Telecommunications Management Network (TMN); Q3 interface at the Access Network (AN) for fault and performance management of V5 interfaces and associated user ports; Part 1: Q3 interface specification

REN/TMN-02003-1

Telekomunikacijsko upravljavno omrežje (TMN) - Vmesnik Q3 dostopovnega omrežja (AN) za upravljanje okvar in delovanja vmesnikov V5 in pridruženih uporabniških priključkov - 1. del: Specifikacija vmesnika Q3

General Information

Status
Published
Publication Date
28-Oct-1999
Current Stage
12 - Completion
Due Date
15-Oct-1999
Completion Date
29-Oct-1999

Buy Standard

Standard
EN 300 378-1 V1.2.1:2003
English language
73 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.YQHJDLGUXåHQLKTelecommunications Management Network (TMN); Q3 interface at the Access Network (AN) for fault and performance management of V5 interfaces and associated user ports; Part 1: Q3 interface specification33.040.35Telefonska omrežjaTelephone networksICS:Ta slovenski standard je istoveten z:EN 300 378-1 Version 1.2.1SIST EN 300 378-1 V1.2.1:2003en01-november-2003SIST EN 300 378-1 V1.2.1:2003SLOVENSKI
STANDARD



SIST EN 300 378-1 V1.2.1:2003



ETSI EN 300 378-1 V1.2.1 (1999-10)European Standard (Telecommunications series)Telecommunications Management Network (TMN);Q3 interface at the Access Network (AN)for fault and performance managementof V5 interfaces and associated user ports;Part 1: Q3 interface specificationSIST EN 300 378-1 V1.2.1:2003



ETSIETSI EN 300 378-1 V1.2.1 (1999-10)2ReferenceREN/TMN-02003-1 (3i090ioo.PDF)KeywordsAN, information model, management,performance, Q3 interface, TMN, V5 interfaceETSIPostal addressF-06921 Sophia Antipolis Cedex - FRANCEOffice address650 Route des Lucioles - Sophia AntipolisValbonne - FRANCETel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16Siret N° 348 623 562 00017 - NAF 742 CAssociation à but non lucratif enregistrée à laSous-Préfecture de Grasse (06) N° 7803/88Internetsecretariat@etsi.frIndividual copies of this ETSI deliverablecan be downloaded fromhttp://www.etsi.orgIf you find errors in the present document, send yourcomment to: editor@etsi.frImportant noticeThis ETSI deliverable may be made available in more than one electronic version or in print. In any case of existing orperceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).In case of dispute, the reference should be the printing on ETSI printers of the PDF version kept on a specific networkdrive within ETSI Secretariat.Copyright NotificationNo part may be reproduced except as authorized by written permission.The copyright and the foregoing restriction extend to reproduction in all media.© European Telecommunications Standards Institute 1999.All rights reserved.SIST EN 300 378-1 V1.2.1:2003



ETSIETSI EN 300 378-1 V1.2.1 (1999-10)3ContentsIntellectual Property Rights.8Foreword.8Introduction.81Scope.102References.103Definitions and abbreviations.123.1Definitions.123.2Abbreviations.134Information model diagrams.144.1Entity relationship diagram.144.1.1Traffic measurement.154.1.2Line testing and line circuit testing.154.1.3The test result notifications of the tests.164.1.4Performance monitoring of ISDN user ports.164.2Inheritance hierarchy.174.3Naming hierarchy.185Information model description.195.1Managed object classes description.195.1.1V5 interface fragment.195.1.2User port fragment.195.1.2.1PSTN user port (pstnUserPort).205.1.2.2ISDN basic access user port (isdnBAUserPort).205.1.2.3ISDN primary rate access user port (isdnPRAUserPort).215.1.2.4Leased port (leasedPort).215.1.3Communication path fragment.215.1.4Protection fragment.215.1.5Performance fragment.225.1.5.1Bearer channel current data.225.1.5.2Bearer channel history data.225.1.5.3Communication channel current data.225.1.5.4Communication channel history data.225.1.6Alarm surveillance fragment.225.1.7Support fragment.225.1.8Test fragment.235.1.8.1Access test (accessTest).235.1.8.2Cable pair identification Tone (cablePairIdTone).235.1.8.3Dialled digit test (dialledDigitTest).235.1.8.4Dial tone test (dialToneTest).245.1.8.5Dry Loop (dryLoop).245.1.8.6Electrical measurement test (electricalMeasurementTest).245.1.8.7ISDN quick test (isdnQuickTest).255.1.8.8Loop test (loopTest).255.1.8.9Metallic test access (metallicTestAccess).265.1.8.10Pattern test (patternTest).265.1.8.11Ringing (ringing).275.1.8.12Subscriber Private Meter (SPM) pulses (spmPulses).275.1.8.13Test to line circuit (testToLineCircuit).275.1.8.14Test threshold class (testThresholdClass).285.1.8.15Voice Access Test (voiceAccessTest).285.2Attributes description.285.3Actions description.285.4Notifications description.29SIST EN 300 378-1 V1.2.1:2003



ETSIETSI EN 300 378-1 V1.2.1 (1999-10)46Formal managed object classes definitions.296.1V5 interface fragment.296.2Access port fragment.296.3Communication path fragment.306.4Protection fragment.306.5Performance fragment.306.6Alarm surveillance fragment.306.7Support fragment.316.8Test fragment.317Protocol requirements.31Annex A (normative):Specification of parameters for V5 specific alarm reports.32A.1Alarm reports related to the V5 interface object class.32A.1.1Control protocol errors.32A.1.2Link control protocol errors.33A.1.3BCC protocol errors.33A.1.4Protection protocol errors.33A.1.5PSTN protocol errors.34A.1.6Interface control failures.34A.1.7V5 data link failures.34A.2Alarm reports related to the V5 trail termination point object class.35A.2.1Link control failures.35A.2.2Link layer 1 failures.36A.3Alarm reports related to the V5 time slot object class.37A.3.1V5 communication channel failures.37A.4Alarm reports related to the user port object class and subclasses.37A.4.1Control protocol errors.37A.4.2PSTN protocol errors.38A.4.3ISDN layer 1 faults (Q(AN) only).38A.4.3.1ISDN BA layer 1 faults (Q(AN) only).38A.4.3.2ISDN PRA layer 1 faults (Q(AN) only).39A.4.4ISDN layer 2 faults (Q(AN) only).40A.4.5Line faults (Q(AN) only).40Annex B (normative):V5 specific traffic measurement.41Annex C (normative):Requirements and specification of parameters for user port tests.42C.1General test requirements.42C.1.1Scheduled testing.42C.1.2Test capability.42C.2V5 interface test requirements.42C.2.1V5 interface ID testing.42C.2.2Link ID testing.42C.2.3Provisioning variant testing.42C.3User port test requirements.43C.3.1User port test management functions.43C.3.2Test scheduling.43C.3.3Test result management.44C.3.4Test threshold management.44C.3.5Test requirements description.44C.3.5.1PSTN line testing.45C.3.5.1.1Foreign voltage or current.45C.3.5.1.2Capacitance measurement.45C.3.5.1.3Insulation resistance measurement.45C.3.5.1.4Loop resistance measurement.45C.3.5.1.5Dial pulse test.45SIST EN 300 378-1 V1.2.1:2003



ETSIETSI EN 300 378-1 V1.2.1 (1999-10)5C.3.5.1.6DTMF dialling test.46C.3.5.1.7Subscriber private meter testing.46C.3.5.1.8Ring subscriber.46C.3.5.1.9Monitoring of the line.46C.3.5.1.10Cable pair identification tone.46C.3.5.1.11Dry loop.46C.3.5.1.12Register recall button test.46C.3.5.1.13Ring back procedure.47C.3.5.2PSTN inward tests.47C.3.5.2.1Line circuit testing.47C.3.5.2.1.1Feeding voltage.47C.3.5.2.1.2Feeding current.47C.3.5.2.1.3Loop and ring trip detection.47C.3.5.2.1.4Ringing current sending.47C.3.5.2.1.5Private meter pulses.47C.3.5.2.1.6Codec testing.47C.3.5.2.1.7Digit reception.48C.3.5.2.2Other inward tests.48C.3.5.2.2.1Dial tone test.48C.3.5.3ISDN BA testing.48C.3.5.3.1ISDN BA line testing.48C.3.5.3.2ISDN BA line termination testing.48C.3.5.3.2.1Loop backs.48C.3.5.3.2.2Activation and deactivation of lines.48C.3.5.3.3ISDN BA line circuit testing.49C.3.5.3.3.1Power feed.49C.3.5.4ISDN PRA testing.49C.3.5.4.1ISDN PRA line testing.49C.3.5.4.2ISDN PRA line termination testing.49Annex D (normative):Test categories.50D.1Dialled digit test.50D.1.1Test category name.50D.1.2Test category purpose.50D.1.3MORT requirements.50D.1.4Associated object requirements.50D.1.5Test environment.50D.1.6Test request service type.50D.1.7Specific errors.50D.1.8Test category information parameter.51D.1.9Uncontrolled test response additional information parameter.51D.2Dial tone test.51D.2.1Test category name.51D.2.2Test category purpose.51D.2.3MORT requirements.51D.2.4Associated object requirements:.51D.2.5Test environment.51D.2.6Test request service type.51D.2.7Specific errors.51D.2.8Test category information parameter.52D.2.9Uncontrolled test response additional information parameter.52D.3Electrical measurement tests.52D.3.1Test category name.52D.3.2Test category purpose.52D.3.3MORT requirements.52D.3.4Associated object requirements.52D.3.5Test environment.52D.3.6Test request service type.52D.3.7Specific errors.53SIST EN 300 378-1 V1.2.1:2003



ETSIETSI EN 300 378-1 V1.2.1 (1999-10)6D.3.8Test category information parameter.53D.3.9Uncontrolled test response additional information parameter.53D.4ISDN quick test.53D.4.1Test category name.53D.4.2Test category purpose:.53D.4.3MORT requirements.53D.4.4Associated object requirements.53D.4.5Test environment.53D.4.6Test request service type:.54D.4.7Specific errors.54D.4.8Test category information parameter.54D.4.9Uncontrolled test response additional information parameter.54D.5Loop back test.54D.5.1Test category name.54D.5.2Test category purpose:.54D.5.3MORT requirements.
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.