ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 6: Ship environments
Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2: Specification of environmental tests; Sub-part 6: Ship environments
REN/EE-017011
Okoljski inženiring (EE) - Okoljski pogoji in preskusi okoljskih vplivov na telekomunikacijsko opremo - 2. del: Specifikacija preskusov vplivov okolja - 6. poddel: Ladijsko okolje
General Information
Buy Standard
Standards Content (Sample)
Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2: Specification of environmental tests;
Sub-part 6: Ship environments
---------------------- Page: 1 ----------------------
2 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Reference
REN/EE-017011
Keywords
environment, maritime, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
https://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2023.
All rights reserved.
ETSI
---------------------- Page: 2 ----------------------
3 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental test specification . 7
4.0 General . 7
4.1 Equipment setup and configuration . 7
4.2 Performance criteria . 8
4.3 Specification T 6.1: Totally weatherprotected locations . 8
4.4 Specification T 6.2: Partly weatherprotected locations . 8
4.5 Specification T 6.3: Non-weatherprotected locations. 8
4.6 Specification T 6.1: Totally weatherprotected locations climatic test . 9
4.7 Specification T 6.2: Partly weatherprotected locations climatic test . 10
4.8 Specification T 6.3: Non-weatherprotected locations climatic tests . 13
4.9 Specification T 6.1, T 6.2 and T 6.3: protected and partly protected installation, mechanical tests . 15
Annex A (informative): Bibliography . 18
History . 19
ETSI
---------------------- Page: 3 ----------------------
4 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The declarations
pertaining to these essential IPRs, if any, are publicly available for ETSI members and non-members, and can be
found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to
ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI Web server (https://ipr.etsi.org/).
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™ and LTE™ are trademarks of ETSI registered for the benefit of its Members and of the 3GPP
Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of the
®
oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 2, sub-part 6 of a multi-part deliverable covering the Environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests";
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
ETSI
---------------------- Page: 4 ----------------------
5 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Part 2-0 [i.1] forms a general overview of part 2. The present document deals with ship environments.
Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
---------------------- Page: 5 ----------------------
6 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to the use of telecommunication equipment installed permanently or
temporarily in ships and cover the environments and the vessels stated in ETSI EN 300 019-1-6 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-6: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-6: Classification of environmental
conditions; Ship environments".
[2] IEC 60068-2-1 (03-2007): "Environmental testing - Part 2-1: Tests - Test A: Cold".
[3] IEC 60068-2-2 (07-2007): "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[4] IEC 60068-2-78 (10-2012): "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat,
steady state".
[5] IEC 60068-2-14 (01-2009): "Environmental testing - Part 2-14: Tests - Test N: Change of
temperature".
[6] IEC 60068-2-30 (08-2005): "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[7] IEC 60068-2-18 (03-2017): "Environmental testing - Part 2-18: Tests - Test R and guidance:
Water".
[8] IEC 60068-2-6 (12-2007): "Environmental testing - Part 2-6: Tests - Test Fc: Vibration
(sinusoidal)".
[9] IEC 60068-2-27 (02-2008): "Environmental testing - Part 2-27: Tests - Test Ea and guidance:
Shock".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
ETSI
---------------------- Page: 6 ----------------------
7 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2: Specification of environmental
tests; Sub-part 0: Introduction".
[i.2] IEC 60068-2 (all parts): "Environmental testing - Part 2: Tests".
[i.3] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
[i.4] IEC 60068-2-52:2017: "Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic
(sodium chloride solution)".
[i.5] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the terms given in ETSI EN 300 019-1-0 [i.3] apply.
3.2 Symbols
For the purposes of the present document, the symbols given in ETSI EN 300 019-1-0 [i.3] apply.
3.3 Abbreviations
For the purposes of the present document, the abbreviations given in ETSI EN 300 019-1-0 [i.3] apply.
4 Environmental test specification
4.0 General
The equipment shall be tested in its operational state throughout the test conditions described in the present document.
The detailed descriptions of the environmental conditions shall refer to clauses 4 and 5 of ETSI EN 300 019-1-6 [1].
ETSI EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multi-part deliverable.
4.1 Equipment setup and configuration
The equipment shall be tested in its operational state throughout the test conditions described in the present document
unless otherwise stated. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
ETSI
---------------------- Page: 7 ----------------------
8 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
4.2 Performance criteria
The following performance criteria shall apply in the tests defined by the present document.
Performance criterion A:
The equipment shall function according to the manufacturer specifications before, during and after the tests. No
degradation of performance or loss of function is allowed below the performance level specified by the manufacturer
when the equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then
this may be deduced from the product description and documentation and what the user may reasonably expect from the
equipment if used as intended.
Performance criterion B:
The equipment shall function according to the manufacturer specifications before and after the tests. During the test it is
not required to monitor the equipment functionality. No degradation of performance or loss of function is allowed
below the performance level specified by the manufacturer when the equipment is used as intended. If the minimum
performance level is not specified by the manufacturer, then this may be deduced from the product description and
documentation and what the user may reasonably expect from the equipment if used as intended.
Performance criterion C:
The equipment shall function according to the manufacturer specifications before and after the tests. No degradation of
performance or loss of function is allowed below the performance level specified by the manufacturer when the
equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then this may be
deduced from the product description and documentation and what the user may reasonably expect from the equipment
if used as intended.
During the application of the test, temporary loss of function is allowed but after the test the equipment shall restore to
the normal functionality without replacement of components, manual rebooting or human intervention.
The equipment shall sustain the test without permanent structural or mechanical damage.
Performance criterion D:
This performance criterion applies to the enclosure of the equipment. No corrosion traces (e.g. rust) or deterioration of
the enclosure shall occur at the end of the test.
4.3 Specification T 6.1: Totally weatherprotected locations
The tests specifications T 6.1 of the present document shall apply to equipment, depending on the selected IEC
mechanical class, installed in totally weatherprotected, heated and ventilated locations following warm-up on board
engine-powered vessels but excluding refrigerated cargo spaces, machinery spaces and locations containing equipment
dissipating considerable amounts of heat. This class does not cover Warm Damp and Warm Damp Equable climates.
See tables 1 and 4.
4.4 Specification T 6.2: Partly weatherprotected locations
The tests specifications T 6.2 of the present document shall apply to equipment, depending on the selected IEC the
mechanical class chosen, to equipment installed in any location on board engine-powered vessels - excluding
refrigerated cargo spaces. The class applies in all climates with the exception of Cold climates and areas with abnormal
rain intensities and hurricanes. The equipment may occasionally be subjected to heavy seas, See tables 2, 4 and 5.
4.5 Specification T 6.3: Non-weatherprotected locations
The tests specifications T 6.3 of the present document shall apply to equipment to equipment installed in any location
on board engine-powered vessels, including refrigerated cargo spaces. This class applies in all climates including areas
with abnormal rain intensities and hurricanes. The equipment may also be subjected to heavy seas, depending on the
selected IEC mechanical class, see tables 3, 4 and 5.
ETSI
---------------------- Page: 8 ----------------------
9 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
4.6 Specification T 6.1: Totally weatherprotected locations climatic test
This specification in table 1 shall apply to a totally weatherprotected use in ships excluding described in ETSI EN 300 019-1-6 [1]. Warm Damp and Warm Damp Equable
climates, see tables 1 and 4.
Table 1: Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T6.1: Ship, totally weatherprotected locations
Class 6.1
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity Criterion
low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad/Ae: Cold A 1
Air temperature high (°C) +40 +40 16 h IEC 60068-2-2 [3] Bb/Bd/Be: Dry heat A 2
change air/water (°C) no
surface high (°C) no
low (%) 10 none 3
relative high; (%) 95 93 96 h IEC 60068-2-78 [4] Cb: Damp heat A 4
slow temperature change (°C) +30 +30 steady state
Humidity high; (%) no
rapid temperature change (°C)
absolute 3no
high; (g/m )
rapid temperature change (°C)
Air speed (m/s) no
temperature high (°C) +30 none 3
low (°C) no
rain intensity (mm/min) no
Water 3
volume (m /min)
pressure (kPa)
other sources velocity (m/s) no
wetness no
Radiation solar 2no
(W/m )
heat 2no
(W/m )
sulphur 30,1 none 5
SO (mg/m )
2
30,01 none 5
HS (mg/m )
2
Chemically chlorine sea salts negligible
active 30,1 none 5
HCI (mg/m )
substances nitrogen 30,1 none 5
NO (mg/m )
x
30,3 none 5
NH (mg/m )
3
hydrogen fluoride 30,003 none 5
HF (mg/m )
ozone 30,01 none 5
O (mg/m )
3
ETSI
---------------------- Page: 9 ----------------------
10 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.1: Ship, totally weatherprotected locations
Class 6.1
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity Criterion
Mechanically dust sedimentation negligible
active sand in air no
substances soot deposit no
Flora and micro organisms negligible
Fauna rodents, insects negligible
no: This condition does not occur in this class.
none: See note for detail on why test severity is not required.
NOTE 1: (Air temperature, low). The characteristic severity can be used as a cold start-up temperature, but it may be modified by the product specification. The equipment under test shall remain
operational throughout this test, except for the cold start-up test which shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high). If two temperatures are given, the higher test temperature includes heat trap effect of direct solar radiation on equipment. The equipment under test shall remain
operational throughout this test, except for the start-up at high temperature, which shall commence once high temperature stability is achieved.
NOTE 3: As there is no IEC 60068-2 [i.2] test method for this parameter, no tests are defined.
NOTE 4: (Humidity, relative, high, slow temperature change). These severities are the nearest preferred values in IEC 60068-2-78 [4] Test Cb. The minor differences both in temperature and in humidity
conditions are considered to be insignificant.
NOTE 5: (Chemically active substances). The characteristic severities are maximum values. For chemically active substances the characteristics severities should be considered when choosing
components and materials. No test is recommended in the present document.
4.7 Specification T 6.2: Partly weatherprotected locations climatic test
This specification shall apply to use in ships excluding Cold Climate and extreme weather conditions, see tables 2, 4 and 5.
Table 2: Test specification T 6.2: Partly weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (°C) -25 -25 16 h IEC 60068-2-1 [2] Ab/Ad: Cold A 1
Air temperature high (°C) +70 +70 or +85 16 h IEC 60068-2-2 [3] Bb/Bd: Dry heat A 2
change gradual (°C) -25/+40 -25/+40 5 cycles IEC 60068-2-14 [5] Nb: Change of A 3
(°C/min) 3 3 t = 3 h temperature
1
4
change air/water (°C) +40/+5 none
surface high (°C) +70 none A 5
ETSI
---------------------- Page: 10 ----------------------
11 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (%) 10 none 6
relative high; (%) 95 93 96 h IEC 60068-2-78 [4] Cb: Damp heat A 7
slow temperature change (°C) +45 +40 steady state
Humidity high; (%) 95 none 8
rapid temperature change (°C) -25/+35
absolute 3 60 A 9
high; (g/m )
+70/+15
rapid temperature change (°C)
90 to 100 6 cycles IEC 60068-2-30 [6] Db: Damp heat
(%)
+55 cyclic, variant 2
(°C)
Air speed (m/s) 30 none 6
temperature high (°C) +35 none 6
low (°C) freezing point none 10
rain intensity (mm/min) 6 11
Water 3 0,01 2 IEC 60068-2-18 [7] Rb: Impacting A
volume (m /min) 1 min/m
90 water
pressure (kPa) or
method 1.2
5 min
other sources velocity (m/s) 3 none 12
wetness wet surfaces none 13
Radiation solar 2 1 120 none 14
(W/m )
heat 2 1 200 none 14
(W/m )
sulphur 31,0 none 15
SO (mg/m )
2
30,5 none 15
HS (mg/m )
2
Chemically salts mist yes none 15
active chlorine 330 none 15
sea salts (kg/m )
substances 30,5 none 15
HCI (mg/m )
nitrogen 31,0 none 15
NO (mg/m )
x
33,0 none 15
NH (mg/m )
3
hydrogen fluoride 30,03 none 15
HF (mg/m )
ozone 30,1 none 15
O (mg/m )
3
Mechanically dust 23,0 none 16
sedimentation (mg/(m h))
active sand in air 30,1 none 16
(mg/m )
substances soot deposit yes none 16
Flora and micro organisms mould, fungus etc. none 17
Fauna rodents, insects rodents, etc. none 17
no: This condition does not occur in this class.
none: See note for detail on why test severity is not required.
ETSI
---------------------- Page: 11 ----------------------
12 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
NOTE 1: (Air temperature, low). The characteristic severity can be used as a cold start-up temperature, but it may be modified by the product specification. The equipment under test shall remain
operational throughout this test, except for the cold start-up test which shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high). If two temperatures are given, the higher test temperature includes heat trap effect of direct solar radiation on equipment. The equipment under test shall remain
operational throughout this test, except for the start-up at high temperature, which shall commence once high temperature stability is achieved.
NOTE 3: (Air temperature, change, gradual). IEC 60068-2-14 [5] Test Nb has been chosen with characteristic severity. The equipment function shall be monitored throughout the test.
NOTE 4: (Air temperature, change, air/water). This condition is included in the test IEC 60068-2-14 [5] Test Nb.
NOTE 5: (Air temperature, surface, high). There is no suitable IEC 60068-2 [i.2] test method for this parameter. This phenomenon should be taken into account when selecting materials.
NOTE 6: As there is no IEC 60068-2 [i.2] test method for this parameter, no tests are defined.
NOTE 7: (Humidity, relative, high, slow temperature change). These severities are the nearest preferred values in IEC 60068-2-78 [4] Test Cb. The minor differences both in temperature and in
humidity conditions are considered to be insignificant.
NOTE 8: (Humidity, relative, high, rapid temperature change). Rapid temperature change is a relevant parameter and therefore equipment should be designed with this requirement in mind. The
wetting effect is included in IEC 60068-2-30 [6] Test Db.
NOTE 9: (Humidity, absolute, rapid temperature change). For rapid change of temperature IEC 60068-2-30 [6] Test Db, Variant 2 is recommended.
NOTE 10: (Water, temperature, low). The cooling effect of the low temperature of the rain is included in IEC 60068-2-14 [5] Test Nb.
NOTE 11: (Water, rain). IEC 60068-2-18 [7] Test Rb method 1.2 has been chosen even though it does not imitate normal rain. It is a simple hand-held shower test, which is easy to perform and can
demonstrate that the specimen design is adequately toleranced to survive this condition. The greater of the two given durations should be used.
NOTE 12: (Water, other sources). The effect of water is covered by IEC 60068-2-18 [7] Test Rb. This test does not demonstrate the mechanical shock caused by water waves. In IEC 60068-2 [i.2]
series there is no suitable test for this, but the effect has to be considered in the design of equipment. The corrosion effect of sea water should be considered when choosing m
...
SLOVENSKI STANDARD
oSIST prEN 300 019-2-6 V3.0.7:2023
01-oktober-2023
Okoljski inženiring (EE) - Okoljski pogoji in preskusi okoljskih vplivov na
telekomunikacijsko opremo - 2. del: Specifikacija preskusov vplivov okolja - 6.
poddel: Ladijsko okolje
Environmental Engineering (EE) - Environmental conditions and environmental tests for
telecommunications equipment - Part 2: Specification of environmental tests - Sub-part
6: Ship environments
Ta slovenski standard je istoveten z: ETSI EN 300 019-2-6 V3.0.7 (2023-07)
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
oSIST prEN 300 019-2-6 V3.0.7:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
---------------------- Page: 2 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
EUROPEAN STANDARD
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2: Specification of environmental tests;
Sub-part 6: Ship environments
---------------------- Page: 3 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
2 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Reference
REN/EE-017011
Keywords
environment, maritime, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - APE 7112B
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° w061004871
Important notice
The present document can be downloaded from:
https://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the prevailing version of an ETSI
deliverable is the one made publicly available in PDF format at www.etsi.org/deliver.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
https://portal.etsi.org/TB/ETSIDeliverableStatus.aspx
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
If you find a security vulnerability in the present document, please report it through our
Coordinated Vulnerability Disclosure Program:
https://www.etsi.org/standards/coordinated-vulnerability-disclosure
Notice of disclaimer & limitation of liability
The information provided in the present deliverable is directed solely to professionals who have the appropriate degree of
experience to understand and interpret its content in accordance with generally accepted engineering or
other professional standard and applicable regulations.
No recommendation as to products and services or vendors is made or should be implied.
In no event shall ETSI be held liable for loss of profits or any other incidental or consequential damages.
Any software contained in this deliverable is provided "AS IS" with no warranties, express or implied, including but not
limited to, the warranties of merchantability, fitness for a particular purpose and non-infringement of intellectual property
rights and ETSI shall not be held liable in any event for any damages whatsoever (including, without limitation, damages
for loss of profits, business interruption, loss of information, or any other pecuniary loss) arising out of or related to the use
of or inability to use the software.
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and
microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© ETSI 2023.
All rights reserved.
ETSI
---------------------- Page: 4 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
3 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Definition of terms, symbols and abbreviations . 7
3.1 Terms . 7
3.2 Symbols . 7
3.3 Abbreviations . 7
4 Environmental test specification . 7
4.0 General . 7
4.1 Equipment setup and configuration . 7
4.2 Performance criteria . 8
4.3 Specification T 6.1: Totally weatherprotected locations . 8
4.4 Specification T 6.2: Partly weatherprotected locations . 8
4.5 Specification T 6.3: Non-weatherprotected locations. 8
4.6 Specification T 6.1: Totally weatherprotected locations climatic test . 9
4.7 Specification T 6.2: Partly weatherprotected locations climatic test . 10
4.8 Specification T 6.3: Non-weatherprotected locations climatic tests . 13
4.9 Specification T 6.1, T 6.2 and T 6.3: protected and partly protected installation, mechanical tests . 15
Annex A (informative): Bibliography . 18
History . 19
ETSI
---------------------- Page: 5 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
4 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Intellectual Property Rights
Essential patents
IPRs essential or potentially essential to normative deliverables may have been declared to ETSI. The declarations
pertaining to these essential IPRs, if any, are publicly available for ETSI members and non-members, and can be
found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to
ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the
ETSI Web server (https://ipr.etsi.org/).
Pursuant to the ETSI Directives including the ETSI IPR Policy, no investigation regarding the essentiality of IPRs,
including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not
referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become,
essential to the present document.
Trademarks
The present document may include trademarks and/or tradenames which are asserted and/or registered by their owners.
ETSI claims no ownership of these except for any which are indicated as being the property of ETSI, and conveys no
right to use or reproduce any trademark and/or tradename. Mention of those trademarks in the present document does
not constitute an endorsement by ETSI of products, services or organizations associated with those trademarks.
DECT™, PLUGTESTS™, UMTS™ and the ETSI logo are trademarks of ETSI registered for the benefit of its
Members. 3GPP™ and LTE™ are trademarks of ETSI registered for the benefit of its Members and of the 3GPP
Organizational Partners. oneM2M™ logo is a trademark of ETSI registered for the benefit of its Members and of the
®
oneM2M Partners. GSM and the GSM logo are trademarks registered and owned by the GSM Association.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 2, sub-part 6 of a multi-part deliverable covering the Environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests";
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
ETSI
---------------------- Page: 6 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
5 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Part 2-0 [i.1] forms a general overview of part 2. The present document deals with ship environments.
Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa
Modal verbs terminology
In the present document "shall", "shall not", "should", "should not", "may", "need not", "will", "will not", "can" and
"cannot" are to be interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of
provisions).
"must" and "must not" are NOT allowed in ETSI deliverables except when used in direct citation.
ETSI
---------------------- Page: 7 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
6 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
1 Scope
The present document specifies test severities and methods for the verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to the use of telecommunication equipment installed permanently or
temporarily in ships and cover the environments and the vessels stated in ETSI EN 300 019-1-6 [1].
2 References
2.1 Normative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
https://docbox.etsi.org/Reference/.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-6: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-6: Classification of environmental
conditions; Ship environments".
[2] IEC 60068-2-1 (03-2007): "Environmental testing - Part 2-1: Tests - Test A: Cold".
[3] IEC 60068-2-2 (07-2007): "Environmental testing - Part 2-2: Tests - Test B: Dry heat".
[4] IEC 60068-2-78 (10-2012): "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat,
steady state".
[5] IEC 60068-2-14 (01-2009): "Environmental testing - Part 2-14: Tests - Test N: Change of
temperature".
[6] IEC 60068-2-30 (08-2005): "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[7] IEC 60068-2-18 (03-2017): "Environmental testing - Part 2-18: Tests - Test R and guidance:
Water".
[8] IEC 60068-2-6 (12-2007): "Environmental testing - Part 2-6: Tests - Test Fc: Vibration
(sinusoidal)".
[9] IEC 60068-2-27 (02-2008): "Environmental testing - Part 2-27: Tests - Test Ea and guidance:
Shock".
2.2 Informative references
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
referenced document (including any amendments) applies.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
ETSI
---------------------- Page: 8 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
7 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2: Specification of environmental
tests; Sub-part 0: Introduction".
[i.2] IEC 60068-2 (all parts): "Environmental testing - Part 2: Tests".
[i.3] ETSI EN 300 019-1-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-0: Classification of environmental
conditions; Introduction".
[i.4] IEC 60068-2-52:2017: "Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic
(sodium chloride solution)".
[i.5] IEC 60068-2-68:1994: "Environmental testing - Part 2-68: Tests - Test L: Dust and sand".
3 Definition of terms, symbols and abbreviations
3.1 Terms
For the purposes of the present document, the terms given in ETSI EN 300 019-1-0 [i.3] apply.
3.2 Symbols
For the purposes of the present document, the symbols given in ETSI EN 300 019-1-0 [i.3] apply.
3.3 Abbreviations
For the purposes of the present document, the abbreviations given in ETSI EN 300 019-1-0 [i.3] apply.
4 Environmental test specification
4.0 General
The equipment shall be tested in its operational state throughout the test conditions described in the present document.
The detailed descriptions of the environmental conditions shall refer to clauses 4 and 5 of ETSI EN 300 019-1-6 [1].
ETSI EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multi-part deliverable.
4.1 Equipment setup and configuration
The equipment shall be tested in its operational state throughout the test conditions described in the present document
unless otherwise stated. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
ETSI
---------------------- Page: 9 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
8 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
4.2 Performance criteria
The following performance criteria shall apply in the tests defined by the present document.
Performance criterion A:
The equipment shall function according to the manufacturer specifications before, during and after the tests. No
degradation of performance or loss of function is allowed below the performance level specified by the manufacturer
when the equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then
this may be deduced from the product description and documentation and what the user may reasonably expect from the
equipment if used as intended.
Performance criterion B:
The equipment shall function according to the manufacturer specifications before and after the tests. During the test it is
not required to monitor the equipment functionality. No degradation of performance or loss of function is allowed
below the performance level specified by the manufacturer when the equipment is used as intended. If the minimum
performance level is not specified by the manufacturer, then this may be deduced from the product description and
documentation and what the user may reasonably expect from the equipment if used as intended.
Performance criterion C:
The equipment shall function according to the manufacturer specifications before and after the tests. No degradation of
performance or loss of function is allowed below the performance level specified by the manufacturer when the
equipment is used as intended. If the minimum performance level is not specified by the manufacturer, then this may be
deduced from the product description and documentation and what the user may reasonably expect from the equipment
if used as intended.
During the application of the test, temporary loss of function is allowed but after the test the equipment shall restore to
the normal functionality without replacement of components, manual rebooting or human intervention.
The equipment shall sustain the test without permanent structural or mechanical damage.
Performance criterion D:
This performance criterion applies to the enclosure of the equipment. No corrosion traces (e.g. rust) or deterioration of
the enclosure shall occur at the end of the test.
4.3 Specification T 6.1: Totally weatherprotected locations
The tests specifications T 6.1 of the present document shall apply to equipment, depending on the selected IEC
mechanical class, installed in totally weatherprotected, heated and ventilated locations following warm-up on board
engine-powered vessels but excluding refrigerated cargo spaces, machinery spaces and locations containing equipment
dissipating considerable amounts of heat. This class does not cover Warm Damp and Warm Damp Equable climates.
See tables 1 and 4.
4.4 Specification T 6.2: Partly weatherprotected locations
The tests specifications T 6.2 of the present document shall apply to equipment, depending on the selected IEC the
mechanical class chosen, to equipment installed in any location on board engine-powered vessels - excluding
refrigerated cargo spaces. The class applies in all climates with the exception of Cold climates and areas with abnormal
rain intensities and hurricanes. The equipment may occasionally be subjected to heavy seas, See tables 2, 4 and 5.
4.5 Specification T 6.3: Non-weatherprotected locations
The tests specifications T 6.3 of the present document shall apply to equipment to equipment installed in any location
on board engine-powered vessels, including refrigerated cargo spaces. This class applies in all climates including areas
with abnormal rain intensities and hurricanes. The equipment may also be subjected to heavy seas, depending on the
selected IEC mechanical class, see tables 3, 4 and 5.
ETSI
---------------------- Page: 10 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
9 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
4.6 Specification T 6.1: Totally weatherprotected locations climatic test
This specification in table 1 shall apply to a totally weatherprotected use in ships excluding described in ETSI EN 300 019-1-6 [1]. Warm Damp and Warm Damp Equable
climates, see tables 1 and 4.
Table 1: Test specification T 6.1: Totally weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T6.1: Ship, totally weatherprotected locations
Class 6.1
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity Criterion
low (°C) +5 +5 16 h IEC 60068-2-1 [2] Ab/Ad/Ae: Cold A 1
Air temperature high (°C) +40 +40 16 h IEC 60068-2-2 [3] Bb/Bd/Be: Dry heat A 2
change air/water (°C) no
surface high (°C) no
low (%) 10 none 3
relative high; (%) 95 93 96 h IEC 60068-2-78 [4] Cb: Damp heat A 4
slow temperature change (°C) +30 +30 steady state
Humidity high; (%) no
rapid temperature change (°C)
absolute 3no
high; (g/m )
rapid temperature change (°C)
Air speed (m/s) no
temperature high (°C) +30 none 3
low (°C) no
rain intensity (mm/min) no
Water 3
volume (m /min)
pressure (kPa)
other sources velocity (m/s) no
wetness no
Radiation solar 2no
(W/m )
heat 2no
(W/m )
sulphur 30,1 none 5
SO (mg/m )
2
30,01 none 5
HS (mg/m )
2
Chemically chlorine sea salts negligible
active 30,1 none 5
HCI (mg/m )
substances nitrogen 30,1 none 5
NO (mg/m )
x
30,3 none 5
NH (mg/m )
3
hydrogen fluoride 30,003 none 5
HF (mg/m )
ozone 30,01 none 5
O (mg/m )
3
ETSI
---------------------- Page: 11 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
10 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.1: Ship, totally weatherprotected locations
Class 6.1
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity Criterion
Mechanically dust sedimentation negligible
active sand in air no
substances soot deposit no
Flora and micro organisms negligible
Fauna rodents, insects negligible
no: This condition does not occur in this class.
none: See note for detail on why test severity is not required.
NOTE 1: (Air temperature, low). The characteristic severity can be used as a cold start-up temperature, but it may be modified by the product specification. The equipment under test shall remain
operational throughout this test, except for the cold start-up test which shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high). If two temperatures are given, the higher test temperature includes heat trap effect of direct solar radiation on equipment. The equipment under test shall remain
operational throughout this test, except for the start-up at high temperature, which shall commence once high temperature stability is achieved.
NOTE 3: As there is no IEC 60068-2 [i.2] test method for this parameter, no tests are defined.
NOTE 4: (Humidity, relative, high, slow temperature change). These severities are the nearest preferred values in IEC 60068-2-78 [4] Test Cb. The minor differences both in temperature and in humidity
conditions are considered to be insignificant.
NOTE 5: (Chemically active substances). The characteristic severities are maximum values. For chemically active substances the characteristics severities should be considered when choosing
components and materials. No test is recommended in the present document.
4.7 Specification T 6.2: Partly weatherprotected locations climatic test
This specification shall apply to use in ships excluding Cold Climate and extreme weather conditions, see tables 2, 4 and 5.
Table 2: Test specification T 6.2: Partly weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (°C) -25 -25 16 h IEC 60068-2-1 [2] Ab/Ad: Cold A 1
Air temperature high (°C) +70 +70 or +85 16 h IEC 60068-2-2 [3] Bb/Bd: Dry heat A 2
change gradual (°C) -25/+40 -25/+40 5 cycles IEC 60068-2-14 [5] Nb: Change of A 3
(°C/min) 3 3 t = 3 h temperature
1
4
change air/water (°C) +40/+5 none
surface high (°C) +70 none A 5
ETSI
---------------------- Page: 12 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
11 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
low (%) 10 none 6
relative high; (%) 95 93 96 h IEC 60068-2-78 [4] Cb: Damp heat A 7
slow temperature change (°C) +45 +40 steady state
Humidity high; (%) 95 none 8
rapid temperature change (°C) -25/+35
absolute 3 60 A 9
high; (g/m )
+70/+15
rapid temperature change (°C)
90 to 100 6 cycles IEC 60068-2-30 [6] Db: Damp heat
(%)
+55 cyclic, variant 2
(°C)
Air speed (m/s) 30 none 6
temperature high (°C) +35 none 6
low (°C) freezing point none 10
rain intensity (mm/min) 6 11
Water 3 0,01 2 IEC 60068-2-18 [7] Rb: Impacting A
volume (m /min) 1 min/m
90 water
pressure (kPa) or
method 1.2
5 min
other sources velocity (m/s) 3 none 12
wetness wet surfaces none 13
Radiation solar 2 1 120 none 14
(W/m )
heat 2 1 200 none 14
(W/m )
sulphur 31,0 none 15
SO (mg/m )
2
30,5 none 15
HS (mg/m )
2
Chemically salts mist yes none 15
active chlorine 330 none 15
sea salts (kg/m )
substances 30,5 none 15
HCI (mg/m )
nitrogen 31,0 none 15
NO (mg/m )
x
33,0 none 15
NH (mg/m )
3
hydrogen fluoride 30,03 none 15
HF (mg/m )
ozone 30,1 none 15
O (mg/m )
3
Mechanically dust 23,0 none 16
sedimentation (mg/(m h))
active sand in air 30,1 none 16
(mg/m )
substances soot deposit yes none 16
Flora and micro organisms mould, fungus etc. none 17
Fauna rodents, insects rodents, etc. none 17
no: This condition does not occur in this class.
none: See note for detail on why test severity is not required.
ETSI
---------------------- Page: 13 ----------------------
oSIST prEN 300 019-2-6 V3.0.7:2023
12 Draft ETSI EN 300 019-2-6 V3.0.7 (2023-07)
Environmental parameter Environmental Environmental test specification T6.2: Ship, partly weatherprotected locations
Class 6.2
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Performance Notes
severity criterion
NOTE 1: (Air temperature, low). The characteristic severity can be used as a cold start-up temperature, but it may be modified by the product specification. The equipment under test shall remain
operational throughout this test, except for the cold start-up test which shall commence once low temperature stability is achieved.
NOTE 2: (Air temperature, high). If two temperatures are given, the higher test temperature includes heat trap effect of direct solar radiation on equipment. The equipment under test shall remain
operational throughout this test, except for the start-up at high temperature, which shall commence once high temperature stability is achieved.
NOTE 3: (Air temperature, change, gradual). IEC 60068-2-14 [5] Test Nb has been chosen with characteristic severity. The equipment function shall be monitored throughout the test.
NOTE 4: (Air temperature, change, air/water). This condition is included in the test IEC 60068-2-14 [5] Test Nb.
NOTE 5: (Air temperature, surface, high). There is no suitable IEC 60068-2 [i.2] test method for this parameter. This phenomenon should be taken into account when selecting materials.
NOTE 6: As there is no IEC 60068-2 [i.2] test method for this parameter, no tests are defined.
NOTE 7: (Humidity, relative, high, slow tempera
...