ISO/TC 147/SC 2/WG 70 - TOC, DOC, TNb, DNb
COT, COD, azote lié total (TNb), azote lié dissous (DNb)
General Information
This document specifies a multi‑parameter method for the determination of total organic carbon (TOC), total nitrogen (TNb) and total phosphorus (TP) in drinking water, raw water, ground water, surface water, sea water, saline water, process water, domestic and industrial wastewater, after a chemical oxidation process. It is applicable to both dissolved and bound suspended materials. The method allows for determination of TOC, TN and TP. The lower and upper working ranges for these parameters are dependent upon instrument conditions (for example sample volume, reaction chemistry amounts) and can be adjusted for a wider range. Typical measurement ranges are shown in Figures C.1 to C.3. The analysis procedure is carried out instrumentally by a single oxidation process. Dissolved nitrogen gas is not included in the TNb measurement in this method. When present in the sample, elemental carbon, cyanate and thiocyanate will be included in the TOC result.
- Standard31 pagesEnglish languagesale 15% off
- Standard31 pagesEnglish languagesale 15% off
This document specifies a method for the determination of total organic carbon (TOC), dissolved organic carbon (DOC), total bound nitrogen (TNb) and dissolved bound nitrogen (DNb) in the form of free ammonia, ammonium, nitrite, nitrate and organic compounds capable of conversion to nitrogen oxides under the conditions described. The procedure is carried out instrumentally. NOTE Generally the method can be applied for the determination of total carbon (TC) and total inorganic carbon (TIC), see Annex A. The method is applicable to water samples (e.g. drinking water, raw water, ground water, surface water, sea water, waste water, leachates). The method allows a determination of TOC and DOC ≥ 1 mg/l and TNb and DNb ≥ 1 mg/l. The upper working range is restricted by instrument-dependent conditions (e.g. injection volume). Higher concentrations can be determined after appropriate dilution of the sample. For samples containing volatile organic compounds (e.g. industrial waste water), the difference method is used, see Annex A. Cyanide, cyanate and particles of elemental carbon (soot), when present in the sample, can be determined together with the organic carbon. The method is not appropriate for the determination of volatile, or purgeable, organic carbon under the conditions described by this method. Dissolved nitrogen gas (N2) is not determined.
- Standard18 pagesEnglish languagesale 15% off
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day