
1.1 This guide describes the use of a high solids content,
Liquid-Applied Elastomeric Waterproofing Membrane for
cold liquid-applied elastomeric waterproofing membrane that
Use with Separate Wearing Course
meets the performance criteria specified in Specification C836/
C898/C898M Guide for Use of High Solids Content, Cold
C836M, subject to intermittent hydrostatic pressure in a
Liquid-Applied Elastomeric Waterproofing Membrane
waterproofing system intended for installation on vertical
with Separate Wearing Course
cast-in-place concrete surfaces.
D4263 Test Method for Indicating Moisture in Concrete by
1.2 Thecommitteewithjurisdictionoverthisstandardisnot
the Plastic Sheet Method
aware of any comparable standards published by other orga-
3. Terminology
nizations.
3.1 Definitions—Refer to Terminology C717 for definitions
1.3 The values stated in either SI units or inch-pound units
of terms used in this standard.
are to be regarded separately as standard. The values stated in
each system may not be exact equivalents; therefore, each
3.2 Definitions of Terms Specific to This Standard:
system shall be used independently of the other. Combining
3.2.1 drainage composite—geocomposite consisting of a
values from the two systems may result in nonconformance
geotextile filter fabric and a drainage core of various thick-
with the standard.
nesses and shapes.
1.4 This standard does not purport to address all of the
4. Significance and Use
safety concerns, if any, associated with its use. It is the
4.1 This grade provides considerations for the design and
responsibility of the user of this standard to establish appro-
priate safety, health, and environmental practices and deter- installation of liquid-applied waterproofing systems.The intent
mine the applicability of regulatory limitations prior to use. is to provide information and guidelines for consideration by
1.5 This international standard was developed in accor- designers. Typical uses for these systems include, among
dance with internationally recognized principles on standard- others, planters and foundation walls with drainage systems.
ization established in the Decision on Principles for the
4.2 This guide is intended to be considered in conjunction
Development of International Standards, Guides and Recom-
with Guide C898/C898M to provide total system guidelines.
mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee. 5. Comparison to Other Standards
5.1 Thecommitteewithjurisdictionoverthisstandardisnot
2. Referenced Documents
aware of any comparable standards published by other orga-
2
2.1 ASTM Standards:
nizations.
C117 Test Method for Materials Finer than 75-µm (No. 200)
6. General
Sieve in Mineral Aggregates by Washing
6.1 General—The major components to be considered for a
below-grade building wall waterproofing system are the struc-
1
This guide is under the jurisdiction of ASTM Committee D08 on Roofing and
tural wall or substrate to be waterproofed, waterproofing
Waterproofing and is the direct responsibility of Subcommittee D08.22 on Water-
proofing and Dampproofing Systems.
membrane, membrane protection, drainage, and backfill. Ad-
Current edition approved Dec. 1, 2021. Published December 2021. Originally
ditional components to be considered are membrane
approved in 2000. Last previous edition approved in 2014 as C1471/C1471M – 05
ɛ1
terminations, penetrations, joints, and thermal insulation.
(2014) . DOI: 10.1520/C1471_C1471M-05R21.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
6.2 Compatibility—It is essential that all components and
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
contiguous elements be compatible, and that they be coordi-
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. nated to form an integrated waterproofing system.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1471/C1471M−05 (2021)
6.3 Continuity—It is essential that the waterproofing irregularities. A minimum width of 200 mm, with
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: C1471/C1471M − 05 (Reapproved 2014) C1471/C1471M − 05 (Reapproved
2021)
Standard Guide for the
the Use of High Solids Content Cold Liquid-Applied
1
Elastomeric Waterproofing Membrane on Vertical Surfaces
This standard is issued under the fixed designation C1471/C1471M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1
ε NOTE—Units information was editorially corrected in July 2014.
1. Scope
1.1 This guide describes the use of a high solids content, cold liquid-applied elastomeric waterproofing membrane that meets the
performance criteria specified in Specification C836C836/C836M, subject to intermittent hydrostatic pressure in a waterproofing
system intended for installation on vertical cast-in-place concrete surfaces.
1.2 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformancenonconformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine the
applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
2
2.1 ASTM Standards:
C117 Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
C717 Terminology of Building Seals and Sealants
C836C836/C836M Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use
with Separate Wearing Course
C898C898/C898M Guide for Use of High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane with
Separate Wearing Course
D4263 Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method
1
This guide is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.22 on Waterproofing
and Dampproofing Systems.
Current edition approved July 1, 2014Dec. 1, 2021. Published August 2014December 2021. Originally approved in 2000. Last previous edition approved in 20052014 as
ɛ1
C1471C1471/C1471M – 05 (2014) -05. DOI: 10.1520/C1471_C1471M-05R14E01.10.1520/C1471_C1471M-05R21.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1471/C1471M − 05 (2021)
3. Terminology
3.1 Definitions—Refer to Terminology C717 for definitions of terms used in this standard.
3.2 Definitions of Terms Specific to This Standard:
3.2.1 drainage composite—geocomposite consisting of a geotextile filter fabric and a drainage core of various thicknesses and
shapes.
4. Significance and Use
4.1 This grade provides considerations for the design and installation of liquid-applied waterproofing systems. The intent is to
provide information and guidelines for consideration by designers. Typical uses for these systems include, among others, planters
and foundation walls with drainage systems.
4.2 This guide is intended to be considered in conjunction with Guide C898C898/C898M to provide total system guidelines.
5. Comparison to Other Standards
5.1 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
6. General
6.1 General—The major components to be considered for a below grade below-grade building wall waterproofing s
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.