M/095 - In vitro diagnostic (prog.)
In vitro diagnostic (prog.)
General Information
Former prEN 61010-2-081 * D124/130: BTTF 88-1 disbanded - Work referred to SR 66
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote * D124/135: BTTF 88-1 disbanded - Work referred to SR 66
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
This Standard gives the measurement method of the total input power for ballast-lamp circuits when operating with their associated fluorescent lamp(s). This standard applies to electrical ballast-lamp circuits comprised solely of the ballast and of the lamp(s). NOTE: Requirements for testing individual ballasts during production are not included. It specifies the measurement method for the total input power for all ballasts sold for domestic and normal commercial purposes operating with the following fluorescent lamps: linear lamps with power equal to or greater than 15 W; single ended (compact) lamps with power equal to or greater than 18 W; other general purpose lamps. This standard does not apply to: ballasts which form an integral part of the lamp; ballast-lamp circuits with capacitors connected in series; controllable wire-wound magnetic ballasts; luminaires, which rely on additional optical performance aspects
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day
EN following parallel vote * Superseded by EN 61010-2-040:2005
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to equipment intended for in vitro diagnostic (IVD) medical purposes. This is used for the examination of specimens, including blood and tissue samples, derived from the human body. The standard also covers self-test IVD medical equipment for use by lay persons.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying characteristics of samples, performing the process without manual intervention. Examples of such equipment are: analytical equipment, automatic sampler (e.g. pipettor), equipment for sample replication and amplification.
- Standard23 pagesEnglish languagesale 10% offe-Library read for1 day
Applies to washer disinfectors and other equipment used for washing and disinfection. This is for the treatment of soiled items used in the medical, vetinary, pharmaceutical and laboratory fields. For domestic dishwashers see EN 60335-2-5, for commercial dishwashers see EN 60335-2-58.
- Standard30 pagesEnglish languagesale 10% offe-Library read for1 day
This Standard gives the measurement method of the total input power for ballast-lamp circuits when operating with their associated fluorescent lamp(s). This standard applies to electrical ballast-lamp circuits comprised solely of the ballast and of the lamp(s). NOTE: Requirements for testing individual ballasts during production are not included. It specifies the measurement method for the total input power for all ballasts sold for domestic and normal commercial purposes operating with the following fluorescent lamps: linear lamps with power equal to or greater than 15 W; single ended (compact) lamps with power equal to or greater than 18 W; other general purpose lamps. This standard does not apply to: ballasts which form an integral part of the lamp; ballast-lamp circuits with capacitors connected in series; controllable wire-wound magnetic ballasts; luminaires, which rely on additional optical performance aspects
- Standard12 pagesEnglish languagesale 10% offe-Library read for1 day