Transmission and Multiplexing (TM); Generic requirements of transport functionality of equipment; Part 4-1: Synchronous Digital Hierarchy (SDH) path layer functions

REN/TM-01042-4-1

Prenos in multipleksiranje (TM) – Generične zahteve za prenosno funkcionalnost opreme – 4-1. del: Funkcije plasti poti pri sinhroni digitalni hierarhiji (SDH)

General Information

Status
Published
Publication Date
21-Oct-2001
Current Stage
12 - Completion
Due Date
29-Oct-2001
Completion Date
22-Oct-2001

Buy Standard

Standard
EN 300 417-4-1 V1.2.1:2003
English language
298 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 417-4-1 V1.2.1:2003
01-december-2003
3UHQRVLQPXOWLSOHNVLUDQMH 70 ±*HQHULþQH]DKWHYH]DSUHQRVQRIXQNFLRQDOQRVW
RSUHPH±GHO)XQNFLMHSODVWLSRWLSULVLQKURQLGLJLWDOQLKLHUDUKLML 6'+
Transmission and Multiplexing (TM); Generic requirements of transport functionality of
equipment; Part 4-1: Synchronous Digital Hierarchy (SDH) path layer functions
Ta slovenski standard je istoveten z: EN 300 417-4-1 Version 1.2.1
ICS:
33.040.20 Prenosni sistem Transmission systems
SIST EN 300 417-4-1 V1.2.1:2003 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003

---------------------- Page: 2 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003

ETSI EN 300 417-4-1 V1.2.1 (2001-10)
European Standard (Telecommunications series)


Transmission and Multiplexing (TM);
Generic requirements of transport functionality of equipment;
Part 4-1: Synchronous Digital Hierarchy (SDH)
path layer functions

---------------------- Page: 3 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003
 2 ETSI EN 300 417-4-1 V1.2.1 (2001-10)



Reference
REN/TM-01042-4-1
Keywords
architecture, SDH, transmission, interface
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2001.
All rights reserved.

ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003
 3 ETSI EN 300 417-4-1 V1.2.1 (2001-10)
Contents
Intellectual Property Rights.8
Foreword.8
1 Scope.10
2 References.10
3 Definitions, abbreviations and symbols .11
3.1 Definitions.11
3.2 Abbreviations.11
3.3 Symbols and diagrammatic conventions .14
3.4 Introduction.14
4 VC-4 Path Layer Functions.14
4.1 VC-4 Layer Connection Function S4_C .17
4.1.1 SNC Protection.19
4.2 VC-4 Layer Trail Termination Functions.20
4.2.1 VC-4 Layer Trail Termination Source S4_TT_So.20
4.2.2 VC-4 Layer Trail Termination Sink S4_TT_Sk .22
4.3 VC-4 Layer Adaptation Functions .24
4.3.1 VC-4 Layer to P4x Layer Adaptation Source S4/P4x_A_So .24
4.3.2 VC-4 Layer to P4x Layer Adaptation Sink S4/P4x_A_Sk .27
4.3.3 VC-4 Layer to P4e Layer Adaptation Source S4/P4e_A_So.28
4.3.4 VC-4 Layer to P4e Layer Adaptation Sink S4/P4e_A_Sk.29
4.3.5 VC-4 Layer to VC-3, VC-2, VC-12, and VC-11 Layer Compound Adaptation Source Function
S4/SX_A_So.31
4.3.5.1 VC-4 Layer to TUG Adaptation Source Function S4/TUG_A_So .33
4.3.5.2 TUG Termination Source Function TUG_T_So.35
4.3.5.3 TUG to VC-3 Layer Adaptation Source Function TUG/S3_A_So/K.0.0 .35
4.3.5.4 TUG to VC-2 Layer Adaptation Source Function TUG/S2_A_So/K.L.0.37
4.3.5.5 TUG to VC-12 Layer Adaptation Source Function TUG/S12_A_So/K.L.M .40
4.3.5.6 TUG to VC-11 Layer Adaptation Source Function TUG/S11*_A_So/K.L.M .43
4.3.6 VC-4 Layer to VC-3, VC-2, VC-12, and VC-11 Layer Compound Adaptation Sink Function
S4/SX_A_Sk.46
4.3.6.1 VC-4 Layer to TUG Adaptation Sink Function S4/TUG_A_Sk.48
4.3.6.2 TUG Termination Sink Function TUG_T_Sk.49
4.3.6.3 TUG to VC-3 Layer Adaptation Sink Function TUG/S3_A_Sk/K.0.0.50
4.3.6.4 TUG to VC-2 Layer Adaptation Sink Function TUG/S2_A_Sk.51
4.3.6.5 TUG to VC-12 Layer Adaptation Sink Function TUG/S12_A_Sk/K.L.M.52
4.3.6.6 TUG to VC-11 Layer Adaptation Sink Function TUG/S11*_A_Sk/K.L.M.53
4.3.7 VC-4 Layer to P0s Layer Adaptation Source S4/P0s_A_So .55
4.3.8 VC-4 Layer to P0s Layer Adaptation Sink S4/P0s_A_Sk .56
4.3.9 VC-4 Layer to DQDB Layer Adaptation Source S4/DQDB_A_So .57
4.3.10 VC-4 Layer to DQDB Layer Adaptation Sink S4/DQDB_A_Sk .59
4.3.11 VC-4 Layer to TSS1 Adaptation Source S4/TSS1_A_So .61
4.3.12 VC-4 Layer to TSS1 Adaptation Sink S4/TSS1_A_Sk .63
4.3.13 VC-4 Layer to ATM Virtual Path Layer Compound Adaptation Source function S4/Avp_A_So .64
4.3.14 VC-4 Layer to ATM Virtual Path Layer Compound Adaptation Sink function S4/Avp_A_Sk.64
4.3.15 VC-4 Layer Clock Adaptation Source S4-LC_A_So.64
4.4 VC-4 Layer Monitoring Functions.64
4.4.1 Type 1 VC-4 Layer Non-intrusive Monitoring Function S4m_TT_Sk .64
4.4.2 VC-4 Layer Supervisory-Unequipped Termination Source S4s_TT_So.66
4.4.3 VC-4 Layer Supervisory-unequipped Termination Sink S4s_TT_Sk .68
4.4.4 Type 2 VC-4 Layer Non-intrusive Monitoring Function S4m2_TT_Sk .70
4.5 VC-4 Layer Trail Protection Functions .72
4.5.1 VC-4 Trail Protection Connection Functions S4P_C .72
4.5.1.1 VC-4 Layer 1+1 uni-directional Protection Connection Function S4P1+1u_C.72
4.5.1.2 VC-4 Layer Protection bi-directional Connection Function S4P1+1b_C .74
ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003
 4 ETSI EN 300 417-4-1 V1.2.1 (2001-10)
4.5.2 VC-4 Layer Trail Protection Trail Termination Functions .75
4.5.2.1 VC-4 Protection Trail Termination Source S4P_TT_So.75
4.5.2.2 VC-4 Protection Trail Termination Sink S4P_TT_Sk .76
4.5.3 VC-4 Layer Linear Trail Protection Adaptation Functions .77
4.5.3.1 VC-4 trail to VC-4 trail Protection Layer Adaptation Source S4/S4P_A_So .77
4.5.3.2 VC-4 trail to VC-4 trail Protection Layer Adaptation Sink S4/S4P_A_Sk.78
4.6 VC-4 Tandem Connection Sublayer Functions.79
4.6.1 VC-4 Tandem Connection Trail Termination Source function (S4D_TT_So).79
4.6.2 VC-4 Tandem Connection Trail Termination Sink function (S4D_TT_Sk).82
4.6.3 VC-4 Tandem Connection to VC-4 Adaptation Source function (S4D/S4_A_So) .86
4.6.4 VC-4 Tandem Connection to VC-4 Adaptation Sink function (S4D/S4_A_Sk) .87
4.6.5 VC-4 Tandem Connection Non-intrusive Monitoring Trail Termination Sink function
(S4Dm_TT_Sk) .88
5 VC-3 Path Layer Functions.91
5.1 VC-3 Layer Connection Function S3_C .94
5.1.1 SNC Protection.96
5.2 VC-3 Layer Trail Termination Functions.97
5.2.1 VC-3 Layer Trail Termination Source S3_TT_So.97
5.2.2 VC-3 Layer Trail Termination Sink S3_TT_Sk .99
5.3 VC-3 Layer Adaptation Functions .101
5.3.1 VC-3 Layer to P31x Layer Adaptation Source S3/P31x_A_So .101
5.3.2 VC-3 Layer to P31x Layer Adaptation Sink S3/P31x_A_Sk .104
5.3.3 VC-3 Layer to P31e Layer Adaptation Source S3/P31e_A_So.105
5.3.4 VC-3 Layer to P31e Layer Adaptation Sink S3/P31e_A_Sk.107
5.3.5 VC-3 Layer to P0s Layer Adaptation Source S3/P0s_A_So .109
5.3.6 VC-3 Layer to P0s Layer Adaptation Sink S3/P0s_A_Sk .110
5.3.7 VC-3 Layer to TSS3 Adaptation Source S3/TSS3_A_So .111
5.3.8 VC-3 Layer to TSS3 Adaptation Sink S3/TSS3_A_Sk .112
5.3.9 VC-3 Layer to ATM Virtual Path Layer Compound Adaptation Source function S3/Avp_A_So .113
5.3.10 VC-3 Layer to ATM Virtual Path Layer Compound Adaptation Sink function S3/Avp_A_Sk.113
5.3.11 VC-3 Layer Clock Adaptation Source S3-LC_A_So.113
5.4 VC-3 Layer Monitoring Functions.114
5.4.1 Type 1 VC-3 Layer Non-intrusive Monitoring Function S3m_TT_Sk .114
5.4.2 VC-3 Layer Supervisory-Unequipped Termination Source S3s_TT_So.116
5.4.3 VC-3 Layer Supervisory-unequipped Termination Sink S3s_TT_Sk .117
5.4.4 Type 2 VC-3 Layer Non-intrusive Monitoring Function S3m2_TT_Sk .119
5.5 VC-3 Layer Trail Protection Functions .122
5.5.1 VC-3 Trail Protection Connection Functions S3P_C .122
5.5.1.1 VC-3 Layer 1+1 uni-directional Protection Connection Function S3P1+1u_C.122
5.5.1.2 VC-3 Layer bi-directional Protection Connection Function S3P1+1b_C .123
5.5.2 VC-3 Layer Trail Protection Trail Termination Functions .125
5.5.2.1 VC-3 Protection Trail Termination Source S3P_TT_So.125
5.5.2.2 VC-3 Protection Trail Termination Sink S3P_TT_Sk .126
5.5.3 VC-3 Layer Linear Trail Protection Adaptation Functions .127
5.5.3.1 VC-3 trail to VC-3 trail Protection Layer Adaptation Source S3/S3P_A_So .127
5.5.3.2 VC-3 trail to VC-3 trail Protection Layer Adaptation Sink S3/S3P_A_Sk.127
5.6 VC-3 Tandem Connection Sublayer Functions.128
5.6.1 VC-3 Tandem Connection Trail Termination Source function (S3D_TT_So).128
5.6.2 VC-3 Tandem Connection Trail Termination Sink function (S3D_TT_Sk).131
5.6.3 VC-3 Tandem Connection to VC-3 Adaptation Source function (S3D/S3_A_So) .136
5.6.4 VC-3 Tandem Connection to VC-3 Adaptation Sink function (S3D/S3_A_Sk) .137
5.6.5 VC-3 Tandem Connection Non-intrusive Monitoring Trail Termination Sink function
(S3Dm_TT_Sk) .138
6 VC-2 Path Layer Functions.141
6.1 VC-2 Layer Connection Function S2_C .145
6.1.1 SNC Protection.146
6.2 VC-2 Layer Trail Termination Functions.148
6.2.1 VC-2 Layer Trail Termination Source S2_TT_So.148
6.2.2 VC-2 Layer Trail Termination Sink S2_TT_Sk .149
6.3 VC-2 Layer Adaptation Functions .151
ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003
 5 ETSI EN 300 417-4-1 V1.2.1 (2001-10)
6.3.1 VC-2 Layer to TSS4 Adaptation Source S2/TSS4_A_So .151
6.3.2 VC-2 Layer to TSS4 Adaptation Sink S2/TSS4_A_Sk .152
6.3.3 VC-2 Layer to ATM Virtual Path Layer Compound Adaptation Source function S2/Avp_A_So .153
6.3.4 VC-2 Layer to ATM Virtual Path Layer Compound Adaptation Sink function S2/Avp_A_Sk.153
6.3.5 VC-2 Layer Clock Adaptation Source S2-LC_A_So.153
6.4 VC-2 Layer Monitoring Functions.153
6.4.1 Type 1 VC-2 Layer Non-intrusive Monitoring Function S2m_TT_Sk .153
6.4.2 VC-2 Layer Supervisory-Unequipped Termination Source S2s_TT_So.155
6.4.3 VC-2 Layer Supervisory-unequipped Termination Sink S2s_TT_Sk .156
6.4.4 Type 2 VC-2 Layer Non-intrusive Monitoring Function S2m2_TT_Sk .158
6.5 VC-2 Layer Trail Protection Functions .160
6.5.1 VC-2 Trail Protection Connection Functions S2P_C .160
6.5.1.1 VC-2 Layer 1+1 uni-directional Protection Connection Function S2P1+1u_C.160
6.5.1.2 VC-2 Layer 1+1 dual ended Protection Connection Function S2P1+1b_C.162
6.5.2 VC-2 Layer Trail Protection Trail Termination Functions .163
6.5.2.1 VC-2 Protection Trail Termination Source S2P_TT_So.163
6.5.2.2 VC-2 Protection Trail Termination Sink S2P_TT_Sk .164
6.5.3 VC-2 Layer Linear Trail Protection Adaptation Functions .165
6.5.3.1 VC-2 trail to VC-2 trail Protection Layer Adaptation Source S2/S2P_A_So .165
6.5.3.2 VC-2 trail to VC-2 trail Protection Layer Adaptation Sink S2/S2P_A_Sk.166
6.6 VC-2 Tandem Connection Sublayer Functions.167
6.6.1 VC-2 Tandem Connection Trail Termination Source function (S2D_TT_So).167
6.6.2 VC-2 Tandem Connection Trail Termination Sink function (S2D_TT_Sk).170
6.6.3 VC-2 Tandem Connection to VC-2 Adaptation Source function (S2D/S2_A_So) .174
6.6.4 VC-2 Tandem Connection to VC-2 Adaptation Sink function (S2D/S2_A_Sk) .175
6.6.5 VC-2 Tandem Connection Non-intrusive Monitoring Trail Termination Sink function
(S2Dm_TT_Sk) .176
7 VC-12 Path Layer Functions.179
7.1 VC-12 Layer Connection Function S12_C .183
7.1.1 SNC Protection.185
7.2 VC-12 Trail Termination Functions.186
7.2.1 VC-12 Trail Termination Source S12_TT_So.186
7.2.2 VC-12 Trail Termination Sink S12_TT_Sk.188
7.3 VC-12 Adaptation Functions.190
7.3.1 VC-12 to P12x Adaptation Source S12/P12x_A_So .190
7.3.2 VC-12 to P12x Adaptation Sink S12/P12x_A_Sk.192
7.3.3 VC-12 to P12s Adaptation Source S12/P12s_A_So.194
7.3.3.1 Type 1 VC-12 to P12s Adaptation Source S12/P12s-b_A_So.194
7.3.3.2 Type 2 VC-12 to P12s Adaptation Source S12/P12s-a_A_So .197
7.3.4 VC-12 to P12s Adaptation Sink S12/P12s_A_Sk.198
7.3.4.1 Type 1 VC-12 to P12s Adaptation Sink S12/P12s-x_A_Sk.198
7.3.4.2 Type 2 VC-12 to P12s Adaptation Sink S12/P12s-b_A_Sk.200
7.3.4.3 Type 3 VC-12 to P12s Adaptation Sink S12/P12s-a_A_Sk.202
7.3.5 VC-12 to P0-31c Adaptation Source S12/P0-31c_A_So.205
7.3.6 VC-12 to P0-31c Adaptation Sink S12/P0-31c_A_Sk.207
7.3.7 VC-12 Layer to TSS4 Adaptation Source S12/TSS4_A_So .208
7.3.8 VC-12 Layer to TSS4 Adaptation Sink S12/TSS4_A_Sk .209
7.3.9 VC-12 Layer to ATM Virtual Path Layer Compound Adaptation Source function S12/Avp_A_So .210
7.3.10 VC-12 Layer to ATM Virtual Path Layer Compound Adaptation Sink function S12/Avp_A_Sk.210
7.3.11 VC-12 Layer Clock Adaptation Source S12-LC_A_So.210
7.4 VC-12 Layer Monitoring Functions.210
7.4.1 Type 1 VC-12 Layer Non-intrusive Monitoring Function S12m_TT_Sk.210
7.4.2 VC-12 Layer Supervisory-Unequipped Termination Source S12s_TT_So.212
7.4.3 VC-12 Layer Supervisory-unequipped Termination Sink S12s_TT_Sk .214
7.4.4 Type 2 VC-12 Layer Non-intrusive Monitoring Function S12m2_TT_Sk.216
7.5 VC-12 Layer Trail Protection Functions .218
7.5.1 VC-12 Trail Protection Connection Functions S12P_C .218
7.5.1.1 VC-12 Layer 1+1 uni-directional Protection Connection Function S12P1+1u_C.218
7.5.1.2 VC-12 Layer 1+1 dual ended Protection Connection Function S12P1+1b_C .220
7.5.2 VC-12 Layer Trail Protection Trail Termination Functions .221
7.5.2.1 VC-12 Protection Trail Termination Source S12P_TT_So.221
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 417-4-1 V1.2.1:2003
 6 ETSI EN 300 417-4-1 V1.2.1 (2001-10)
7.5.2.2 VC-12 Protection Trail Termination Sink S12P_TT_Sk .222
7.5.3 VC-12 Layer Linear Trail Protection Adaptation Functions .223
7.5.3.1 VC-12 trail to VC-12 trail Protection Layer Adaptation Source S12/S12P_A_So .223
7.5.3.2 VC-12 trail to VC-12 trail Protection Layer Adaptation Sink S12/S12P_A_Sk.224
7.6 VC-12 Tandem Connection Sublayer Functions.225
7.6.1 VC-12 Tandem Connection Trail Termination Source function (S12D_TT_So).225
7.6.2 VC-12 Tandem Connection Trail Termination Sink function (S12D_TT_Sk).228
7.6.3 VC-12 Tandem Connection to VC-12 Adaptation Source function (S12D/S12_A_So) .232
7.6.4 VC-12 Tandem Connection to VC-12 Adaptation Sink function (S12D/S12_A_Sk) .233
7.6.5 VC-12 Tandem Connection Non-intrusive Monitoring Trail Termination Sink function
(S12Dm_TT_Sk) .234
Annex A (informative): Jitter/wander in justification processes .237
A.1 VC-n phase accuracy/timing error/jitter/wander.237
A.2 VC-n pointer processor introduced phase error measurement .237
A.3 SDH/PDH and PDH/PDH mapping introduced phase error measurement.240
Annex B (informative): SDH/PDH interconnection examples .241
Annex C (informative): Interaction between 2 Mbit/s and VC-12 signals for the case of byte
synchronous mapping.243
Annex D (informative): Examples of linear trail and SNC protection models .245
Annex E (informative): VC-3 to 44 736 Mbit/s adaptation functions.248
E.1 VC-3 Layer to P32x Layer Adaptation Source S3/P32x_A_So.248
E.2 VC-3 Layer to P32x Layer Adaptation Sink S3/P32x_A_Sk .250
Annex F (informative): VC-11 Path Layer Functions .253
F.1 VC-11 Layer Connection Function S11_C .257
F.1.1 SNC Protection.258
F.2 VC-11 Trail Termination Functions.260
F.2.1 VC-11 Trail Termination Source S11_TT_So .260
F.2.2 VC-11 Trail Termination Sink S11_TT_Sk .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.