Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 2: Data Link Control (DLC) layer - Portable radio Termination (PT)

DE/RES-03042-2

Digitalne izboljšane brezvrvične telekomunikacije (DECT) - Skupni vmesnik (CI) - Proforma izjave o skladnosti izvedbe protokola (PICS) - 2. del: Plast krmiljenja podatkovnih povezav (DLC) - prenosna radijska zaključitev (PT)

General Information

Status
Published
Publication Date
27-Aug-1996
Technical Committee
Current Stage
12 - Completion
Due Date
06-Sep-1996
Completion Date
28-Aug-1996
Mandate

Buy Standard

Standard
P ETS 300 476-2:1999
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ETS 300 476-2:1999
English language
52 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 2: Data Link Control (DLC) layer - Portable radio Termination (PT)33.070.30'(&7Digital Enhanced Cordless Telecommunications (DECT)ICS:Ta slovenski standard je istoveten z:ETS 300 476-2 E13SIST ETS 300 476-2:1999en01-jDQXDU-19993SIST ETS 300 476-2:1999SLOVENSKI
STANDARD



SIST ETS 300 476-2:1999



EUROPEANETS 300 476-2TELECOMMUNICATIONAugust 1996STANDARDSource: ETSI TC-RESReference: DE/RES-03042-2ICS:33.020, 33.060.50Key words:DECT, CI, PICSRadio Equipment and Systems (RES);Digital Enhanced Cordless Telecommunications (DECT);Common Interface (CI);Protocol Implementation Conformance Statement (PICS)proforma;Part 2: Data Link Control (DLC) layer -Portable radio Termination (PT)ETSIEuropean Telecommunications Standards InstituteETSI SecretariatPostal address: F-06921 Sophia Antipolis CEDEX - FRANCEOffice address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCEX.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.frTel.: +33 92 94 42 00 - Fax: +33 93 65 47 16Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and theforegoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1996. All rights reserved.SIST ETS 300 476-2:1999



Page 2ETS 300 476-2: August 1996Whilst every care has been taken in the preparation and publication of this document, errors in content,typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to"ETSI Editing and Committee Support Dept." at the address shown on the title page.SIST ETS 300 476-2:1999



Page 3ETS 300 476-2: August 1996ContentsForeword.91Scope.112Normative references.113Definitions, symbols and abbreviations.123.1Definitions.123.2Abbreviations.124Conformance requirement to this PICS proforma specification.12Annex A (normative):PICS Proforma for DECT DLC PT.13A.1Introduction for completing the PICS proforma.13A.1.1Purposes and structure.13A.1.2Guidances for completing the PICS.15A.2Identification of the implementation.16A.2.1Date of statement.16A.2.2Implementation Under Test (IUT) identification.16A.2.3System Under Test (SUT) identification.16A.2.4Product supplier.16A.2.5Client identification.17A.2.6Contact person.17A.3Identification of the protocol.17A.4Global statement of conformance.18A.5Capabilities.18A.5.1Major capabilities.18A.5.1.1Services.18A.5.1.2Procedures.19A.5.1.2.1Generic signalling procedures.19A.5.1.2.2Class U procedures.19A.5.1.2.3Class A procedures.19A.5.1.2.4Class B procedures.20A.5.1.2.5Broadcast procedures.20A.5.1.2.6LU1 procedures.20A.5.1.2.7LU2 procedures.21A.5.1.2.8LU5 protected data procedures.21A.5.1.2.9LU5 unprotected data procedures.22A.5.1.2.10LU7 procedures.22A.5.1.2.11Management procedures.23A.5.2Protocol parameters.24A.5.2.1C-plane timers.24A.5.2.2U-plane timers.24A.5.2.3Class A parameters.25A.5.2.4Class B parameters.25A.5.2.5LU1 parameters.25A.5.2.6LU2 parameters.25A.5.2.7LU5 parameters.26A.5.2.8LU7 parameters.27A.5.3Protocol PDUs.27A.5.3.1C-plane PDUs.27SIST ETS 300 476-2:1999



Page 4ETS 300 476-2: August 1996A.5.3.1.1C-plane frame structure.27A.5.3.1.2C-plane messages.28A.5.3.1.2.1Message support.28A.5.3.1.2.2Class A I-command.29A.5.3.1.2.3Class A RR command/response.31A.5.3.1.2.4Class B I-command.32A.5.3.1.2.5Class B RR command/response.33A.5.3.1.2.6Class B RNR command/response.34A.5.3.1.2.7Class B REJ command/response.35A.5.3.1.2.8Class B SABM command.37A.5.3.1.2.9Class B DM response.38A.5.3.1.2.10Class B DISC command.39A.5.3.1.2.11Class B UA response.40A.5.3.1.2.12Class U UI command.41A.5.3.2U-plane PDUs.43A.5.3.2.1FU1 frame structure.43A.5.3.2.2FU4 frame structure.44A.5.3.2.3FU5 frame structure.45A.5.3.2.4FU6a frame structure.47A.5.3.2.5FU6b frame structure.48A.5.3.2.6FU7 frame structure.49A.5.4Protocol error handling.51A.5.4.1General error handling.51A.5.4.2Class A error handling and recovery.51A.5.4.3Class B error handling and recovery.51History.52QuestionsTable A.1 Date of Statement.16Table A.2 IUT identification.16Table A.3 SUT identification.16Table A.4 Product supplier.16Table A.5 Client.17Table A.6 Contact person.17Table A.7 Identification of protocol.17Table A.8 Global statement of conformance.18Table A.9 Data link services.18Table A.10 C-plane services.18Table A.11 U-plane services.18Table A.12 Management services.19Table A.13 Generic signalling procedures.19Table A.14 Class U procedures.19Table A.15 Class A procedures.19Table A.16 Class B procedures.20Table A.17 Broadcast procedures.20Table A.18 LU1 procedures.20Table A.19 FU1 options.20Table A.20 LU2 procedures.21Table A.21 FU4 options.21Table A.22 FU5 options.21Table A.23 FU6 options.21Table A.24 LU5 protected data procedures.21Table A.25 LU5 unprotected data procedures.22Table A.26 LU7 procedures.22Table A.27 LU7 establishment and synchronisation procedures.22Table A.28 LU7 active phase procedures.22Table A.29 LU7 exceptional procedures.23SIST ETS 300 476-2:1999



Page 5ETS 300 476-2: August 1996Table A.30 Management procedures.23Table A.31 MAC connection management procedures.23Table A.32 DLC C-plane management procedures.23Table A.33 DLC U-plane management procedures.24Table A.34 Connection ciphering management procedures.24Table A.35 C-plane timers.24Table A.36 U-plane timers.24Table A.37 Class A parameter values.25Table A.38 Class B parameter values.25Table A.39 LU1 Frame types.25Table A.40 LU1 Connection types.25Table A.41 LU2 Frame types.25Table A.42 LU2 Connection types.26Table A.43 LU2 Transmission classes.26Table A.44 LU5 Frame types.26Table A.45 LU5 Connection types.26Table A.46 LU5 Transmission classes.27Table A.47 LU7 Frame types.27Table A.48 LU7 Connection types.27Table A.49 LU7 Transmission classes.27Table A.50 Frame structures (Sending P to F).27Table A.51 Frame structures (Receipt F to P).27Table A.52 Frame format type FA (Sending P to F).28Table A.53 Frame format type FA (Receipt F to P).28Table A.54 Broadcast service frame structure (Receipt F to P).28Table A.55 Class A messages support (Sending P to F).28Table A.56 Class A messages support (Receipt F to P).28Table A.57 Class B messages support (Sending P to F).29Table A.58 Class B messages support (Receipt F to P).29Table A.59 Class U messages support (Sending P to F).29Table A.60 Class U messages support (Receipt F to P).29Table A.61 Class A I-command (Numbered Information) (Sending P to F).29Table A.62 Class A I-command (Numbered Information) (Receipt F to P).30Table A.63 Class A I-command Control field (Sending P to F).30Table A.64 Class A I-command Control field (Receipt F to P).30Table A.65 Class A I-command Address field (Sending P to F).30Table A.66. Class A I-command Address field (Receipt F to P).30Table A.67 Class A RR-command/response (Receive ready) (Sending P to F).31Table A.68 Class A RR-command/response (Receive ready) (Receipt F to P).31Table A.69 Class A RR Control field (Sending P to F).31Table A.70 Class A RR Control field (Receipt F to P).31Table A.71 Class A RR Address field (Sending P to F).31Table A.72 Class A RR Address field (Receipt F to P).32Table A.73 Class B I-command (Numbered Information) (Sending P to F).32Table A.74 Class B I-command (Numbered Information) (Receipt F to P).32Table A.75 Class B I-command Control field (Sending P to F).32Table A.76 Class B I-command Control field (Receipt F to P).32Table A.77 Class B I-command Address field (Sending P to F).33Table A.78 Class B I-command Address field (Receipt F to P).33Table A.79 Class B RR-command/response (Receive ready) (Sending P to F).33Table A.80 Class B RR-command/response (Receive ready) (Receipt F to P).33Table A.81 Class B RR Control field (Sending P to F).33Table A.82 Class B RR Control field (Receipt F to P).34Table A.83 Class B RR Address field (Sending P to F).34Table A.84 Class B RR Address field (Receipt F to P).34Table A.85 Class B RNR command/response (Receive Not Ready) (Sending P to F).34Table A.86 Class B RNR command/response (Receive Not Ready) (Receipt F to P).34Table A.87 Class B RNR Control field (Sending P to F).35Table A.88 Class B RNR Control field (Receipt F to P).35Table A.89 Class B RNR Address field (Sending P to F).35Table A.90 Class B RNR Address field (Receipt F to P).35Table A.91 Class B REJ command/response (Reject) (Sending P to F).35Table A.92 Class B REJ command/response (Reject) (Receipt F to P).36SIST ETS 300 476-2:1999



Page 6ETS 300 476-2: August 1996Table A.93 Class B REJ Control field (Sending P to F).36Table A.94 Class B REJ Control field (Receipt F to P).36Table A.95 Class B REJ Address field (Sending P to F).36Table A.96 Class B REJ Address field (Receipt F to P).36Table A.97 Class B SABM command (Sending P to F).37Table A.98 Class B SABM command (Receipt F to P).37Table A.99 Class B SABM Control field (Sending P to F).37Table A.100 Class B SABM Control field (Receipt F to P).37Table A.101 Class B SABM Address field (Sending P to F).37Table A.102 Class B SABM Address field (Receipt F to P).38Table A.103 Class B DM-response (Disconnect Mode) (Sending P to F).38Table A.104 Class B DM-response (Disconnect Mode) (Receipt F to P).38Table A.105 Class B DM Control field (Sending P to F).38Table A.106 Class B DM Control field (Receipt F to P).38Table A.107 Class B DM Address field (Sending P to F).39Table A.108 Class B DM Address field (Receipt F to P).39Table A.109 Class B DISC command (Disconnect) (Sending P to F).39Table A.110 Class B DISC command (Disconnect) (Receipt F to P).39Table A.111 Class B DISC Control field (Sending P to F).39Table A.112 Class B DISC Control field (Receipt F to P).40Table A.113 Class B DISC Address field (Sending P to F).40Table A.114 Class B DISC Address field (Receipt F to P).40Table A.115 Class B UA-response (Unnumbered ACK) (Sending P to F).40Table A.116 Class B UA-response (Unnumbered ACK) (Receipt F to P).40Table A.117 Class B UA Control field (Sending P to F).41Table A.118 Class B UA Control field (Receipt F to P).41Table A.119 Class B UA Address field (Sending P to F).41Table A.120 Class B UA Address field (Receipt F to P).41Table A.121 Class U UI command (Unnumbered Information) (Sending P to F).41Table A.122 Class U UI command (Unnumbered Information) (Receipt F to P).42Table A.123 Class U UI Control field (Sending P to F).42Table A.124 Class U UI Control field (Receipt F to P).42Table A.125 Class U UI Address field (Sending P to F).42Table A.126 Class U UI Address field (Receipt F to P).42Table A.127 U-plane frames (Sending P to F).43Table A.128 U-plane frames (Receipt F to P).43Table A.129 FU1 frame structure (Sending P to F).43Table A.130 FU1 frame structure (Receipt F to P).43Table A.131 FU4 frame structure (Sending P to F).44Table A.132 FU4 frame structure (Receipt F to P).44Table A.133 FU4 Length indicator field (Sending P to F).44Table A.134 FU4 Length indicator field (Receipt F to P).44Table A.135 FU4 Send sequence number (Sending P to F).44Table A.136 FU4 Send sequence number (Receipt F to P).44Table A.137 FU4 Receive sequence number (Sending P to F).45Table A.138 FU4 Receive sequence number (Receipt F to P).45Table A.139 FU5 frame structure (Sending P to F).45Table A.140 FU5 frame structure (Receipt F to P).45Table A.141 FU5 Address field (Sending P to F).45Table A.142 FU5 Address field (Receipt F to P).46Table A.143 FU5 Length indicator field (Sending P to F).46Table A.144 FU5 Length indicator field (Receipt F to P).46Table A.145 FU5 Send sequence number (Sending P to F).46Table A.146 FU5 Send sequence number (Receipt F to P).46Table A.147 FU5 Receive sequence number (Sending P to F).46Table A.148 FU5 Receive sequence number (Receipt F to P).47Table A.149 FU6a frame structure (Sending P to F).47Table A.150 FU6a frame structure (Receipt F to P).47Table A.151 FU6a Length indicator field (Sending P to F).47Table A.152 FU6a Length indicator field (Receipt F to P).47Table A.153 FU6a Send sequence number (Sending P to F).47Table A.154 FU6a Send sequence number (Receipt F to P).48Table A.155 FU6b frame structure (Sending P to F).48SIST ETS 300 476-2:1999



Page 7ETS 300 476-2: August 1996Table A.156 FU6b frame structure (Receipt F to P).48Table A.157 FU6b Receive sequence number (Sending P to F).48Table A.158 FU6b Receive sequence number (Receipt F to P).48Table A.159 FU7 64 kbit/s frame structure (Sending P to F).49Table A.160 FU7 64 kbit/s frame structure (Receipt F to P).49Table A.161 FU7 64 kbit/s control field (Sending P to F).49Table A.162 FU7 64 kbit/s control field (Receipt F to P).50Table A.163 FU7 72 kbit/s frame structure (Sending P to F).50Table A.164 FU7 72 kbit/s frame structure (Receipt F to P).50Table A.165 FU7 72 kbit/s control field (Sending P to F).
...

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 2: Data Link Control (DLC) layer - Portable radio Termination (PT)33.070.30'(&7Digital Enhanced Cordless Telecommunications (DECT)ICS:Ta slovenski standard je istoveten z:ETS 300 476-2 Edition 1SIST ETS 300 476-2:1999en01-maj-1999SIST ETS 300 476-2:1999SLOVENSKI
STANDARD



SIST ETS 300 476-2:1999



EUROPEANETS 300 476-2TELECOMMUNICATIONAugust 1996STANDARDSource: ETSI TC-RESReference: DE/RES-03042-2ICS:33.020, 33.060.50Key words:DECT, CI, PICSRadio Equipment and Systems (RES);Digital Enhanced Cordless Telecommunications (DECT);Common Interface (CI);Protocol Implementation Conformance Statement (PICS)proforma;Part 2: Data Link Control (DLC) layer -Portable radio Termination (PT)ETSIEuropean Telecommunications Standards InstituteETSI SecretariatPostal address: F-06921 Sophia Antipolis CEDEX - FRANCEOffice address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCEX.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.frTel.: +33 92 94 42 00 - Fax: +33 93 65 47 16Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and theforegoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1996. All rights reserved.SIST ETS 300 476-2:1999



Page 2ETS 300 476-2: August 1996Whilst every care has been taken in the preparation and publication of this document, errors in content,typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to"ETSI Editing and Committee Support Dept." at the address shown on the title page.SIST ETS 300 476-2:1999



Page 3ETS 300 476-2: August 1996ContentsForeword.91Scope.112Normative references.113Definitions, symbols and abbreviations.123.1Definitions.123.2Abbreviations.124Conformance requirement to this PICS proforma specification.12Annex A (normative):PICS Proforma for DECT DLC PT.13A.1Introduction for completing the PICS proforma.13A.1.1Purposes and structure.13A.1.2Guidances for completing the PICS.15A.2Identification of the implementation.16A.2.1Date of statement.16A.2.2Implementation Under Test (IUT) identification.16A.2.3System Under Test (SUT) identification.16A.2.4Product supplier.16A.2.5Client identification.17A.2.6Contact person.17A.3Identification of the protocol.17A.4Global statement of conformance.18A.5Capabilities.18A.5.1Major capabilities.18A.5.1.1Services.18A.5.1.2Procedures.19A.5.1.2.1Generic signalling procedures.19A.5.1.2.2Class U procedures.19A.5.1.2.3Class A procedures.19A.5.1.2.4Class B procedures.20A.5.1.2.5Broadcast procedures.20A.5.1.2.6LU1 procedures.20A.5.1.2.7LU2 procedures.21A.5.1.2.8LU5 protected data procedures.21A.5.1.2.9LU5 unprotected data procedures.22A.5.1.2.10LU7 procedures.22A.5.1.2.11Management procedures.23A.5.2Protocol parameters.24A.5.2.1C-plane timers.24A.5.2.2U-plane timers.24A.5.2.3Class A parameters.25A.5.2.4Class B parameters.25A.5.2.5LU1 parameters.25A.5.2.6LU2 parameters.25A.5.2.7LU5 parameters.26A.5.2.8LU7 parameters.27A.5.3Protocol PDUs.27A.5.3.1C-plane PDUs.27SIST ETS 300 476-2:1999



Page 4ETS 300 476-2: August 1996A.5.3.1.1C-plane frame structure.27A.5.3.1.2C-plane messages.28A.5.3.1.2.1Message support.28A.5.3.1.2.2Class A I-command.29A.5.3.1.2.3Class A RR command/response.31A.5.3.1.2.4Class B I-command.32A.5.3.1.2.5Class B RR command/response.33A.5.3.1.2.6Class B RNR command/response.34A.5.3.1.2.7Class B REJ command/response.35A.5.3.1.2.8Class B SABM command.37A.5.3.1.2.9Class B DM response.38A.5.3.1.2.10Class B DISC command.39A.5.3.1.2.11Class B UA response.40A.5.3.1.2.12Class U UI command.41A.5.3.2U-plane PDUs.43A.5.3.2.1FU1 frame structure.43A.5.3.2.2FU4 frame structure.44A.5.3.2.3FU5 frame structure.45A.5.3.2.4FU6a frame structure.47A.5.3.2.5FU6b frame structure.48A.5.3.2.6FU7 frame structure.49A.5.4Protocol error handling.51A.5.4.1General error handling.51A.5.4.2Class A error handling and recovery.51A.5.4.3Class B error handling and recovery.51History.52QuestionsTable A.1 Date of Statement.16Table A.2 IUT identification.16Table A.3 SUT identification.16Table A.4 Product supplier.16Table A.5 Client.17Table A.6 Contact person.17Table A.7 Identification of protocol.17Table A.8 Global statement of conformance.18Table A.9 Data link services.18Table A.10 C-plane services.18Table A.11 U-plane services.18Table A.12 Management services.19Table A.13 Generic signalling procedures.19Table A.14 Class U procedures.19Table A.15 Class A procedures.19Table A.16 Class B procedures.20Table A.17 Broadcast procedures.20Table A.18 LU1 procedures.20Table A.19 FU1 options.20Table A.20 LU2 procedures.21Table A.21 FU4 options.21Table A.22 FU5 options.21Table A.23 FU6 options.21Table A.24 LU5 protected data procedures.21Table A.25 LU5 unprotected data procedures.22Table A.26 LU7 procedures.22Table A.27 LU7 establishment and synchronisation procedures.22Table A.28 LU7 active phase procedures.22Table A.29 LU7 exceptional procedures.23SIST ETS 300 476-2:1999



Page 5ETS 300 476-2: August 1996Table A.30 Management procedures.23Table A.31 MAC connection management procedures.23Table A.32 DLC C-plane management procedures.23Table A.33 DLC U-plane management procedures.24Table A.34 Connection ciphering management procedures.24Table A.35 C-plane timers.24Table A.36 U-plane timers.24Table A.37 Class A parameter values.25Table A.38 Class B parameter values.25Table A.39 LU1 Frame types.25Table A.40 LU1 Connection types.25Table A.41 LU2 Frame types.25Table A.42 LU2 Connection types.26Table A.43 LU2 Transmission classes.26Table A.44 LU5 Frame types.26Table A.45 LU5 Connection types.26Table A.46 LU5 Transmission classes.27Table A.47 LU7 Frame types.27Table A.48 LU7 Connection types.27Table A.49 LU7 Transmission classes.27Table A.50 Frame structures (Sending P to F).27Table A.51 Frame structures (Receipt F to P).27Table A.52 Frame format type FA (Sending P to F).28Table A.53 Frame format type FA (Receipt F to P).28Table A.54 Broadcast service frame structure (Receipt F to P).28Table A.55 Class A messages support (Sending P to F).28Table A.56 Class A messages support (Receipt F to P).28Table A.57 Class B messages support (Sending P to F).29Table A.58 Class B messages support (Receipt F to P).29Table A.59 Class U messages support (Sending P to F).29Table A.60 Class U messages support (Receipt F to P).29Table A.61 Class A I-command (Numbered Information) (Sending P to F).29Table A.62 Class A I-command (Numbered Information) (Receipt F to P).30Table A.63 Class A I-command Control field (Sending P to F).30Table A.64 Class A I-command Control field (Receipt F to P).30Table A.65 Class A I-command Address field (Sending P to F).30Table A.66. Class A I-command Address field (Receipt F to P).30Table A.67 Class A RR-command/response (Receive ready) (Sending P to F).31Table A.68 Class A RR-command/response (Receive ready) (Receipt F to P).31Table A.69 Class A RR Control field (Sending P to F).31Table A.70 Class A RR Control field (Receipt F to P).31Table A.71 Class A RR Address field (Sending P to F).31Table A.72 Class A RR Address field (Receipt F to P).32Table A.73 Class B I-command (Numbered Information) (Sending P to F).32Table A.74 Class B I-command (Numbered Information) (Receipt F to P).32Table A.75 Class B I-command Control field (Sending P to F).32Table A.76 Class B I-command Control field (Receipt F to P).32Table A.77 Class B I-command Address field (Sending P to F).33Table A.78 Class B I-command Address field (Receipt F to P).33Table A.79 Class B RR-command/response (Receive ready) (Sending P to F).33Table A.80 Class B RR-command/response (Receive ready) (Receipt F to P).33Table A.81 Class B RR Control field (Sending P to F).33Table A.82 Class B RR Control field (Receipt F to P).34Table A.83 Class B RR Address field (Sending P to F).34Table A.84 Class B RR Address field (Receipt F to P).34Table A.85 Class B RNR command/response (Receive Not Ready) (Sending P to F).34Table A.86 Class B RNR command/response (Receive Not Ready) (Receipt F to P).34Table A.87 Class B RNR Control field (Sending P to F).35Table A.88 Class B RNR Control field (Receipt F to P).35Table A.89 Class B RNR Address field (Sending P to F).35Table A.90 Class B RNR Address field (Receipt F to P).35Table A.91 Class B REJ command/response (Reject) (Sending P to F).35Table A.92 Class B REJ command/response (Reject) (Receipt F to P).36SIST ETS 300 476-2:1999



Page 6ETS 300 476-2: August 1996Table A.93 Class B REJ Control field (Sending P to F).36Table A.94 Class B REJ Control field (Receipt F to P).36Table A.95 Class B REJ Address field (Sending P to F).36Table A.96 Class B REJ Address field (Receipt F to P).36Table A.97 Class B SABM command (Sending P to F).37Table A.98 Class B SABM command (Receipt F to P).37Table A.99 Class B SABM Control field (Sending P to F).37Table A.100 Class B SABM Control field (Receipt F to P).37Table A.101 Class B SABM Address field (Sending P to F).37Table A.102 Class B SABM Address field (Receipt F to P).38Table A.103 Class B DM-response (Disconnect Mode) (Sending P to F).38Table A.104 Class B DM-response (Disconnect Mode) (Receipt F to P).38Table A.105 Class B DM Control field (Sending P to F).38Table A.106 Class B DM Control field (Receipt F to P).38Table A.107 Class B DM Address field (Sending P to F).39Table A.108 Class B DM Address field (Receipt F to P).39Table A.109 Class B DISC command (Disconnect) (Sending P to F).39Table A.110 Class B DISC command (Disconnect) (Receipt F to P).39Table A.111 Class B DISC Control field (Sending P to F).39Table A.112 Class B DISC Control field (Receipt F to P).40Table A.113 Class B DISC Address field (Sending P to F).40Table A.114 Class B DISC Address field (Receipt F to P).40Table A.115 Class B UA-response (Unnumbered ACK) (Sending P to F).40Table A.116 Class B UA-response (Unnumbered ACK) (Receipt F to P).40Table A.117 Class B UA Control field (Sending P to F).41Table A.118 Class B UA Control field (Receipt F to P).41Table A.119 Class B UA Address field (Sending P to F).41Table A.120 Class B UA Address field (Receipt F to P).41Table A.121 Class U UI command (Unnumbered Information) (Sending P to F).41Table A.122 Class U UI command (Unnumbered Information) (Receipt F to P).42Table A.123 Class U UI Control field (Sending P to F).42Table A.124 Class U UI Control field (Receipt F to P).42Table A.125 Class U UI Address field (Sending P to F).42Table A.126 Class U UI Address field (Receipt F to P).42Table A.127 U-plane frames (Sending P to F).43Table A.128 U-plane frames (Receipt F to P).43Table A.129 FU1 frame structure (Sending P to F).43Table A.130 FU1 frame structure (Receipt F to P).43Table A.131 FU4 frame structure (Sending P to F).44Table A.132 FU4 frame structure (Receipt F to P).44Table A.133 FU4 Length indicator field (Sending P to F).44Table A.134 FU4 Length indicator field (Receipt F to P).44Table A.135 FU4 Send sequence number (Sending P to F).44Table A.136 FU4 Send sequence number (Receipt F to P).44Table A.137 FU4 Receive sequence number (Sending P to F).45Table A.138 FU4 Receive sequence number (Receipt F to P).45Table A.139 FU5 frame structure (Sending P to F).45Table A.140 FU5 frame structure (Receipt F to P).45Table A.141 FU5 Address field (Sending P to F).45Table A.142 FU5 Address field (Receipt F to P).46Table A.143 FU5 Length indicator field (Sending P to F).46Table A.144 FU5 Length indicator field (Receipt F to P).46Table A.145 FU5 Send sequence number (Sending P to F).46Table A.146 FU5 Send sequence number (Receipt F to P).46Table A.147 FU5 Receive sequence number (Sending P to F).46Table A.148 FU5 Receive sequence number (Receipt F to P).47Table A.149 FU6a frame structure (Sending P to F).47Table A.150 FU6a frame structure (Receipt F to P).47Table A.151 FU6a Length indicator field (Sending P to F).47Table A.152 FU6a Length indicator field (Receipt F to P).47Table A.153 FU6a Send sequence number (Sending P to F).47Table A.154 FU6a Send sequence number (Receipt F to P).48Table A.155 FU6b frame structure (Sending P to F).48SIST ETS 300 476-2:1999



Page 7ETS 300 476-2: August 1996Table A.156 FU6b frame structure (Receipt F to P).48Table A.157 FU6b Receive sequence number (Sending P to F).48Table A.158 FU6b Receive sequence number (Receipt F to P).48Table A.159 FU7 64 kbit/s frame structure (Sending P to F).49Table A.160 FU7 64 kbit/s frame structure (Receipt F to P).49Table A.161 FU7 64 kbit/s control field (Sending P to F).49Table A.162 FU7 64 kbit/s control field (Receipt F to P).50Table A.163 FU7 72 kbit/s frame structure (Sending P to F).50Table A.164 FU7 72 kbit/s frame structure (Receipt F to P).50Table A.165 FU7 72 kbit/s control field (Sending P to F).
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.