ETSI EN 300 176-1 V2.4.1 (2022-11)
Digital Enhanced Cordless Telecommunications (DECT); Test specification; Part 1: Radio
Digital Enhanced Cordless Telecommunications (DECT); Test specification; Part 1: Radio
REN/DECT-00365
Digitalne izboljšane brezvrvične telekomunikacije (DECT) - Specifikacija preskusa - 1. del: Radio
Ta dokument določa preskuse, ki se uporabljajo za vso opremo za digitalne izboljšane brezvrvične telekomunikacije (DECT), ki dostopa do frekvenčnega pasu od 1880 MHz do 1900 MHz (vključno z ukrepi za preskušanje drugih ali razširjenih frekvenčnih pasov, kot so opisani v standardih ETSI EN 300 175-1 [i.11] in ETSI EN 300 175-2 [1]). 2. del tega večdelnega dokumenta [i.15] določa preskuse, ki se uporabljajo za prenos govora in zvoka prek digitalnih izboljšanih brezvrvičnih telekomunikacij z zbirko govornih kodekov, vključno s kodekom ADPCM iz priporočila ITU-T G.726 [i.7], 7-kHz kodekom iz priporočila ITU-T G.722 [i.8], kodekom MPEG-4 [i.10], LC3plus [i.24] in drugimi. Cilj tega dokumenta je zagotoviti: • učinkovito uporabo frekvenčnega spektra; • preprečitev okvar katerega koli priključenega omrežja in njegovih storitev; • preprečitev okvar drugih radijskih omrežij in storitev; • preprečitev okvar druge opreme za digitalne izboljšane brezvrvične komunikacije ali njenih storitev; • medsebojno delovanje terminalske opreme prek javnega omrežja. Preskusi iz standarda ETSI EN 300 176 so razdeljeni na dva dela: • ta dokument (1. del) zajema preskušanje parametrov radijskih frekvenc, varnostnih elementov in protokolov digitalnih izboljšanih brezvrvičnih telekomunikacij, ki omogočajo lažje izvajanje preskusov radijskih frekvenc ter učinkovito uporabo frekvenčnega spektra; • 2. del [i.15] opisuje preskušanje zahtev za govor in zvok med omrežnim vmesnikom ter prenosnimi radijskimi priključki digitalnih izboljšanih brezvrvičnih telekomunikacij (DECT PT) ali med skupnim radijskim vmesnikom digitalnih izboljšanih brezvrvičnih telekomunikacij (DECT CI) in prenosnim radijskim priključkom digitalnih izboljšanih brezvrvičnih telekomunikacij (DECT PT) ali alternativno fiksnim radijskim priključkom digitalnih izboljšanih brezvrvičnih telekomunikacij (DECT FT). 2. del se ne uporablja za terminalsko opremo, ki je posebej zasnovana za invalide (npr. s povečanjem glasnosti prejetega govora kot pomočjo za naglušne osebe). Terminalska oprema digitalnih izboljšanih brezvrvičnih telekomunikacij je sestavljena iz naslednjih elementov: a) fiksni del (FP); b) prenosni del (PP); c) brezvrvični terminalski prilagodilnik (CTA); d) brezžična relejna postaja (WRS) (fiksni in prenosni del skupaj); e) hibridni del (HyP) (prenosni del z zmožnostjo delovanja kot fiksni del za namen zagotovitve komunikacije med dvema prenosnima deloma). Podrobnosti skupnega vmesnika za digitalne izboljšane brezvrvične telekomunikacije so navedene v standardih ETSI EN 300 175-1 [i.11], ETSI EN 300 175 (2. del [1] in 3. del [2]), ETSI EN 300 175-4 [i.12], ETSI EN 300 175 (5. del [3] in 6. del [4]) ter ETSI EN 300 175 (7. del [i.13] in 8. del [i.14]). Dodatne podrobnosti o sistemu digitalne izboljšane brezvrvične telekomunikacije so navedene v tehničnem poročilu ETSI TR 101 178 [i.1]. Informacije o ultra nizki porabi energije (ULE) so navedene v tehničnih specifikacijah ETSI TS 102 939-1 [i.20] in ETSI TS 102 939-2 [i.21].
General Information
Buy Standard
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 300 176-1 V2.4.1:2023
01-januar-2023
Digitalne izboljšane brezvrvične telekomunikacije (DECT) - Specifikacija preskusa
- 1. del: Radio
Digital Enhanced Cordless Telecommunications (DECT) - Test specification - Part 1:
Radio
Ta slovenski standard je istoveten z: ETSI EN 300 176-1 V2.4.1 (2022-11)
ICS:
33.070.30 Digitalne izboljšane Digital Enhanced Cordless
brezvrvične telekomunikacije Telecommunications (DECT)
(DECT)
SIST EN 300 176-1 V2.4.1:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 300 176-1 V2.4.1:2023
---------------------- Page: 2 ----------------------
SIST EN 300 176-1 V2.4.1:2023
ETSI EN 300 176-1 V2.4.1 (2022-11)
EUROPEAN STANDARD
Digital Enhanced Cordless Telecommunications (DECT);
Test specification;
Part 1: Radio
---------------------- Page: 3 ----------------------
SIST EN 300 176-1 V2.4.1:2023
2 ETSI EN 300 176-1 V2.4.1 (2022-11)
Reference
REN/DECT-00365
Keywords
DECT, radio, regulation, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2022.
All rights reserved.
ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 176-1 V2.4.1:2023
3 ETSI EN 300 176-1 V2.4.1 (2022-11)
Contents
Intellectual Property Rights . 11
Foreword . 11
Modal verbs terminology . 12
1 Scope . 13
2 References . 13
2.1 Normative references . 13
2.2 Informative references . 14
3 Definition of terms, symbols and abbreviations . 15
3.1 Terms . 15
3.2 Symbols . 18
3.3 Abbreviations . 18
4 General . 20
4.1 Document layout . 20
4.1.1 Test suites . 20
4.1.2 Test groups. 20
4.1.3 Test cases . 21
4.2 Presentation of equipment for testing purposes . 21
4.2.0 General . 21
4.2.1 Choice of model for testing (if applicable) . 21
4.2.2 Description of equipment . 22
4.2.2.0 General . 22
4.2.2.1 Protocol Implementation Conformance Statement (PICS) . 22
4.2.2.2 Protocol Implementation eXtra Information for Testing (PIXIT) . 22
4.2.2.3 Environmental test conditions . 22
4.2.3 Host connected equipment . 22
4.2.4 Manufacturer's declaration . 23
4.3 Applicability of tests . 23
4.3.0 General . 23
4.3.1 Equipment that includes only a DECT RF receiver . 23
4.3.2 Equipment that includes a radio transmitter . 23
4.3.3 CTAs . 23
4.3.4 Equipment with a synchronization port . 23
4.3.5 Equipment incorporating the IPEI (PPs only) . 23
4.3.6 All FP equipment . 23
4.3.7 PPs with direct PP to PP communication option . 23
4.3.8 Installation related issues . 24
4.3.9 Equipment with combined FT and PT functionality . 24
4.3.9.0 General . 24
4.3.9.1 Wireless Relay Station . 24
4.3.9.2 Direct PP to PP communication . 24
4.3.9.3 Distributed communications . 24
4.3.10 Equipment that is capable of using higher level modulation . 25
4.3.11 Equipment supporting additional carriers . 25
4.4 Interpretation of the measurement results . 25
5 General test requirements . 25
5.1 Test philosophy . 25
5.2 Test site . 26
5.2.1 Open air test site . 26
5.2.1.1 Description . 26
5.2.1.2 Calibration . 27
5.2.2 Anechoic chamber . 28
5.2.2.1 General . 28
5.2.2.2 Description . 28
5.2.2.3 Influence of parasitic reflections . 31
ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 176-1 V2.4.1:2023
4 ETSI EN 300 176-1 V2.4.1 (2022-11)
5.2.2.4 Calibration and mode of use. 31
5.2.3 Stripline coupler . 31
5.2.3.0 General . 31
5.2.3.1 Description . 31
5.2.3.2 Calibration . 31
5.2.3.3 Mode of use . 31
5.3 Standard position . 32
5.4 Test antenna of the LT . 32
5.5 Substitution antenna . 32
5.6 Test fixture . 32
5.6.1 Description . 32
5.6.1.0 General . 32
5.6.1.1 Calibration of the test fixture for the measurement of transmitter characteristics . 33
5.6.1.2 Calibration of the test fixture for the measurement of receiver characteristics . 33
5.6.1.3 Mode of use . 34
5.6.2 Equipment with a temporary or internal permanent antenna connector. 34
5.6.2.0 General . 34
5.6.2.1 Equipment with a temporary antenna connector . 34
5.7 Indoor test site . 35
5.7.0 General . 35
5.7.1 Description . 35
5.7.2 Test for parasitic reflections. 36
5.7.3 Calibration and mode of use . 36
5.8 Lower Tester (LT) . 36
5.8.1 Description . 36
5.8.2 Connections between the EUT and the LT . 37
5.8.3 Functions and abilities . 37
5.8.4 Signal generation uncertainty . 38
5.8.4.0 General . 38
5.8.4.1 Modulated DECT-like carrier . 38
5.8.4.2 CW interferers . 38
5.8.4.3 DECT RF signal . 38
5.8.4.4 Test modulation signals . 38
5.8.5 Measurement uncertainty . 38
5.9 Upper Tester (UT) . 39
5.9.1 Description of the UT . 39
5.9.2 The test standby mode . 39
5.9.3 Test messages . 39
5.9.4 Dummy setting when EUT is a RFP and it is in test stand-by mode . 40
5.10 Description of the lower tester FT and PT . 40
5.11 General test methods . 40
5.11.1 General . 40
5.11.2 Sampling the RF signal . 40
5.11.2.1 Introduction . 40
5.11.2.2 Sampling method . 40
5.11.3 Determining the reference position . 40
5.11.3.0 General . 40
5.11.3.1 Case 1: EUTs that cannot transmit . 41
5.11.3.2 Case 2: EUTs that can transmit . 41
5.11.4 Bit Error Rate (BER) and Frame Error Ratio (FER) measurements . 41
5.12 Test setup. 41
5.12.0 General . 41
5.12.1 Test setup 1 . 41
5.12.2 Test setup 2 . 41
5.12.3 Test setup 3 . 42
5.12.4 Test setup 4 . 43
5.12.5 Void . 43
5.13 Test arrangements for intermodulation measurements . 43
5.13.1 PT to PT arrangement . 43
5.13.2 FT to FT arrangement . 44
5.13.3 FT to PT arrangement . 44
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 176-1 V2.4.1:2023
5 ETSI EN 300 176-1 V2.4.1 (2022-11)
6 Test conditions, power sources and ambient temperatures . 45
6.1 General . 45
6.2 Nominal test conditions . 45
6.3 Extreme test conditions . 46
6.4 Test power source - general requirements . 47
6.5 Nominal test power source . 47
6.5.1 Mains voltage . 47
6.5.2 Regulated lead acid battery power sources . 47
6.5.3 Nickel cadmium or nickel metal hydride battery . 47
6.5.4 Other power sources . 47
6.6 Extreme test power source. 48
6.6.1 Mains voltage . 48
6.6.2 Regulated lead acid battery power sources . 48
6.6.3 Nickel cadmium or nickel metal hydride battery . 48
6.6.4 Other power sources . 48
6.7 Testing of host connected equipment and plug-in cards. 48
6.7.0 Approaches . 48
6.7.1 Alternative A: composite equipment . 48
6.7.2 Alternative B: use of a test jig and three hosts . 49
7 Accuracy and stability of RF carriers . 49
7.0 Requirements . 49
7.1 Definition . 49
7.2 Test environment . 50
7.3 Method of measurement . 50
7.4 Verdict criteria when the EUT is a RFP . 51
7.5 Verdict criteria when the EUT is a PP . 51
8 Accuracy and stability of timing parameters . 51
8.0 Requirements . 51
8.0.1 General . 51
8.0.2 Limits . 51
8.0.2.1 Reference timer accuracy and stability . 51
8.0.2.2 RFP transmission jitter . 51
8.0.2.3 PP reference timer synchronization . 52
8.1 Slot structure definitions . 52
8.2 Definition of the position of p0 . 52
8.3 Measurement of packet timing jitter . 52
8.3.1 Test environment . 52
8.3.2 Method of measurement . 53
8.3.3 Verdict criteria . 53
8.4 Measurement of the reference timing accuracy of a RFP . 53
8.4.1 Test environment . 53
8.4.2 Method of measurement . 53
8.4.3 Verdict criteria . 54
8.5 Measurement of packet transmission accuracy of a PP . 54
8.5.1 Test environment .
...
ETSI EN 300 176-1 V2.4.1 (2022-11)
EUROPEAN STANDARD
Digital Enhanced Cordless Telecommunications (DECT);
Test specification;
Part 1: Radio
---------------------- Page: 1 ----------------------
2 ETSI EN 300 176-1 V2.4.1 (2022-11)
Reference
REN/DECT-00365
Keywords
DECT, radio, regulation, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2022.
All rights reserved.
ETSI
---------------------- Page: 2 ----------------------
3 ETSI EN 300 176-1 V2.4.1 (2022-11)
Contents
Intellectual Property Rights . 11
Foreword . 11
Modal verbs terminology . 12
1 Scope . 13
2 References . 13
2.1 Normative references . 13
2.2 Informative references . 14
3 Definition of terms, symbols and abbreviations . 15
3.1 Terms . 15
3.2 Symbols . 18
3.3 Abbreviations . 18
4 General . 20
4.1 Document layout . 20
4.1.1 Test suites . 20
4.1.2 Test groups. 20
4.1.3 Test cases . 21
4.2 Presentation of equipment for testing purposes . 21
4.2.0 General . 21
4.2.1 Choice of model for testing (if applicable) . 21
4.2.2 Description of equipment . 22
4.2.2.0 General . 22
4.2.2.1 Protocol Implementation Conformance Statement (PICS) . 22
4.2.2.2 Protocol Implementation eXtra Information for Testing (PIXIT) . 22
4.2.2.3 Environmental test conditions . 22
4.2.3 Host connected equipment . 22
4.2.4 Manufacturer's declaration . 23
4.3 Applicability of tests . 23
4.3.0 General . 23
4.3.1 Equipment that includes only a DECT RF receiver . 23
4.3.2 Equipment that includes a radio transmitter . 23
4.3.3 CTAs . 23
4.3.4 Equipment with a synchronization port . 23
4.3.5 Equipment incorporating the IPEI (PPs only) . 23
4.3.6 All FP equipment . 23
4.3.7 PPs with direct PP to PP communication option . 23
4.3.8 Installation related issues . 24
4.3.9 Equipment with combined FT and PT functionality . 24
4.3.9.0 General . 24
4.3.9.1 Wireless Relay Station . 24
4.3.9.2 Direct PP to PP communication . 24
4.3.9.3 Distributed communications . 24
4.3.10 Equipment that is capable of using higher level modulation . 25
4.3.11 Equipment supporting additional carriers . 25
4.4 Interpretation of the measurement results . 25
5 General test requirements . 25
5.1 Test philosophy . 25
5.2 Test site . 26
5.2.1 Open air test site . 26
5.2.1.1 Description . 26
5.2.1.2 Calibration . 27
5.2.2 Anechoic chamber . 28
5.2.2.1 General . 28
5.2.2.2 Description . 28
5.2.2.3 Influence of parasitic reflections . 31
ETSI
---------------------- Page: 3 ----------------------
4 ETSI EN 300 176-1 V2.4.1 (2022-11)
5.2.2.4 Calibration and mode of use. 31
5.2.3 Stripline coupler . 31
5.2.3.0 General . 31
5.2.3.1 Description . 31
5.2.3.2 Calibration . 31
5.2.3.3 Mode of use . 31
5.3 Standard position . 32
5.4 Test antenna of the LT . 32
5.5 Substitution antenna . 32
5.6 Test fixture . 32
5.6.1 Description . 32
5.6.1.0 General . 32
5.6.1.1 Calibration of the test fixture for the measurement of transmitter characteristics . 33
5.6.1.2 Calibration of the test fixture for the measurement of receiver characteristics . 33
5.6.1.3 Mode of use . 34
5.6.2 Equipment with a temporary or internal permanent antenna connector. 34
5.6.2.0 General . 34
5.6.2.1 Equipment with a temporary antenna connector . 34
5.7 Indoor test site . 35
5.7.0 General . 35
5.7.1 Description . 35
5.7.2 Test for parasitic reflections. 36
5.7.3 Calibration and mode of use . 36
5.8 Lower Tester (LT) . 36
5.8.1 Description . 36
5.8.2 Connections between the EUT and the LT . 37
5.8.3 Functions and abilities . 37
5.8.4 Signal generation uncertainty . 38
5.8.4.0 General . 38
5.8.4.1 Modulated DECT-like carrier . 38
5.8.4.2 CW interferers . 38
5.8.4.3 DECT RF signal . 38
5.8.4.4 Test modulation signals . 38
5.8.5 Measurement uncertainty . 38
5.9 Upper Tester (UT) . 39
5.9.1 Description of the UT . 39
5.9.2 The test standby mode . 39
5.9.3 Test messages . 39
5.9.4 Dummy setting when EUT is a RFP and it is in test stand-by mode . 40
5.10 Description of the lower tester FT and PT . 40
5.11 General test methods . 40
5.11.1 General . 40
5.11.2 Sampling the RF signal . 40
5.11.2.1 Introduction . 40
5.11.2.2 Sampling method . 40
5.11.3 Determining the reference position . 40
5.11.3.0 General . 40
5.11.3.1 Case 1: EUTs that cannot transmit . 41
5.11.3.2 Case 2: EUTs that can transmit . 41
5.11.4 Bit Error Rate (BER) and Frame Error Ratio (FER) measurements . 41
5.12 Test setup. 41
5.12.0 General . 41
5.12.1 Test setup 1 . 41
5.12.2 Test setup 2 . 41
5.12.3 Test setup 3 . 42
5.12.4 Test setup 4 . 43
5.12.5 Void . 43
5.13 Test arrangements for intermodulation measurements . 43
5.13.1 PT to PT arrangement . 43
5.13.2 FT to FT arrangement . 44
5.13.3 FT to PT arrangement . 44
ETSI
---------------------- Page: 4 ----------------------
5 ETSI EN 300 176-1 V2.4.1 (2022-11)
6 Test conditions, power sources and ambient temperatures . 45
6.1 General . 45
6.2 Nominal test conditions . 45
6.3 Extreme test conditions . 46
6.4 Test power source - general requirements . 47
6.5 Nominal test power source . 47
6.5.1 Mains voltage . 47
6.5.2 Regulated lead acid battery power sources . 47
6.5.3 Nickel cadmium or nickel metal hydride battery . 47
6.5.4 Other power sources . 47
6.6 Extreme test power source. 48
6.6.1 Mains voltage . 48
6.6.2 Regulated lead acid battery power sources . 48
6.6.3 Nickel cadmium or nickel metal hydride battery . 48
6.6.4 Other power sources . 48
6.7 Testing of host connected equipment and plug-in cards. 48
6.7.0 Approaches . 48
6.7.1 Alternative A: composite equipment . 48
6.7.2 Alternative B: use of a test jig and three hosts . 49
7 Accuracy and stability of RF carriers . 49
7.0 Requirements . 49
7.1 Definition . 49
7.2 Test environment . 50
7.3 Method of measurement . 50
7.4 Verdict criteria when the EUT is a RFP . 51
7.5 Verdict criteria when the EUT is a PP . 51
8 Accuracy and stability of timing parameters . 51
8.0 Requirements . 51
8.0.1 General . 51
8.0.2 Limits . 51
8.0.2.1 Reference timer accuracy and stability . 51
8.0.2.2 RFP transmission jitter . 51
8.0.2.3 PP reference timer synchronization . 52
8.1 Slot structure definitions . 52
8.2 Definition of the position of p0 . 52
8.3 Measurement of packet timing jitter . 52
8.3.1 Test environment . 52
8.3.2 Method of measurement . 53
8.3.3 Verdict criteria . 53
8.4 Measurement of the reference timing accuracy of a RFP . 53
8.4.1 Test environment . 53
8.4.2 Method of measurement . 53
8.4.3 Verdict criteria . 54
8.5 Measurement of packet transmission accuracy of a PP . 54
8.5.1 Test environment . 54
8.5.2 Method of measurement . 54
8.5.3 Verdict criteria . 55
9 Transmission burst . 55
9.0 Requirements . 55
9.0.1 General . 55
9.0.2 Limits .
...
Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
EUROPEAN STANDARD
Digital Enhanced Cordless Telecommunications (DECT);
Test specification;
Part 1: Radio
---------------------- Page: 1 ----------------------
2 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
Reference
REN/DECT-00365
Keywords
DECT, radio, regulation, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2022.
All rights reserved.
ETSI
---------------------- Page: 2 ----------------------
3 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
Contents
Intellectual Property Rights . 11
Foreword . 11
Modal verbs terminology . 12
1 Scope . 13
2 References . 13
2.1 Normative references . 13
2.2 Informative references . 14
3 Definition of terms, symbols and abbreviations . 15
3.1 Terms . 15
3.2 Symbols . 18
3.3 Abbreviations . 18
4 General . 20
4.1 Document layout . 20
4.1.1 Test suites . 20
4.1.2 Test groups. 20
4.1.3 Test cases . 21
4.2 Presentation of equipment for testing purposes . 21
4.2.0 General . 21
4.2.1 Choice of model for testing (if applicable) . 21
4.2.2 Description of equipment . 22
4.2.2.0 General . 22
4.2.2.1 Protocol Implementation Conformance Statement (PICS) . 22
4.2.2.2 Protocol Implementation eXtra Information for Testing (PIXIT) . 22
4.2.2.3 Environmental test conditions . 22
4.2.3 Host connected equipment . 22
4.2.4 Manufacturer's declaration . 23
4.3 Applicability of tests . 23
4.3.0 General . 23
4.3.1 Equipment that includes only a DECT RF receiver . 23
4.3.2 Equipment that includes a radio transmitter . 23
4.3.3 CTAs . 23
4.3.4 Equipment with a synchronization port . 23
4.3.5 Equipment incorporating the IPEI (PPs only) . 23
4.3.6 All FP equipment . 23
4.3.7 PPs with direct PP to PP communication option . 23
4.3.8 Installation related issues . 24
4.3.9 Equipment with combined FT and PT functionality . 24
4.3.9.0 General . 24
4.3.9.1 Wireless Relay Station . 24
4.3.9.2 Direct PP to PP communication . 24
4.3.9.3 Distributed communications . 24
4.3.10 Equipment that is capable of using higher level modulation . 25
4.3.11 Equipment supporting additional carriers . 25
4.4 Interpretation of the measurement results . 25
5 General test requirements . 25
5.1 Test philosophy . 25
5.2 Test site . 26
5.2.1 Open air test site . 26
5.2.1.1 Description . 26
5.2.1.2 Calibration . 27
5.2.2 Anechoic chamber . 28
5.2.2.1 General . 28
5.2.2.2 Description . 28
ETSI
---------------------- Page: 3 ----------------------
4 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
5.2.2.3 Influence of parasitic reflections . 31
5.2.2.4 Calibration and mode of use. 31
5.2.3 Stripline coupler . 31
5.2.3.0 General . 31
5.2.3.1 Description . 31
5.2.3.2 Calibration . 31
5.2.3.3 Mode of use . 31
5.3 Standard position . 32
5.4 Test antenna of the LT . 32
5.5 Substitution antenna . 32
5.6 Test fixture . 32
5.6.1 Description . 32
5.6.1.0 General . 32
5.6.1.1 Calibration of the test fixture for the measurement of transmitter characteristics . 33
5.6.1.2 Calibration of the test fixture for the measurement of receiver characteristics . 33
5.6.1.3 Mode of use . 34
5.6.2 Equipment with a temporary or internal permanent antenna connector. 34
5.6.2.0 General . 34
5.6.2.1 Equipment with a temporary antenna connector . 34
5.7 Indoor test site . 35
5.7.0 General . 35
5.7.1 Description . 35
5.7.2 Test for parasitic reflections. 36
5.7.3 Calibration and mode of use . 36
5.8 Lower Tester (LT) . 36
5.8.1 Description . 36
5.8.2 Connections between the EUT and the LT . 37
5.8.3 Functions and abilities . 37
5.8.4 Signal generation uncertainty . 38
5.8.4.0 General . 38
5.8.4.1 Modulated DECT-like carrier . 38
5.8.4.2 CW interferers . 38
5.8.4.3 DECT RF signal . 38
5.8.4.4 Test modulation signals . 38
5.8.5 Measurement uncertainty . 38
5.9 Upper Tester (UT) . 39
5.9.1 Description of the UT . 39
5.9.2 The test standby mode . 39
5.9.3 Test messages . 39
5.9.4 Dummy setting when EUT is a RFP and it is in test stand-by mode . 40
5.10 Description of the lower tester FT and PT . 40
5.11 General test methods . 40
5.11.1 General . 40
5.11.2 Sampling the RF signal . 40
5.11.2.1 Introduction . 40
5.11.2.2 Sampling method . 40
5.11.3 Determining the reference position . 40
5.11.3.0 General . 40
5.11.3.1 Case 1: EUTs that cannot transmit . 41
5.11.3.2 Case 2: EUTs that can transmit . 41
5.11.4 Bit Error Rate (BER) and Frame Error Ratio (FER) measurements . 41
5.12 Test setup. 41
5.12.0 General . 41
5.12.1 Test setup 1 . 41
5.12.2 Test setup 2 . 41
5.12.3 Test setup 3 . 42
5.12.4 Test setup 4 . 43
5.12.5 Void . 43
5.13 Test arrangements for intermodulation measurements . 43
5.13.1 PT to PT arrangement . 43
5.13.2 FT to FT arrangement . 44
5.13.3 FT to PT arrangement . 44
ETSI
---------------------- Page: 4 ----------------------
5 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
6 Test conditions, power sources and ambient temperatures . 45
6.1 General . 45
6.2 Nominal test conditions . 45
6.3 Extreme test conditions . 46
6.4 Test power source - general requirements . 47
6.5 Nominal test power source . 47
6.5.1 Mains voltage . 47
6.5.2 Regulated lead acid battery power sources . 47
6.5.3 Nickel cadmium or nickel metal hydride battery . 47
6.5.4 Other power sources . 47
6.6 Extreme test power source. 48
6.6.1 Mains voltage . 48
6.6.2 Regulated lead acid battery power sources . 48
6.6.3 Nickel cadmium or nickel metal hydride battery . 48
6.6.4 Other power sources . 48
6.7 Testing of host connected equipment and plug-in cards. 48
6.7.0 Approaches . 48
6.7.1 Alternative A: composite equipment . 48
6.7.2 Alternative B: use of a test jig and three hosts . 49
7 Accuracy and stability of RF carriers . 49
7.0 Requirements . 49
7.1 Definition . 49
7.2 Test environment . 50
7.3 Method of measurement . 50
7.4 Verdict criteria when the EUT is a RFP . 51
7.5 Verdict criteria when the EUT is a PP . 51
8 Accuracy and stability of timing parameters . 51
8.0 Requirements . 51
8.0.1 General . 51
8.0.2 Limits . 51
8.0.2.1 Reference timer accuracy and stability . 51
8.0.2.2 RFP transmission jitter . 51
8.0.2.3 PP reference timer synchronization . 52
8.1 Slot structure definitions . 52
8.2 Definition of the position of p0 . 52
8.3 Measurement of packet timing jitter . 52
8.3.1 Test environment . 52
8.3.2 Method of measurement . 53
8.3.3 Verdict criteria . 53
8.4 Measurement of the reference timing accuracy of a RFP . 53
8.4.1 Test environment . 53
8.4.2 Method of measurement . 53
8.4.3 Verdict criteria . 54
8.5 Measurement of packet transmission accuracy of a PP . 54
8.5.1 Test environment . 54
8.5.2 Method of measurement . 54
8.5.3 Verdict criteria . 55
9 Transmission burst . 55
9.0 Requirements . 55
9.0.1 General . 55
9
...
SLOVENSKI STANDARD
oSIST prEN 300 176-1 V2.3.8:2022
01-oktober-2022
Digitalne izboljšane brezvrvične telekomunikacije (DECT) - Specifikacija preskusa
- 1. del: Radio
Digital Enhanced Cordless Telecommunications (DECT) - Test specification - Part 1:
Radio
Ta slovenski standard je istoveten z: ETSI EN 300 176-1 V2.3.8 (2022-08)
ICS:
33.070.30 Digitalne izboljšane Digital Enhanced Cordless
brezvrvične telekomunikacije Telecommunications (DECT)
(DECT)
oSIST prEN 300 176-1 V2.3.8:2022 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
---------------------- Page: 2 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
EUROPEAN STANDARD
Digital Enhanced Cordless Telecommunications (DECT);
Test specification;
Part 1: Radio
---------------------- Page: 3 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
2 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
Reference
REN/DECT-00365
Keywords
DECT, radio, regulation, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2022.
All rights reserved.
ETSI
---------------------- Page: 4 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
3 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
Contents
Intellectual Property Rights . 11
Foreword . 11
Modal verbs terminology . 12
1 Scope . 13
2 References . 13
2.1 Normative references . 13
2.2 Informative references . 14
3 Definition of terms, symbols and abbreviations . 15
3.1 Terms . 15
3.2 Symbols . 18
3.3 Abbreviations . 18
4 General . 20
4.1 Document layout . 20
4.1.1 Test suites . 20
4.1.2 Test groups. 20
4.1.3 Test cases . 21
4.2 Presentation of equipment for testing purposes . 21
4.2.0 General . 21
4.2.1 Choice of model for testing (if applicable) . 21
4.2.2 Description of equipment . 22
4.2.2.0 General . 22
4.2.2.1 Protocol Implementation Conformance Statement (PICS) . 22
4.2.2.2 Protocol Implementation eXtra Information for Testing (PIXIT) . 22
4.2.2.3 Environmental test conditions . 22
4.2.3 Host connected equipment . 22
4.2.4 Manufacturer's declaration . 23
4.3 Applicability of tests . 23
4.3.0 General . 23
4.3.1 Equipment that includes only a DECT RF receiver . 23
4.3.2 Equipment that includes a radio transmitter . 23
4.3.3 CTAs . 23
4.3.4 Equipment with a synchronization port . 23
4.3.5 Equipment incorporating the IPEI (PPs only) . 23
4.3.6 All FP equipment . 23
4.3.7 PPs with direct PP to PP communication option . 23
4.3.8 Installation related issues . 24
4.3.9 Equipment with combined FT and PT functionality . 24
4.3.9.0 General . 24
4.3.9.1 Wireless Relay Station . 24
4.3.9.2 Direct PP to PP communication . 24
4.3.9.3 Distributed communications . 24
4.3.10 Equipment that is capable of using higher level modulation . 25
4.3.11 Equipment supporting additional carriers . 25
4.4 Interpretation of the measurement results . 25
5 General test requirements . 25
5.1 Test philosophy . 25
5.2 Test site . 26
5.2.1 Open air test site . 26
5.2.1.1 Description . 26
5.2.1.2 Calibration . 27
5.2.2 Anechoic chamber . 28
5.2.2.1 General . 28
5.2.2.2 Description . 28
ETSI
---------------------- Page: 5 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
4 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
5.2.2.3 Influence of parasitic reflections . 31
5.2.2.4 Calibration and mode of use. 31
5.2.3 Stripline coupler . 31
5.2.3.0 General . 31
5.2.3.1 Description . 31
5.2.3.2 Calibration . 31
5.2.3.3 Mode of use . 31
5.3 Standard position . 32
5.4 Test antenna of the LT . 32
5.5 Substitution antenna . 32
5.6 Test fixture . 32
5.6.1 Description . 32
5.6.1.0 General . 32
5.6.1.1 Calibration of the test fixture for the measurement of transmitter characteristics . 33
5.6.1.2 Calibration of the test fixture for the measurement of receiver characteristics . 33
5.6.1.3 Mode of use . 34
5.6.2 Equipment with a temporary or internal permanent antenna connector. 34
5.6.2.0 General . 34
5.6.2.1 Equipment with a temporary antenna connector . 34
5.7 Indoor test site . 35
5.7.0 General . 35
5.7.1 Description . 35
5.7.2 Test for parasitic reflections. 36
5.7.3 Calibration and mode of use . 36
5.8 Lower Tester (LT) . 36
5.8.1 Description . 36
5.8.2 Connections between the EUT and the LT . 37
5.8.3 Functions and abilities . 37
5.8.4 Signal generation uncertainty . 38
5.8.4.0 General . 38
5.8.4.1 Modulated DECT-like carrier . 38
5.8.4.2 CW interferers . 38
5.8.4.3 DECT RF signal . 38
5.8.4.4 Test modulation signals . 38
5.8.5 Measurement uncertainty . 38
5.9 Upper Tester (UT) . 39
5.9.1 Description of the UT . 39
5.9.2 The test standby mode . 39
5.9.3 Test messages . 39
5.9.4 Dummy setting when EUT is a RFP and it is in test stand-by mode . 40
5.10 Description of the lower tester FT and PT . 40
5.11 General test methods . 40
5.11.1 General . 40
5.11.2 Sampling the RF signal . 40
5.11.2.1 Introduction . 40
5.11.2.2 Sampling method . 40
5.11.3 Determining the reference position . 40
5.11.3.0 General . 40
5.11.3.1 Case 1: EUTs that cannot transmit . 41
5.11.3.2 Case 2: EUTs that can transmit . 41
5.11.4 Bit Error Rate (BER) and Frame Error Ratio (FER) measurements . 41
5.12 Test setup. 41
5.12.0 General . 41
5.12.1 Test setup 1 . 41
5.12.2 Test setup 2 . 41
5.12.3 Test setup 3 . 42
5.12.4 Test setup 4 . 43
5.12.5 Void . 43
5.13 Test arrangements for intermodulation measurements . 43
5.13.1 PT to PT arrangement . 43
5.13.2 FT to FT arrangement . 44
5.13.3 FT to PT arrangement . 44
ETSI
---------------------- Page: 6 ----------------------
oSIST prEN 300 176-1 V2.3.8:2022
5 Draft ETSI EN 300 176-1 V2.3.8 (2022-08)
6 Test conditions, power sources and ambient temperatures . 45
6.1 General . 45
6.2 Nominal test conditions . 45
6.3 Extreme test conditions . 46
6.4 Test power source - general requirements . 47
6.5 Nominal test power source . 47
6.5.1 Mains voltage . 47
6.5.2 Regulated lead acid battery power sources . 47
6.5.3 Nickel cadmium or nickel metal hydride battery . 47
6.5.4 Other power sources . 47
6.6 Extreme test power source. 48
6.6.1 Mains voltage . 48
6.6.2 Regulated lead acid battery power sources . 48
6.6.3 Nickel cadmium or nickel metal hydride battery . 48
6.6.4 Other power sources . 48
6.7 Testing of host connected equipment and plug-in cards. 48
6.7.0 Approaches . 48
6.7.1 Alternative A: composite equipment . 48
6.7.2 Alternative B: use of a test jig and three hosts . 49
7 Accuracy and stability of RF carriers . 49
7.0 Requirements . 49
7.1 Definition . 49
7.2 Test environment . 50
7.3 Method of measurement . 50
7.4 Verdict criteria when the EUT is a RFP . 51
7.5 Verdict criteria when the EUT is a PP . 51
8 Accuracy and stability of timing parameters . 51
8.0 Requirements . 51
8.0.1 General . 51
8.0.2 Limits . 51
8.0.2.1 Reference timer accuracy and stability . 51
8.0.2.2 RFP transmission jitter . 51
8.0.2.3 PP reference timer synchronization . 52
8.1 Slot structure definitions . 52
8.2 Definition of the position of p0 . 52
8.3 Measurement of packet timing jitter . 52
8.3.1 Test environment . 52
8.3.2 Method of measurement . 53
8.3.3 Verdict criteria . 53
8.4 Measurement of the reference timing accuracy of a RFP . 53
8.4.1 Test environment . 53
8.4.2 Method of measurement . 53
8.4.3 Verdict criteria . 54
8.5 Measurement of packet transmission accuracy of a PP . 54
8.5.1 Test environment .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.