Standard Specification for Asphalt Roll Roofing (Organic Felt)

ABSTRACT
This specification covers three classes and three types of asphalt roll roofing in sheet form, in widths agreed upon between the purchaser and the producer/supplier, and composed of asphalt-saturated organic felt coated on both sides with asphalt. Class M and WS rolls are surfaced on the weather (exposed) side with mineral granules, except for any selvage. Class S rolls are surfaced with powdered talc, mica, or other fine mineral matter to prevent sticking. Type classifications (Types II, III, and IV) are grouped based on minimum net mass per unit area of roofing. Roofing shall adhere to physical property requirements such as breaking strength, water permeance and vapor transmission, width, selvage, area, and moisture.
SCOPE
1.1 This specification covers asphalt roofing in sheet form, in widths agreed upon between the purchaser and the producer/supplier, composed of asphalt-saturated organic felt coated on both sides with asphalt. Class M and WS rolls are surfaced on the (exposed) weather side with mineral granules, except for any selvage. Class S rolls are surfaced with powdered talc, mica, or other fine mineral matter to prevent sticking.
1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-May-2003
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D6380-03 - Standard Specification for Asphalt Roll Roofing (Organic Felt)
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D 6380 – 03
Standard Specification for
1
Asphalt Roll Roofing (Organic Felt)
This standard is issued under the fixed designation D 6380; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope Roll Roofing, Non Fibered, Asbestos Fibered, and Non
2
Abestos Fibered
1.1 This specification covers asphalt roofing in sheet form,
D 4977 Test Method for Granule Adhesion to Mineral
in widths agreed upon between the purchaser and the producer/
2
Surfaced Roofing by Abrasion
supplier, composed of asphalt-saturated organic felt coated on
E 96 Test Methods for Water Vapor Transmission of Mate-
both sides with asphalt. Class M and WS rolls are surfaced on
3
rials
the (exposed) weather side with mineral granules, except for
any selvage. Class S rolls are surfaced with powdered talc,
3. Terminology
mica, or other fine mineral matter to prevent sticking.
3.1 Definitions—Refer to Terminology D 1079 for defini-
1.2 The values stated in SI units are to be regarded as the
tions of terms used in this specification.
standard. The inch-pound units given in parentheses are for
information only.
4. Classification
1.3 This standard does not purport to address all of the
4.1 Class S (smooth) rolls shall be surfaced with fine
safety concerns, if any, associated with its use. It is the
mineral matter to prevent sticking.
responsibility of the user of this standard to establish appro-
4.1.1 Type III—Minimum net mass per unit area of roofing,
priate safety and health practices and determine the applica-
2 2
2495 g/m (51.1 lb/100 ft ).
bility of regulatory limitations prior to use.
4.1.2 Type IV—Minimum net mass per unit area of roofing,
2 2
1943 g/m (39.8 lb/100 ft ).
2. Referenced Documents
4.2 Class M (mineral) rolls shall be surfaced on the weather
2.1 ASTM Standards:
side with mineral granules, except for any selvage.
D 146 Test Methods for Sampling and Testing Bitumen-
4.2.1 Type II—Minimum net mass of granule-surface por-
Saturated Felts and Woven Fabrics for Roofing and Wa-
2 2
2 tion, 3490 g/m (71.5 lb/100 ft ).
terproofing
4.3 Class WS (wide selvage) rolls shall be surfaced on the
D 224 Specification for Smooth-Surfaced Asphalt Roll
2 weather side with mineral granules for approximately half the
Roofing (Organic Felt)
width.
D 228 Test Methods for Sampling, Testing, andAnalysis of
2
4.3.1 Type III—Minimum net mass per unit area, 1733 g/m
Asphalt Roll Roofing, Cap Sheets, and Shingles Used in
2
2 (35.5 lb/100 ft ).
Roofing and Waterproofing
2
4.3.2 Type IV—Minimum net mass per unit area, 2090 g/m
D 249 Specification forAsphalt Roll Roofing (Organic Felt)
2
2 (42.8 lb/100 ft ).
Surfaced with Mineral Granules
D 371 Specification forAsphalt Roll Roofing (Organic Felt)
5. Materials and Manufacture
Surfaced with Mineral Granules; Wide Selvage
5.1 In the process of manufacture, a single thickness of dry
D 1079 Terminology Relating to Roofing, Waterproofing,
2 organic felt shall first be saturated with asphalt. A coating
and Bituminous Materials
asphalt, compounded with or without a fine mineral stabilizer
D 3019 Specification for Lap Cement Used with Asphalt
insoluble in water, shall be applied to one or both sides of the
sheet. Class S rolls shall be surfaced on one side with a suitable
1
This specification is under the jurisdiction of ASTM Committee D08 on
material to prevent sticking in the roll. Class M and WS rolls
Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.02
shall be covered on the weather side with mineral granules,
on Prepared Roofings, Shingles and Siding Materials.
except for any selvage; the reverse side shall be covered with
The materials covered in this standard were previously covered by three separate
a suitable material to prevent sticking in the roll.
roll roofing material standards: Specifications D 224, D 249, and D 371.
Current edition approved May 10, 2003. Published June 2003. Originally
e1
approved in 1999. Last previous edition approved in 2001 as D 6380 – 01 .
2 3
Annual Book of ASTM Standards, Vol 04.04. Annual Book of ASTM Standards, Vol 04.06.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
D6380–03
5.2 The felt shall be roofing felt primarily composed of 7. Dimensions, Mass, and Permissible Variations
organic fibers. The surface of the felt shall be uniformly and
7.1 Width—The material shall be put up in rolls and shall be
relatively smooth. Upon splitting or tearing on the bias, the felt
914 mm (36 in.) wide, 60.7 %. Other widths agreed upon
shall appear reas
...