Resilient and laminate floor coverings — Determination of indentation and residual indentation — Part 2: Short-term residual indentation of resilient floor covering

ISO 24343-2:2011 describes a method for determining the short-term indentation and residual indentation produced in a resilient floor covering after the application and removal of a constant load.

Revêtements de sol résilients et stratifiés — Détermination du poinçonnement et du poinçonnement rémanent — Partie 2: Poinçonnement rémanent de courte durée des revêtements de sol résilients

General Information

Status
Withdrawn
Publication Date
04-Aug-2011
Withdrawal Date
04-Aug-2011
Technical Committee
Drafting Committee
Current Stage
9599 - Withdrawal of International Standard
Completion Date
19-Oct-2018
Ref Project

Relations

Buy Standard

Standard
ISO 24343-2:2011 - Resilient and laminate floor coverings -- Determination of indentation and residual indentation
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL  ISO
STANDARD 24343-2
First edition
2011-08-15
Resilient and laminate floor coverings —
Determination of indentation and residual
indentation —
Part 2:
Short-term residual indentation of
resilient floor covering
Revêtements de sol résilients et stratifiés — Détermination du
poinçonnement et du poinçonnement rémanent —
Partie 2: Poinçonnement rémanent de courte durée des revêtements de
sol résilients
Reference number
ISO 24343-2:2011(E)
©
 ISO 2011

---------------------- Page: 1 ----------------------
ISO 24343-2:2011(E)
COPYRIGHT PROTECTED DOCUMENT
©  ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 24343-2:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 24343-2 was prepared by Technical Committee ISO/TC 219, Floor coverings.
ISO 24343 consists of the following parts, under the general title Resilient and laminate floor coverings —
Determination of indentation and residual indentation:
—  Part 1: Residual indentation
—  Part 2: Short-term residual indentation of resilient floor covering
—  Part 3: Indentation of resilient semi-flexible/vinyl composition tiles
© ISO 2011 – All rights reserved  iii

---------------------- Page: 3 ----------------------
INTERNATIONAL STANDARD ISO 24343-2:2011(E)
Resilient and laminate floor coverings — Determination of
indentation and residual indentation —
Part 2:
Short-term residual indentation of resilient floor covering
1 Scope
This part of ISO 24343 describes a method for determining the short-term indentation and residual indentation
produced in a resilient floor covering after the application and removal of a constant load.
2 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
2.1
indentation
difference between the initial thickness and the thickness measured after removal of the load
2.2
residual indentation
difference between the initial thickness and the thickness measured after removal of the load and a specified
recovery period
2.3
thickness
distance between two parallel plates where the floor covering is inserted under a specific load
3 Principle
A test piece is subjected to a static loading, the thickness being measured before loading, after removal of the
load and after a specified recovery period.
4 Appa
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.