ABSTRACT
This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, hydrostatic burst resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings. The pipe and fittings covered are suitable for the drainage and venting of sewage and certain other liquid wastes. A form of marking is also included. The pipe and fittings shall be made of virgin PVC compounds of defined specification. The pipe shall conform to the required stiffness, deflection load and flattening. The fittings shall be subject to hydrostatic burst pressure. The pipe and fittings shall be subject to impact resistance test.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings. A form of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. Installation procedures are given in the Appendix.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: D2665 – 11
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
1
Pipe and Fittings
This standard is issued under the fixed designation D2665; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* (CPVC) Compounds
D2122 Test Method for Determining Dimensions of Ther-
1.1 This specification covers requirements and test methods
moplastic Pipe and Fittings
for materials, dimensions and tolerances, pipe stiffness, crush
D2412 Test Method for Determination of External Loading
resistance,impactresistance,andsolventcementforpoly(vinyl
Characteristics of Plastic Pipe by Parallel-Plate Loading
chloride)plasticdrain,waste,andventpipeandfittings.Aform
D2444 Test Method for Determination of the Impact Resis-
of marking is also included. Plastic which does not meet the
tance of Thermoplastic Pipe and Fittings by Means of a
material requirements specified in Section 5 is excluded.
Tup (Falling Weight)
Installation procedures are given in the Appendix.
D2564 Specification for Solvent Cements for Poly(Vinyl
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
Chloride) (PVC) Plastic Piping Systems
as standard. The values given in parentheses are mathematical
D3311 Specification for Drain, Waste, and Vent (DWV)
conversions to SI units that are provided for information only
Plastic Fittings Patterns
and are not considered standard.
D4396 Specification for Rigid Poly(Vinyl Chloride) (PVC)
1.3 Thetextofthisspecificationreferencesnotes,footnotes,
and Chlorinated Poly(Vinyl Chloride) (CPVC) Com-
and appendixes which provide explanatory material. These
pounds for Plastic Pipe and Fittings Used in Nonpressure
notesandfootnotes(excludingthoseintablesandfigures)shall
Applications
not be considered as requirements of the specification.
F402 Practice for Safe Handling of Solvent Cements, Prim-
1.4 The following safety hazards caveat pertains only to the
ers, and Cleaners Used for JoiningThermoplastic Pipe and
test methods portion, Section 7, of this specification: This
Fittings
standard does not purport to address all of the safety concerns,
F412 Terminology Relating to Plastic Piping Systems
if any, associated with its use. It is the responsibility of the user
F1498 Specification for Taper Pipe Threads 60° for Ther-
of this standard to establish appropriate safety and health
moplastic Pipe and Fittings
practices and determine the applicability of regulatory limita-
F1866 Specification for Poly (Vinyl Chloride) (PVC) Plas-
tions prior to use.
tic Schedule 40 Drainage and DWV Fabricated Fittings
2. Referenced Documents F2135 Specification for Molded Drain, Waste, and Vent
2
(DWV) Short-Pattern Plastic Fittings
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
3. Terminology
D1600 Terminology for Abbreviated Terms Relating to
3.1 Definitions—DefinitionsareinaccordancewithTermi-
Plastics
nology F412, and abbreviations are in accordance with Termi-
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
nology D1600, unless otherwise specified.
Compounds and Chlorinated Poly(Vinyl Chloride)
4. Significance and Use
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
4.1 The requirements of this specification are intended to
Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
provide pipe and fittings suitable for the drainage and venting
Current edition approved Aug. 1, 2011 Published August 2011. Originally
of sewage and certain other liquid wastes.
approved in 1968. Last previous edition approved in 2010 as D2665–10. DOI:
10.1520/D2665-11.
NOTE 1—Industrial waste disposal lines should be installed only with
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
the specific approval of the cognizant building code authority since
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
chemicals not commonly found in drains and sewers and temperatures in
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. excess of 180°F (82.2°C) may be encountered.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D2665 – 11
NOTE 2—This specification does not include requirements for pipe and
cracking, rupture, or other visible evidence of failure when
fittings intended
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:D2665–10 Designation: D2665 – 11
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
1
Pipe and Fittings
This standard is issued under the fixed designation D2665; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush
resistance, impact resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings.Aform
of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. Installation
procedures are given in the Appendix.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes
and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 Thefollowingsafetyhazardscaveatpertainsonlytothetestmethodsportion,Section7,ofthisspecification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 TestMethodforDeterminationoftheImpactResistanceofThermoplasticPipeandFittingsbyMeansofaTup(Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D3311 Specification for Drain, Waste, and Vent (DWV) Plastic Fittings Patterns
D4396 Specification for Rigid Poly(Vinyl Chloride) (PVC) and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds for
Plastic Pipe and Fittings Used in Nonpressure Applications
F402 Practice for Safe Handling of Solvent Cements, Primers, and Cleaners Used for Joining Thermoplastic Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
F1498 Specification for Taper Pipe Threads 60 for Thermoplastic Pipe and Fittings
F1866 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
F2135 Specification for Molded Drain, Waste, and Vent (DWV) Short-Pattern Plastic Fittings
3. Terminology
3.1 Definitions—DefinitionsareinaccordancewithTerminologyF412,andabbreviationsareinaccordancewithTerminology
D1600, unless otherwise specified.
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved Dec.Aug. 1, 20102011 Published FebruaryAugust 2011. Originally approved in 1968. Last previous edition approved in 20092010 as
D2665–109. DOI: 10.1520/D2665-101.
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D2665 – 11
4. Significance and Use
4.1 The requirements of this specification are intended to provide pipe and fittings suitable for the drainage and venting of
sewage and certain other liquid wastes.
NOTE 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant build
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.