This document specifies:
a) field of application;
b) requirements for in line anti-vacuum valves;
c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of in-line anti-vacuum valves DN 10 to DN 50;
d) test method and requirements for verifying these properties;
e) marking and presentation;
f) acoustics.
This document specifies the characteristics of in-line anti-vacuum valves DN 10 to DN 50 that are suitable for use in drin...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft22 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the general requirements for metallic check valves, which are forged, cast or fabricated in straight, angle or oblique pattern (see EN 736‐2) with end connections flanged or wafer, butt welding, socket welding, or threaded.
This document applies to metallic check valves used for all industrial applications.
Additional requirements given in the relevant application standards may apply to check valves used for more specific applications (e.g. for the water industry, the c...view more
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft16 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the general requirements for metallic check valves, which are forged, cast or fabricated in straight, angle or oblique pattern (see EN 736‐2) with end connections flanged or wafer, butt welding, socket welding, or threaded.
This document applies to metallic check valves used for all industrial applications.
Additional requirements given in the relevant application standards may apply to check valves used for more specific applications (e.g. for the water industry, the c...view more
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft16 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment12 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment12 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day
- Standard6 pagesFrench language
sale 15% off- Standard5 pagesEnglish language
sale 15% off
ISO 19240:2017 specifies requirements for design, dimensions, material, fabrication and production testing of lined metal quarter turns valves (plug valves, butterfly valves, ball valves) and check valves with flanged, wafer and wafer lug body types. It covers valves of the nominal sizes, DN: - 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 750, 800, 900, 1 000, 1 200; corresponding to nominal pipe sizes, NPS 1/2 to NPS 48, and applies to pressure des...view more
- Standard7 pagesEnglish language
sale 15% off
EN 16447 describes the general requirements for flap valves used for dust explosion isolation. An explosion isolation flap valve is a protective system, which prevents a dust explosion from propagating via connecting pipes or ducts into other parts of apparatus or plant areas. An explosion isolation flap valve can only stop the propagation of a dust explosion when it propagates against the direction of the normal process flow. It does not stop explosions running in the normal process flow direct...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard describes the general requirements for flap valves used for dust explosion isolation. An explosion isolation flap valve is a protective system, which prevents a dust explosion from propagating via connecting pipes or ducts into other parts of apparatus or plant areas.
An explosion isolation flap valve can only stop the propagation of a dust explosion when it propagates against the direction of the normal process flow. It does not stop explosions running in the normal proc...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements for steel globe and globe stop and check valves which are wrought, cast or fabricated in straight, angle or oblique pattern with end connections flanged, butt welding, socket welding or threaded.
This standard is applicable to steel globe and globe stop and check valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standards are ...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the requirements for steel globe and globe stop and check valves which are wrought, cast or fabricated in straight, angle or oblique pattern with end connections flanged, butt welding, socket welding or threaded.
This standard is applicable to steel globe and globe stop and check valves mainly used for industrial and general purpose applications. However, they can be used for other applications provided the requirements of the relevant performance standards are ...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies the field of application, the dimensional, the physico-chemical, the design, the hydraulic, the mechanical, and the acoustic characteristics of in-line anti vacuum valve family D Type A.
This document covers in-line anti vacuum valve family D Type A, intended to prevent pollution of potable water by backflow, caused by backsiphoning only.
It is applicable to in-line anti vacuum valve in denominations DN 10 up to DN 50.
It covers in-line anti vacuum valve of PN 10 that ...view more
- Standard22 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft22 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements and tests for check valves of thermoplastics materials with the function to allow the flow of liquid fluids through the valve in one direction only and to prevent backflow.
This standard is applicable to check valves to be installed in industrial pipe systems, irrespective of the field of application and the liquid fluids to be conveyed. For other and/or special applications special requirements may apply.
The range of DN is:
DN 8, DN 10, DN 15, D...view more
- Standard21 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 16137:2006 specifies requirements for the design, functional characteristics and manufacture of check valves made of thermoplastics materials intended to allow the flow of liquid fluids through the valve in one direction only and to prevent backflow, their connection to the pipe system, the body materials and their pressure/temperature rating between -40 degrees Celsius and + 120 degrees Celsius, for a lifetime of 25 years, and also specifies their tests.
ISO 16137:2006 is applicable to va...view more
- Standard21 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Report gives guidance in support of Directives adopted by the European Union in the Food Contact Materials Sector and is intended to aid Food Control Authorities and industry enforce and comply with those Directives.
- Technical report44 pagesEnglish language
sale 10% off- e-Library read for1 day
ISO 16137:2006 specifies requirements for the design, functional characteristics and manufacture of check valves made of thermoplastics materials intended to allow the flow of liquid fluids through the valve in one direction only and to prevent backflow, their connection to the pipe system, the body materials and their pressure/temperature rating between -40 degrees Celsius and + 120 degrees Celsius, for a lifetime of 25 years, and also specifies their tests. ISO 16137:2006 is applicable to valv...view more
- Standard14 pagesEnglish language
sale 15% off- Standard15 pagesFrench language
sale 15% off
This document specifies:
a) field of application;
b) requirements for pipe interrupters with atmospheric vent and moving element;
c) dimensional and the physico-chemical properties, and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with elastic membrane of DN 10 to DN 20;
d) test procedure and requirements for verifying these properties;
e) marking and presentation;
f) acoustics.
This document specifies the characteristics of pipe interrupters w...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies:
a) field of application;
b) requirements for pipe interrupters with permanent atmospheric vent;
c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20;
d) test method and requirements for verifying these properties;
e) marking and presentation;
f) acoustics.
This document specifies the characteristics of pipe interrupters with perma...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies:
a) field of application;
b) requirements for pipe interrupters with atmospheric vent and moving element;
c) dimensional and the physico-chemical properties, and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with elastic membrane of DN 10 to DN 20;
d) test procedure and requirements for verifying these properties;
e) marking and presentation;
f) acoustics.
This document specifies the characteristics of pipe interrupters w...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies:
a) field of application;
b) requirements for pipe interrupters with permanent atmospheric vent;
c) dimensional, the physico-chemical properties and the properties of general hydraulic, mechanical and acoustic design of pipe interrupters with permanent atmospheric vent, DN 10 to DN 20;
d) test method and requirements for verifying these properties;
e) marking and presentation;
f) acoustics.