Standard Test Method for Bulk Density of Tapered Paintbrush Filaments

SIGNIFICANCE AND USE
3.1 Filaments are available in a variety of cross-sections and materials. A measure of bulk density permits the brushmaker to estimate the weight of filament required to prepare a given number of brushes.
SCOPE
1.1 This test method covers a procedure for measuring the weight of filaments per unit volume.  
1.2 This method is applicable only to monofilament with tapered longitudinal profiles.  
1.3 The values given in SI units are to be regarded as the standard. The values given in parentheses are for information only.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-May-2012
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM D6737-12 - Standard Test Method for Bulk Density of Tapered Paintbrush Filaments
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM D6737-12 - Standard Test Method for Bulk Density of Tapered Paintbrush Filaments
English language
3 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D6737 − 12
Standard Test Method for
1
Bulk Density of Tapered Paintbrush Filaments
This standard is issued under the fixed designation D6737; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
4
1. Scope and cylinder just described.The Pi tape must be fixed in place
so that it reads accurately the diameter of a metal calibration
1.1 This test method covers a procedure for measuring the
standard that is 50.8-mm (2.00-in.) diameter. The Pi tape is
weight of filaments per unit volume.
mounted on an adjustable plate for calibration.
1.2 This method is applicable only to monofilament with
4.2 Weighing Device, accurate to 0.1 g to weigh the bundle.
tapered longitudinal profiles.
4.3 Graduated, Linear Scale, accurate to 0.5-mm (0.02-in.)
1.3 The values given in SI units are to be regarded as the
to measure the bundle length.
standard. The values given in parentheses are for information
only. 4.4 Air Supply, with pressure regulator set for 40 psig.
5
1.4 This standard does not purport to address all of the
4.5 Calibration Standard, 50.8-mm (2.00-in.) in diameter.
safety concerns, if any, associated with its use. It is the
5. Sampling, Test Specimens and Test Units
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
5.1 The test result depends on the cross-sectional shape, the
bility of regulatory limitations prior to use.
polymer, and the length of the bundle selected for the test. To
a lesser extent, it also depends on the filament diameter, since
2. Summary of Test Method
thin filaments pack more efficiently than large ones.
2.1 The weight, length and diameter of a bundle of tapered
5.2 The device, as pictured in Fig. 1, is designed to measure
filaments are measured, and the bundle density is calculated.
diameters ranging from 30.5 to 52.3 mm (1.20 to 2.06 in.).
Make sure that both ends to be measured are within this range.
3. Significance and Use
5.3 Calculations are based on conical bundle shape.
3.1 Filamentsareavailableinavarietyofcross-sectionsand
materials.Ameasureofbulkdensitypermitsthebrushmakerto
6. Procedure
estimate the weight of filament required to prepare a given
6.1 Select a sample bundle of approximately 50-mm (2.0-
number of brushes.
in.) diameter. Filament may be removed from a sample so the
bundle diameter falls within the scale range 30.5 to 52.3-mm
4. Apparatus
(1.20 to 2.06-in.). One convenient method to adjust the sample
4.1 The apparatus requires some machining, and is as-
diameter to the desired range is to fill a 50-mm (2.0-in.) inside
sembled as shown in Fig. 1 from the following equipment:
diameter tube. If the sample is too small, like samples may be
2
4.1.1 Air Valve.
combined to adjust the bundle diameter to the desired range.
3
4.1.2 Miniature Air Cylinder, dual acting, heavy duty.
6.2 With rubber bands holding the bundle together, roll it
4.1.3 AssortedpartsshowninFig.1aremachinedfrom304
between the palms of the hands four times to allow the
stainlesssteelandassembledasshownalongwiththeairvalve
filaments to nest. Place the larger end of the bundle inside the
loop of measuring tape in the device shown in Fig. 2.
6.3 Gently tap the top of the bundle to make certain that all
1
This test method is under the jurisdiction of ASTM Committee D01 on Paint
filamentsaremakingcontactwiththebottomplate.Thebundle
and Related Coatings, Materials, andApplications and is the direct responsibility of
Subcommittee D01.61 on Paint Application Tools.
should be kept perpendicular to the bottom plate. The rubber
CurrenteditionapprovedJune1,2012.PublishedJuly2012.Originallyapproved
bands must be located where they do not interfere with the
in 2001. Last previous edition approved in 2006 as D6737–01 (2006). DOI:
10.1520/D6737-12.
2
Air valve such as Model 6676 available from Hunt Valve Co., 1913 E. State
4 1
Street, Salem, Ohio 44460, or equivalent, has been found suitable for this purpose. Pi tape ⁄4in.(6mm)×6ft (1.8 m) with 0.01 in. graduations. Lufkin model
3
3
MiniatureaircylindersuchasModel047DXP, ⁄4in.(19.0mm)bore7in.(178 W606P, or equivalent, has been found suitable for this purpose.
5
mm)stroke,dualacting,heavydutyavailablefromBimbaManufacturingCompany, Steel cylinder machined to diameter of 2.000 by tolerance (0.001 by 0.001) in.
Monee, IL 60449-0068, or equivalent, has been found suitable for this purpose. (50.8 by tolerance (0.02 by 0.02) mm).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: D6737 − 01 (Reapproved 2006) D6737 − 12
Standard Test Method for
1
Bulk Density of Tapered Paintbrush Filaments
This standard is issued under the fixed designation D6737; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers a procedure for measuring the weight of filaments per unit volume.
1.2 This method is applicable only to monofilament with tapered longitudinal profiles.
1.3 The values given in SI units are to be regarded as the standard. The values given in parentheses allow for calculating the
3
bulk density in g/in.are for information only. , a commonly used form.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Summary of Test Method
2.1 The weight, length and diameter of a bundle of tapered filaments are measured, and the bundle density is calculated.
3. Significance and Use
3.1 Filaments are available in a variety of cross-sections and materials. A measure of bulk density permits the brushmaker to
estimate the weight of filament required to prepare a given number of brushes.
4. Apparatus
4.1 The apparatus requires some machining, and is assembled as shown in Fig. 1 from the following equipment:
2
4.1.1 Air Valve.
3
4.1.2 Miniature Air Cylinder, dual acting, heavy duty.
4.1.3 Assorted parts shown in Fig. 1 are machined from 304 stainless steel and assembled as shown along with the air valve
4
and cylinder just described. The Pi tape must be fixed in place so that it reads accurately the diameter of a metal calibration
standard that is 50.8-mm (2.00-in.) diameter. The Pi tape is mounted on an adjustable plate for calibration.
4.2 Weighing Device, accurate to 0.1 g to weigh the bundle.
4.3 Graduated, Linear Scale, accurate to 0.5-mm (0.02-in.) to measure the bundle length.
4.4 Air Supply, with pressure regulator set for 40 psig.
5
4.5 Calibration Standard, 50.8-mm (2.00-in.) in diameter.
5. Sampling, Test Specimens and Test Units
5.1 The test result depends on the cross-sectional shape, the polymer, and the length of the bundle selected for the test. To a
lesser extent, it also depends on the filament diameter, since thin filaments pack more efficiently than large ones.
5.2 The device, as pictured in Fig. 1, is designed to measure diameters ranging from 30.5 to 52.3 mm (1.20 to 2.06 in.). Make
sure that both ends to be measured are within this range.
1
This test method is under the jurisdiction of ASTM Committee D01 on Paint and Related Coatings, Materials, and Applications and is the direct responsibility of
Subcommittee D01.61 on Paint Application Tools.
Current edition approved Nov. 1, 2006June 1, 2012. Published November 2006July 2012. Originally approved in 2001. Last previous edition approved in 20012006 as
D6737 - 01.D6737 - 01 (2006). DOI: 10.1520/D6737-01R06.10.1520/D6737-12.
2
Air valve such as Model 6676 available from Hunt Valve Co., 1913 E. State Street, Salem, Ohio 44460, or equivalent, has been found suitable for this purpose.
3 3
Miniature air cylinder such as Model 047 DXP, ⁄4 in. (19.0 mm) bore 7 in. (178 mm) stroke, dual acting, heavy duty available from Bimba Manufacturing Company,
Monee, IL 60449-0068, or equivalent, has been found suitable for this purpose.
4 1
Pi tape ⁄4 in. (6 mm) × 6 ft (1.8 m) with 0.01 in. graduations. Lufkin model W606P, or equivalent, has been found suitable for this purpose.
5
Steel cylinder machined to diameter of 2.000 by tolerance (0.001 by 0.001) in. (50.8 by tolerance (0.02 by 0.02) mm).
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D6737 − 12
FIG. 1 Apparatus to Measure Bundle Diameter
5.3 Calculations are based on conical bundle shape.
6. Procedure
6.1 Select a sample bundle of approximately 50-mm (2.0-in.) diameter. Filament may be removed from a sample so the bundle
diameter falls within the scale range 30.5 to 52.3-mm (1.20 to 2.06-in.). One convenient method to adjust the sample diameter to
the desired range is to fill a 50-mm (2.0-in.) inside diameter tube. If th
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.