Gas cylinders — Residual pressure valves — Specification and type testing of cylinder valves incorporating residual pressure devices

ISO 15996:2017 specifies design, type testing and marking requirements for cylinder valves incorporating residual pressure devices, hereinafter referred to as residual pressure valves (RPVs). This document applies to the following types of RPVs: a) cylinder valves intended to be fitted to refillable transportable gas cylinders; b) main valves (excluding ball valves) for cylinder bundles; c) cylinder valves or main valves with integrated pressure regulator (VIPR); d) valves for pressure drums and tubes; which convey compressed or liquefied gases. NOTE Where there is no risk of ambiguity, cylinders, pressure drums, tubes and cylinder bundles are addressed with the collective term "cylinder" within this document. These requirements are in addition to those in ISO 10297. For RPD stand-alone devices this document can also be applied. ISO 15996:2017 does not apply to RPVs for portable fire extinguishers, cryogenic equipment, low pressure refrigerant gases (cylinder test pressure less than 50 bar), dissolved gases or liquefied petroleum gas (LPG).

Bouteilles à gaz — Robinets à pression résiduelle — Spécifications et essais de type de robinets de bouteille intégrant des dispositifs de pression résiduelle

ISO 15996:2017 spécifie les exigences applicables à la conception, aux essais de type et au marquage des robinets de bouteille comportant des dispositifs de pression résiduelle, désignés dans le présent document par le terme «robinets à pression résiduelle» (RPV). Le présent document s'applique aux types de RPV suivants: a) les robinets de bouteille destinés à être montés sur des bouteilles à gaz transportables rechargeables; b) les vannes principales (à l'exception des robinets à boisseau sphérique) pour cadres de bouteilles; c) les robinets de bouteille ou robinets de bouteille à détendeur intégré (VIPR); d) les robinets pour les fûts à pression et les tubes; utilisés pour transporter des gaz comprimés ou liquéfiés. NOTE Lorsqu'il n'existe aucun risque d'ambiguïté, les bouteilles, fûts à pression, tubes et cadres de bouteilles sont désignés par le terme générique «bouteille» dans le présent document. Ces exigences s'ajoutent à celles de l'ISO 10297. ISO 15996:2017 peut également être appliqué aux dispositifs RPD autonomes. Le présent document ne s'applique pas aux RPV destinés aux extincteurs d'incendie portables, aux équipements cryogéniques, aux gaz réfrigérants à basse pression (pression d'épreuve de la bouteille inférieure à 50 bar), aux gaz dissous ou aux gaz de pétrole liquéfié (GPL).

General Information

Status
Published
Publication Date
07-Aug-2017
Current Stage
9093 - International Standard confirmed
Completion Date
06-Dec-2022
Ref Project

Relations

Buy Standard

Standard
ISO 15996:2017 - Gas cylinders -- Residual pressure valves -- Specification and type testing of cylinder valves incorporating residual pressure devices
English language
21 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 15996:2017 - Bouteilles a gaz -- Robinets a pression résiduelle -- Spécifications et essais de type de robinets de bouteille intégrant des dispositifs de pression résiduelle
French language
21 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

INTERNATIONAL ISO
STANDARD 15996
Second edition
2017-07
Gas cylinders — Residual pressure
valves — Specification and type testing
of cylinder valves incorporating
residual pressure devices
Bouteilles à gaz — Robinets à pression résiduelle — Spécifications
et essais de type de robinets de bouteille intégrant des dispositifs de
pression résiduelle
Reference number
ISO 15996:2017(E)
©
ISO 2017

---------------------- Page: 1 ----------------------
ISO 15996:2017(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2017, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 15996:2017(E)

Contents Page
Foreword .iv
Introduction .vi
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 RPV design considerations and requirements . 3
4.1 Design considerations. 3
4.1.1 Resistance against vibration . 3
4.1.2 Integrity under high flow . 4
4.2 Design requirements . 4
4.2.1 General. 4
4.2.2 Valve outlet connection . 4
4.3 Performance requirements for RPDs. 4
4.3.1 Requirements for type 1 and type 2 RPDs . 4
4.3.2 Additional requirements for type 1 RPDs . 5
5 RPV type testing . 5
5.1 General . 5
5.2 Documentation . 6
5.3 Test samples . 6
5.4 Test report . 7
5.5 Test temperatures . 7
5.6 Test pressures . 7
5.6.1 RPV test pressure . 7
5.6.2 Other test pressures . 7
5.7 Test gases . 7
5.7.1 Gas quality . 7
5.7.2 Verification of opening pressure and closing-off pressure. 8
5.7.3 Leak tightness test in the reverse direction for type 1 RPDs . 8
5.7.4 Endurance test . 8
5.7.5 Oxygen pressure surge test. 8
5.7.6 Vibration test . 8
5.7.7 Integrity under high flow test . 9
5.8 Test schedule . 9
5.9 RPD performance tests .10
5.9.1 Strength test of the non-return function in the reverse direction for
type 1 RPDs .10
5.9.2 Verification of opening pressure and closing-off pressure.10
5.9.3 Endurance test .11
5.9.4 Leak tightness test in the reverse direction for type 1 RPDs .11
5.9.5 Visual examination .12
6 Marking .12
Annex A (informative) Design considerations .13
Annex B (normative) Oxygen pressure surge test .14
Annex C (informative) Vibration test .15
Annex D (informative) Integrity under high flow test .16
Annex E (informative) Examples of test equipment .18
Bibliography .21
© ISO 2017 – All rights reserved iii

---------------------- Page: 3 ----------------------
ISO 15996:2017(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www .iso .org/ directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www .iso .org/ patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the voluntary nature of standards, the meaning of ISO specific terms and
expressions related to conformity assessment, as well as information about ISO’s adherence to the
World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT) see the following
URL: w w w . i s o .org/ iso/ foreword .html.
This document was prepared by Technical Committee ISO/TC 58, Gas cylinders, Subcommittee SC 2,
Cylinder fittings.
This second edition cancels and replaces the first edition (ISO 15996:2005), which has been technically
revised. It also incorporates the Amendment ISO 15996:2005/Amd 1:2007.
The main changes compared to the previous edition are as follows:
a) Title and scope: extension to cover the complete RPV (valve including the residual pressure device)
and not the RPD (residual pressure device) only; informative reference to ISO 10297 was modified;
b) Scope: inclusion of main valves, valves with integrated pressure regulator (VIPRs) and RPVs for
pressure drums and tubes; exclusion of dissolved gases, possible application for RPD stand-alone
devices;
c) Terms, definitions and symbols: introduction of new definitions and adaptation of existing
definitions; introduction of different types of RPDs to replace the old descriptions and change of
order (type A became type 2 and type B became type 1);
d) Valve design considerations: inclusion of design considerations with addition of informative
Annex A;
e) Performance requirements and considerations:
1) Closing-off pressure and opening pressure: introduction of requirements for opening pressure
and closing-off pressure, especially of a minimum value for the closing-off pressure;
2) Endurance: reduction of number of endurance cycles for type 2 RPDs;
3) Visual examination: introduction of visual examination at the end of the complete test
procedure;
iv © ISO 2017 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 15996:2017(E)

4) Resistance of the non-return function against pressure in the reverse direction for type 1
RPDs: exclusion of RPDs in VIPRs and adaptation of pass-fail requirements;
5) Leak tightness in the reverse direction for type 1 RPDs: exclusion of RPDs in VIPRs;
6) Integrity under high flow: exclusion of RPDs when installed outside the filling path in a VIPR;
f) RPV type testing:
1) General: introduction of information on how to deal with changes within the RPV design;
2) Test samples: addition of requirement to submit the test samples for oxygen pressure surge
testing with the relevant filling connector(s);
3) Test gases: introduction of requirements on the use and quality of the test gases;
4) Test schedule: adaptation to meet the new requirements, addition of test pressure and test
temperature; deletion of information on variants;
5) Strength test of the non-return function in the reverse direction for type 1 RPD tests: decrease
of number of test samples to one;
6) Verification of opening pressure and closing-off pressure: addition of verification at low and
high temperature; addition of detailed test procedure;
7) Leak tightness test in the reverse direction for type 1 RPDs: modification and clarification of
tightness test in the flow direction; addition of test at 0,5 bar in the reverse direction;
8) Visual examination: addition of visual examination to the test sequence;
9) Oxygen pressure surge test: information transferred to normative Annex B; addition of test for
main valves; addition of detailed information on test procedure;
g) Marking: introduction of marking requirements;
h) Annex A (informative): deletion of examples of RPV designs; introduction of design considerations;
i) Annex B (normative): information on test equipment transferred to informative Annex D; new
Annex B giving mandatory requirements on oxygen pressure surge test;
j) Annex C (informative): update of MIL standard reference for vibration test;
k) Annex D (informative): complete modification of integrity under high flow test (reduction of
number of test samples, adaptation of gases for which an additional test with carbon dioxide
should be carried out, change from liquid carbon dioxide to gaseous carbon dioxide as test gas,
modification of test procedure);
l) Annex E: new informative Annex E giving information on test equipment (former Annex B).
© ISO 2017 – All rights reserved v

---------------------- Page: 5 ----------------------
ISO 15996:2017(E)

Introduction
Increased requirements to avoid contamination of gases and cylinders have led to the development
of valves incorporating residual pressure devices (RPDs) hereinafter referred to as residual pressure
valves (RPVs).
These devices are designed to maintain a positive pressure relative to atmosphere within the cylinder
by closing off its internal gas passages in the discharging direction. This prevents the cylinder from
being completely emptied in customer use and stops ingress of atmospheric contamination if the valve
operating mechanism (main shut-off) is left open. Many of these devices include a non-return function
that protects the cylinder from backflow from downstream processes.
This document has been written so that it is suitable for the application of the UN Model Regulations.
Considering the changes described in the Foreword, when an RPV has been approved according to the
previous version of this document, the body responsible for approving the same RPV to this new edition
should consider which tests need to be performed.
In this document the unit bar is used, due to its universal use in the field of technical gases. It should,
however, be noted that bar is not an SI unit, and that the corresponding SI unit for pressure is Pa
5 5 2
(1 bar = 10 Pa = 10 N/m ).
Pressure values given in this document are given as gauge pressure (pressure exceeding atmospheric
pressure) unless noted otherwise.
vi © ISO 2017 – All rights reserved

---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 15996:2017(E)
Gas cylinders — Residual pressure valves — Specification
and type testing of cylinder valves incorporating residual
pressure devices
1 Scope
This document specifies design, type testing and marking requirements for cylinder valves
incorporating residual pressure devices, hereinafter referred to as residual pressure valves (RPVs).
This document applies to the following types of RPVs:
a) cylinder valves intended to be fitted to refillable transportable gas cylinders;
b) main valves (excluding ball valves) for cylinder bundles;
c) cylinder valves or main valves with integrated pressure regulator (VIPR);
d) valves for pressure drums and tubes;
which convey compressed or liquefied gases.
NOTE Where there is no risk of ambiguity, cylinders, pressure drums, tubes and cylinder bundles are
addressed with the collective term “cylinder” within this document.
These requirements are in addition to those in ISO 10297.
For RPD stand-alone devices this document can also be applied.
This document does not apply to RPVs for portable fire extinguishers, cryogenic equipment, low
pressure refrigerant gases (cylinder test pressure less than 50 bar), dissolved gases or liquefied
petroleum gas (LPG).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies
ISO 10286, Gas cylinders — Terminology
ISO 10297:2014, Gas cylinders — Cylinder valves — Specification and type testing
ISO 10524-3, Pressure regulators for use with medical gases — Part 3: Pressure regulators integrated with
cylinder valves
ISO 22435, Gas cylinders — Cylinder valves with integrated pressure regulators — Specification and
type testing
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 10286, ISO 10297 and the
following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at http:// www .iso .org/ obp
© ISO 2017 – All rights reserved 1

---------------------- Page: 7 ----------------------
ISO 15996:2017(E)

— IEC Electropedia: available at http:// www .electropedia .org/
3.1
residual pressure valve
RPV
valve which incorporates a residual pressure device (3.2)
Note 1 to entry: The term “valve” covers the valves listed in Clause 1, a) to d).
3.2
residual pressure device
RPD
device that is designed to prevent ingress of contaminants by maintaining a positive pressure within
the cylinder relative to atmosphere by closing off its internal gas passages in the discharging direction
Note 1 to entry: This definition might be different to definitions given in applicable transport regulations.
3.3
type 1 RPD
RPD (3.2) that retains a positive pressure in the cylinder above the pressure downstream of the valve
outlet and also incorporates a non-return feature to prevent backflow into the cylinder from a higher
pressure on the valve outlet
Note 1 to entry: Cylinders with RPVs with a type 1 RPD located between the filling port and cylinder cannot be
filled or vacuumed unless the RPD is neutralized or a special fill connector is used to overcome the non-return
feature.
3.4
type 2 RPD
RPD (3.2) that retains a positive pressure in the cylinder above atmospheric pressure but will not
prevent backflow into the cylinder if the pressure on the valve outlet is high enough to overcome the
RPD mechanism and the residual pressure in the cylinder
Note 1 to entry: Cylinders with RPVs with a type 2 RPD can be filled with a conventional fill connector, but,
if located between the filling port and cylinder, cannot be vacuumed or vented below the closing-off pressure
unless the RPD is neutralized or a special fill connector is used.
3.5
discharging direction
path taken by gas through the RPD (3.2) when flowing out of the cylinder through the outlet connection
3.6
reverse direction
path taken by gas towards the RPD (3.2) in the opposite direction to the discharging direction (3.5)
3.7
filling direction
path taken by gas through the RPV (3.1) when filling the cylinder
Note 1 to entry: Depending on the design of the RPV (3.1), filling direction and reverse direction (3.6) might be
the same.
3.8
opening pressure
differential pressure between upstream pressure and downstream pressure of the RPD (3.2) at which
the RPD starts to open to allow gas to flow in the discharging direction (3.5)
Note 1 to entry: Due to the effects of manufacturing tolerances this is normally expressed as a pressure range.
2 © ISO 2017 – All rights reserved

---------------------- Page: 8 ----------------------
ISO 15996:2017(E)

3.9
closing-off pressure
cylinder pressure at which leak tight closure of the RPD (3.2) is achieved during gas withdrawal through
the outlet connection
Note 1 to entry: Due to the effects of manufacturing tolerances and different discharge rates this is expressed as
a pressure range.
3.10
RPV working pressure
p
w
settled pressure of a compressed gas at a uniform reference temperature of 15 °C in a full cylinder for
which the RPV (3.1) is intended
Note 1 to entry: This definition does not apply to liquefied gases (e.g. carbon dioxide), or dissolved gases (e.g.
acetylene).
Note 2 to entry: The RPV working pressure is expressed in bar.
3.11
RPV test pressure
p
vt
pressure applied to a RPV (3.1) during testing
Note 1 to entry: The RPV test pressure is a minimum value and is expressed in bar.
3.12
NTP
normal temperature and pressure i.e. 20,0 °C (293,15 K), 1,013 bar absolute (0,101 3 MPa absolute)
3.13
RPV filling connector
device fitted to the filling connection of RPVs (3.1) fitted with type 1 RPDs (3.3) during filling to overcome
the non-return feature and for both type 1 and type 2 RPDs (3.4) during venting and vacuuming
Note 1 to entry: These connectors are design-specific and usually not standardized.
3.14
standard connector
device that is manufactured to an international, regional or national standard which is fitted to the
valve filling connection of a valve with or without RPD (3.2) to allow users to withdraw gas from the
cylinder and which can also be used to fill cylinders having RPVs (3.1) fitted with type 2 RPDs (3.4)
Note 1 to entry: These connectors are usually standardized.
3.15
RPD neutralization device
device fitted to RPVs (3.1) with type 2 RPDs (3.4) to neutralize the RPD (3.2) if so designed and intended
to be neutralized during filling and vacuuming
4 RPV design considerations and requirements
4.1 Design considerations
Design considerations are given in 4.1.1 to 4.1.2 and Annex A.
4.1.1 Resistance against vibration
RPDs should resist leakage of gas due to vibration experienced in transport.
© ISO 2017 – All rights reserved 3

---------------------- Page: 9 ----------------------
ISO 15996:2017(E)

An example of a vibration test is given in Annex C.
4.1.2 Integrity under high flow
RPDs, except when installed outside the filling path in a VIPR, should be able to withstand the dynamic
and thermal loads created by the gas flow during cylinder filling and venting.
An example of an integrity under high flow test is given in Annex D.
NOTE This test covers the practice of venting cylinders prior to filling followed by the cylinder filling
process. It ensures that the seals within the RPD are not displaced or damaged by the high mass flows, high
velocities and low temperatures involved.
4.2 Design requirements
4.2.1 General
RPDs shall operate within specification and be leak tight over a range of service temperatures, from at
least −20 °C to +65 °C in indoor and outdoor environments.
Where higher or lower service temperatures are required, any additional requirements and tests shall
be agreed between the manufacturer and purchaser.
4.2.2 Valve outlet connection
To accommodate the RPD, the internal dimensions of the RPV outlet connection are permitted to differ
from those quoted in the relevant outlet connection standard, provided safety and performance are not
compromised and the modified design does not conflict with corresponding standard connectors.
4.3 Performance requirements for RPDs
4.3.1 Requirements for type 1 and type 2 RPDs
4.3.1.1 Opening pressure and closing-off pressure
The opening pressure and closing-off pressure at room temperature shall meet manufacturer’s
specifications. In addition, the opening pressure and closing-off pressure at low and high temperatures
(see Table 2) shall be measured and recorded to ensure that the RPD functions over the specified
temperature range (see 4.2.1).
To ensure confident and reliable pre-fill checking of cylinders fitted with RPVs, the closing-off pressure
at room temperature shall be no less than 1,5 bar. For specific applications, the closing-off pressure at
room temperature may be reduced if agreed between the manufacturer and the purchaser.
NOTE Applicable regulations and/or standards (e.g. ISO 10524-3) or purchasers can require a higher
minimum closing-off pressure.
The verification of opening pressure and closing-off pressure is given in 5.9.2.
4.3.1.2 Leakage
3
Leakage shall not exceed 6 cm /h corrected to NTP over the range of temperatures specified in Table 2.
3
NOTE Leakage of 6 cm /h is approximately 4 bubbles of 3,5 mm diameter per minute.
4 © ISO 2017 – All rights reserved

---------------------- Page: 10 ----------------------
ISO 15996:2017(E)

4.3.1.3 Endurance
RPDs shall meet the requirements for the opening pressure given in 4.3.1.1 after endurance testing.
NOTE This requirement is in addition to the endurance test specified in ISO 10297, where the RPV is to be
tested with the RPD neutralized using the manufacturer’s recommended method or by using a RPV not fitted
with the RPD.
The endurance test is given in 5.9.3.
After the endurance test and the subsequent tests/verifications have been performed a visual
examination shall be carried out to ensure that no component is displaced (according to the
manufacturer’s drawing), non-functional (e.g. broken or damaged) or missing.
The visual examination is given in 5.9.5.
4.3.1.4 Resistance to ignition
If required by ISO 10297:2014, 5.9, an oxygen pressure surge test shall be carried out.
The oxygen pressure surge test is given in Annex B, except for VIPRs where the test shall be carried out
according to ISO 22435 for industrial applications or ISO 10524-3 for medical applications.
4.3.2 Additional requirements for type 1 RPDs
4.3.2.1 Resistance of the non-return function against pressure in the reverse direction for
type 1 RPDs
Except when installed in a VIPR, type 1 RPDs shall be able to resist a hydraulic pressure of 1,5 × p in
vt
the reverse direction without permanent visible deformation of the metallic components, damage of
non-metallic materials or bursting of the RPD.
NOTE Generally, the strength of all RPVs via the RPV inlet connection is covered by ISO 10297.
The strength test of the non-return-function in the reverse direction for type 1 RPDs is given in 5.9.1.
4.3.2.2 Leak tightness in the reverse direction for type 1 RPDs
Except when installed in a VIPR, type 1 RPDs shall meet the leakage requirements given in 4.3.1.2 at
0,5 bar and p applied in the reverse direction. The leak tightness test in the reverse direction for
vt
type 1 RPDs is given in 5.9.4.
NOTE This test is in addition to the tightness tests given in ISO 10297.
5 RPV type testing
5.1 General
5.1.1 Evaluation of conformity shall be carried out in accordance with the applicable regulations of the
countries of use.
To comply with this document, RPVs shall be type tested.
A type test is valid for a given RPV design.
© ISO 2017 – All rights reserved 5

---------------------- Page: 11 ----------------------
ISO 15996:2017(E)

5.1.2 Some changes within the RPV design which could adversely affect RPD performance require tests
to be repeated using the number of test samples quoted in Table 2 including:
a) increase of RPV test pressure [repetition of all tests except verification of opening pressure and
closing-off pressure, endurance test for type 2 RPDs and (optional) vibration test];
b) change in gas service [addition of releva
...

NORME ISO
INTERNATIONALE 15996
Deuxième édition
2017-07
Bouteilles à gaz — Robinets à pression
résiduelle — Spécifications et essais
de type de robinets de bouteille
intégrant des dispositifs de pression
résiduelle
Gas cylinders — Residual pressure valves — Specification and type
testing of cylinder valves incorporating residual pressure devices
Numéro de référence
ISO 15996:2017(F)
©
ISO 2017

---------------------- Page: 1 ----------------------
ISO 15996:2017(F)

DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2017, Publié en Suisse
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite ni utilisée
sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie, l’affichage sur
l’internet ou sur un Intranet, sans autorisation écrite préalable. Les demandes d’autorisation peuvent être adressées à l’ISO à
l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2017 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 15996:2017(F)

Sommaire Page
Avant-propos .iv
Introduction .vi
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Considérations et exigences relatives à la conception d’un RPV . 4
4.1 Considérations relatives à la conception . 4
4.1.1 Résistance aux vibrations. 4
4.1.2 Intégrité à haut débit . . 4
4.2 Exigences relatives à la conception . 4
4.2.1 Généralités . 4
4.2.2 Raccord de sortie du robinet . 4
4.3 Exigences de performance pour les RPD . . 4
4.3.1 Exigences pour les RPD de type 1 et de type 2 . 4
4.3.2 Exigences complémentaires pour les RPD de type 1 . 5
5 Essai de type d’un RPV . 6
5.1 Généralités . 6
5.2 Documentation . 6
5.3 Échantillons d’essai . 7
5.4 Rapport d’essai . 7
5.5 Températures d’essai . 7
5.6 Pressions d’épreuve . 8
5.6.1 Pression d’épreuve du RPV . 8
5.6.2 Autres pressions d’épreuve . 8
5.7 Gaz d’essai . 8
5.7.1 Qualité du gaz . 8
5.7.2 Vérification de la pression d’ouverture et de la pression de fermeture . 8
5.7.3 Essai d’étanchéité dans le sens inverse pour les RPD de type 1 . 9
5.7.4 Essai d’endurance . 9
5.7.5 Essai de compression adiabatique à l’oxygène . 9
5.7.6 Essai de vibration . 9
5.7.7 Essai d’intégrité à haut débit . 9
5.8 Séquence d’essais . 9
5.9 Essais de performance du RPD .11
5.9.1 Essai de résistance de la fonction anti-retour dans le sens inverse pour les
RPD de type 1 .11
5.9.2 Vérification de la pression d’ouverture et de la pression de fermeture .11
5.9.3 Essai d’endurance .12
5.9.4 Essai d’étanchéité dans le sens inverse pour les RPD de type 1 .12
5.9.5 Examen visuel.12
6 Marquage .12
Annexe A (informative) Considérations relatives à la conception .14
Annexe B (normative) Essai de compression adiabatique à l’oxygène .15
Annexe C (informative) Essai de vibration .16
Annexe D (informative) Essai d’intégrité à haut débit .17
Annexe E (informative) Exemples d’équipement d’essai .19
Bibliographie .22
© ISO 2017 – Tous droits réservés iii

---------------------- Page: 3 ----------------------
ISO 15996:2017(F)

Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes
nationaux de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est
en général confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude
a le droit de faire partie du comité technique créé à cet effet. Les organisations internationales,
gouvernementales et non gouvernementales, en liaison avec l’ISO participent également aux travaux.
L’ISO collabore étroitement avec la Commission électrotechnique internationale (IEC) en ce qui
concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a été
rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir www
.iso .org/ directives).
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de
droits de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable
de ne pas avoir identifié de tels droits de propriété et averti de leur existence. Les détails concernant
les références aux droits de propriété intellectuelle ou autres droits analogues identifiés lors de
l’élaboration du document sont indiqués dans l’Introduction et/ou dans la liste des déclarations de
brevets reçues par l’ISO (voir www .iso .org/ brevets).
Les appellations commerciales éventuellement mentionnées dans le présent document sont données
pour information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un
engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion
de l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles
techniques au commerce (OTC), voir le lien suivant: w w w . i s o .org/ iso/ fr/ avant -propos .html.
Le présent document a été élaboré par le comité technique ISO/TC 58, Bouteilles à gaz, sous-comité SC 2,
Accessoires de bouteilles.
Cette deuxième édition annule et remplace la première édition (ISO 15996:2005), qui a fait l’objet d’une
révision technique. Elle incorpore également l’Amendement ISO 15996:2005/Amd 1:2007.
Les principales modifications par rapport à l’édition précédente sont les suivantes:
a) titre et domaine d’application: extension du domaine en vue de couvrir l’intégralité du robinet
RPV (robinet et dispositif de pression résiduelle) et pas seulement le dispositif de pression
résiduelle (RPD); modification de la référence informative à l’ISO 10297;
b) domaine d’application: inclusion des vannes principales, des robinets de bouteilles à détendeur
intégré (VIPR) et des RPV (robinets à pression résiduelle) pour les fûts à pression et les tubes;
exclusion des gaz dissous, application possible pour les dispositifs RPD autonomes;
c) termes, définitions et symboles: ajout de nouvelles définitions et adaptation de définitions
existantes; ajout de différents types de RPD en remplacement des anciennes descriptions et
modification du classement (anciens types A et B remplacés respectivement par types 2 et 1);
d) considérations relatives à la conception d’un robinet: ajout d’informations sur la conception dans la
nouvelle Annexe A informative;
e) exigences et considérations relatives aux performances:
1) pressions de fermeture et d’ouverture: ajout d’exigences relatives à ces pressions, notamment
valeur minimale pour la pression de fermeture;
2) endurance: réduction du nombre de cycles d’endurance pour les RPD de type 2;
iv © ISO 2017 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 15996:2017(F)

3) examen visuel: ajout d’un examen visuel à l’issue du mode opératoire d’essai;
4) résistance de la fonction anti-retour à la pression dans le sens inverse pour les RPD de type 1:
exclusion des RPD incorporés aux VIPR et adaptation des exigences de succès-échec;
5) étanchéité dans le sens inverse pour les RPD de type 1: exclusion des RPD incorporés aux VIPR;
6) intégrité à haut débit: exclusion des RPD installés hors du circuit de remplissage d’un VIPR;
f) essai de type d’un RPV:
1) généralités: ajout d’informations pour la gestion des modifications de conception d’un RPV;
2) échantillons d’essai: ajout d’exigences portant sur l’usage de raccord(s) de remplissage
approprié(s) lors de l’essai de compression adiabatique à l’oxygène des échantillons;
3) gaz d’essai: ajout d’exigences relatives à l’utilisation et à la qualité des gaz d’essai;
4) séquence d’essais: adaptation en vue de répondre aux nouvelles exigences, ajout d’une pression
d’épreuve et d’une température d’essai; suppression des informations relatives aux variantes;
5) essai de résistance de la fonction anti-retour dans le sens inverse pour les RPD de type 1:
nombre d’échantillons d’essai requis ramené à 1;
6) vérification des pressions d’ouverture et de fermeture: ajout d’une vérification à une
température basse et une température élevée; ajout d’un mode opératoire d’essai détaillé;
7) essai d’étanchéité dans le sens inverse pour les RPD de type 1: modification et clarification
de l’essai d’étanchéité dans le sens de vidange; ajout d’un essai à 0,5 bar appliqué dans le sens
inverse;
8) examen visuel: ajout d’un examen visuel à la séquence d’essais;
9) essai de compression adiabatique à l’oxygène: informations déplacées à l’Annexe B normative;
ajout d’un essai pour les vannes principales; ajout d’informations détaillées sur le mode
opératoire d’essai;
g) marquage: ajout d’exigences relatives au marquage;
h) Annexe A (informative): suppression des exemples de conception de RPV; ajout de considérations
relatives à la conception;
i) Annexe B (normative): déplacement des informations relatives à l’équipement d’essai à l’Annexe D
informative; nouvelle Annexe B traitant des exigences obligatoires applicables à l’essai de
compression adiabatique à l’oxygène;
j) Annexe C (informative): mise à jour de la référence à la norme MIL pour l’essai de vibration;
k) Annexe D (informative): complète modification de l’essai d’intégrité à haut débit (réduction du
nombre d’échantillons d’essai, adaptation des gaz pour lesquels il convient de procéder à un essai
complémentaire avec du dioxyde de carbone, remplacement du dioxyde de carbone liquide par du
dioxyde de carbone gazeux en tant que gaz d’essai, modification du mode opératoire d’essai);
l) Annexe E: nouvelle annexe informative donnant des informations sur l’équipement d’essai (ancienne
Annexe B).
© ISO 2017 – Tous droits réservés v

---------------------- Page: 5 ----------------------
ISO 15996:2017(F)

Introduction
L’augmentation des exigences destinées à éviter la contamination des gaz et des bouteilles a conduit à
mettre au point des robinets comportant des dispositifs de pression résiduelle (RPD), désignés dans le
présent document par le terme «robinets à pression résiduelle» (RPV).
Ces dispositifs sont conçus pour maintenir une pression positive par rapport à l’atmosphère d’une
bouteille, par fermeture des passages internes dans le sens de vidange du gaz. Cela évite que la bouteille
ne soit complètement purgée lorsqu’elle est en service chez le client et prévient toute contamination
atmosphérique si le mécanisme de manœuvre de la vanne (d’arrêt principale) est laissé ouvert. Bon
nombre de ces dispositifs comprennent une fonction anti-retour qui protège la bouteille contre tout
processus de retour de produits en aval.
Le présent document a été élaboré dans le but d’être conforme à l’application du Règlement type de l’ONU.
Compte tenu des modifications décrites dans l’Avant-propos, dès lors qu’un RPV a été homologué
conformément à la précédente version du présent document, il convient que l’organisme en charge de
l’homologation de ce même RPV par rapport à cette nouvelle édition détermine quels essais doivent
être réalisés.
Dans le présent document, l’unité bar est utilisée, en raison de son utilisation universelle dans le
domaine des gaz techniques. Il convient toutefois de noter que le bar n’est pas une unité SI et que l’unité
5 5 2
SI correspondante pour la pression est le Pa (1 bar = 10 Pa = 10 N/m ).
Les valeurs de pression indiquées dans le présent document sont données en tant que pression relative
(pression supérieure à la pression atmosphérique) sauf indication contraire.
vi © ISO 2017 – Tous droits réservés

---------------------- Page: 6 ----------------------
NORME INTERNATIONALE ISO 15996:2017(F)
Bouteilles à gaz — Robinets à pression résiduelle —
Spécifications et essais de type de robinets de bouteille
intégrant des dispositifs de pression résiduelle
1 Domaine d’application
Le présent document spécifie les exigences applicables à la conception, aux essais de type et au
marquage des robinets de bouteille comportant des dispositifs de pression résiduelle, désignés dans le
présent document par le terme «robinets à pression résiduelle» (RPV). Le présent document s’applique
aux types de RPV suivants:
a) les robinets de bouteille destinés à être montés sur des bouteilles à gaz transportables
rechargeables;
b) les vannes principales (à l’exception des robinets à boisseau sphérique) pour cadres de bouteilles;
c) les robinets de bouteille ou robinets de bouteille à détendeur intégré (VIPR);
d) les robinets pour les fûts à pression et les tubes;
utilisés pour transporter des gaz comprimés ou liquéfiés.
NOTE Lorsqu’il n’existe aucun risque d’ambiguïté, les bouteilles, fûts à pression, tubes et cadres de bouteilles
sont désignés par le terme générique «bouteille» dans le présent document.
Ces exigences s’ajoutent à celles de l’ISO 10297.
Le présent document peut également être appliqué aux dispositifs RPD autonomes.
Le présent document ne s’applique pas aux RPV destinés aux extincteurs d’incendie portables, aux
équipements cryogéniques, aux gaz réfrigérants à basse pression (pression d’épreuve de la bouteille
inférieure à 50 bar), aux gaz dissous ou aux gaz de pétrole liquéfié (GPL).
2 Références normatives
Les documents suivants cités dans le texte constituent, pour tout ou partie de leur contenu, des
exigences du présent document. Pour les références datées, seule l’édition citée s’applique. Pour les
références non datées, la dernière édition du document de référence s’applique (y compris les éventuels
amendements).
ISO 10286, Bouteilles à gaz — Terminologie
ISO 10297:2014, Bouteilles à gaz — Robinets de bouteilles — Spécifications et essais de type
ISO 10524-3, Détendeurs pour l’utilisation avec les gaz médicaux — Partie 3: Détendeurs intégrés dans les
robinets des bouteilles de gaz (VIPR)
ISO 22435, Bouteilles à gaz — Robinets de bouteilles avec détendeur intégré — Spécifications et essais de type
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions de l’ISO 10286, l’ISO 10297 ainsi que les
suivants, s’appliquent.
© ISO 2017 – Tous droits réservés 1

---------------------- Page: 7 ----------------------
ISO 15996:2017(F)

L’ISO et l’IEC tiennent à jour des bases de données terminologiques destinées à être utilisées en
normalisation, consultables aux adresses suivantes:
— ISO Online browsing platform: disponible à l’adresse http:// www .iso .org ./ obp
— IEC Electropedia: disponible à l’adresse http:// www .electropedia .org/
3.1
robinet à pression résiduelle
RPV
robinet intégrant un dispositif de pression résiduelle (3.2)
Note 1 à l’article: Le terme «robinet» couvre les robinets répertoriés à l’Article 1, a) à d).
3.2
dispositif de pression résiduelle
RPD
dispositif qui est conçu pour éviter l’entrée des contaminants en maintenant, dans la bouteille, une
pression positive par rapport à l’atmosphère, par fermeture des passages internes dans le sens de
vidange du gaz
Note 1 à l’article: Cette définition peut différer de celles données dans les réglementations de transport
applicables.
3.3
RPD de type 1
RPD (3.2) qui maintient dans la bouteille une pression positive supérieure à la pression en aval de la
sortie du robinet, et qui intègre une fonction anti-retour pour empêcher tout processus de retour de
produits dans la bouteille provenant d’une pression plus élevée sur le robinet de sortie
Note 1 à l’article: Le remplissage ou le tirage au vide des bouteilles avec des RPV dotés d’un RPD de type 1 entre le
raccord de remplissage et la bouteille n’est pas possible tant que le RPD n’est pas neutralisé; sinon un raccord de
remplissage spécial est utilisé pour neutraliser la fonction anti-retour.
3.4
RPD de type 2
RPD (3.2) qui maintient dans la bouteille une pression positive supérieure à la pression atmosphérique
mais qui n’empêche pas le processus de retour de produits dans la bouteille si la pression au niveau
du robinet de sortie est suffisamment élevée pour neutraliser le mécanisme du RPD et la pression
résiduelle de la bouteille
Note 1 à l’article: Les bouteilles avec des RPV dotés d’un RPD de type 2 peuvent être remplies avec un raccord de
remplissage conventionnel, mais, si les RPV sont entre le raccord de remplissage et la bouteille, le tirage au vide
ou la vidange des bouteilles sous la pression de fermeture n’est possible que si le RPD est neutralisé ou qu’un
raccord de remplissage spécial est utilisé.
3.5
sens de vidange
trajet emprunté par le gaz à travers le RPD (3.2) pendant la vidange de la bouteille via le raccord de sortie
3.6
sens inverse
trajet emprunté par le gaz en direction du RPD (3.2) dans le sens opposé au sens de vidange (3.5)
3.7
sens de remplissage
trajet emprunté par le gaz à travers le RPV (3.1) pendant le remplissage de la bouteille
Note 1 à l’article: Selon la conception du RPV (3.1), le sens de remplissage et le sens inverse (3.6) peuvent être
identiques.
2 © ISO 2017 – Tous droits réservés

---------------------- Page: 8 ----------------------
ISO 15996:2017(F)

3.8
pression d’ouverture
pression différentielle, existant entre la pression en amont et la pression en aval du RPD (3.2), à laquelle
le RPD commence à s’ouvrir pour permettre au gaz de s’écouler dans le sens de vidange (3.5)
Note 1 à l’article: Compte tenu des tolérances de fabrication, cette pression est normalement exprimée sous forme
d’une plage de pressions.
3.9
pression de fermeture
pression de la bouteille à laquelle la fermeture étanche du RPD (3.2) se produit pendant le soutirage du
gaz via le raccord de sortie
Note 1 à l’article: Compte tenu des tolérances de fabrication et des différents débits de vidange, cette pression est
exprimée sous forme d’une plage de pressions.
3.10
pression de service du RPV
p
w
pression stabilisée d’un gaz comprimé, à une température de référence uniforme de 15 °C, dans une
bouteille pleine pour laquelle le RPV (3.1) est prévu
Note 1 à l’article: Cette définition ne s’applique pas aux gaz liquéfiés (par exemple dioxyde de carbone) ni aux gaz
dissous (par exemple acétylène).
Note 2 à l’article: La pression de service du RPV est exprimée en bar.
3.11
pression d’épreuve du RPV
p
vt
pression appliquée à un RPV (3.1) pendant un essai
Note 1 à l’article: La pression d’épreuve du RPV est une valeur minimale exprimée en bar.
3.12
température et pression normales (NTP)
conditions normales de température et de pression, à savoir 20,0 °C (293,15 K), 1,013 bar absolu
(0,101 3 MPa absolu)
3.13
raccord de remplissage RPV
dispositif monté sur le raccord de remplissage des RPV (3.1) dotés de RPD de type 1 (3.3) pendant le
remplissage pour neutraliser la fonction anti-retour, et pendant la vidange et le tirage au vide pour
les RPD de type 1 et de type 2 (3.4)
Note 1 à l’article: Les raccords de ce type ont une conception spécifique et ne sont généralement pas normalisés.
3.14
raccord standard
outil fabriqué conformément à une norme internationale, régionale ou nationale, qui est monté sur
le raccord de remplissage d’un robinet avec ou sans RPD (3.2) afin de permettre aux utilisateurs de
soutirer du gaz de la bouteille et qui peut également être utilisé pour remplir les bouteilles équipées
de RPV (3.1) avec des RPD de type 2 (3.4)
Note 1 à l’article: Les raccords de ce type sont généralement normalisés.
3.15
raccord pousse-clapet du RPD
outil monté sur les RPV (3.1) équipés de RPD de type 2 (3.4) et permettant de neutraliser le RPD (3.2) si
la conception de ce dernier prévoit une neutralisation pendant le remplissage et le tirage au vide
© ISO 2017 – Tous droits réservés 3

---------------------- Page: 9 ----------------------
ISO 15996:2017(F)

4 Considérations et exigences relatives à la conception d’un RPV
4.1 Considérations relatives à la conception
Des considérations relatives à la conception sont données en 4.1.1 à 4.1.2 et dans l’Annexe A.
4.1.1 Résistance aux vibrations
Il convient que les RPD résistent aux fuites de gaz générées par les vibrations subies pendant le
transport.
L’Annexe C donne un exemple d’essai de résistance aux vibrations.
4.1.2 Intégrité à haut débit
Il convient que les RPD, sauf s’ils sont montés hors du circuit de remplissage d’un VIPR, résistent aux
contraintes dynamiques et thermiques générées par l’écoulement de gaz pendant le remplissage et la
vidange de la bouteille.
L’Annexe D donne un exemple d’essai d’intégrité à haut débit.
NOTE Cet essai couvre le processus de vidange des bouteilles avant leur remplissage, suivi du processus
de remplissage des bouteilles. Il permet ainsi de vérifier que les joints à l’intérieur du RPD ne sont ni déplacés
ni endommagés sous l’effet des débits élevés, des hautes vitesses et des températures basses impliqués dans ces
processus.
4.2 Exigences relatives à la conception
4.2.1 Généralités
Les RPD doivent fonctionner conformément aux spécifications et doivent être étanches dans une plage
de températures de service comprise au minimum entre −20 °C et +65 °C, en intérieur comme en
extérieur.
Lorsque des températures de service supérieures ou inférieures sont exigées, les exigences et essais
complémentaires doivent faire l’objet d’un accord entre le fabricant et l’acheteur.
4.2.2 Raccord de sortie du robinet
Afin de tenir compte du montage du RPD, les dimensions internes du raccord de sortie du RPV peuvent
différer de celles indiquées dans la norme de raccord de sortie appropriée, sous réserve que la sécurité
et les performances ne soient pas compromises et que la conception ainsi modifiée ne soit pas en conflit
avec les raccords standards correspondants.
4.3 Exigences de performance pour les RPD
4.3.1 Exigences pour les RPD de type 1 et de type 2
4.3.1.1 Pression d’ouverture et pression de fermeture
La pression d’ouverture et la pression de fermeture à la température ambiante doivent être conformes
aux spécifications du fabricant. En outre, la pression d’ouverture et la pression de fermeture à des
températures basses et élevées (voir Tableau 2) doivent être mesurées et enregistrées afin de s’assurer
que le RPD fonctionne sur la plage de températures spécifiée (voir 4.2.1).
Pour garantir une vérification fiable avant remplissage des bouteilles équipées de RPV, la pression
de fermeture à la température ambiante ne doit pas être inférieure à 1,5 bar. Pour les applications
4 © ISO 2017 – Tous droits réservés

---------------------- Page: 10 ----------------------
ISO 15996:2017(F)

spécifiques, la pression de fermeture à la température ambiante peut être réduite sous réserve d’un
accord préalable entre le fabricant et l’acheteur.
NOTE Les réglementations et/ou nomes applicables (par exemple ISO 10524-3) ou les acheteurs peuvent
exiger une pression de fermeture minimale supérieure.
La vérification de la pression d’ouverture et de la pression de fermeture est indiquée en 5.9.2.
4.3.1.2 Débit de fuite
3
Le débit de fuite ne doit pas excéder 6 cm /h exprimés dans les conditions normales de température et
de pression, sur la plage de températures spécifiée au Tableau 2.
3
NOTE Un d
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.