ASTM D5750/D5750M-95
(Guide)Standard Guide for Width and Length of Pressure-Sensitive Tape
Standard Guide for Width and Length of Pressure-Sensitive Tape
SCOPE
1.1 This guide provides guidelines for widths and lengths of pressure-sensitvie tape, including tolerances and labeling in the inch-pound and SI systems. It is not intended for tapes used for medical, surgical, or label stock purposes.
1.2 Units stated in the inch-pound system followed by a calculated unit in the SI system are to be regarded separately as standard and should not be interchangeable with units stated in the SI system. The units stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or
withdrawn. Contact ASTM International (www.astm.org) for the latest information.
Designation: D 5750/D 5750M – 95
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Guide for
1
Width and Length of Pressure-Sensitive Tape
This standard is issued under the fixed designation D 5750/D 5750M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Units of Measurement
1.1 This guide provides guidelines for widths and lengths of 5.1 All widths and lengths are to be stated using a primary
pressure-sensitive tape, including tolerances and labeling in the and a secondary system, the latter being a calculated value
inch-pound and SI systems. It is not intended for tapes used for using procedures stated in Section 11.
medical, surgical, or label stock purposes. 5.2 The unit of width shall be inches or millimetres.
1.2 Units stated in the inch-pound system followed by a 5.3 The unit of length shall be yards or metres. For rolls 72
calculated unit in the SI system are to be regarded separately as yd (2592 in.) and under, the length may be stated in inches.
standard and should not be interchangeable with units stated in 5.4 When width is stated in inches, the length shall be stated
the SI system. The units stated in each system may not be exact in yards. When width is stated in millimetres, the length shall
equivalents; therefore, each system shall be used independently be stated in metres.
of the other.
6. Widths
1.3 This standard does not purport to address all of the
6.1 When the inch-pound system is used as the primary
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- measurement system, roll widths are stated in a modular
1 1
system with ⁄8 in. increments for roll widths under 1 in., ⁄4 in.
priate safety and health practices and determine the applica-
1
bility of regulatory limitations prior to use. increments for roll widths between 1 and 2 in., and ⁄2in.
increments for roll widths over 2 in.
2. Referenced Documents
6.1.1 The SI width shall be calculated (11.1) and listed in
2.1 ASTM Standards: addition to the primary inch-pound width, and should be stated
1
D 4332 Practice for Conditioning Containers, Packages, or in millimetres rounded to the nearest ⁄10 mm.
2
Packaging Components for Testing 6.2 When the SI system is used as the primary measurement
system, widths are stated in a modular systems, with 3-mm
3. Terminology
increments for rolls under 24 mm, 6 mm for increments for roll
3.1 Definitions:
widths between 24 and 48 mm, and 12 mm for roll widths over
3.1.1 pressure-sensitive tape—a pressure-sensitive adhesive 48 mm.
coated substrate in roll form wound on a core, equal to or
6.2.1 The inch width shall be calculated (see 11.2) and
greater than 12 in. (0.305 m) in length. listed, in addition to the primary SI width. The inch width
1
3.1.2 roll length—the length of tape on a roll minus the tab should be stated in inches rounded to the nearest ⁄100 in.
and any tape on the core which cannot be removed and used for
6.3 In any shipment or offering of tape, the average width of
the intended purpose. all rolls shall equal or exceed the stated width.
4. Significance and Use
7. Length
4.1 Conformance to this guide will reduce chances of 7.1 For both the inch-pound and SI systems, the average roll
misunderstanding between suppliers and users of pressure-
length in any shipment or offering of tape shall equal or exceed
sensitive tapes. the stated value.
4.2 It is recommended that this guide be referenced where
8. Tolerances
widths and lengths of pressure-sensitive tapes are stated, such
as in contracts, orders, advertisements, and labeling. 8.1 The applicable tolerance shall be that of the primary
measurement system.
1
8.2 In the inch-pound system, the width tolerances shall be
This specification is under the jurisdiction of ASTM Committee D-10 on
1
Packaging and is the direct responsibility of Subcommittee D10.14 on Closure and
6 ⁄32 in. This applies to rolls less than 36 in. in width.
Reinforcement.
8.3 In the SI system, the width tolerance shall be 60.8 mm.
Current edition approved July 15, 1995. Published September 1995.
2
This applies only to rolls less than 1000 mm in width.
Annual Book of ASTM Standards, Vol 15.09.
1
---------------------- Page: 1 ----------------------
D 5750/D 5750M
9. Labeling 10.3 The secondary measurement is always rounded to the
nearest appropriate interval. In 9.1, 60 yd equals 54.864 m, but
9.1 With both the inch-pound and SI systems, the width
the SI roll length in
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.