FprEN ISO 9300
(Main)Measurement of gas flow by means of critical flow nozzles (ISO/FDIS 9300:2022)
Measurement of gas flow by means of critical flow nozzles (ISO/FDIS 9300:2022)
This document specifies the geometry and method of use (installation in a system and operating conditions) of critical flow nozzles (CFNs) used to determine the mass flow rate of a gas flowing through a system basically without the need to calibrate the CFN. It also gives the information necessary for calculating the flow rate and its associated uncertainty.
This document is applicable to nozzles in which the gas flow accelerates to the critical velocity at the minimum flowing section, and only where there is steady flow of single-phase gas. When the critical velocity is attained in the nozzle, the mass flow rate of the gas flowing through the nozzle is the maximum possible for the existing inlet condition, while the CFN can only be used within specified limits, e.g. the CFN throat to inlet diameter ratio and Reynolds number. This document deals with the toroidal- and cylindrical-throat CFNs for which direct calibration experiments have been made in sufficient number to enable the resulting coefficients to be used with certain predictable limits of uncertainty.
Durchflussmessung von Gasen mit Venturidüsen bei kritischer Strömung (ISO/FDIS 9300:2022)
Dieses Dokument legt die geometrische Gestalt und die Betriebsweise (Einbau in ein System und Betriebsbedingungen) von Düsen bei kritischer Strömung (CFNs, en: critical flow nozzles) fest, die den Massendurchfluss eines durch ein System strömenden Gases bestimmen, ohne die CFN grundsätzlich zu kalibrieren. Es enthält außerdem die notwendigen Angaben für die Berechnung des Durchflusses und der zugehörigen Unsicherheit.
Dieses Dokument gilt für Düsen, in denen das Gas im kleinsten Strömungsquerschnitt auf die kritische Strömungsgeschwindigkeit beschleunigt wird und eine gleichbleibende Strömung nur für einphasiges Gas vorliegt. Bei Erreichen der kritischen Geschwindigkeit in der Düse hat der Massendurchfluss des durch die Düse strömenden Gases unter den auf der Einlaufseite vorhandenen Bedingungen sein Maximum, wobei die CFN nur innerhalb festgelegter Grenzen eingesetzt werden kann, z. B. das Verhältnis von Halsteil der CFN zum Durchmesser des Einlaufrohrs und Reynolds-Zahl. Dieses Dokument behandelt CFNs mit Toroid- und Zylinderhals, die in ausreichend häufigen Versuchen direkt kalibriert wurden, wodurch die sich draus ergebenden Koeffizienten mit vorhersagbaren Grenzwerten für die Unsicherheit angewendet werden können.
Mesure de débit de gaz au moyen de tuyères en régime critique (ISO/FDIS 9300:2022)
Le présent document spécifie la géométrie et le mode d’emploi (installation dans un circuit et conditions opératoires) de tuyères en régime critique (CFN) utilisées pour déterminer le débit-masse de gaz traversant le circuit sans besoins d'étalonner la CFN. Il donne également les informations nécessaires au calcul du débit et de l’incertitude associée.
Le présent document s’applique aux tuyères au sein desquelles l’écoulement gazeux est accéléré jusqu’à atteindre la vitesse critique à la section d’écoulement minimum et uniquement lorsqu’il existe un écoulement stationnaire monophasique de gaz. Lorsque la vitesse critique est atteinte dans la tuyère, le débit-masse du gaz traversant la tuyère est le plus grand débit-masse possible pour les conditions existant à l’entrée, tandis que les CFN peuvent être utilisées uniquement à l’intérieur des limites spécifiées, par exemple pour le rapport du diamètre au col au diamètre à l’entrée de la CFN et pour le nombre de Reynolds. Le présent document traite des CFN à col toroïdal et cylindrique pour lesquelles des étalonnages directs ont été effectués en nombre suffisant, pour permettre de déterminer les coefficients avec une marge prévisible d’incertitude.
Merjenje pretoka plina na podlagi kritičnega toka v Venturijevi šobi (ISO/FDIS 9300:2022)
General Information
RELATIONS
Standards Content (sample)
SLOVENSKI STANDARD
oSIST prEN ISO 9300:2021
01-september-2021
Merjenje pretoka plina na podlagi kritičnega toka v Venturijevi šobi (ISO/DIS
9300:2021)
Measurement of gas flow by means of critical flow nozzles (ISO/DIS 9300:2021)
Durchflussmessung von Gasen mit Venturidüsen bei kritischer Strömung (ISO/DIS
9300:2021)
Mesure de débit de gaz au moyen de Venturi-tuyères en régime critique (ISO/DIS
9300:2021)
Ta slovenski standard je istoveten z: prEN ISO 9300
ICS:
17.120.10 Pretok v zaprtih vodih Flow in closed conduits
oSIST prEN ISO 9300:2021 de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------oSIST prEN ISO 9300:2021
---------------------- Page: 2 ----------------------
oSIST prEN ISO 9300:2021
ENTWURF
EUROPÄISCHE NORM
prEN ISO 9300
EUROPEAN STANDARD
NORME EUROPÉENNE
Juli 2021
ICS 17.120.10 Vorgesehen als Ersatz für EN ISO 9300:2005
Deutsche Fassung
Durchflussmessung von Gasen mit Venturidüsen bei
kritischer Strömung (ISO/DIS 9300:2021)
Measurement of gas flow by means of critical flow Mesure de débit de gaz au moyen de Venturi-tuyères en
nozzles (ISO/DIS 9300:2021) régime critique (ISO/DIS 9300:2021)Dieser Europäische Norm-Entwurf wird den CEN-Mitgliedern zur parallelen Umfrage vorgelegt. Er wurde vom Technischen
Komitee CEN/SS F05 erstellt.Wenn aus diesem Norm-Entwurf eine Europäische Norm wird, sind die CEN-Mitglieder gehalten, die CEN-Geschäftsordnung zu
erfüllen, in der die Bedingungen festgelegt sind, unter denen dieser Europäischen Norm ohne jede Änderung der Status einer
nationalen Norm zu geben ist.Dieser Europäische Norm-Entwurf wurde von CEN in drei offiziellen Fassungen (Deutsch, Englisch, Französisch) erstellt. Eine
Fassung in einer anderen Sprache, die von einem CEN-Mitglied in eigener Verantwortung durch Übersetzung in seine
Landessprache gemacht und dem CEN-CENELEC-Management-Zentrum mitgeteilt worden ist, hat den gleichen Status wie die
offiziellen Fassungen.CEN-Mitglieder sind die nationalen Normungsinstitute von Belgien, Bulgarien, Dänemark, Deutschland, Estland, Finnland,
Frankreich, Griechenland, Irland, Island, Italien, Kroatien, Lettland, Litauen, Luxemburg, Malta, den Niederlanden, Norwegen,
Österreich, Polen, Portugal, der Republik Nordmazedonien, Rumänien, Schweden, der Schweiz, Serbien, der Slowakei, Slowenien,
Spanien, der Tschechischen Republik, der Türkei, Ungarn, dem Vereinigten Königreich und Zypern.
Die Empfänger dieses Norm-Entwurfs werden gebeten, mit ihren Kommentaren jegliche relevante Patentrechte, die sie kennen,
mitzuteilen und unterstützende Dokumentationen zur Verfügung zu stellen.Warnvermerk : Dieses Schriftstück hat noch nicht den Status einer Europäischen Norm. Es wird zur Prüfung und Stellungnahme
vorgelegt. Es kann sich noch ohne Ankündigung ändern und darf nicht als Europäischen Norm in Bezug genommen werden.
EUROPÄISCHES KOMITEE FÜR NORMUNGEUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
CEN-CENELEC Management-Zentrum: Rue de la Science 23, B-1040 Brüssel
© 2021 CEN Alle Rechte der Verwertung, gleich in welcher Form und in welchem Ref. Nr. prEN ISO 9300:2021 D
Verfahren, sind weltweit den nationalen Mitgliedern von CENvorbehalten.
---------------------- Page: 3 ----------------------
oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
Inhalt
Seite
Europäisches Vorwort................................................................................................................................................. 5
Vorwort ............................................................................................................................................................................ 6
1 Anwendungsbereich ..................................................................................................................................... 7
2 Normative Verweisungen ........................................................................................................................... 7
3 Begriffe .............................................................................................................................................................. 7
4 Symbole und Abkürzungen ..................................................................................................................... 12
5 Grundgleichungen ...................................................................................................................................... 15
5.1 Gasverhalten................................................................................................................................................. 15
5.1.1 Isentroper Prozess ..................................................................................................................................... 15
5.1.2 Zustandsgleichung...................................................................................................................................... 16
5.2 Isentrope Strömung eines idealen Gases ........................................................................................... 16
5.2.1 Strömungsquerschnitt .............................................................................................................................. 16
5.2.2 Statischer Druck .......................................................................................................................................... 16
5.2.3 Statische Temperatur................................................................................................................................ 16
5.3 Theoretische Variablen am kritischen Punkt .................................................................................. 16
5.3.1 Allgemeines................................................................................................................................................... 16
5.3.2 Kritischer Druck.......................................................................................................................................... 16
5.3.3 Kritische Temperatur ............................................................................................................................... 16
5.3.4 Kritische Dichte ........................................................................................................................................... 17
5.3.5 Kritische Geschwindigkeit....................................................................................................................... 17
5.4 Theoretischer Massendurchfluss ......................................................................................................... 17
5.4.1 Allgemeines................................................................................................................................................... 17
5.4.2 Theoretischer Massendurchfluss eines idealen Gases ................................................................. 17
5.4.3 Theoretischer Massendurchfluss eines realen Gases ................................................................... 17
5.5 Massendurchfluss ....................................................................................................................................... 17
6 Allgemeine Anforderungen..................................................................................................................... 18
7 Anwendungen, für die das Messverfahren geeignet ist ................................................................ 18
8 CFN ................................................................................................................................................................... 19
8.1 Allgemeine Anforderungen an beide Standardausführungen ................................................... 19
8.1.1 Allgemeines................................................................................................................................................... 19
8.1.2 Werkstoffe ..................................................................................................................................................... 19
8.1.3 Engstelle und Halsteil................................................................................................................................ 19
8.1.4 Diffusor ........................................................................................................................................................... 20
8.2 Anforderungen an die Standardausführungen................................................................................ 20
8.2.1 Standard-CFNs.............................................................................................................................................. 20
8.2.2 CFN mit Toroidhals..................................................................................................................................... 21
8.2.3 CFN mit Zylinderhals ................................................................................................................................. 22
9 Einbauanforderungen ............................................................................................................................... 24
9.1 Allgemeine Anforderungen an beide Standardkonfigurationen .............................................. 24
9.1.1 Standardkonfigurationen ........................................................................................................................ 24
9.1.2 Druckentnahmestelle im Einlaufrohr ................................................................................................. 24
9.1.3 Druckentnahmestelle am Auslaufrohr ............................................................................................... 25
9.1.4 Messung der Temperatur ........................................................................................................................ 25
---------------------- Page: 4 ----------------------oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
9.1.5 Messung der Dichte.....................................................................................................................................26
9.1.6 Entleerungsbohrung ..................................................................................................................................26
9.1.7 Bedingungen im Nachlaufrohr ...............................................................................................................26
9.2 Rohrkonfiguration ......................................................................................................................................26
9.2.1 Allgemeines ...................................................................................................................................................26
9.2.2 Einlaufrohr.....................................................................................................................................................26
9.2.3 Messung des Drucks ...................................................................................................................................27
9.2.4 Messung der Temperatur .........................................................................................................................28
9.3 Kammerkonfiguration...............................................................................................................................28
9.3.1 Allgemeines ...................................................................................................................................................28
9.3.2 Einlaufkammer.............................................................................................................................................28
9.3.3 Messung des Drucks ...................................................................................................................................28
9.3.4 Messung der Temperatur .........................................................................................................................28
9.3.5 Ausgangsdruckverhältnis.........................................................................................................................28
10 Berechnungen...............................................................................................................................................29
10.1 Allgemeines ...................................................................................................................................................29
10.2 Berechnung des Massendurchflusses, q ...........................................................................................29
10.3 Berechnung des Durchflusskoeffizienten, C ....................................................................................29
10.4 Berechnung der kritischen Durchflussfunktion, C* oder C* ......................................................30
10.5 Umrechnung des gemessenen Drucks in Ruhedruck.....................................................................31
10.6 Umrechnung der gemessenen Temperatur in Ruhetemperatur ...............................................31
10.7 Berechnung der Viskosität.......................................................................................................................31
11 Abschätzung des kritischen Ausgangsdruckverhältnisses ..........................................................31
11.1 Für herkömmlichen Diffusor bei Reynolds-Zahlen höher als 2 × 10 .....................................31
11.2 Für alle Diffusoren bei niedrigen Reynolds-Zahlen........................................................................32
11.3 Für CFNs ohne Diffusor oder mit sehr kurzem Diffusor................................................................33
12 Unsicherheiten bei der Durchflussmessung .....................................................................................33
12.1 Allgemeines ...................................................................................................................................................33
12.2 Praktische Berechnung der Messunsicherheit.................................................................................34
12.3 Korrelierte Unsicherheitskomponenten ............................................................................................35
Anhang A (informativ) Werte der Durchflusskoeffizienten ......................................................................37
Anhang B (informativ) Kritische Durchflussfunktion .................................................................................39
B.1 Allgemeines ...................................................................................................................................................39
B.2 Kritische Durchflussfunktion eines idealen Gases..........................................................................39
B.3 Kritische Durchflussfunktion eines realen Gases ...........................................................................40
B.4 Kritische Durchflussfunktion zur Verwendung bei Durchflusskalibrierung der CFN .......40
B.4.1 Allgemeines ...................................................................................................................................................40
B.4.2 Verwendung im gleichen Gas bei gleichen Ruhebedingungen ...................................................40
B.4.3 Verwendung im gleichen Gas im gleichen Bereich der Ruhebedingungen............................41
B.4.4 Bei Notwendig von genauen Werten ....................................................................................................41
B.5 Gase mit signifikantem Schwingungsrelaxationseffekt ................................................................41
Anhang C (normativ) Werte der kritischen Durchflussfunktion — Reingase und Luft...................42
C.1 Allgemeines ...................................................................................................................................................42
C.2 Stickstoff .........................................................................................................................................................43
C.3 Argon................................................................................................................................................................45
C.4 Trockene Luft mit Kohlenstoffdioxid (CIPM 2007-Zusammensetzung + CO /0,04 %) ..............47
C.5 Trockene Luft ohne Kohlenstoffdioxid (CIPM 2007-Zusammensetzung ohne CO )...........49
C.6 Luftfeuchtekorrektur für Luft mit einer typischen Zusammensetzung ..................................51
C.7 Methan.............................................................................................................................................................52
C.8 Kohlenstoffdioxid ........................................................................................................................................56
C.9 Sauerstoff........................................................................................................................................................59
---------------------- Page: 5 ----------------------oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
C.10 Dampf (Einphasengas).............................................................................................................................. 62
Anhang D (informativ) Berechnung des kritischen Massenstroms für Düsen bei kritischer
Strömung mit einem großen Durchmesserverhältnis Düsenhals/Einlaufrohr, β > 0,25 65
D.1 Allgemeines................................................................................................................................................... 65
D.2 Korrektionsfaktoren ................................................................................................................................. 65
Anhang E (informativ) Durchmesserkorrekturmethode .......................................................................... 69
E.1 Allgemeines................................................................................................................................................... 69
E.2 Durchführung............................................................................................................................................... 69
E.2.1 Visuelles Verfahren.................................................................................................................................... 70
E.2.2 Grobes Verfahren........................................................................................................................................ 70
E.2.3 Feines Verfahren......................................................................................................................................... 71
Anhang F (informativ) Anpassung der Durchflusskoeffizienten-Kurve an einen Datensatz ....... 74
F.1 Allgemeines................................................................................................................................................... 74
F.2 Anpassungsverfahren ............................................................................................................................... 75
Anhang G (informativ) Durchflusskoeffizient................................................................................................ 82
G.1 Allgemeines................................................................................................................................................... 82
G.2 Strömungsfeldverteilung entlang eines Durchmessers am kritischen Punkt ..................... 82
G.3 Abhängigkeit des Durchflusskoeffizienten von der Reynolds-Zahl ......................................... 83
G.4 Grenzschichtenübergang ......................................................................................................................... 84
G.5 Kurven der Durchflusskoeffizienten ................................................................................................... 85
G.6 Ermitteln der Kurven der Durchflusskoeffizienten ....................................................................... 86
Anhang H (informativ) Kritisches Ausgangsdruckverhältnis .................................................................. 87
H.1 Allgemeines................................................................................................................................................... 87
H.2 Theoretisches kritisches Ausgangsdruckverhältnis ..................................................................... 88
H.3 Beispiele für die typischen Drosselungsmuster mit dem Phänomen der vorzeitigen
Entdrosselung (PUP) ................................................................................................................................. 89
H.4 Drosselungsprüfung .................................................................................................................................. 92
H.4.1 Gegen eine Referenz-CFN ......................................................................................................................... 92
H.4.2 Gegen ein Referenz-Durchflussmessgerät......................................................................................... 93
Anhang I (informativ) Werte der Viskosität — Reingas und Luft ........................................................... 94
I.1 Allgemeines................................................................................................................................................... 94
I.2 Stickstoff......................................................................................................................................................... 96
I.3 Argon ............................................................................................................................................................... 96
I.4 Trockene Luft ............................................................................................................................................... 98
I.5 Methan ............................................................................................................................................................ 99
I.5 Kohlenstoffdioxid .....................................................................................................................................104
I.6 Sauerstoff .....................................................................................................................................................107
I.7 Dampf (Einphasengas)............................................................................................................................108
Anhang J (informativ) Begründung..................................................................................................................110
J.1 Allgemeines.................................................................................................................................................110
J.2 Ergänzungen zum Hauptteil .................................................................................................................110
Literaturhinweise ....................................................................................................................................................116
---------------------- Page: 6 ----------------------oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
Europäisches Vorwort
Dieses Dokument (prEN ISO 9300:2021) wurde vom Technischen Komitee ISO/TC 30 „Measurement of fluid
flow in closed conduits“ in Zusammenarbeit mit dem Technischen Komitee CEN/SS F05 „Messinstrumente“
erarbeitet, dessen Sekretariat von CCMC gehalten wird.Dieses Dokument ist derzeit zur parallelen Umfrage vorgelegt.
Dieses Dokument wird EN ISO 9300:2005 ersetzen.
Anerkennungsnotiz
Der Text von ISO/DIS 9300:2021 wurde von CEN als prEN ISO 9300:2021 ohne irgendeine Abänderung
genehmigt.Rückmeldungen oder Fragen zu diesem Dokument sollten an das jeweilige nationale Normungsinstitut des
Anwenders gerichtet werden. Eine vollständige Liste dieser Institute ist auf den Internetseiten von CEN
abrufbar.---------------------- Page: 7 ----------------------
oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
Vorwort
ISO (die Internationale Organisation für Normung) ist eine weltweite Vereinigung nationaler Normungs-
institute (ISO-Mitgliedsorganisationen). Die Erstellung von Internationalen Normen wird üblicherweise von
Technischen Komitees von ISO durchgeführt. Jede Mitgliedsorganisation, die Interesse an einem Thema hat,
für welches ein Technisches Komitee gegründet wurde, hat das Recht, in diesem Komitee vertreten zu sein.
Internationale staatliche und nichtstaatliche Organisationen, die in engem Kontakt mit ISO stehen, nehmen
ebenfalls an der Arbeit teil. ISO arbeitet bei allen elektrotechnischen Normungsthemen eng mit der
Internationalen Elektrotechnischen Kommission (IEC) zusammen.Die Verfahren, die bei der Entwicklung dieses Dokuments angewendet wurden und die für die weitere Pflege
vorgesehen sind, werden in den ISO/IEC-Direktiven, Teil 1 beschrieben. Es sollten insbesondere die
unterschiedlichen Annahmekriterien für die verschiedenen ISO-Dokumentenarten beachtet werden. Dieses
Dokument wurde in Übereinstimmung mit den Gestaltungsregeln der ISO/IEC-Direktiven, Teil 2 erarbeitet
(siehe www.iso.org/directives).Es wird auf die Möglichkeit hingewiesen, dass einige Elemente dieses Dokuments Patentrechte berühren
können. ISO ist nicht dafür verantwortlich, einige oder alle diesbezüglichen Patentrechte zu identifizieren.
Details zu allen während der Entwicklung des Dokuments identifizierten Patentrechten finden sich in der
Einleitung und/oder in der ISO-Liste der erhaltenen Patenterklärungen (siehe www.iso.org/patents).
Jeder in diesem Dokument verwendete Handelsname dient nur zur Unterrichtung der Anwender und bedeutet
keine Anerkennung.Für eine Erläuterung des freiwilligen Charakters von Normen, der Bedeutung ISO-spezifischer Begriffe und
Ausdrücke in Bezug auf Konformitätsbewertungen sowie Informationen darüber, wie ISO die Grundsätze der
Welthandelsorganisation (WTO, en: World Trade Organization) hinsichtlich technischer Handelshemmnisse
(TBT, en: Technical Barriers to Trade) berücksichtigt, siehe www.iso.org/iso/foreword.html.
ISO 9300 wurde vom Technischen Komitee ISO/TC 30, Measurement of fluid flow in closed conduits,
Unterkomitee SC 2, Pressure differential devices, erarbeitet.Diese dritte Ausgabe ersetzt die zweite Ausgabe (ISO 9300:2005), die technisch überarbeitet wurde.
Die in dieser Norm enthaltenen Informationen wurden aus vielen veröffentlichten Dokumenten und basierend
auf der Erfahrung der Mitglieder des Technischen Komitees und anderer sachkundiger Ingenieure
zusammengetragen. Diese Norm vereint verfügbare technische Informationen und bewährte Praktiken und
soll ein praktischer Leitfaden für die ordnungsgemäße Verwendung von Düsen bei kritischer Strömung sein.
Rückmeldungen oder Fragen zu diesem Dokument sollten an das jeweilige nationale Normungsinstitut des
Anwenders gerichtet werden. Eine vollständige Auflistung dieser Institute ist unter
www.iso.org/members.html zu finden.---------------------- Page: 8 ----------------------
oSIST prEN ISO 9300:2021
prEN ISO 9300:2021 (D)
1 Anwendungsbereich
Diese Internationale Norm legt die geometrische Gestalt und die Betriebsweise (Einbau in ein System und
Betriebsbedingungen) von Düsen bei kritischer Strömung (CFNs, en: critical flow nozzles) fest, die den
Massendurchfluss eines durch ein System strömenden Gases bestimmen, ohne die CFN grundsätzlich zu
kalibrieren. Sie enthält außerdem die notwendigen Angaben für die Berechnung des Durchflusses und der
zugehörigen Unsicherheit.Muss der Durchfluss CFN kalibriert werden, müssen alle Anschlüsse, Betriebsbedingungen und Berechnungen
den Vorgaben der Kalibriereinrichtung entsprechen, was in dieser Internationalen Norm nicht abgedeckt
wird. Für einige Bedingungen, wie z. B. kleine CFNs oder Gas mit signifikantem Schwingungsrelaxationseffekt
usw., wird die Durchflusskalibrierung empfohlen.Diese Internationale Norm gilt für Düsen, in denen das Gas im kleinsten Strömungsquerschnitt auf die
kritische Strömungsgeschwindigkeit beschleunigt wird und eine gleichbleibende Strömung nur für
einphasiges Gas vorliegt. Bei Erreichen der kritischen Geschwindigkeit in der Düse hat der Massendurchfluss
des durch die Düse strömenden Gases unter den auf der Einlaufseite vorhandenen Bedingungen sein
Maximum, wobei die CFN nur innerhalb festgelegter Grenzen eingesetzt werden kann, z. B. das Verhältnis von
Halsteil der CFN zum Durchmesser des Einlaufrohrs und Reynolds-Zahl. Diese Internationale Norm behandelt
CFNs mit Toroid- und Zylinderhals, die in ausreichend häufigen Versuchen direkt kalibriert wurden, wodurch
die sich draus ergebenden Koeffizienten mit vorhersagbaren Grenzwerten für die Unsicherheit angewendet
werden können.Sie enthält Angaben für Fälle, in denen die Rohrleitung vor der CFN einen kreisrunden Querschnitt aufweist,
oder in denen ein großes Volumen (eine Kammer) vor der CFN oder vor einer Reihe von CFNs vorhanden ist.
Die Raumkonfiguration bietet die Möglichkeit, CFNs in Parallelschaltung einzubauen, um damit große
Durchflüsse und/oder veränderliche Volumendurchflüsse zu erzielen.Zu Informationszwecken wird die Durchmesserkorrekturmethode (DCM, en: diameter correctio
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.