Standard Test Method for Performance of Self-Serve Hot Deli Cases

SIGNIFICANCE AND USE
5.1 The energy input rate is used to confirm that the deli case is operating properly prior to further testing.  
5.2 Holding temperature range is useful for food service operators in selecting a unit that matches their holding requirements.  
5.3 Capacity is used by food service operators to choose a deli case that matches their food holding requirements.  
5.4 Preheat energy and time can be useful to food service operators to manage energy demands and to know how quickly the deli case can be ready for operation.  
5.5 Holding energy rate and idle energy rate can be used by the food service operator to estimate deli case energy consumption.
SCOPE
1.1 This test method evaluates the energy consumption and performance of self-serve hot deli cases. The food service operator can use this evaluation to select a deli case and understand its energy consumption and performance.  
1.2 This test method is applicable to electric, fully open or partially open, hot deli cases that have been designed to hold and merchandise prepackaged hot food. For staff-serve hot deli cases, refer to Test Method F2472.  
1.3 The deli case can be evaluated with respect to the following (where applicable):  
1.3.1 Energy input rate (10.2),  
1.3.2 Energy and temperature at the minimum setting (10.3),  
1.3.3 Energy and temperature at the maximum setting (10.3),  
1.3.4 Energy and temperature at the manufacturer's recommended setting (10.3),  
1.3.5 Holding capacity (10.4),  
1.3.6 Holding temperature calibration (10.4),  
1.3.7 Preheat energy rate (10.5),  
1.3.8 Idle energy rate (10.6), and  
1.3.9 Holding energy rate (10.7).  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Apr-2019
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F2141-07(2019) - Standard Test Method for Performance of Self-Serve Hot Deli Cases
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: F2141 − 07 (Reapproved 2019) An American National Standard
Standard Test Method for
1
Performance of Self-Serve Hot Deli Cases
This standard is issued under the fixed designation F2141; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope mendations issued by the World Trade Organization Technical
Barriers to Trade (TBT) Committee.
1.1 This test method evaluates the energy consumption and
performance of self-serve hot deli cases. The food service
2. Referenced Documents
operator can use this evaluation to select a deli case and
2
2.1 ASTM Standards:
understand its energy consumption and performance.
A36/A36MSpecification for Carbon Structural Steel
1.2 This test method is applicable to electric, fully open or
F2472Test Method for Performance of Staff-Serve Hot Deli
partially open, hot deli cases that have been designed to hold
Cases
andmerchandiseprepackagedhotfood.Forstaff-servehotdeli
cases, refer to Test Method F2472.
3. Terminology
1.3 The deli case can be evaluated with respect to the 3.1 calibrated temperature, n—temperaturesettingatwhich
following (where applicable): the lowest temperature of the water in the holding pans is at
1.3.1 Energy input rate (10.2), 142 6 2°F (61 6 1°C).
1.3.2 Energy and temperature at the minimum setting 1
3.2 capacity, n—the amount of ⁄6 size containers the deli
(10.3),
case will hold in a single layer at one time.
1.3.3 Energy and temperature at the maximum setting
3.3 deli case, n—an appliance designed for the display of
(10.3),
hot food product.
1.3.4 Energy and temperature at the manufacturer’s recom-
3.4 energy input rate, n—peak rate at which a deli case
mended setting (10.3),
consumes energy (kW), typically reflected during preheat.
1.3.5 Holding capacity (10.4),
1.3.6 Holding temperature calibration (10.4), 3.5 factory setting, n—recommended control setting by the
1.3.7 Preheat energy rate (10.5), manufacturer.
1.3.8 Idle energy rate (10.6), and
3.6 holding energy, n—energy consumed by the deli case as
1.3.9 Holding energy rate (10.7).
it is used to hold cooked food product under full load
conditions.
1.4 Thevaluesstatedininch-poundunitsaretoberegarded
as standard. The values given in parentheses are mathematical
3.7 holding energy rate, n—average rate of energy con-
conversions to SI units that are provided for information only
sumption (kW) during the holding energy tests.
and are not considered standard.
3.8 idle energy rate, n—the rate of energy consumed (kW)
1.5 This standard does not purport to address all of the
by the deli case while “holding” or maintaining the heated
safety concerns, if any, associated with its use. It is the
surface at the thermostat set point.
responsibility of the user of this standard to establish appro-
3.9 maximum setting, n—settingatwhichmaximumsurface
priate safety, health, and environmental practices and deter-
temperature is achieved.
mine the applicability of regulatory limitations prior to use.
3.10 minimumsetting,n—settingatwhichminimumsurface
1.6 This international standard was developed in accor-
temperature is achieved.
dance with internationally recognized principles on standard-
ization established in the Decision on Principles for the 3.11 preheat energy, n—amount of energy consumed by the
Development of International Standards, Guides and Recom- deli case while preheating the heated surface from ambient
room temperature (75 6 5°F (24 6 3°C)) to a temperature at
the calibrated setting.
1
This test method is under the jurisdiction of ASTM Committee F26 on Food
Service Equipment and is the direct responsibility of Subcommittee F26.06 on
2
Productivity and Energy Protocol. For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Current edition approved May 1, 2019. Published June 2019. Originally contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
approved in 2001. Last previous edition approved in 2013 as F2141–07 (2013). Standards volume information, refer to the standard’s Document Summary page on
DOI: 10.1520/F2141-07R19. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2141 − 07 (2019)
3.12 preheat rate, n—average rate (°F/min (°C/min)) at 6.2 Data Acquisition System, for measuring energy and
which the deli case’s holding surface is heated from ambient temperat
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.