Digital Terminals and Access (DTA); Attachment requirements for Data Terminal Equipment (DTE) to connect to Packet Switched Public Data Networks (PSPDNs) for CCITT Recommendation X.25 interfaces at data signalling rates up to 1 920 kbit/s utilizing interfaces derived from CCITT Recommendations X.21 and X.21 bis

DTBR/DTA-005002

Digitalni terminali in dostop (DTA) - Priključitvene zahteve za podatkovno terminalsko opremo (DTE) za priključevanje na paketno komutirana javna podatkovna omrežja (PSPDNs) za vmesnike po priporočilu CCITT, X.25, s podatkovnimi signalizacijskimi hitrostmi do 1 920 kbit/s, ki uporabljajo vmesnike po priporočilih CCITT, X.21 in X.21 bis

General Information

Status
Published
Publication Date
29-Jan-1997
Current Stage
12 - Completion
Due Date
13-Feb-1996
Completion Date
30-Jan-1997
Mandate

Buy Standard

Standardization document
TBR 002 E1:2004
English language
60 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST TBR 002 E1:2004
01-oktober-2004
'LJLWDOQLWHUPLQDOLLQGRVWRS '7$ 3ULNOMXþLWYHQH]DKWHYH]DSRGDWNRYQR
WHUPLQDOVNRRSUHPR '7( ]DSULNOMXþHYDQMHQDSDNHWQRNRPXWLUDQDMDYQD
SRGDWNRYQDRPUHåMD 363'1V ]DYPHVQLNHSRSULSRURþLOX&&,77;V
SRGDWNRYQLPLVLJQDOL]DFLMVNLPLKLWURVWPLGRNELWVNLXSRUDEOMDMRYPHVQLNH
SRSULSRURþLOLK&&,77;LQ;ELV
Digital Terminals and Access (DTA); Attachment requirements for Data Terminal
Equipment (DTE) to connect to Packet Switched Public Data Networks (PSPDNs) for
CCITT Recommendation X.25 interfaces at data signalling rates up to 1 920 kbit/s
utilizing interfaces derived from CCITT Recommendations X.21 and X.21 bis
Ta slovenski standard je istoveten z: TBR 002 Edition 1
ICS:
33.040.40 Podatkovna komunikacijska Data communication
omrežja networks
SIST TBR 002 E1:2004 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST TBR 002 E1:2004

---------------------- Page: 2 ----------------------

SIST TBR 002 E1:2004
TECHNICAL TBR 2
BASIS for January 1997
REGULATION
Source: ETSI TC-TE Reference: DTBR/TE-005002
ICS: 33.020, 33.040.40
Key words: PDN, testing, type approval, X.25
Attachment requirements for Data Terminal Equipment (DTE)
to connect to Packet Switched Public Data Networks (PSPDNs)
for CCITT Recommendation X.25 interfaces at
data signalling rates up to 1 920 kbit/s
utilizing interfaces derived from
CCITT Recommendations X.21 and X.21 bis
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
Postal address: F-06921 Sophia Antipolis CEDEX - FRANCE
Office address: 650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
X.400: c=fr, a=atlas, p=etsi, s=secretariat - Internet: secretariat@etsi.fr
Tel.: +33 4 92 94 42 00 - Fax: +33 4 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1997. All rights reserved.

---------------------- Page: 3 ----------------------

SIST TBR 002 E1:2004
Page 2
TBR 2: January 1997
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

---------------------- Page: 4 ----------------------

SIST TBR 002 E1:2004
Page 3
TBR 2: January 1997
Contents
Foreword .7
Introduction.7
1 Scope .9
2 Normative references.10
3 Definitions and abbreviations .11
3.1 Definitions .11
3.2 Abbreviations .11
4 Modes of operation and signalling rates.11
4.1 Types of operation .11
4.2 Data signalling rate .11
5 Safety and EMC requirements .11
5.1 Safety requirements.11
5.2 EMC requirements.11
6 Electrical, mechanical, and access control protocol requirements .12
6.1 General characteristics .12
6.1.1 Generator presentations.12
6.1.1.1 Balanced generator .12
6.1.1.2 Unbalanced generator .12
6.1.2 Receiver presentations.12
6.1.2.1 Balanced receiver.12
6.1.2.2 Unbalanced receiver.12
6.2 Connector characteristics and contact number assignments.12
6.2.1 Attachment to a DCE interface presented on a 25-pole connector.12
6.2.1.1 Connector .12
6.2.1.2 Contact number assignments.12
6.2.2 Attachment to a DCE interface presented on a 26-pole connector.13
6.2.2.1 Connector .13
6.2.2.2 Contact number assignments.13
6.2.3 Attachment to a DCE interface presented on a 37-pole connector.13
6.2.3.1 Connector .13
6.2.3.2 Contact number assignments.13
6.2.4 Attachment to a DCE interface presented on a 34-pole connector.13
6.2.4.1 Connector .13
6.2.4.2 Contact number assignments.14
6.2.5 Attachment to a DCE interface presented on a 15-pole connector.14
6.2.5.1 Connector .14
6.2.5.2 Contact number assignments.14
6.3 Electrical requirements .14
6.3.1 Requirements for attachment to CCITT Recommendation V.10
interchange circuits .15
6.3.1.1 Generator open circuit output voltage.15
6.3.1.2 Generator terminated output voltage.15
6.3.1.3 Generator output rise time.16
6.3.1.4 Generator polarities .16
6.3.2 Requirements for attachment to CCITT Recommendation V.11
interchange circuits .17
6.3.2.1 Generator open circuit output voltage.17
6.3.2.2 Generator terminated output voltage.17
6.3.2.3 Generator output rise time.18
6.3.2.4 Generator polarities .19

---------------------- Page: 5 ----------------------

SIST TBR 002 E1:2004
Page 4
TBR 2: January 1997
6.3.3 Requirements for attachment to CCITT V.28 interchange circuits. 19
6.3.3.1 Generator open circuit output voltage. 20
6.3.3.2 Generator terminated output voltage . 20
6.3.3.3 Generator output signal transition time . 21
6.3.3.4 Generator polarities. 22
6.3.3.5 Receiver maximum effective shunt capacitance. 22
6.3.4 Requirements for attachment to CCITT Recommendation V.35
interchange circuits. 22
6.3.4.1 Generator open circuit output voltage. 22
6.3.4.2 Generator terminated output voltage . 23
6.3.4.3 Generator output rise time . 23
6.3.4.4 Generator polarities. 24
6.4 X.25 link layer (layer 2) requirements. 24
6.5 X.25 packet layer (layer 3) requirements . 24
7 TBR Test Specification . 25
7.1 Conditions of test. 25
7.1.1 Environment for tests. 25
7.1.2 Power supply limitations . 25
7.1.3 Test condition . 25
7.1.4 Test point. 25
7.1.5 Bit patterns. 25
7.1.6 Signal element timing . 25
7.1.7 Data signalling rates . 25
7.1.8 Interchange circuits presentation. 26
7.1.9 Physical layer tests . 26
7.1.9.1 Verification of the electrical characteristics. 26
7.1.9.2 Identically implemented circuits . 26
7.1.9.3 Fixed state generators . 26
7.2 Test descriptions for connector characteristics and contact number assignments . 26
7.2.1 25-pole connector. 26
7.2.1.1 Connector characteristics . 26
7.2.1.2 Contact number assignments . 26
7.2.2 26-pole connector. 26
7.2.2.1 Connector characteristics . 26
7.2.2.2 Contact number assignments . 27
7.2.2.2.1 Connection to a DCE presenting
CCITT Recommendation V.10 or V.11
electrical characteristics. 27
7.2.2.2.2 Connection to a DCE presenting
CCITT Recommendation V.28
electrical characteristics. 27
7.2.3 37-pole connector. 27
7.2.3.1 Connector characteristics . 27
7.2.3.2 Contact number assignments . 27
7.2.4 34-pole connector. 27
7.2.4.1 Connector characteristics . 27
7.2.4.2 Contact number assignments . 27
7.2.5 15-pole connector. 28
7.2.5.1 Connector characteristics . 28
7.2.5.2 Contact number assignments . 28
7.3 Test descriptions for attachment to CCITT V.10 interchange circuits. 28
7.3.1 Generator characteristics . 28
7.3.1.1 Generator open circuit output voltage. 28
7.3.1.2 Generator terminated output voltage . 29
7.3.1.3 Generator output rise time . 30
7.4 Test descriptions for attachment to CCITT Recommendation V.11 interchange circuits . 31
7.4.1 Generator characteristics . 31
7.4.1.1 Generator open circuit output voltage. 31
7.4.1.2 Generator terminated output voltage . 32
7.4.1.3 Generator output rise time . 33
7.5 Test descriptions for attachment to CCITT V.28 interchange circuits. 34
7.5.1 Generator characteristics . 34

---------------------- Page: 6 ----------------------

SIST TBR 002 E1:2004
Page 5
TBR 2: January 1997
7.5.1.1 Generator open circuit output voltage.34
7.5.1.2 Generator terminated output voltage.35
7.5.1.3 Generator output signal transition time.36
7.5.2 Receiver characteristics .37
7.5.2.1 Receiver effective shunt capacitance.37
7.6 Test descriptions for attachment to CCITT Recommendation V.35 interchange circuits.37
7.6.1 Generator characteristics .37
7.6.1.1 Generator open circuit output voltage.37
7.6.1.2 Generator terminated output voltage.39
7.6.1.3 Generator output rise time.40
7.7 TBR 2 Test Case Selection Expression Definition table.41
7.8 Test case Index .42
Annex A (normative): The TBR Requirements Table (TBR-RT).43
A.1 Introduction to the TBR-RT .43
A.2 Format of the tables .43
A.3 Notations used in the TBR-RT .44
A.3.1 Status notations .44
A.3.2 Support answer notations .44
A.4 The TBR Requirement Tables .45
A.4.1 Connection to a DCE presenting an ISO 2110 [8] (25-pole) connector.45
A.4.2 Connection to a DCE presenting an ISO/IEC 11569 (26-pole) connector.46
A.4.3 Connection to a DCE presenting an ISO 4902 (37-pole) connector.50
A.4.4 Connection to a DCE presenting an ISO 2593 (34-pole) connector.52
A.4.5 Connection to a DCE presenting an ISO 4903 [12] (15-pole) connector.55
Annex B (normative): Physical layer implementation extra information for testing (PIXIT).57
Annex C (informative): Explanatory note to TBR .58
C.1 Purpose of TBR 2.58
C.2 Title and scope.58
C.3 Relationship to NET 2 .58
C.4 NET to TBR conversion process.58
C.5 Means of connection to the DCE.58
Annex D (informative): Bibliography.59
History.60

---------------------- Page: 7 ----------------------

SIST TBR 002 E1:2004
Page 6
TBR 2: January 1997
Blank page

---------------------- Page: 8 ----------------------

SIST TBR 002 E1:2004
Page 7
TBR 2: January 1997
Foreword
This Technical Basis for Regulation (TBR) has been produced by the Terminal Equipment (TE) Technical
Committee of the European Telecommunication Standards Institute (ETSI).
Introduction
The physical layer requirements contained in this TBR are a superset of the physical layer requirements
contained in TBR 1 (see annex D), which relate to the connection of a terminal to a Circuit Switched Public
Data Network (CSPDN) using CCITT Recommendation X.21 [7]. It is recommended that a demonstration
of compliance with these requirements be accepted as a demonstration of compliance with the relevant
parts of TBR 1 for the purpose of determining conformity with that TBR, and vice versa.

---------------------- Page: 9 ----------------------

SIST TBR 002 E1:2004
Page 8
TBR 2: January 1997
Blank page

---------------------- Page: 10 ----------------------

SIST TBR 002 E1:2004
Page 9
TBR 2: January 1997
1 Scope
This Technical Basis for Regulation (TBR) specifies the technical characteristics (electrical and
mechanical interface requirements) and access control protocol to be provided by packet mode terminal
equipment intended for connection to a dedicated interface of a Packet Switched Public Data Network
(PSPDN) using CCITT Recommendation X.25 [1], [2] and [3] making use of Link Access Procedure
Balanced (Modulo 8 operation) (LAPB) and Link Access Procedure Balanced (Modulo 128 operation)
(LAPB Extended) modes of operation.
The objective of this TBR is to ensure that no disturbance occurs to the public network, and to ensure
interworking between network and terminal, but without any guarantee of terminal operation and end to
end operability across networks.
This TBR contains the minimum set of requirements derived from CCITT Recommendation X.25 [1], [2]
and [3] in accordance with prior European harmonization documents (NET 2, see annex D). The
requirements of this TBR are suitable for testing terminal equipment for connection to
CCITT Recommendation X.25 [1], [2] and [3] (1980, 1984, and 1988) PSPDNs. Terminal equipment that
is capable of either originating only or terminating only, packet level modes of operation have been
included. Data Terminal Equipment (DTE) which satisfies the relevant technical requirements of this TBR
may be connected to every PSPDN, use any of the essential (E) facilities and invoke any of the provided
additional (A) facilities as given in CCITT Recommendation X.2 [4] and [5].
For each requirement in this TBR, a test is given, including measurement methods. Requirements apply
at the public network interface of the terminal equipment, which may be stimulated to perform tests by
additional equipment if necessary. For the purposes of this TBR a terminal equipment comprises of that
apparatus included between a PSPDN Network Termination Point (Data Circuit Terminating Equipment
(DCE)), and the terminal equipment boundary point that delimits the Network to Transport layers as
defined in ITU-T (CCITT Recommendation X.200) subclause 7.5 (Reference model of Open Systems
Interconnection). Equipment in this context is taken to mean either software, firmware or hardware.
Where the packet mode terminal equipment supplied for test does not contain the functions of layers 1, 2
and 3 (as defined in ITU-T (CCITT Recommendation X.200) subclause 7.5 (Reference model of Open
Systems Interconnection)), the terminal's documentation and instructions for use shall state which
additional equipment is required for compliance to this TBR and the additional equipment shall be
submitted for test, as though all the functional layers were provided by the packet terminal equipment.
This TBR also gives guidance on appropriate standards relating to the essential requirements on safety.
Terminal equipment may be subject to additional or alternative attachment requirements in other CTRs
depending on its functionality, in particular if it supports a service which is considered a justified case for
regulation of terminal equipment interworking via the public telecommunications network.

---------------------- Page: 11 ----------------------

SIST TBR 002 E1:2004
Page 10
TBR 2: January 1997
2 Normative references
This TBR incorporates by dated or undated reference, provisions from other publications. These
normative references are cited at the appropriate places in the text and the publications are listed
hereafter. For dated references, subsequent amendments to or revisions of any of these publications are
to apply to this TBR only when incorporated in it by amendment or revision. For undated references the
latest edition of the publication referred to applies.
[1] CCITT Recommendation X.25 (1980): "Interface between Data Terminal
Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals
operating in the packet mode and connected to public data networks by
dedicated circuit".
[2] CCITT Recommendation X.25 (1984): "Interface between Data Terminal
Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals
operating in the packet mode and connected to public data networks by
dedicated circuit".
[3] CCITT Recommendation X.25 (1988): "Interface between Data Terminal
Equipment (DTE) and Data Circuit-terminating Equipment (DCE) for terminals
operating in the packet mode and connected to public data networks by
dedicated circuit".
[4] CCITT Recommendation X.2 (1984): "International data transmission services
and optional user facilities in public data networks".
[5] CCITT Recommendation X.2 (1988): "International data transmission services
and optional user facilities in public data networks and ISDNs".
[6] CCITT Recommendation X.21bis (1988): "Use on public data networks of data
terminal equipment (DTE) which is designed for interfacing to synchronous
V-series modems".
[7] CCITT Recommendation X.21 (1988): "Interface between data terminal
equipment (DTE) and data circuit-terminating equipment (DCE) for synchronous
operation on public data networks".
[8] ISO 2110 (1980): "Information Technology - Data communication - 25-pole
DTE/DCE interface connector and contact number assignments".
[9] ISO/IEC 11569 (1992): "Information Technology - Telecommunications and
information exchange between systems - 26-pole interface connector
mateability dimensions and contact number assignments".
[10] ISO 4902 (1980): "Information Technology - Data communication - 37-pole
DTE/DCE interface connector and contact number assignments".
[11] ISO 2593 (1984): "Information Technology - Telecommunications and
information exchange between systems - 34-pole DTE/DCE interface connector
and contact number assignments".
[12] ISO 4903 Second edition (1989): "Information Technology - Data
communication - 15-pole DTE/DCE interface connector and contact number
assignments".
[13] CCITT Recommendation X.200: "Information technology - Open Systems
Interconnection - Basic reference model: The basic model".

---------------------- Page: 12 ----------------------

SIST TBR 002 E1:2004
Page 11
TBR 2: January 1997
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this TBR, the following definitions apply:
CCITT recommendation X.25 [1] to [3] network: A PSPDN network which offers a
CCITT Recommendation X.25 [1], [2] and [3] DTE/DCE interface providing the (E) facilities for user
classes of service 8-11 as defined in CCITT Recommendation X.2, [4] and [5].
All other definitions are as given in the CCITT series of Recommendations.
3.2 Abbreviations
For the purposes of this TBR, the following abbreviations apply:
CL total effective capacitance associated with the load, measured at the
interchange point
DCE Data Circuit Terminating Equipment
DTE Data Terminal Equipment
EMC Electro-Magnetic Compatibility
hex hexadecimal
IUT Implementation Under Test
LAPB Link Access Procedure Balanced (Modulo 8 operation)
LAPB Extended Link Access Procedure Balanced (Modulo 128 operation)
PIXIT Protocol Implementation Extra Information For Testing
PSPDN Packet Switched Public Data Network
RL total effective resistance associated with the load, measured at the interchange
point
TBR-RT TBR Requirements Table
Vo open-circuit generator voltage
4 Modes of operation and signalling rates
4.1 Types of operation
This TBR is applicable to packet mode terminal equipment intended for connection to a dedicated
interface of a packet switched public data network.
NOTE: The requirements contained in this TBR may be suitable for terminal equipment
intended for connection to a public data network interface using
CCITT Recommendations X.21 [6] or X.21bis [7] interfaces that is not a PSPDN.
4.2 Data signalling rate
This TBR is applicable for packet mode terminal equipment operating at data signalling rates up to and
including 1 920 kbit/s (User Class 59 of CCITT Recommendation X.1, see annex D).
5 Safety and EMC requirements
5.1 Safety requirements
There are no safety requirements under this TBR.
NOTE: Safety requirements are imposed under the Low Voltage Directive (73/23/EEC) and
articles 4 (a) and 4 (b) of Directive 91/263/EEC.
5.2 EMC requirements
There are no EMC requirements under this TBR.

---------------------- Page: 13 ----------------------

SIST TBR 002 E1:2004
Page 12
TBR 2: January 1997
NOTE: General EMC requirements are imposed under EMC Directive (89/336/EEC).
6 Electrical, mechanical, and access control protocol requirements
The requirements of this clause apply at the means of connection to the DCE.
6.1 General characteristics
6.1.1 Generator presentations
6.1.1.1 Balanced generator
In the case of balanced terminal equipment generators, points A and B are defined as the two physical
connections, on the means provided for connection to the DCE, to which the output of a terminal
generator is connected, and point C is the physical connection on the means of connection to the DCE to
which the terminal equipment signal ground may optionally be connected (see figure 5).
6.1.1.2 Unbalanced generator
In the case of unbalanced terminal equipment generators, point A is defined as the physical connection on
the means provided for connection to the DCE, to which the output of a terminal generator is connected,
and point C is the physical connection on the means of connection to the DCE to which the signal ground
associated with that generator is connected.
6.1.2 Receiver presentations
6.1.2.1 Balanced receiver
In the case of balanced terminal equipment receivers, points A' and B' are defined as the two physical
connections, on the means provided for connection to the DCE, to which the input of a terminal receiver is
connected, and point C' is the physical connection on the means of connection to the DCE to which the
terminal equipment signal ground may optionally be connected.
6.1.2.2 Unbalanced receiver
In the case of unbalanced terminal equipment receivers, point A' is defined as the physical connection on
the means provided for connection to the DCE, to which the input of a terminal receiver is connected, and
point C' is the physical connection on the means of connection to the DCE to which the signal ground
associated with that generator is connected.
6.2 Connector characteristics and contact number assignments
The means of connection to the DCE shall conform to either subclause 6.2.1, 6.2.2, 6.2.3 ,6.2.4 or 6.2.5.
6.2.1 Attachment to a DCE interface presented on a 25-pole connector
6.2.1.1 Connector
The means of connection to the DCE shall be a male connector conforming to ISO 2110 [8].
NOTE: This requirement is based upon subclause 1.2 of CCITT Recommendation X.21 bis [6].
Compliance shall be checked by the test given in subclause 7.2.1.1.
Justification: Directive 91/263/EEC, article 4 (d).
6.2.1.2 Contact number assignments
On the means of connection to the DCE, the presentation of the interchange circuits shall be in
accordance with annex A, tables A.1 and A.2 or ta
...

Questions, Comments and Discussion