Amendment 2 - Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers

Amendement 2 - Appareils électrodomestiques et analogues - Sécurité - Partie 2-76: Règles particulières pour les électrificateurs de clôtures

General Information

Status
Published
Publication Date
30-May-2013
Current Stage
DELPUB - Deleted Publication
Completion Date
29-Jun-2018
Ref Project

Relations

Buy Standard

Standard
IEC 60335-2-76:2002/AMD2:2013 - Amendment 2 - Household and similar electrical appliances - Safety - Part 2-76: Particular requirements for electric fence energizers Released:5/31/2013
English and French language
20 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

IEC 60335-2-76


®


Edition 2.0 2013-05



INTERNATIONAL



STANDARD



NORME
INTERNATIONALE
AMENDMENT 2
AMENDEMENT 2

Household and similar electrical appliances – Safety –
Part 2-76: Particular requirements for electric fence energizers

Appareils électrodomestiques et analogues – Sécurité –
Partie 2-76: Règles particulières pour les électrificateurs de clôtures


IEC 60335-2-76:2002/A2:2013

---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED


Copyright © 2013 IEC, Geneva, Switzerland


All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form

or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,

please contact the address below or your local IEC member National Committee for further information.



Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni
utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les

microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.

Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette

publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11
3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch

About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.

About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

Useful links:

IEC publications search - www.iec.ch/searchpub Electropedia - www.electropedia.org
The advanced search enables you to find IEC publications The world's leading online dictionary of electronic and
by a variety of criteria (reference number, text, technical electrical terms containing more than 30 000 terms and
committee,…). definitions in English and French, with equivalent terms in
It also gives information on projects, replaced and additional languages. Also known as the International
withdrawn publications. Electrotechnical Vocabulary (IEV) on-line.

IEC Just Published - webstore.iec.ch/justpublished Customer Service Centre - webstore.iec.ch/csc
Stay up to date on all new IEC publications. Just Published If you wish to give us your feedback on this publication
details all new publications released. Available on-line and or need further assistance, please contact the
also once a month by email. Customer Service Centre: csc@iec.ch.


A propos de la CEI
La Commission Electrotechnique Internationale (CEI) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.

A propos des publications CEI
Le contenu technique des publications de la CEI est constamment revu. Veuillez vous assurer que vous possédez
l’édition la plus récente, un corrigendum ou amendement peut avoir été publié.


Liens utiles:

Recherche de publications CEI - www.iec.ch/searchpub Electropedia - www.electropedia.org
La recherche avancée vous permet de trouver des Le premier dictionnaire en ligne au monde de termes
publications CEI en utilisant différents critères (numéro de électroniques et électriques. Il contient plus de 30 000
référence, texte, comité d’études,…). termes et définitions en anglais et en français, ainsi que
Elle donne aussi des informations sur les projets et les les termes équivalents dans les langues additionnelles.
publications remplacées ou retirées. Egalement appelé Vocabulaire Electrotechnique
International (VEI) en ligne.
Just Published CEI - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications de la CEI.
Just Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur
Disponible en ligne et aussi une fois par mois par email. cette publication ou si vous avez des questions
contactez-nous: csc@iec.ch.

---------------------- Page: 2 ----------------------
IEC 60335-2-76



®



Edition 2.0 2013-05







INTERNATIONAL





STANDARD







NORME



INTERNATIONALE




AMENDMENT 2

AMENDEMENT 2





Household and similar electrical appliances – Safety –

Part 2-76: Particular requirements for electric fence energizers




Appareils électrodomestiques et analogues – Sécurité –

Partie 2-76: Règles particulières pour les électrificateurs de clôtures

















INTERNATIONAL

ELECTROTECHNICAL

COMMISSION


COMMISSION

ELECTROTECHNIQUE

PRICE CODE
INTERNATIONALE

CODE PRIX K


ICS 65.040.99 ISBN 978-2-83220-808-3



Warning! Make sure that you obtained this publication from an authorized distributor.

Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission
Marque déposée de la Commission Electrotechnique Internationale

---------------------- Page: 3 ----------------------
– 2 – 60335-2-76 Amend. 2 © IEC:2013



FOREWORD


This amendment has been prepared by subcommittee 61H: Safety of electrically-operated

farm appliances, of IEC technical committee 61: Safety of household and similar electrical

appliances.


The text of this amendment is based on the following documents:


FDIS Report on voting

61H/287/FDIS 61H/289/RVD


Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of this amendment and the base publication will
remain unchanged until the stability date indicated on the IEC web site under
"http://webstore.iec.ch" in the data related to the specific publication. At this date, the
publication will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.

NOTE The attention of National Committees is drawn to the fact that equipment manufacturers and testing
organizations may need a transitional period following publication of a new, amended or revised IEC publication in
which to make products in accordance with the new requirements and to equip themselves for conducting new or
revised tests.
It is the recommendation of the committee that the content of this publication be adopted for implementation
nationally not earlier than 12 months or later than 36 months from the date of publication.

_____________
CONTENTS
Replace the title of Clause 3 but not the clause number, by the following:

Terms and definitions
Replace the title of Clause 28 but not the clause number, by the following:
Screws and connections

INTRODUCTION
Replace the fifth paragraph by the following:
When a part 2 standard does not include additional requirements to cover hazards dealt with
in Part 1, Part 1 applies.

---------------------- Page: 4 ----------------------
60335-2-76 Amend. 2 © IEC:2013 – 3 –


NOTE 1 This means that the technical committees responsible for the part 2 standards have determined that it is

not necessary to specify particular requirements for the appliance in question over and above the general
requirements.


This standard is a product family standard dealing with the safety of appliances and takes

precedence over horizontal and generic standards covering the same subject.


NOTE 2 Horizontal and generic standards covering a hazard are not applicable since they have been taken into

consideration when developing the general and particular requirements for the IEC 60335 series of standards. For
example, in the case of temperature requirements for surfaces on many appliances, generic standards, such as

ISO 13732-1 for hot surfaces, are not applicable in addition to Part 1 or part 2 standards.


2 Normative references

Add the following new references:
IEC 60335-2-29, Household and similar electrical appliances – Safety – Part 2-29: Particular
requirements for battery chargers
IEC 61204-7, Low-voltage power supplies, d.c. output – Part 7: Safety requirements
IEC 61558-2-16, Safety of transformers, reactors, power supply units and similar products for
voltages up to 1 100 V – Part 2-16: Particular requirements and tests for switch mode power
supply units and transformers for switch mode power supply units
ISO 3864-1, Graphical symbols – Safety colours and safety signs – Part 1: Design principles
for safety signs and safety markings
3 Definitions
Replace the title of Clause 3 but not the clause number, by the following:
Terms and definitions
3.1.6 Delete the addition to this subclause.
3.106 In the term definition, delete “separate”.
3.107 Replace the term definition by the following:
battery-operated energizer suitable for connection to the mains consisting of an impulse

generating circuit intended to be powered by a battery, or a separate supply unit, when the
energizer is in operation. The impulse generating circuit or the battery may be connected to a
separate battery charger for recharging the battery when the energizer is in operation.
Note 1 to entry: Examples of separate supply units are power supply units and uninterruptible power supplies.
5 General conditions for the tests
5.8.1 Replace the first two paragraphs of the addition by the following:
For energizers where the supply terminals for connection of a battery have no indication of
polarity, the more unfavourable polarity shall be applied.
Replace the third paragraph of the addition by the following:

---------------------- Page: 5 ----------------------
– 4 – 60335-2-76 Amend. 2 © IEC:2013


For energizer tests that require a connection to the mains supply, the reference source

impedance of the mains supply shall be 0,4 Ω + j0,25 Ω.



6 Classification


6.2 Add the following to the addition as a new sentence:


This requirement does not apply to separate supply units of type D energizers.


7 Marking and instructions

7.1 In the first paragraph replace “symbol 1641 of ISO 7000” by “symbol ISO 7000-0790
(2004-01)”.
Replace the third paragraph by the following:
Battery-operated energizers shall be marked with the symbol for “connection to mains-
operated equipment prohibited” or with the substance of the following warning:
WARNING: Do not connect to mains-operated equipment including battery chargers
The rules for a prohibition sign in ISO 3864-1, except for colours, apply to the symbol for
“connection to mains-operated equipment prohibited”.
A Type D Energizer shall be marked with symbol IEC 60417-6181 (2013-03) and the
references of the separate supply units that may be used to supply the impulse generating
circuit.
7.6 Delete the “dangerous voltage symbol” and its associated text.
Replace [symbol 5017 of IEC 60417] by [symbol IEC 60417-5017 (2006-08)].
Replace the last paragraph by the following:
The symbols for output (Fence) and output (Earth) shall be in accordance with symbols
IEC 60417-5036 (2002-10) and IEC 60417-5017 (2006-08) respectively.
Add the following:

[symbol IEC 60417-6181
separate supply unit
(2013-03)]

connection to mains-operated equipment

prohibited

7.12 Replace the text of the addition by the following:
Instructions for battery-operated energizers suitable for connection to the mains shall

---------------------- Page: 6 ----------------------
60335-2-76 Amend. 2 © IEC:2013 – 5 –


– include a warning against using non-rechargeable batteries while the energizer is powered

by the mains;

– state that during charging, vented rechargeable-batteries must be placed in a well-

ventilated area.


If the symbol for a separate supply unit or the symbol for “connection to mains-operated

equipment prohibited” is used, its meaning shall be explained.


Add the following:


7.14 Addition:

If symbol IEC 60417-6181 (2013-03) is marked on the appliance, its length shall be at least
12 mm.
If the symbol for “connection to mains-operated equipment prohibited” is marked on the
appliance, the outer diameter of the circle shall be at least 15 mm.
The height of characters used in the warning information that is marked on the appliance shall
not be less than that given by a 12 point font.
7.15 Addition:
If symbol IEC 60417-6181 (2013-03) is used, one shall be located adjacent to the appliance
inlet.
7.101 Replace the first paragraph of the requirement by the following:
Unless the correct mode of connection is obvious or irrelevant, the output terminals of the
energizer, other than dedicated output earth terminals, shall be clearly and indelibly identified
using symbol IEC 60417-5036 (2002-10). Dedicated output earth terminals, shall be clearly
and indelibly identified using symbol IEC 60417-5017 (2006-08).
Replace the last paragraph of the requirement by the following:
The height of characters in the marking shall not be less than that given by an 18 point font
and the symbols shall have a height of at least 6 mm.
7.102 Replace the text of the requirement by the following:

For battery-operated energizers and battery-operated energizers suitable for connection
to the mains, the supply terminals for connection of the battery shall be clearly indicated by
symbol IEC 60417-5005 (2002-10) for positive polarity, and by symbol IEC 60417-5006
(2002-10) for negative polarity, unless the polarity is irrelevant.
11 Heating
11.5 In the last paragraph, delete “, when they are connected for battery charger supply,”.
14 Transient overvoltages
14.101 Replace the first two dashed items by the following:
– 14.102 to 14.104 for mains-operated energizers and battery-operated energizers
suitable for connection to the mains;

---------------------- Page: 7 ----------------------
– 6 – 60335-2-76 Amend. 2 © IEC:2013


14.102 Add the following as a new second paragraph:


Type D energizers are further tested as follows.


Each specified separate supply unit is connected to the impulse generating circuit of the

energizer in turn. The impulse voltages are applied between the energizer output terminals

and the a.c. input terminals of the specified separate supply unit connected together and the

metal plate.


Each specified battery charger is connected as for charging the battery. The impulse

voltages are applied between the energizer output terminals and the a.c. input terminals of

the specified battery charger connected together and the metal plate. It is not necessary to
include a battery during this test.
14.103 Replace the second dashed item of the existing first paragraph by the following:
– the terminals for connection of the external battery charger or separate supply unit, for
type D energizers.
Add the following after the existing last paragraph:
Type D energizers are further tested as follows.
Each specified separate supply unit is connected to the impulse generating circuit of the
energizer in turn. The impulse voltages are applied between the energizer output terminals
connected together and the a.c. input terminals of the specified separate supply unit
connected together.
Each specified battery charger is connected as for charging the battery. The impulse
voltages are applied between the energizer output terminals connected together and the a.c.
input terminals of the specified battery charger connected together. It is not necessary to
include a battery during this test.
14.104 Add the following to the end of the paragraph:
For type D energizers, the input terminals of the impulse generating circuit are open-
circuited.
16 Leakage current and electric strength
16.1 In first dashed item, bold the words “suitable for connection to the mains”.
16.3 In Table 102, add “mains” before “supply circuit” in two places.
18 Endurance
Replace the third paragraph of the test specification by the following:
Type D energizers, are operated under conditions of normal operation. The voltage applied
is as specified in 11.5.
Add the following to the last sentence of the fourth paragraph of the test specification:
“or until the energizer ceases to function due to low battery voltage”

---------------------- Page: 8 ----------------------
60335-2-76 Amend. 2 © IEC:2013 – 7 –


Replace the fifth paragraph of the test specification by the following:


For type A energizers, a battery of the largest type for which the energizer is designed is

connected and placed in the battery compartment. Before starting the test, the battery is

discharged to such an extent that the voltage delivered does not exceed 0,75 times its

nominal value.


19 Abnormal operation


19.1 Delete the modification and add the following to the addition:

Energizers are also subjected to the tests of 19.101, 19.102, 19.103, 19.104 and 19.105.
19.13 Replace the second paragraph of the addition by the following:
If the impulse repetition rate is greater than 1,34 Hz, the discharge energy per second into a
load consisting of a non-inductive resistor of 500 Ω shall not exceed 2,5 J/s after 3 min.
22 Construction
Add the following:
22.46 Addition:
If programmable protective electronic circuits alone are used to ensure compliance with the
output characteristics specified in 19.13, the software shall contain measures to control the
fault/error conditions specified in Table R.2.
22.112 The clearance between parts of opposite polarity for connecting the battery in
battery operated energizers and in battery operated energizers suitable for connections
to the mains shall not be less than 2 mm, when the energizer is fitted with conductors as in
normal use.
Compliance is checked by measurement.
24 Components
Replace the text by the following:

This clause of Part 1 is applicable except as follows.
24.1.101 The relevant standard for separate power supply units is IEC 61558-2-6.
Separate power supply units of the switch mode type shall be safety isolating switch mode
power supplies complying with IEC 61558-2-16.
The relevant standard for battery chargers is IEC 60335-2-29.
The relevant standard for uninterruptible power supply units is IEC 61204-7.
25 Supply connection and external flexible cords
25.8 Replace the text of the addition by the following:

---------------------- Page: 9 ----------------------
– 8 – 60335-2-76 Amend. 2 © IEC:2013


The conductors in flexible leads or flexible cords used to connect the battery in battery

operated energizers and type D energizers shall have a nominal cross-sectional area of not

2
less than 0,75 mm .


28 Screw and connection


Replace the title of Clause 28 but not the clause number, by the following:


Screws and connections


29 Clearances, creepage distances and solid insulation
Delete the Addition and 2
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.