Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 1-1: Generic processes and performance

REN/TM-01015-1-1a

Prenos in multipleksiranje (TM) – Generične zahteve za prenosno funkcionalnost opreme – 1-1. del: Generični procesi in lastnosti

General Information

Status
Published
Publication Date
09-May-1999
Current Stage
12 - Completion
Due Date
07-May-1999
Completion Date
10-May-1999

Buy Standard

Standard
EN 300 417-1-1 V1.1.3:2003
English language
112 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.XQNFLRQDOQRVWTransmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 1-1: Generic processes and performance33.040.20Prenosni sistemTransmission systemsICS:Ta slovenski standard je istoveten z:EN 300 417-1-1 Version 1.1.3SIST EN 300 417-1-1 V1.1.3:2003en01-december-2003SIST EN 300 417-1-1 V1.1.3:2003SLOVENSKI
STANDARD



SIST EN 300 417-1-1 V1.1.3:2003



EN 300 417-1-1 V1.1.3 (1999-05)European Standard (Telecommunications series)Transmission and Multiplexing (TM);Generic requirements of transport functionality of equipment;Part 1-1: Generic processes and performanceSIST EN 300 417-1-1 V1.1.3:2003



ETSIEN 300 417-1-1 V1.1.3 (1999-05)2ReferenceREN/TM-01015-1-1a (3v099ie0.PDF)KeywordsSDH, transmission, equipment practice,performanceETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frCopyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 300 417-1-1 V1.1.3:2003



ETSIEN 300 417-1-1 V1.1.3 (1999-05)3ContentsIntellectual Property Rights.7Foreword.71Scope.92References.103Abbreviations, definitions, naming and numbering conventions.113.1Abbreviations.113.2Definitions.163.3Naming and numbering conventions.193.3.1Bit numbering scheme.193.3.2STM-N SOH byte numbering scheme.193.3.3Atomic function naming scheme.193.3.4Information naming scheme.203.3.5AU/TU numbering scheme.203.3.6Reference points numbering scheme.233.3.7Tributary port numbering scheme.233.3.8PU numbering scheme.243.3.9Supervision variables numbering scheme.253.4Symbols and diagrammatic conventions.254Introduction.274.1Functional modelling rationale.284.1.1Description of network elements - equipment functional specification.284.1.2Implementation independence.284.1.3Universal representation for management.284.2The underlying principles of functional modelling.294.2.1The client-server relationship.294.2.2Atomic functions and compound functions.294.2.3Network functions included in specific equipment.294.2.4The functional model and the information model.295Network layering principles.305.1Transmission layers.305.2Atomic functions.315.2.1Connection function.325.2.2Trail termination function.335.2.3Adaptation function.345.3Reference points.355.4Transmission sub-layers.356Combination rules.366.1General.366.1.1Binding at connection points.366.1.2Binding at (termination) connection points.366.1.3Binding at APs.376.1.4Alternative binding representations.376.2Directionality.376.3Compound functions.386.4Major compound functions.386.5Trail, (sub)network connections, link connections, matrix connections, and tandem connections.396.6Matrix connections.396.6.11-port.406.6.22-port.406.6.33-port.416.6.44-port.42SIST EN 300 417-1-1 V1.1.3:2003



ETSIEN 300 417-1-1 V1.1.3 (1999-05)47Maintenance signals and processes.427.1Trail Trace Identifier (TTI).427.2Trail Signal Label (TSL).447.2.1Unequipped signal application.447.2.2Supervisory-unequipped signal application.457.2.3Adaptation function selection supervision process.467.2.4Connection monitoring application.477.3Error Detection Code (EDC).477.4Remote indicators.477.4.1Remote Defect Indicator (RDI).477.4.2Remote Error Indicator (REI).487.5Alarm Indication Signal (AIS).497.6Non-intrusive monitoring of characteristic information at connection points.527.7Signal fail and signal degrade.537.7.1Server Signal Fail (aSSF) signal.537.7.2Server Signal Fail failure (fSSF).537.7.3Server Signal Degrade (aSSD) signal.537.7.4Trail Signal Fail (aTSF) signal.537.7.5Trail Signal Degrade (aTSD) signal.548Supervision process.548.1Introduction.548.2Atomic function fault management.568.2.1Defect filter f1.578.2.1.1Introduction.578.2.1.2Trail Signal Label (TSL) and unequipped.578.2.1.3Trail Trace Identifier (TTI).598.2.1.4Degraded (DEG).608.2.1.5Remote Defect Indicator (RDI).608.2.1.6Loss of signal.618.2.1.7Alarm Indication Signal (AIS).618.2.1.8Loss of frame, multiframe, pointer.628.2.1.9Failure of protocol.628.2.1.10Equipment defects.628.2.1.11Transmit Fail.628.2.2Consequent action filter f2.628.2.2.1Alarm Indication Signal (AIS).648.2.2.2Remote Defect Indicator (RDI).658.2.2.3Remote Error Indication (REI).658.2.2.4Server Signal Fail (SSF).658.2.2.5Trail Signal Fail (TSF).668.2.2.6Trail Signal Degrade (TSD).668.2.2.7Unequipped Virtual Container (VC) signal.668.2.2.8Unit Failure (UF).668.2.2.9(Automatic) laser shutdown (ALS/LS).668.2.2.10Server Signal Degrade (SSD).678.2.3Fault cause filter f3.678.2.3.1Termination sink function.678.2.3.2Termination supervisory sink function.688.2.3.3Adaptation sink function.688.2.3.4Connection function.688.2.4Performance monitoring filter f11 (pN_EBC).698.2.5Performance monitoring filter f12 (pN_DS).698.2.6Performance monitoring filter f21 (pF_EBC).698.2.7Performance monitoring filter f22 (pF_DS).698.2.8Other performance monitoring parameters (pOFS, pPSC, pPJE).698.3Equipment management function fault management process.708.3.1Failure filter f4.708.3.2Replaceable unit alarm filter f5.708.3.3Network element alarm filter f6.718.3.4Station alarm filter f7.71SIST EN 300 417-1-1 V1.1.3:2003



ETSIEN 300 417-1-1 V1.1.3 (1999-05)58.3.5Failure report filter f8.718.4Equipment Management Function (EMF) performance monitoring process.718.4.1PM filter f13 (N_ES).728.4.2PM filter f23 (F_ES).728.4.3PM filter f14 (N_SES).728.4.4PM filter f24 (F_SES).738.4.5PM filter f15 (N_UAT_cmd).738.4.6PM filter f25 (F_UAT_cmd).738.4.7PM filter f16 (N_BBE).738.4.8PM filter f26 (F_BBE).738.4.9PM filter f31 (history management).738.5Trail termination point mode and port mode.749Protection process.759.1Introduction.759.2General.759.2.1Protection architectures.779.2.2Switching types.789.2.2.1APS channel provisioning.789.2.2.2APS channel usage.789.2.2.3APS channel coding.799.2.3Operation types.799.2.4Protection switch requests.799.2.5Protection switch performance.799.2.6Protection switch state machine.799.2.7Protection connection function (I/O and processes).809.3Trail protection class.809.3.1Linear trail protection.809.3.2SPRING protection.829.3.3DPRING protection.849.4SNC protection class.859.4.1Inherently monitored SNC (SNC/I) protection.859.4.2Non-intrusively monitored SNC (SNC/N) protection.869.4.3Tandem connection protection.869.5Equipment protection.8610Timing processes.8710.1Introduction.8710.2Synchronization timing collection.8710.2.1External synchronization reference inputs.8810.2.2Internal synchronization reference input.8810.3Synchronization timing selection and processing.8810.3.1Synchronization reference source selection.8810.3.2Clock processing.8810.4Synchronization timing distribution.8910.4.1Internal synchronization distribution interfaces.8910.4.2Synchronization reference outputs.8910.5Inter atomic function timing.8910.6AIS timing.9011General performance.9111.1Availability objectives.9111.1.1General.9111.1.2Parameters.9111.1.3Derivation of MTBF values.9211.2Transfer delay.9211.3Jitter and wander.9311.3.1Jitter and wander generation.9311.3.1.1Jitter and wander generation on STM-N signals.9311.3.1.2Jitter and wander generation on PDH interfaces.9311.3.1.3Jitter and wander generation on 2 048 kHz or 2 048 kbit/s synchronization interfaces.95SIST EN 300 417-1-1 V1.1.3:2003



ETSIEN 300 417-1-1 V1.1.3 (1999-05)611.3.2Jitter and wander tolerance.9511.3.2.1Jitter and wander tolerance on optical interfaces.9511.3.2.2Jitter and wander tolerance on traffic carrying electrical interfaces.9511.3.2.3Jitter and wander tolerance on 2 048 kHz and 2 048 kbit/s synchronization interfaces.9511.3.3Jitter and wander transfer functions.9611.3.4Performance on synchronization reference change-over.9611.4Error performance.9611.5Blocking factor.9611.6Connection set-up time.96Annex A (normative):Pointer generation.97Annex B (normative):Pointer interpretation.99Annex C (informative):Network "production rules".103Annex D (informative):Flexible assignment of tributary port to VC-12 capacity.105Annex E (informative):Relationship between TU-2/12 address, and location of columnswithin a VC-4.106Annex F (informative):Performance monitoring history process.108Annex G (informative):Protection switch examples.110Bibliography.111History.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.