Magnesium and magnesium alloys — Determination of arsenic — Inductively coupled plasma optical emission spectrometric method

Titre manque

General Information

Status
Not Published
Current Stage
Ref Project

Buy Standard

Draft
ISO/DTS 4188 - Magnesium and magnesium alloys — Determination of arsenic — Inductively coupled plasma optical emission spectrometric method Released:11. 07. 2023
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Draft
REDLINE ISO/DTS 4188 - Magnesium and magnesium alloys — Determination of arsenic — Inductively coupled plasma optical emission spectrometric method Released:11. 07. 2023
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


FINAL
TECHNICAL ISO/DTS
DRAFT
SPECIFICATION 4188
ISO/TC 79/SC 5
Magnesium and magnesium
Secretariat: SAC
alloys — Determination of arsenic —
Voting begins on:
2023-07-25 Inductively coupled plasma optical
emission spectrometric method
Voting terminates on:
2023-09-19
RECIPIENTS OF THIS DRAFT ARE INVITED TO
SUBMIT, WITH THEIR COMMENTS, NOTIFICATION
OF ANY RELEVANT PATENT RIGHTS OF WHICH
THEY ARE AWARE AND TO PROVIDE SUPPOR TING
DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
Reference number
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO-
LOGICAL, COMMERCIAL AND USER PURPOSES,
DRAFT INTERNATIONAL STANDARDS MAY ON
OCCASION HAVE TO BE CONSIDERED IN THE
LIGHT OF THEIR POTENTIAL TO BECOME STAN-
DARDS TO WHICH REFERENCE MAY BE MADE IN
NATIONAL REGULATIONS. © ISO 2023

FINAL
TECHNICAL ISO/DTS
DRAFT
SPECIFICATION 4188
ISO/TC 79/SC 5
Magnesium and magnesium
Secretariat: SAC
alloys — Determination of arsenic —
Voting begins on:
Inductively coupled plasma optical
emission spectrometric method
Voting terminates on:
© ISO 2023
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
RECIPIENTS OF THIS DRAFT ARE INVITED TO
ISO copyright office
SUBMIT, WITH THEIR COMMENTS, NOTIFICATION
OF ANY RELEVANT PATENT RIGHTS OF WHICH
CP 401 • Ch. de Blandonnet 8
THEY ARE AWARE AND TO PROVIDE SUPPOR TING
CH-1214 Vernier, Geneva
DOCUMENTATION.
Phone: +41 22 749 01 11
IN ADDITION TO THEIR EVALUATION AS
Reference number
Email: copyright@iso.org
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO­
Website: www.iso.org
LOGICAL, COMMERCIAL AND USER PURPOSES,
DRAFT INTERNATIONAL STANDARDS MAY ON
Published in Switzerland
OCCASION HAVE TO BE CONSIDERED IN THE
LIGHT OF THEIR POTENTIAL TO BECOME STAN­
DARDS TO WHICH REFERENCE MAY BE MADE IN
ii
NATIONAL REGULATIONS. © ISO 2023

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Reagents . 1
6 Apparatus . 2
6.1 Inductively coupled plasma optical emission spectrometer . 2
6.1.1 General . 2
6.1.2 Wavelength . 2
6.1.3 Limit of detection . 3
6.1.4 Linearity of the calibration curve . 3
7 Sampling and sample preparation . 3
8 Procedure .3
8.1 General . 3
8.2 Test sample . 3
8.3 Preparation of the test solution . 3
8.4 Preparation of the calibration solutions . 3
8.5 Adjustment of the apparatus . 4
8.6 Measurement of the calibration solutions . 4
8.7 Calibration curve . 4
8.8 Measurement of the test solution . 4
9 Expression of results . 4
9.1 Method of calculation . 4
9.2 Precision . . . 5
10 Test report . 5
Annex A (normative) Limit of detection .6
Annex B (informative) Information on the precision test . 7
Annex C (informative) Graphical representation of precision data . 8
Bibliography . 9
iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non­governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO document should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use
of (a) patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed
patent rights in respect thereof. As of the date of publication of this document, ISO had not received
notice of (a) patent(s) which may be required to implement this document. However, implementers are
cautioned that this may not represent the latest information, which may be obtained from the patent
database available at www.iso.org/patents. ISO shall not be held responsible for identifying any or all
such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO's adherence to
the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see
www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 79, Light metals and their alloys,
Subcommittee SC 5, Magnesium and alloys of cast or wrought magnesium.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
Introduction
Magnesium and magnesium alloys are one kind of light metallic materials and show several
advantageous properties, such as low density, high specific stiffness and strength, good damping
capacity, castability, weldability and machinability, etc. Arsenic as one of the hazardous impurities has
negative effects on the environment and health, and needs to be strictly controlled. The sum of the
mass contents of cadmium (Cd), mercury (Hg), arsenic (As) and chromium (Cr) given in ISO 8287 is
defined to be less than 0,01 % in magnesium and its alloys, which needs to be inspected if used in food
and medicine fields.
v
TECHNICAL SPECIFICATION ISO/DTS 4188:2023(E)
Magnesium and magnesium alloys — Determination of
arsenic — Inductively coupled plasma optical emission
spectrometric method
1 Scope
This document specifies an inductively coupled plasma optical emission spectrometric method (ICP-
OES) for the determination of arsenic contents between 0,001 0 % (mass fraction) and 0,050 % (mass
fraction) in magnesium and magnesium alloys.
The method is limited to magnesium alloys containing less than 0,6 % (mass fraction) of cerium,
0,1 % (mass fraction) of gadolinium, 0,2 % (mass fraction) of neodymium and 0,8 % (mass fraction) of
zirconium.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
ISO 648, Laboratory glassware — Single-volume pipettes
ISO 1042, Laboratory glassware — One-mark volumetric flasks
ISO 3696, Water for analytical laboratory use — Specification and test methods
3 Terms and definitions
No terms and definitions are listed in this document.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at http:// www .electropedia .org/
4 Principle
After dissolution of a test sample with nitric acid and hydrochloric acid, the solution is nebulized into
an inductively coupled plasma optical emission spectrometer and the intensity of the arsenic emitted
light is measured. The concentrations of arsenic in the test solutions are derived from a magnesium­
based calibration curve.
5 Reagents
During the analysis, use only reagents of recognized analytical grade and only grade 2 water as
specified in ISO 3696, or water of equivalent purity.
5.1 Pure magnesium, purity > 99,99 % (mass fraction), free from arsenic.
5.2 Pure arsenic, purity > 99,99 % (mass fraction).
5.3 Hydrochloric acid, ρ about 1,19 g/ml.
5.4 Nitric acid, ρ about 1,14 g/ml.
5.5 Hydrochloric acid solution 1 + 1
Add 500 ml of hydrochloric acid (5.3) to 500 ml of water and mix.
5.6 Nitric acid solution 1 + 1
Add 500 ml of nitric acid (5.4) to 500 ml of water and mix.
5.7 Arsenic standard solution, 1 g/l.
Weigh to the nearest 0,001 g, 0,5 g of pure arsenic (5.2) and transfer into a 250 ml beaker. Add 20 ml
of nitric acid solution (5.6) and cover with a watch glass. Heat gently until the metal is dissolved. After
cooling to room temperature, transfer the solution quantitatively into a 500 ml one-mark volumetric
flask, dilute to the mark with water and mix.
1 ml
...


1.1.1 ISO TC 79/SC 5
1.1.2 Date: 2023-05
ISO/TC 79/SC 5
Secretariat: SAC
Date: 2023-07-11
Magnesium and magnesium alloys – — Determination of arsenic –— Inductively
coupled plasma optical emission spectrometric method

Magnésium et alliages de magnésium - Détermination de l'arsenic - Méthode par
spectrométrie d'émission atomique avec source à plasma induit

FDIS stage
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this
publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including
photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested
from either ISO at the address below or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: + 41 22 749 01 11
E-mail: copyright@iso.org
Website: www.iso.org
Published in Switzerland
©ISO 2018 - All rights reserved

Contents
Foreword . vii
Introduction . ix
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Reagents . 2
6 Apparatus . 2
6.1 Inductively coupled plasma optical emission spectrometer . 3
6.1.1 General . 3
6.1.2 Wavelength . 3
6.1.3 Limit of detection . 3
6.1.4 Linearity of the calibration curve . 3
7 Sampling and sample preparation . 3
8 Procedure. 3
8.1 General . 3
8.2 Test sample . 3
8.3 Preparation of the test solution . 4
8.4 Preparation of the calibration solutions . 4
8.5 Adjustment of the apparatus . 4
8.6 Measurement of the calibration solutions . 4
8.7 Calibration curve . 5
8.8 Measurement of the test solution . 5
9 Expression of results . 5
9.1 Method of calculation . 5
9.2 Precision . 5
10 Test report . 6
Annex A (normative) Limit of detection . 7
Annex B (informative) Information on the precision test . 1
Annex C (informative) Graphical representation of precision data . 3
Bibliography . 6

Foreword . iv

Introduction . v
1 Scope. 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 1
5 Reagent . 1
6 Apparatus . 2
6.1 Inductively coupled plasma optical emission spectrometer . 2
6.1.1 General . 2
6.1.2 Wavelength . 3
6.1.3 Limit of detection . 3
6.1.4 Linearity of the calibration curve . 3
7 Sampling and sample preparation . 3
8 Procedure . 3
8.1 General . 3
8.2 Test sample . 错误!未定义书签。
8.3 Preparation of the test solution . 3
8.4 Preparation of the calibration solutions . 4
8.5 Adjustment of the apparatus . 4
8.6 Measurement of the calibration solutions . 4
8.7 Calibration curve . 4
8.8 Measurement of the test solution . 5
9 Expression of results . 5
9.1 Method of calculation . 5
9.2 Precision . 5
10 Test report . 5
Annex A (normative) Limit of detection . 7
Annex B (normative) Information on the precision test . 8
Annex C (informative) Graphical representation of precision data . 9
Bibliography. 10

©ISO 2018 - All rights reserved

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO
collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.

The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the
different types of ISO documentsdocument should be noted. This document was drafted in accordance with
the editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Field Code Changed
Attention is drawnISO draws attention to the possibility that some of the elementsimplementation of this
document may beinvolve the subjectuse of (a) patent(s). ISO takes no position concerning the evidence,
validity or applicability of any claimed patent rights. in respect thereof. As of the date of publication of this
document, ISO had not received notice of (a) patent(s) which may be required to implement this document.
However, implementers are cautioned that this may not represent the latest information, which may be
obtained from the patent database available at www.iso.org/patents. ISO shall not be held responsible for
identifying any or all such patent rights. Details of any patent rights identified during the development of
the document will be in the Introduction and/or on the ISO list of patent declarations received (see
www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conform
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.