IEC 60793-1-42:2007/COR1:2007
(Corrigendum)Corrigendum 1 - Optical fibres - Part 1-42: Measurement methods and test procedures - Chromatic dispersion
Corrigendum 1 - Optical fibres - Part 1-42: Measurement methods and test procedures - Chromatic dispersion
General Information
Relations
Standards Content (Sample)
IEC 60793-1-42
(Second edition - 2007)
OPTICAL FIBRES –
Part 1-42: Measurement methods and test procedures –
Chromatic dispersion
CORRIGENDUM 1
Page 6
1 Scope
In the antepenultimate paragraph, instead of:
IEC 60793-1,
read:
IEC 60793-1-1.
Page 7
2 Normative references
Delete IEC 60793-2 from the list of references.
Page 9
6.3 Reference fibre
In the note, change “shall “ to “should”.
Page 15
A.1.3 Modulator
In the first paragraph, instead of:
one part in 106
read:
one part in 10 .
In Note 1, instead of:
Equation (A.2) abo
...
This May Also Interest You
IEC 60793-1-46:2024 establishes uniform requirements for the monitoring of changes in attenuation, thereby assisting in the inspection of fibres and cables for commercial purposes. This document gives two methods for monitoring the changes in attenuation of optical fibres and cables that occur during mechanical or environmental testing, or both. It provides a monitor in the change of attenuation characteristics arising from optical discontinuity, physical defects and modifications of the attenuation slope:
- method A: change in attenuation by transmitted power;
- method B: change in attenuation by backscattering.
Methods A and B apply to the monitoring of all categories of the following fibres:
- class A: multimode fibres;
- class B: single-mode fibres;
- class C: single-mode intraconnection fibres.
Information common to both measurements is contained in Clause 1 to Clause 10, and information pertaining to each individual method appears in Annex A, and Annex B respectively.
- Standard39 pagesEnglish languagesale 15% off
- Standard24 pagesEnglish and French languagesale 15% off
IEC 60793-1-22:2024 establishes uniform requirements for measuring the length and elongation of optical fibre (typically within cable). The length of an optical fibre is a fundamental value for the evaluation of transmission characteristics such as losses and bandwidths.
- Standard123 pagesEnglish languagesale 15% off
- Standard81 pagesEnglish and French languagesale 15% off
IEC 60794-1-201: 2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of:
- optical fibre cables for use with telecommunication equipment and devices employing similar techniques; and
- cables having a combination of both optical fibres and electrical conductors.
Throughout this document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document defines a test standard to determine the ability of a cable to withstand the effects of temperature cycling by observing changes in attenuation. See IEC 60794-1-2 for a reference guide to test methods of all types and for general requirements and definitions.
This document partially replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017:
a) all references to the temperature sensing device have been removed and replaced with a note "for further study";
b) the conditioning procedure has been separated into Procedure 1 and Procedure 2 to avoid confusion;
c) the ambient temperature test condition has been defined as per IEC 60794-1-2;
d) the minimum soak time has been decreased for sample mass >16 kg in Table 1.
- Standard25 pagesEnglish and French languagesale 15% off
IEC 60794-1-209:2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of:
- optical fibre cables for use with telecommunication equipment and devices employing similar techniques; and
- cables having a combination of both optical fibres and electrical conductors.
Throughout this document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document defines a test standard to determine cable aging performance by high temperature exposure and temperature cycling in order to simulate lifetime behaviour of the attenuation of cables, or physical attributes. See IEC 60794‑1‑2 for a reference guide to test methods of all types and for general requirements and definitions.
This document partially cancels and replaces IEC 60794‑1‑22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794‑1‑22:2017:
a) the ambient temperature test condition has been defined as per IEC 60794‑1‑2;
b) all the maximum allowable attenuation increase values for single-mode and multimode fibres have been deleted, and have been included in the list of details to be specified.
- Standard17 pagesEnglish and French languagesale 15% off
IEC 60794-1-101:2024 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors.
This document defines test procedures to be used in establishing uniform requirements for tensile performance.
Throughout this document the wording "optical cable" includes optical fibre units, microduct fibre units, etc.
See IEC 60794-1-2 for general requirements and definitions and for a complete reference guide to test methods of all types.
- Standard18 pagesEnglish and French languagesale 15% off
IEC 60794-1-213:2024 defines test procedures to be used in establishing uniform requirements for the environmental performance of microduct. The test determines the capability of the microduct to withstand internal pressure without leakage and visible damage. This document applies to microduct used for installation of microduct cable or fibre unit by blowing. Throughout this document, the wording "microduct" can also include protected microduct(s). See IEC 60794-1-2 for a reference guide to test methods of all types and for general requirements and definitions.This document partially cancels and replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017:
a) pressure gauge used to monitor internal pressure of microduct added as part of the test apparatus;
b) "test temperature" added to the details to be specified;
c) added a new subclause “4.7 Details to be reported”.
- Standard16 pagesEnglish and French languagesale 15% off
IEC 60794-1-104:2024 applies to optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and to cables having a combination of both optical fibres and electrical conductors. This document defines test procedures to be used in establishing uniform requirements for impact performance. Throughout this document the wording “optical cable” includes optical fibre units, microduct fibre units, etc. See IEC 60794-1-2 for general requirements and definitions and for a complete reference guide to test methods of all types.
This document partially cancels and replaces IEC 60794-1-21:2015, which will be withdrawn. In the context of the revision of IEC 60794-1-21:2015, its contents were split into separate test methods. It includes an editorial revision, based on the new structure and numbering system for optical fibre cable test methods.
- Standard20 pagesEnglish and French languagesale 15% off
IEC 60793-1-45:2024 is available as IEC 60793-1-45:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-45:2024 establishes uniform requirements for measuring the mode field diameter (MFD) of single-mode optical fibre, thereby assisting in the inspection of fibres and cables for commercial purposes. This third edition cancels and replaces the second edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) modification of the minimum distance between the fibre end and the detector for the direct far field scan (Annex A).
b) generalization of the requirement for the minimum dynamic range for all fibre types (Annex A).
- Standard93 pagesEnglish languagesale 15% off
- Standard62 pagesEnglish and French languagesale 15% off
IEC 60793-1-41:2024 is available as IEC 60793-1-41:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793‑2‑40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are:
Method A – Time domain (pulse distortion) measurement
Method B – Frequency-domain measurement
Method C – Overfilled launch modal bandwidth calculated from differential mode delay (OMBc)
Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre.
NOTE 1 These test methods are commonly used in production and research facilities and are not easily accomplished in the field.
NOTE 2 OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a direct reference for method A and method B.
- Standard92 pagesEnglish languagesale 15% off
- Standard62 pagesEnglish and French languagesale 15% off
IEC 60794-1-212:2024 defines the test procedure to examine the attenuation behaviour (change in attenuation) when an optical fibre cable with cable elements fixed at both ends is subjected to temperature cycling. This test assesses the attenuation behaviour of a cable under a no-end movement condition intended for termination with, for example, interconnecting devices or passive components. This document partially cancels and replaces IEC 60794-1-22:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-22:2017:
a) the description of the test method has been changed to “with cable elements fixed at both ends”;
b) subclauses have been added to the procedure clause;
c) the preparation of cable sample and test set-up has been arranged in a logical way;
d) Figure 1 has been added for illustration of the preparation of cable sample, DUT and test set-up;
e) the temperature chamber temperature tolerance has been changed to ± 3 °C as done in IEC 60794‑1‑22, method F1;
f) all required steps have been added to the subclause for temperature cycling as well as the table for the minimum soak time and the figure for the cycle procedure, and removed the reference to IEC 60794-1-22, method F1;
g) the maximum change in attenuation has been added to the details to be specified;
h) a new subclause 4.5 has been added for details to be reported.