ASTM B370-09
(Specification)Standard Specification for Copper Sheet and Strip for Building Construction
Standard Specification for Copper Sheet and Strip for Building Construction
ABSTRACT
This specification establishes the requirements for rolled copper sheets and strips in flat lengths or coils of ounce-weight thicknesses for roofing, flashing, gutters, downspouts, and general sheet metal work in building construction. Products produced to this specification are not intended for electrical applications. Materials are available in the following tempers: O60 (soft), H00 (cold-rolled), H01 (cold-rolled, high yield), H02 (half hard), H03 (three-quarter hard), and H04 (hard). Products shall be sampled and prepared, then tested accordingly to examine their conformance to dimensional (mass, thickness, length, width, weight, and straightness), mechanical (tensile and yield strength, and Rockwell hardness), chemical composition, and grain recrystallization requirements.
SCOPE
1.1 This specification establishes the requirements for rolled copper sheet and strip in flat lengths or coils in ounce-weight thicknesses for roofing, flashing, gutters, downspouts, and general sheet metal work in building construction.
1.1.1 Products produced to this specification are not intended for electrical applications.
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 1—Specification B 101 is an associated specification for lead-coated copper sheets and strip for building construction.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: B370 – 09
Standard Specification for
1
Copper Sheet and Strip for Building Construction
This standard is issued under the fixed designation B370; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* E112 Test Methods for Determining Average Grain Size
E255 Practice for Sampling Copper and Copper Alloys for
1.1 Thisspecificationestablishestherequirementsforrolled
the Determination of Chemical Composition
copper sheet and strip in flat lengths or coils in ounce-weight
E478 TestMethodsforChemicalAnalysisofCopperAlloys
thicknesses for roofing, flashing, gutters, downspouts, and
general sheet metal work in building construction.
3. General Requirements
1.1.1 Products produced to this specification are not in-
3.1 The following sections of Specification B248 constitute
tended for electrical applications.
a part of this specification:
1.2 Units—The values stated in inch-pound units are to be
3.1.1 Terminology,
regarded as standard. The values given in parentheses are
3.1.2 Materials and Manufacture,
mathematical conversions to SI units that are provided for
3.1.3 Workmanship, Finish, and Appearance,
information only and are not considered standard.
3.1.4 Specimen Preparation,
NOTE 1—Specification B101 is an associated specification for lead-
3.1.5 Test Methods,
coated copper sheets and strip for building construction.
3.1.6 Significance of Numerical Limits,
1.3 This standard does not purport to address all of the
3.1.7 Inspection,
safety concerns, if any, associated with its use. It is the
3.1.8 Certification,
responsibility of the user of this standard to establish appro-
3.1.9 Mill Test Report,
priate safety and health practices and determine the applica-
3.1.10 Packaging and Package Marking, and
bility of regulatory limitations prior to use.
3.1.11 Supplementary Requirements.
3.2 In addition, when a section with a title identical to that
2. Referenced Documents
referenced in 3.1, above, appears in this specification, it
2
2.1 ASTM Standards:
contains additional requirements, which supplement those
B101 SpecificationforLead-CoatedCopperSheetandStrip
appearing in Specification B248.
for Building Construction
4. Terminology
B248 Specification for General Requirements for Wrought
Copper and Copper-Alloy Plate, Sheet, Strip, and Rolled
4.1 Definitions—For definitions of terms related to copper
Bar
and copper alloys, refer to Terminology B846.
B601 Classification for Temper Designations for Copper
4.1.1 coil, n—a length of the product wound into a series of
and Copper Alloys—Wrought and Cast
connected turns.
B846 Terminology for Copper and Copper Alloys
4.1.1.1 Discussion—The unqualified term “coil” as applied
E3 Guide for Preparation of Metallographic Specimens
to “flat product” usually refers to a coil in which the product is
E8 Test Methods for Tension Testing of Metallic Materials
spirally wound, with the successive layers on top of one
another (sometimes called a “roll”).
4.1.2 lengths, mill, n—straight lengths, including ends, that
1
ThisspecificationisunderthejurisdictionofASTMCommitteeB05onCopper
are be manufactured conveniently in the mills.
andCopperAlloysandisthedirectresponsibilityofSubcommitteeB05.01onPlate,
Sheet, and Strip. 4.1.2.1 Discussion—Full length pieces usually are 8 or 10 ft
Current edition approved April 1, 2009. Published May 2009. Originally
(2.4 or 3.0 m) and subject to established length tolerances.
approved in 1961. Last previous edition approved in 2003 as B370 – 03. DOI:
4.1.3 length, stock, n—straight lengths that are mill cut and
10.1520/B0370-09.
2
stored in advance of orders.
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM 4.1.3.1 Discussion—They usually are 8 or 10 ft (2.4 or 3.0
Standards volume information, refer to the standard’s Document Summary page on
m) and subject to established length tolerances.
the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
B370 – 09
4.1.4 sheet, for building construction, n—a rolled flat prod- 7.1.1 Limits shall be established and analysis required for
uct over 24 in. (610 mm) in width and of ounce-weight unnamed elements by agreement between the manufacturer
thickness from 8 to 48 oz. and the purchaser.
4.1.5 strip, for building construction, n—a rolled flat p
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:B370–03 Designation: B 370 – 09
Standard Specification for
1
Copper Sheet and Strip for Building Construction
This standard is issued under the fixed designation B 370; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 This specification establishes the requirements for rolled copper sheet and strip in flat lengths or coils in ounce-weight
thicknesses for roofing, flashing, gutters, downspouts, and general sheet metal work in building construction.
1.1.1 Products produced to this specification are not intended for electrical applications.
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are
mathematical conversions to SI units that are provided for information only and are not considered standard.
NOTE 1—Specification B 101 is an associated specification for lead-coated copper sheets and strip for building construction.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
B 101 Specification for Lead-Coated Copper Sheet and Strip for Building Construction
B 248 Specification for General Requirements for Wrought Copper and Copper-Alloy Plate, Sheet, Strip, and Rolled Bar
B 601 Classification for Temper Designations for Copper and Copper Alloys—Wrought and Cast
B 846 Terminology for Copper and Copper Alloys
E3 PracticeGuide for Preparation of Metallographic Specimens
E8 Test Methods for Tension Testing of Metallic Materials
E53Test Methods for Determination of Copper in Unalloyed Copper by Gravimetry
E112 Test Methods for Determining Average Grain Size
E 255 Practice for Sampling Copper and Copper Alloys for the Determination of Chemical Composition
E 478 Test Methods for Chemical Analysis of Copper Alloys
3. General Requirements
3.1 The following sections of Specification B 248 constitute a part of this specification:
3.1.1 Terminology,
3.1.2 Materials and Manufacture,
3.1.3 Workmanship, Finish, and Appearance,
3.1.4 Specimen Preparation,
3.1.5 Test Methods,
3.1.6 Significance of Numerical Limits,
3.1.7 Inspection,
3.1.8 Certification,
3.1.9 Mill Test Report,
3.1.10 Packaging and Package Marking, and
3.1.11 Supplementary Requirements.
3.2 In addition, when a section with a title identical to that referenced in 3.1, above, appears in this specification, it contains
1
This specification is under the jurisdiction of ASTM Committee B05 on Copper and Copper Alloys and is the direct responsibility of Subcommittee B05.01 on Plate,
Sheet, and Strip.
Current edition approved Oct.April 1, 2003.2009. Published November 2003.May 2009. Originally approved in 1961. Last previous edition approved in 19982003 as
B370–98. B 370 – 03.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
B370–09
additional requirements, which supplement those appearing in Specification B 248.
4. Terminology
4.1 Definitions—For definitions of terms related to copper and copper alloys, refer to Terminology B 846.
4.1.1 coil, n—a length of the product wound into a series of connected turns.
4.1.1.1 Discussion—The unqualified term “coil” as applied to “flat product” usually refers to a coil in which the product is
spirally wound, with the successive layers on top of one another (sometimes called a “roll”).
4.1.2 lengths, mill, n—straight lengths, including ends, that are be manufactured conveniently in the mills.
4.1.2.1 Discussion—Full length pieces usually are 8 or 10 ft (2.4 or 3.0 m) and subject to established length tolerances.
4.1.3 length, stock, n—straight lengths that are mill cut and stored in advance of orders.
4
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.