Q3 interface at the Local Exchange (LE) for line and circuit testing of analogue and Integrated Services Digital Network (ISDN) subscriber lines; Part 1: Q3 interface specification

DEN/SPS-03030-1

Vmesnik Q3 pri krajevni centrali za preskušanje vodov in vezij analognih in ISDN naročniških priključkov - 1. del: Specifikacija za vmesnik Q3

General Information

Status
Published
Publication Date
11-Aug-1998
Technical Committee
Current Stage
12 - Completion
Due Date
28-Aug-1998
Completion Date
12-Aug-1998

Buy Standard

Standard
EN 301 006-1 V1.2.2:2005
English language
62 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 301 006-1 V1.2.2:2005
01-julij-2005
9PHVQLN4SULNUDMHYQLFHQWUDOL]DSUHVNXãDQMHYRGRYLQYH]LMDQDORJQLKLQ,6'1
QDURþQLãNLKSULNOMXþNRYGHO6SHFLILNDFLMD]DYPHVQLN4
Q3 interface at the Local Exchange (LE) for line and circuit testing of analogue and
Integrated Services Digital Network (ISDN) subscriber lines; Part 1: Q3 interface
specification
Ta slovenski standard je istoveten z: EN 301 006-1 Version 1.2.2
ICS:
33.080 Digitalno omrežje z Integrated Services Digital
integriranimi storitvami Network (ISDN)
(ISDN)
SIST EN 301 006-1 V1.2.2:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 301 006-1 V1.2.2:2005

---------------------- Page: 2 ----------------------

SIST EN 301 006-1 V1.2.2:2005
EN 301 006-1 V1.2.2 (1998-08)
European Standard (Telecommunications series)
Q3 interface at the Local Exchange (LE)
for line and circuit testing of analogue
and Integrated Services Digital network (ISDN)
subscriber lines;
Part 1: Q3 interface specification

---------------------- Page: 3 ----------------------

SIST EN 301 006-1 V1.2.2:2005
2 EN 301 006-1 V1.2.2 (1998-08)
Reference
DEN/SPS-03030-1 (9bc90ipc.PDF)
Keywords
TMN, information model, Q3 interface, LE, fault,
testing, management, PSTN, ISDN
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
http://www.etsi.fr
http://www.etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1998.
All rights reserved.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 301 006-1 V1.2.2:2005
3 EN 301 006-1 V1.2.2 (1998-08)
Contents
Intellectual Property Rights.7
Foreword .7
Introduction .7
1 Scope.9
2 References.9
3 Definitions and abbreviations .10
3.1 Definitions . 10
3.2 Abbreviations. 11
4 Information model diagrams .12
4.1 Entity relationship diagram. 12
4.1.1 Line testing and line circuit testing. 13
4.1.2 The testResultNotifications of the tests . 13
4.2 Inheritance hierarchy . 14
4.3 Naming hierarchy. 14
5 Information model description.15
5.1 Description of object classes. 15
5.1.1 Access port fragment. 15
5.1.2 Support fragment. 15
5.1.2.1 Event report management . 15
5.1.2.2 Log control function . 15
5.1.3 Test fragment . 16
5.1.3.1 Access test (accessTest). 16
5.1.3.2 Dialled digit test (dialledDigitTest) . 16
5.1.3.3 Dial tone test (dialToneTest) . 16
5.1.3.4 Electrical measurement test (electricalMeasurementTest). 17
5.1.3.5 Subscriber Private Meter (SPM) pulses (spmPulses) . 17
5.1.3.6 Cable pair identification tone (cablePairIdTone). 17
5.1.3.7 Ringing (ringing) . 17
5.1.3.8 Test to line circuit (testToLineCircuit) . 17
5.1.3.9 Dry Loop (dryLoop) . 17
5.1.3.10 Loop test (loopTest) . 18
5.1.3.11 Pattern test (patternTest). 18
5.1.3.12 Voice access test (voiceAccessTest). 18
5.1.3.13 Metallic test access (metallicTestAccess). 19
5.1.3.14 Test threshold class administration (testThresholdClass) . 19
5.1.3.15 ISDN quick test (isdnQuickTest). 20
5.2 Definition of attributes. 20
5.2.1 Relative distinguished name. 20
5.2.2 State attributes. 20
5.2.2.1 Operational state (operationalState) . 20
5.2.2.2 Administrative state (administrativeState). 21
5.2.2.3 Availability status (availabilityStatus) . 21
5.2.3 Relationship attributes. 21
5.3 Actions description . 21
5.4 Notifications description. 21
6 Formal object class definitions .22
6.1 Definitions of object classes . 22
6.1.1 Access port fragment. 22
6.1.2 Support fragment. 22
6.1.3 Test fragment . 22
6.1.3.1 ISDN quick test . 23
6.1.3.2 Metallic test access . 23
ETSI

---------------------- Page: 5 ----------------------

SIST EN 301 006-1 V1.2.2:2005
4 EN 301 006-1 V1.2.2 (1998-08)
6.1.3.3 Test threshold class. 24
6.2 Name bindings . 24
6.2.1 Test fragment . 24
6.2.1.1 ISDN quick test . 24
6.2.1.2 Metallic test access . 24
6.2.1.3 Test threshold class. 24
6.3 Definition of packages . 25
6.3.1 Metallic test access line package. 25
6.4 Definition of attributes. 25
6.4.1 AC voltage threshold. 25
6.4.2 Capacitance threshold . 25
6.4.3 DC voltage threshold. 25
6.4.4 Dial speed threshold. 25
6.4.5 ISDN quick test. 26
6.4.6 Metallic test access message . 26
6.4.7 Metallic test access timeout period. 26
6.4.8 Proposed metallic test access . 27
6.4.9 Pulse no pulse ratio . 27
6.4.10 Resistance threshold. 27
6.4.11 Test threshold class ID . 27
6.4.12 Type of line . 27
6.5 Definition of actions . 27
6.6 Definition of notifications. 27
6.7 Definition of parameters . 27
6.8 ASN.1 defined types module . 29
7 Protocol requirements .31
Annex A (normative): Requirements and specification of parameters for access port tests.32
A.1 General test requirements .32
A.1.1 Scheduled testing . 32
A.1.2 Test capability. 32
A.2 Access port test requirements .32
A.2.1 Access port test management functions . 32
A.2.2 Test scheduling . 33
A.2.3 Test result management . 33
A.2.4 Test threshold management. 34
A.2.5 Test requirements description . 34
A.2.5.1 PSTN line testing . 34
A.2.5.1.1 Foreign voltage or current . 34
A.2.5.1.2 Capacitance measurement. 34
A.2.5.1.3 Insulation resistance measurement. 34
A.2.5.1.4 Loop resistance measurement. 35
A.2.5.1.5 Dial pulse test . 35
A.2.5.1.6 DTMF dialling test . 35
A.2.5.1.7 Subscriber private meter testing . 35
A.2.5.1.8 Ring subscriber. 35
A.2.5.1.9 Monitoring of the line. 35
A.2.5.1.10 Cable pair identification tone. 35
A.2.5.1.11 Dry loop. 35
A.2.5.1.12 Register recall button test . 36
A.2.5.1.13 Ring back procedure. 36
A.2.5.2 PSTN inward tests. 36
A.2.5.2.1 Line circuit testing . 36
A.2.5.2.1.1 Feeding voltage. 36
A.2.5.2.1.2 Feeding current . 36
A.2.5.2.1.3 Loop and ring trip detection. 36
A.2.5.2.1.4 Ringing current sending . 36
A.2.5.2.1.5 Private meter pulses . 36
A.2.5.2.1.6 Codec testing. 37
ETSI

---------------------- Page: 6 ----------------------

SIST EN 301 006-1 V1.2.2:2005
5 EN 301 006-1 V1.2.2 (1998-08)
A.2.5.2.1.7 Digit reception . 37
A.2.5.2.2 Other inward tests. 37
A.2.5.2.2.1 Dial tone test . 37
A.2.5.3 ISDN BA testing . 37
A.2.5.3.1 ISDN BA line testing. 37
A.2.5.3.2 ISDN BA line termination testing. 37
A.2.5.3.2.1 Loopbacks. 37
A.2.5.3.2.2 Activation and deactivation of lines. 38
A.2.5.3.3 ISDN BA line circuit testing. 38
A.2.5.3.3.1 Power feed . 38
A.2.5.4 ISDN PRA testing . 38
A.2.5.4.1 ISDN PRA line testing. 38
A.2.5.4.2 ISDN PRA line termination testing . 38
A.2.5.5 ISDN BA and PRA quick tests. 38
A.2.5.6 Connection of external test systems . 38
Annex B (normative): Test categories.39
B.1 Electrical measurement tests.39
B.2 Dialled digit test.40
B.3 Dial tone test .41
B.4 Subscriber private meter pulses test.42
B.5 Ringing test .42
B.6 Test to line circuit .43
B.7 ISDN loopback test .44
B.8 ISDN quick test.45
Annex C (normative): Test termination.47
C.1 Termination of uncontrolled tests .47
C.2 Termination of controlled tests .47
Annex D (normative): Test result notification .49
Annex E (normative): Additional requirements on the test action performer.50
E.1 Indication of supported tests .50
E.2 Indication of unsuccessful test requests.50
Annex F (informative): Task Information Base (TIB) .51
F.1 Description of the service .51
F.2 Components of service (TIB A).51
F.3 Management function list (TIB B).52
Annex G (informative): Description of management functions .53
G.1 Model for the test function.53
G.1.1 Environment. 53
G.1.2 Uncontrolled tests . 53
G.1.3 Controlled tests . 54
G.2 Functional model.55
G.2.1 Test initiation. 55
G.2.2 Test scheduling . 55
G.2.3 Reporting of test results . 56
G.2.4 Test suspension and resumption. 57
ETSI

---------------------- Page: 7 ----------------------

SIST EN 301 006-1 V1.2.2:2005
6 EN 301 006-1 V1.2.2 (1998-08)
G.2.5 Test termination . 57
Annex H (informative): Message flows.58
Annex J (informative): Bibliography.61
History.62
ETSI

---------------------- Page: 8 ----------------------

SIST EN 301 006-1 V1.2.2:2005
7 EN 301 006-1 V1.2.2 (1998-08)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect
of ETSI standards", which is available free of charge from the ETSI Secretariat. Latest updates are available on the
ETSI Web server (http://www.etsi.fr/ipr or http://www.etsi.org/ipr).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)
which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Signalling
Protocols and Switching (SPS).
The present document is part 1 of a multi-part document covering the Q3 interface at the Local Exchange (LE) for line
and circuit testing of analogue and ISDN subscriber lines, as identified below:
Part 1: "Q3 interface specification";
Part 2: "Managed Object Conformance Statement (MOCS) proforma specification".
Proposed national transposition dates
Date of adoption of this EN: 7 August 1998
Date of latest announcement of this EN (doa): 30 November 1998
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 May 1999
Date of withdrawal of any conflicting National Standard (dow): 31 May 1999
Introduction
Line and circuit testing of analogue and ISDN lines is part of a management activity which is performed by the operator
in order to detect failure conditions and to bring the customer access back to its normal state of operation whenever a
deviation occurs.
A customer access is considered as being that part of the local network which extends from the network termination
equipment up to and including the exchange termination.
Here, only these parts of the activity are covered which are related directly to that part of the customer access which
extends from the LE to the network termination equipment. An ISDN access extends to but does not include the
T reference point. An analogue access extends to and may include the Customer Premise Equipment (CPE)
(see figure 1).
ETSI

---------------------- Page: 9 --------------------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.