Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary use at non-weatherprotected locations

The present document specifies test methods and severities for verification of the required resistibility of equipment according to the relevant environmental class. The tests defined in Part 2-4 of this multi-part standard apply to stationary use of equipment at non-weatherprotected locations covering the environmental conditions stated in ETS 300 019-1-4 [1].

Inženiring opreme (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 2-4. del: Specifikacija preskusov vplivov okolja – Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi

General Information

Status
Published
Publication Date
31-Jan-2006
Withdrawal Date
30-Sep-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Standard

Standard
EN 300 019-2-4 V2.1.2:2006
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 019-2-4 V2.1.2:2006
01-februar-2006
,QåHQLULQJRSUHPH (( ±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO6SHFLILNDFLMDSUHVNXVRYYSOLYRYRNROMD±
)LNVQDXSRUDEDQDORNDFLMDKNLQLVR]DãþLWHQHSUHGYUHPHQVNLPLYSOLYL
Equipment Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary
use at non-weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-2-4 Version 2.1.2
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-2-4 V2.1.2:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006

---------------------- Page: 2 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
ETSI EN 300 019-2-4 V2.1.2 (1999-09)
European Standard (Telecommunications series)
Equipment Engineering (EE);
Environmental conditions and environmental tests for
telecommunications equipment;
Part 2-4: Specification of environmental tests;
Stationary use at non-weatherprotected locations

---------------------- Page: 3 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
2 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
Reference
REN/EE-01027-2-4 (06cj10dc.PDF)
Keywords
environment
ETSI
Postal address
F-06921 Sophia Antipolis Cedex - FRANCE
Office address
650 Route des Lucioles - Sophia Antipolis
Valbonne - FRANCE
Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Internet
secretariat@etsi.fr
Individual copies of this ETSI deliverable
can be downloaded from
http://www.etsi.org
If you find errors in the present document, send your
comment to: editor@etsi.fr
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1999.
All rights reserved.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
3 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
Contents
Intellectual Property Rights . 4
Foreword. 4
1 Scope. 5
2 References . 5
3 Environmental test specifications. 5
3.1 Specification T 4.1: Non-weatherprotected locations. 6
3.2 Specification T 4.1E: Non-weatherprotected locations - extended. 8
4 Earthquake test specification. 11
4.1 Vibration response investigation. 11
4.2 Test conditioning . 11
5 Notes to tables . 13
5.1 General note. 13
5.2 Notes to tables 1 to 4 . 13
Bibliography . 16
History. 17
ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
4 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect
of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server
(http://www.etsi.org/ipr).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)
which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document consists of 2 parts as follows:
Part 1: "Classification of environmental conditions".
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
Part 2: "Specification of environmental tests".
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
Each part of the standard is divided into sub-parts. Sub-part 2-0 forms a general overview of Part 2.
This sub-part 2-4 deals with stationary use at non-weatherprotected locations.
National transposition dates
Date of adoption of this EN: 3 September 1999
Date of latest announcement of this EN (doa): 31 December 1999
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 30 June 2000
Date of withdrawal of any conflicting National Standard (dow): 30 June 2000
ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
5 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
1 Scope
The present document specifies test methods and severities for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in Part 2-4 of this multi-part standard apply to stationary use of equipment at non-weatherprotected
locations covering the environmental conditions stated in ETS 300 019-1-4 [1].
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication, edition number, version number, etc.) or non-
specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
• A non-specific reference to an ETS shall also be taken to refer to later versions published as an EN with the same
number.
[1] ETS 300 019-1-4: "Equipment Engineering (EE); Environmental conditions and environmental
tests for telecommunications equipment; Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations".
[2] IEC 60068-2: "Environmental testing - Part 2: Tests".
[3] ETS 300 019-2-0: "Equipment Engineering (EE); Environmental conditions and environmental
tests for telecommunications equipment; Part 2-0: Specification of environmental tests;
Introduction".
[4] Void.
[5] Void.
[6] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of ETS 300 019-1- 4 [1].
ETS 300 019-2-0 [3] forms a general overview of Part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in the present
document unless otherwise stated. The required performance before, during and after the test need to be specified in the
product specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it
shall be minimized.
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
6 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
3.1 Specification T 4.1: Non-weatherprotected locations
This specification applies to many member countries of ETSI. See tables 1 and 3.
Table 1: Test specification T 4.1: Stationary use at non-weatherprotected locations-climatic tests
Environmental parameter Environmental Environmental test specification T4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
(°C) -33 -33 or -45 16 h IEC 60068-2-1 Ab/Ad: Cold 1
low
Air high (°C) +40 +40 or +55 16 h IEC 60068-2-2 Bb/Bd: Dry heat 2
temperature
change (°C) -10 / +40 2 cycles IEC 60068-2-14 Nb: Change of 3
(°C/min) 0,5 0,5 t = 3 h temperature
1
low (%) 15 none 8
relative high (%) 100 93 21 d IEC 60068-2-56 Cb: Damp heat 4
(°C) +30 steady state
Humidity condensation yes 5
 (%) 90-100 6 cycles IEC 60068-2-30 Db: Damp heat,
(°C) +30 cyclic Variant 1
3
low  (g/m ) 0,26 none
absolute
3
high  (g/m)25 6
pressure low  (kPa) 70 none 7
Air high  (kPa) 106 none 7
speed  (m/s) 50 none 8
3 2
rain intensity 6 mm/min 0,01 m /min 90 3 min/m or IEC 60068-2-18 Rb: Impacting 9
kPa 15 min water Method 2.2
Water low temperature (°C) +5 none
other sources splashing water 10
icing & frosting yes none 8
2
Radiation solar (W/m ) 1 120 11
2
heat (W/m ) negligible
ETSI

---------------------- Page: 8 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
7 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
3
sulphur SO  (mg/m ) 0,3/1,0 none 12
2
3
H2S  (mg/m ) 0,1/0,5 none 12
salt mist sea and road salt none 12
3
Chemically chlorine Cl2  (mg/m ) 0,1/0,3 none 12
3
active HCI  (mg/m ) 0,1/0,5 none 12
3
substances nitrogen NOx  (mg/m ) 0,5/1,0 none 12
3
NH  (mg/m ) 1,0/3,0 none 12
3
3
hydrogen fluoride  (mg/m ) 0,01/0,03 none 12
HF
3
ozone O  (mg/m ) 0,05/0,1 none 12
3
Mechanically dust sedimentation 20 13
2
(mg/(m h))
3
active suspension  (mg/m)5 13
3
substances sand  (mg/m ) 300 13
Flora and micro organisms mould, fungus, etc. none 14
fauna rodents, insects rodents, etc. none 14
NOTE 1: none = verification is required only in special cases.
NOTE 2: n = number of note, see clause 5.
ETSI

---------------------- Page: 9 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
 (76,(19 
 6SHFLILFDWLRQ7(1RQZHDWKHUSURWHFWHGORFDWLRQVH[WHQGHG
7KLVVSHFLILFDWLRQDSSOLHVWRDOOPHPEHUFRXQWULHVRI(76,6HHWDEOHVDQG
7DEOH7HVWVSHFLILFDWLRQ7(6WDWLRQDU\XVHDWQRQZHDWKHUSURWHFWHGORFDWLRQVH[WHQGHGFOLPDWLFWHVWV
(QYLURQPHQWDOSDUDPHWHU (QYLURQPHQWDO (QYLURQPHQWDOWHVWVSHFLILFDWLRQ7(6WDWLRQDU\XVH
&ODVV( 1RQZHDWKHUSURWHFWHGORFDWLRQVH[WHQGHG
7\SH 3DUDPHWHU 'HWDLOSDUDPHWHU &KDUDFWHULVWLF 7HVWVHYHULW\ 'XUDWLRQ 5HIHUHQFH 0HWKRG 1RWHV
VHYHULW\
ORZ ƒ&  RU K ,(& $E$G&ROG 
$LU KLJK ƒ&  RU K ,(& %E%G'U\KHDW 
WHPSHUDWXUH FKDQJH ƒ&  F\FOHV ,(& 1E&KDQJHRI 
ƒ&PLQ   W K WHPSHUDWXUH
ORZ    QRQH 
KLJK     G ,(& &E'DPSKHDW 
UHODWLYH  ƒ&  VWHDG\VWDWH
+XPLGLW\ FRQGHQVDWLRQ \HV ƒ& F\FOHV ,(& 'E'DPSKHDW 
F\FOLF9DULDQW
DEVROXWH ORZ JP  QRQH 
KLJK JP 
SUHVVXUH ORZ N3D  QRQH 
$LU KLJK N3D  QRQH 
VSHHG PV  QRQH 
UDLQ LQWHQVLW\ PPPLQ P PLQN3D PLQP RU ,(& 5E,PSDFWLQJZDWHU 
PLQ 0HWKRG
:DWHU ORZWHPSHUDWXUH  ƒ&  QRQH
RWKHUVRXUFHV VSODVKLQJZDWHU 
LFLQJ IURVWLQJ \HV QRQH 
5DGLDWLRQ VRODU :P  
KHDW :P QHJOLJLEOH
(76,

---------------------- Page: 10 ----------------------

SIST EN 300 019-2-4 V2.1.2:2006
9 ETSI EN 300 019-2-4 V2.1.2 (1999-09)
Environmental parameter Environmental Environmental test specification T4.1E: Stationary use
Class 4.1E Non-weatherprotected locations - e
...

Questions, Comments and Discussion