31 - Automatic identification and data capture techniques
Standardization of data formats, data syntax, data structures, data encoding, and technologies for the process of automatic identification and data capture and of associated devices utilized in inter-industry applications and international business interchanges and for mobile applications.
Techniques d'identification et de captage automatiques des données
Préparer et maintenir des normes internationales concernant le matériel électrique utilisable dans les atmosphères explosibles sous forme de gaz, vapeurs, brouillards ou poussières combustibles.
General Information
IEC 60079-25:2020 contains the specific requirements for design, construction and assessment of intrinsically safe systems, Type of Protection “i”, intended for use, as a whole or in part, in locations in which the use of Group I, II or III Ex Equipment is required.
This document supplements and modifies the general requirements of IEC 60079-0 and the intrinsic safety standard IEC 60079-11. Where a requirement of this standard conflicts with a requirement of IEC 60079-0 or IEC 60079-11, the req...view more
- Standard117 pagesEnglish and French language
world standards week 25% off
- Standard9 pagesEnglish and French language
world standards week 25% off
IEC 60050-426:2020 gives terms specifically relevant to explosive atmospheres. This new edition reviews and complements the previous one. This terminology is consistent with the terminology developed in the other specialized parts of the IEV.
It has the status of a horizontal standard in accordance with IEC Guide 108.
- Standard430 pagesEnglish and French language
world standards week 25% off
- Standard14 pagesEnglish and French language
world standards week 25% off
IEC 60079-19:2019 gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of equipment designed for use in explosive atmospheres; it is not applicable to maintenance, other than when repair and overhaul cannot be disassociated from maintenance, neither does it give advice on cable entry systems which may require a renewal when the equipment is re-installed.
This fourth edition cancels and replaces the third edition published in 2010 together ...view more
- Standard166 pagesEnglish and French language
world standards week 25% off
IEC 62990-1:2019 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is t...view more
- Standard124 pagesEnglish and French language
world standards week 25% off
IEC TS 60079-42:2019 provides guidance for equipment manufacturers where electrical safety devices are used to reduce the likelihood of potential ignition sources becoming effective in Ex Equipment located in Explosive Atmospheres. Electrical safety devices perform a safety function to control potential ignition sources from both, electrical or non-electrical Ex Equipment in explosive atmospheres.
This Technical Specification may also be applied to a combination of elements performing a safety ...view more
- Technical specification48 pagesEnglish and French language
world standards week 25% off
ISO/IEC 80079-34:2018 specifies particular requirements and information for establishing and maintaining a quality management system to manufacture Ex Products in accordance with the certificates. While it does not preclude the use of other quality management systems that are compatible with the objectives of ISO 9001:2015 and which provide equivalent results, the minimum requirements are given in this document. This second edition cancels and replaces the first edition, published in 2011, and c...view more
- Standard140 pagesEnglish and French language
world standards week 25% off
ISO/IEC 80079-20-1: 2017 is published as a dual log standard and provides guidance on classification of gases and vapours. It describes a test method intended for the measurement of the maximum experimental safe gaps (MESG) for gas-air mixtures or vapour-air mixtures under normal conditions of temperature and pressure (20 °C, 101,3 kPa) so as to permit the selection of an appropriate group of equipment. This document also describes a test method intended for use in the determination of the auto-...view more
- Standard176 pagesEnglish and French language
world standards week 25% off
IEC 60079-0:2017 is also available as IEC 60079-0:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-0:2017 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assum...view more
- Standard279 pagesEnglish and French language
world standards week 25% off- Standard133 pagesEnglish language
world standards week 20% off- e-Library read for1 day
IEC 60079-15:2017 is available as IEC 60079-15:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-15:2017 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended...view more
- Standard63 pagesEnglish and French language
world standards week 25% off
IEC TS 60079-43:2017(E) which is a Technical Specification, provides guidance for equipment for use in explosive atmospheres in environments which may include ambient temperatures below -20 °С, and additional adverse conditions, including maritime applications. The purpose of this document is to provide recommendations to be considered for the design, manufacture and use of equipment. It is intended that this document be used for equipment operating within the environmental range specified on th...view more
- Technical specification17 pagesEnglish language
world standards week 25% off
IEC TS 60079-46:2017 specifies requirements for the design, construction, assembly, testing, inspection, marking, documenting and assessment of equipment assemblies for use in explosive atmospheres under the responsibility of the manufacturer of the equipment assembly. The requirements of this document apply to individual items according to the IEC 60079 series or ISO 80079 series that comprise the assembly and that have individual certificates. These individual items are then integrated as part...view more
- Technical specification33 pagesEnglish and French language
world standards week 25% off
- Standard5 pagesEnglish and French language
world standards week 25% off
- Standard5 pagesEnglish and French language
world standards week 25% off
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization;
– located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation;
– located in a non-hazardous area, containing an i...view more
- Standard72 pagesEnglish and French language
world standards week 25% off
- Technical specification12 pagesEnglish and French language
world standards week 25% off- Technical specification6 pagesEnglish language
world standards week 25% off
IEC 60079-29-1:2016 specifies general requirements for construction, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the detection and measurement of flammable gas or vapour concentrations with air. The equipment, or parts thereof, is intended for use in explosive atmospheres and in mines susceptible to firedamp. This second edition of IEC 60079-29-1 cancels and replaces the first edition of IEC 60079-29-1:2007 series and cons...view more
- Standard95 pagesEnglish and French language
world standards week 25% off
ISO 80079-36:2016 specifies the basic method and requirements for design, construction, testing and marking of non-electrical Ex equipment, Ex Components, protective systems, devices and assemblies of these products that have their own potential ignition sources and are intended for use in explosive atmospheres. Hand tools and manually operated equipment without energy storage are excluded from the scope of this standard. This standard does not address the safety of static autonomous process equ...view more
- Standard174 pagesEnglish and French language
world standards week 25% off
ISO 80079-37:2016 specifies the requirements for the design and construction of non-electrical equipment, intended for use in explosive atmospheres, protected by the types of protection constructional safety "c", control of ignition source "b" and liquid immersion "k". This part of ISO/IEC 80079 supplements and modifies the requirements in ISO 80079-36. Where a requirement of this standard conflicts with the requirement of ISO 80079-36 the requirement of this standard takes precedence. Types of ...view more
- Standard103 pagesEnglish and French language
world standards week 25% off