ETSI TS 102 221 V16.6.0 (2021-10)
Smart Cards; UICC-Terminal interface; Physical and logical characteristics (Release 16)
Smart Cards; UICC-Terminal interface; Physical and logical characteristics (Release 16)
RTS/SCP-T102221vg60
General Information
Standards Content (Sample)
ETSI TS 102 221 V16.6.0 (2021-10)
TECHNICAL SPECIFICATION
Smart Cards;
UICC-Terminal interface;
Physical and logical characteristics
(Release 16)
---------------------- Page: 1 ----------------------
Release 16 2 ETSI TS 102 221 V16.6.0 (2021-10)
Reference
RTS/SCP-T102221vg60
Keywords
smart card
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
No representation or warranty is made that this deliverable is technically accurate or sufficient or conforms to any law
and/or governmental rule and/or regulation and further, no representation or warranty is made of merchantability or fitness
for any particular purpose or against infringement of intellectual property rights.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2021.
All rights reserved.
ETSI
---------------------- Page: 2 ----------------------
Release 16 3 ETSI TS 102 221 V16.6.0 (2021-10)
Contents
Intellectual Property Rights . 12
Foreword . 12
Modal verbs terminology . 13
Introduction . 13
1 Scope . 14
2 References . 14
2.1 Normative references . 14
2.2 Informative references . 16
3 Definition of terms, symbols, abbreviations and coding conventions . 16
3.1 Terms . 16
3.2 Symbols . 18
3.3 Abbreviations . 19
3.4 Coding conventions . 21
4 Physical characteristics. 21
4.0 UICC Form Factors . 21
4.0.0 Generic requirements . 21
4.0.1 ID-1 UICC . 21
4.0.2 Plug-in UICC . 21
4.0.3 Mini-UICC . 22
4.0.4 4FF . 23
4.1 ID-1 UICC . 24
4.2 Plug-in UICC . 24
4.3 Mini-UICC . 24
4.4 Environmental conditions for card operation and storage . 24
4.4.0 Standard UICC environmental conditions . 24
4.4.1 Specific UICC environmental conditions . 25
4.4.1.0 Specific UICC environmental conditions indication . 25
4.4.1.1 Temperature range for specific UICC environmental conditions. 25
4.4.1.2 High humidity . 25
4.5 Contacts . 25
4.5.1 Provision of contacts . 25
4.5.1.1 Terminal . 25
4.5.1.2 UICC . 25
4.5.2 Contact activation and deactivation . 26
4.5.2.1 Contacts assigned by the present document . 26
4.5.2.2 Optional contacts . 26
4.5.3 Inactive contacts . 26
4.5.4 Contact pressure . 26
5 Electrical specifications of the UICC - Terminal interface . 27
5.0 General requirements . 27
5.1 Class A operating conditions . 27
5.1.1 Supply voltage Vcc (contact C1) . 27
5.1.2 Reset (RST) (contact C2) . 28
5.1.3 Programming voltage Vpp (contact C6) . 28
5.1.4 Clock CLK (contact C3) . 28
5.1.5 I/O (contact C7) . 29
5.2 Class B operating conditions . 29
5.2.1 Supply voltage Vcc (contact C1) . 29
5.2.2 Reset (RST) (contact C2) . 30
5.2.3 Clock CLK (contact C3) . 30
5.2.4 I/O (contact C7) . 30
5.3 Class C operating conditions . 31
5.3.1 Supply voltage Vcc (contact C1) . 31
ETSI
---------------------- Page: 3 ----------------------
Release 16 4 ETSI TS 102 221 V16.6.0 (2021-10)
5.3.2 Reset (RST) (contact C2) . 31
5.3.3 Clock CLK (contact C3) . 31
5.3.4 I/O (contact C7) . 32
6 Initial communication establishment procedures . 32
6.1 UICC activation and deactivation. 32
6.2 Supply voltage switching . 32
6.2.0 UICC activation voltage . 32
6.2.1 Supply voltage classes . 33
6.2.2 Power consumption of the UICC during ATR . 33
6.2.3 Application related electrical parameters . 33
6.3 Answer To Reset content . 34
6.3.0 Introduction. 34
6.3.1 Coding of historical bytes . 34
6.3.2 Speed enhancement. 34
6.3.3 Global Interface bytes . 35
6.4 PPS procedure . 35
6.5 Reset procedures . 36
6.5.1 Cold reset . 36
6.5.2 Warm reset . 36
6.5.3 Reaction to resets . 36
6.6 Clock stop mode . 36
6.7 Bit/character duration and sampling time . 36
6.8 Error handling . 37
6.9 Compatibility . 37
7 Transmission protocols. 37
7.0 Introduction . 37
7.1 Physical layer . 38
7.2 Data link layer . 38
7.2.0 Introduction. 38
7.2.1 Character frame . 39
7.2.1.0 Structure, coding and timing . 39
7.2.1.1 Low impedance I/O line behaviour . 39
7.2.2 Transmission protocol T = 0 . 40
7.2.2.0 Introduction . 40
7.2.2.1 Timing and specific options for characters in T = 0 . 40
7.2.2.2 Command header . 40
7.2.2.3 Command processing . 40
7.2.2.3.0 General description . 40
7.2.2.3.1 Procedure bytes . 40
7.2.2.3.2 Status bytes . 41
7.2.2.4 Error detection and correction . 41
7.2.3 Transmission protocol T = 1 . 41
7.2.3.0 Introduction . 41
7.2.3.1 Timing and specific options for blocks sent with T = 1 . 42
7.2.3.1.0 Introduction . 42
7.2.3.1.1 Information field size . 42
7.2.3.1.2 Character waiting integer. 42
7.2.3.1.3 Character waiting time . 42
7.2.3.1.4 Block waiting time . 42
7.2.3.1.5 Block guard time . 42
7.2.3.1.6 Waiting time extension . 43
7.2.3.1.7 Error detection code . 43
7.2.3.2 Block frame structure . 43
7.2.3.2.0 Overall structure . 43
7.2.3.2.1 Prologue field . 43
7.2.3.2.2 Epilogue field . 45
7.2.3.2.3 Block notations . 45
7.2.3.3 Error free operation . 46
7.2.3.4 Error handling for T = 1 . 46
7.2.3.4.0 General description . 46
ETSI
---------------------- Page: 4 ----------------------
Release 16 5 ETSI TS 102 221 V16.6.0 (2021-10)
7.2.3.4.1 Protocol initialization . 47
7.2.3.4.2 Block dependent errors . 47
7.2.3.5 Chaining . 47
7.2.3.5.0 Chaining Mechanism . 47
7.2.3.5.1 Rules for chaining. 48
7.3 Transport layer . 48
7.3.0 Introduction. 48
7.3.1 Transportation of an APDU using T = 0 . 48
7.3.1.0 Introduction . 48
7.3.1.1 Mapping of APDUs to TPDUs . 48
7.3.1.1.0 General behaviour . 48
7.3.1.1.1 Case 1 . 49
7.3.1.1.2 Case 2 . 49
7.3.1.1.3 Case 3 . 50
7.3.1.1.4 Case 4 . 51
7.3.1.1.5 Use of procedure bytes '61xx' and '6Cxx' . 52
7.3.2 Transportation of a APDU using T = 1 . 53
7.3.2.0 General mechanism . 53
7.3.2.1 Case 1 . 53
7.3.2.2 Case 2 . 53
7.3.2.3 Case 3 . 54
7.3.2.4 Case 4 . 54
7.4 Application layer . 54
7.4.0 Overall description . 54
7.4.1 Exchange of APDUs . 55
7.4.2 CAT layer . 55
7.4.2.0 Overview . 55
7.4.2.1 Proactive command . 55
7.4.2.2 ENVELOPE Commands . 56
7.4.3 Application execution . 56
8 Application and file structure . 57
8.1 UICC application structure . 57
8.2 File types . 57
8.2.0 Introduction. 57
8.2.1 Dedicated files . 58
8.2.2 Elementary files . 58
8.2.2.1 Transparent EF . 58
8.2.2.2 Linear fixed EF . 58
8.2.2.3 Cyclic EF . 58
8.2.2.4 BER-TLV structure EF . 59
8.3 File referencing . 59
8.4 Methods for selecting a file . 59
8.4.0 Default state after UICC activation and ATR . 59
8.4.1 SELECT by File Identifier referencing . 60
8.4.2 SELECT by path referencing . 61
8.4.3 Short File Identifier (SFI) . 62
8.5 Application characteristics . 62
8.5.0 Application selection types . 62
8.5.1 Explicit application selection . 62
8.5.1.1 SELECT by DF name . 62
8.5.1.2 SELECT by partial DF name .
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.